Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Ophthalmol ; 23(1): 129, 2023 Mar 30.
Article in English | MEDLINE | ID: mdl-36997879

ABSTRACT

PURPOSE: To compare the effectiveness and safety of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco/ECP), phacoemulsification combined with MicroPulse transscleral cyclophotocoagulation (phaco/MP-TSCPC), and phacoemulsification alone (phaco) in the treatment of coexisting cataract and glaucoma. METHODS: Retrospective cohort study of consecutive cases at Massachusetts Eye & Ear. The main outcome measures were the cumulative probabilities of failure between the phaco/ECP group, phaco/MP-TSCPC group, and the phaco alone group with failure defined as reaching NLP vision at any point postoperatively, undergoing additional glaucoma surgery, or the inability to maintain ≥ 20% IOP reduction from baseline with IOP between 5-18 mmHg while maintaining ≤ baseline medications. Additional outcome measures included changes in average IOP, number of glaucoma medications, and complication rates. RESULTS: Sixty-four eyes from 64 patients (25 phaco/ECP, 20 phaco/MPTSCPC, 19 phaco alone) were included in this study. The groups did not differ in age (mean 71.04 ± 6.7 years) or length of follow-up time. Baseline IOPs were significantly different between groups (15.78 ± 4.7 mmHg phaco/ECP, 18.37 ± 4.6 mmHg phaco/MP-TSCPC, 14.30 ± 4.2 mmHg phaco alone, p = 0.02). Primary open-angle glaucoma was the most common type of glaucoma in the phaco alone (42%) and phaco/ECP (48%) groups while mixed-mechanism glaucoma was the most common type in the phaco/MP-TSCPC group (40%). Surgical failure was less likely in eyes in the phaco/MP-TSCPC (3.40 times, p = 0.005) and phaco/ECP (1.40 times, p = 0.044) groups compared to phaco alone based on the Kaplan-Meier survival criteria. These differences maintained statistical significance when differences in preoperative IOP were taken into account using the Cox PH model (p = 0.011 and p = 0.004, respectively). Additionally, surgical failure was 1.98 times less likely following phaco/MP-TSCPC compared to phaco/ECP (p = 0.038). This difference only approached significance once differences in preoperative IOP were accounted for (p = 0.052). There was no significant difference in IOP reduction at 1 year between groups. Mean IOP reductions at 1 year were 3.07 ± 5.3 mmHg from a baseline of 15.78 ± 4.7 in the phaco/ECP group, 6.0 ± 4.3 mmHg from a baseline of 18.37 ± 4.6 in the phaco/MP-TSCPC group and 1.0 ± 1.6 from a baseline of 14.30 ± 4.2 mmHg in the phaco alone group. There were no differences in complication rates among the three groups. CONCLUSIONS: Both Phaco/MP-TSCPC and phaco/ECP appear to provide superior efficacy for IOP control when compared to phaco alone. All three procedures had similar safety profiles.


Subject(s)
Glaucoma, Open-Angle , Glaucoma , Ocular Hypotension , Phacoemulsification , Humans , Middle Aged , Aged , Phacoemulsification/methods , Intraocular Pressure , Glaucoma, Open-Angle/complications , Glaucoma, Open-Angle/surgery , Retrospective Studies , Laser Coagulation/methods , Glaucoma/surgery , Treatment Outcome
2.
BMJ ; 377: e067966, 2022 06 16.
Article in English | MEDLINE | ID: mdl-35710120

Subject(s)
Corneal Diseases , Female , Humans
3.
Eye (Lond) ; 36(2): 424-432, 2022 02.
Article in English | MEDLINE | ID: mdl-33692536

ABSTRACT

BACKGROUND/OBJECTIVE: To report the initial outcomes of phacoemulsification, endoscopic cyclophotocoagulation, and dual blade ab interno trabeculectomy (PEcK), and compare them to those of phacoemulsification, endoscopic cyclophotocoagulation, and trabecular micro-bypass stent insertion (ICE-1). SUBJECTS/METHODS: Patients from January 2018 to December 2019 that underwent PEcK or ICE-1 at a tertiary referral centre were included in this retrospective comparative case series. Patients were excluded if they had additional concomitant procedures, less than 6 weeks (42 days) of follow-up or were not at least 18 years old. Intraocular pressure (IOP), number of glaucoma medications, and best-corrected visual acuity were collected preoperatively and postoperatively at 6 weeks, 3, 6, and 12 months. Kaplan-Meier survival analysis and Cox proportional-hazards regression were conducted to elucidate any factors associated with survival time. RESULTS: The mean preoperative IOP was 18.3 ± 5.9 mmHg in the PEcK group (53 eyes) and 14.7 ± 4.3 mmHg in the ICE-1 group (23 eyes) (p = 0.004) on 3.3 ± 1.3 and 1.7 ± 0.93 glaucoma medications (p < 0.001), respectively. Twelve months postoperatively the mean IOP reduction was 5.1 ± 4.4 mmHg and 2.3 ± 4.0 mmHg (p = 0.08), and the mean medication reduction was 1.6 ± 1.5 and 0.97 ± 0.66 (p = 0.10), in the PEcK and ICE-1 groups, respectively. Kaplan-Meier survival analysis did not reveal any differences in treatment survival. CONCLUSIONS: Both PEcK and ICE-1 provide clinically relevant reductions in IOP and glaucoma medication burden, however the PEcK procedure may confer greater reductions in IOP. The procedures did not differ with regard to Kaplan-Meier survival probability.


Subject(s)
Glaucoma, Open-Angle , Glaucoma , Phacoemulsification , Trabeculectomy , Adolescent , Glaucoma/surgery , Glaucoma, Open-Angle/surgery , Humans , Intraocular Pressure , Retrospective Studies , Stents , Trabeculectomy/methods , Treatment Outcome , Visual Acuity
4.
J Ophthalmol ; 2021: 8860601, 2021.
Article in English | MEDLINE | ID: mdl-33643665

ABSTRACT

PURPOSE: To compare the effectiveness and safety of 360° and 180° of Selective Laser Trabeculoplasty (SLT) for the treatment of elevated intraocular pressure (IOP). METHODS: Retrospective cohort study. The main outcome measure was the Kaplan-Meier analysis comparing the cumulative probabilities of survival between the 360° and 180° SLT groups in terms of IOP reduction. Success was defined as ≥20% IOP reduction from baseline with an IOP between 5-18 mmHg and ≤1 glaucoma medication added postoperatively. Additional outcome measures included changes in average IOP, number of glaucoma medications, and the incidence of postoperative IOP spikes. Measurements were obtained at 6 weeks, 1 year, and 2 years postoperatively. RESULTS: Two hundred and fifty-eight eyes of 258 patients were included in the 360° group, and 196 eyes of 196 patients were included in the 180° group. The mean IOP reductions at 2 years were 2.21 ± 2.02 mmHg and 2.43 ± 1.81 mmHg (p=0.33) in the 180° and 360° groups, respectively. There were no significant differences in the incidence of postoperative IOP spikes between the two groups. There was a significant difference in the survival curves of the two groups (p=0.035). The Cox proportional-hazard model indicated that 360° of SLT application was a significant predictor of long-term success (p=0.030). CONCLUSIONS: 360° of SLT application seems to provide for greater long-term IOP control than 180° of application without putting patients at an elevated risk for postoperative IOP spikes.

5.
Semin Ophthalmol ; 35(5-6): 261-275, 2020 Aug 17.
Article in English | MEDLINE | ID: mdl-32936725

ABSTRACT

Cyclodestruction aims to reduce aqueous humor production through the coagulation or destruction of the ciliary body and has been an important treatment choice for glaucoma since the 1930s. The purpose of the current review is to highlight the evidence regarding the safety and efficacy of various cyclodestructive modalities, emphasizing peer-reviewed articles from the last 20 years and the most common variants of these procedures. The review focuses primarily on the two most common variants of transscleral cyclophotocoagulation (TS-CPC), continuous-wave diode cyclophotocoagulation (CW-TSCPC) and MicroPulse diode cyclophotocoagulation (MP-TSCPC) as well as endoscopic cyclophotocoagulation (ECP) and high-intensity focused ultrasound cyclodestruction (HIFU). We believe that the role of cyclodestruction in glaucoma treatment will only continue to expand given the advances in the field, particular with regards to targeted ciliary body destruction and improvement in the safety profile.


Subject(s)
Ciliary Body/surgery , Endoscopy/methods , Glaucoma/surgery , Intraocular Pressure/physiology , Laser Coagulation/methods , Lasers, Semiconductor/therapeutic use , Visual Acuity , Glaucoma/physiopathology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL