Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Orthop Trauma Surg ; 144(1): 251-257, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37878075

ABSTRACT

INTRODUCTION: The STRYKER ADAPT computer-assisted navigation system provides intraoperative feedback to the surgeon regarding implant placement of the Gamma3 nail. The usability of the ADAPT system has not been evaluated. The aim of the study was to investigate the perceived usability of the ADAPT system. MATERIALS AND METHODS: This was a descriptive study with prospectively collected data. ADAPT was introduced at Aarhus University Hospital in February 2021. Prior to introduction, surgeons at the department attended a general introduction to the system. ADAPT was introduced to the surgical nurses and was on display at the surgical ward at more than one occasion, where personal introduction to the system was possible. After introduction, it was mandatory to use ADAPT when using the Gamma3 nail to treat intertrochanteric femur fractures. After each procedure, primary and an eventual supervisor answered a questionnaire, which encompassed the System Usability Scale (SUS) questionnaire. The SUS is a ten-item questionnaire regarding the perceived usability of a system. SUS scores were translated to adjectives, describing user experience on a 7-point adjective scale (worst imaginable, awful, poor, ok, good, excellent, best imaginable). User acceptability, defined as "not acceptable", "marginal" or "acceptable", was also used to interpret the SUS scores. RESULTS: ADAPT was used in 50 procedures by 29 different surgeons, with varying skill-level. Median SUS-score after first-time use of ADAPT for all 29 surgeons was 43 (range: 5-60), which translated to "poor" or "not acceptable". For surgeons who performed ≥ 3 ADAPT-assisted procedures, there were no statistically significant difference in their first to latest SUS-score (median difference: 4.3, p = 0.5). In free text comments ADAPT was positively described as helpful in placement of K-wire and providing educational opportunities for inexperienced surgeons and negatively as inconsistent, slow, time consuming, and causing excessive fluoroscopy. CONCLUSIONS: Usability and acceptability of ADAPT was rated as "poor" or "not acceptable" by the majority of operating surgeons. ADAPT has not been used at our institution based on these findings. The System Usability Scale may be used in further research exploring usability and acceptability of novel computer-assisted navigation systems for orthopaedic surgery.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Surgeons , Surgery, Computer-Assisted , Humans , Bone Screws , Hip Fractures/surgery , Surgery, Computer-Assisted/methods , Computers , Fracture Fixation, Intramedullary/methods
2.
J Clin Med ; 12(23)2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38068498

ABSTRACT

Intertrochanteric femoral fractures are commonly treated with intramedullary nails (IMNs). A tip-apex distance (TAD) of more than 20-25 mm is associated with an increased risk of cut-out. The Stryker Adaptive Positioning System (ADAPT) is a computer-assisted navigation system designed to reduce TADs. We aim to assess if the ADAPT reduces the number of outliers with a TAD > 20 mm. All patients with intertrochanteric fractures treated with an IMN between 1 September 2020 and 12 March 2022 were included. Patients were included in three periods: a pre-ADAPT period (55 patients); an ADAPT period (50 patients), where it was compulsory to use the system; and a post-ADAPT period after the discontinuation of the system (59 patients). The TADs and lag screw protrusions beyond the lateral cortex were measured. The median TADs in the three periods were 17.0 mm (8-31 mm), 15.5 mm (9-30 mm), and 18.0 mm (11-32 mm), respectively. The absolute number of outliers with a TAD > 20 mm decreased from 15/55 patients in the pre-ADAPT period to 11/50 patients during the ADAPT period. This observation was not statistically significant, but this is likely due to the lack of power of the present study to show changes of this magnitude. However, our expectation that the ADAPT would diminish outliers markedly or close to zero outliers was not met, as we observed 11/50 = 22% outliers with a TAD > 20 mm when using computer-assisted surgery, i.e., ADAPT and Gamma3 for intertrochanteric fractures. Based on these findings, the use of the ADAPT was discontinued at our level 1 trauma center.

SELECTION OF CITATIONS
SEARCH DETAIL
...