Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Global Spine J ; : 21925682241247489, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38606957

ABSTRACT

STUDY DESIGN: Retrospective cohort study. OBJECTIVE: The study aimed to compare the radiological parameters, clinical outcomes, and long-term effects of the posterior osteosynthesis with polyaxial screw-rod system and the monoaxial screw-rod system in the treatment of unstable atlas fractures. METHODS: We retrospectively analyzed the clinical data of 33 patients with posterior ORIF for unstable atlas fractures in our hospital from August 2013 to June 2020, with a minimum of 3 years of follow-up. Polyaxial screws (group A) were used in 12 patients and monoaxial screws (group B) in 21 patients. Perioperative data, radiological parameters, and clinical outcomes were collected and compared between the 2 surgical approaches. RESULTS: The operative time, blood loss, time of screw-rod system placement, and hospital stay were significantly lower in group A than in group B. At the last follow-up, the visual analog scale (VAS) score and anterior arch reduction rate of the atlas in group A were lower than those in group B, while the lateral mass displacement (LMD) in group A was higher than that in group B. There was no significant difference between Group A and Group B in terms of the anterior atlantodental interval (AADI), posterior arch reduction rate of the atlas, range of motion (ROM), and neck disability index (NDI). CONCLUSIONS: Monoaxial screws can achieve better reduction results for unstable atlas fractures, especially for the anterior arch of atlas. However, the surgical operation of monoaxial screws is more complicated than that of polyaxial screws and has more complications. Appropriate implants should be selected for the treatment of unstable atlas fractures based on the type of atlas fracture, the experience of surgeons, and the demands of patients.

2.
J Orthop Surg Res ; 19(1): 120, 2024 Feb 05.
Article in English | MEDLINE | ID: mdl-38317156

ABSTRACT

BACKGROUND: Osteosynthesis of unstable atlas fractures preserves joint motion and therefore has a distinct advantage over a range of treatment procedures. To prevent the potential disadvantages associated with osteosynthesis, a new atlas lateral mass screw-plate (LMSP) system has been designed. However, the biomechanical role of using the LMSP system in atlas internal fixation is not known. The aim of this study was to compare the biomechanical stability of a new LMSP with traditional posterior screw and rod (PSR) fixation techniques on the occipitocervical junction (C0-C2) through finite element analysis. METHODS: A nonlinear C0-C2 finite element model of the intact upper cervical spine was developed and validated. The unstable model using the PSR system was then compared with the model using the LMSP system for fixation. A vertical load of 40 N was applied to the C0 to simulate head weight, while a torque of 1.5 Nm was applied to the C0 to simulate flexion, extension, lateral bending, and axial rotation. RESULTS: The range of motion of both systems was close to the intact model. Compared with the LMSP system model, the PSR system model increased flexion, extension, lateral bending, and axial rotation by 4.9%, 3.0%, 5.0%, and 29.5% in the C0-C1 segments, and 4.9%, 2.7%, 2.4%, and 22.6% in the C1-C2, respectively. In flexion, extension, and lateral bending motion, the LMSP system model exhibited similar stress to the PSR system model, while in axial rotation, the PSR system model exhibited higher stress. CONCLUSIONS: The findings of our study indicate that the two tested system models provide comparable stability. However, better stability was achieved during axial rotation with the LMSP system, and in this system, the maximum von Mises stress was less than that of the PSR one. As the atlantoaxial joint functions primarily as a rotational joint, the use of the LMSP system may provide a more stable environment for the joint that has become unstable due to fracture.


Subject(s)
Atlanto-Axial Joint , Spinal Fusion , Finite Element Analysis , Biomechanical Phenomena , Bone Screws , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Rotation , Spinal Fusion/methods , Atlanto-Axial Joint/surgery , Range of Motion, Articular
3.
J Orthop Surg Res ; 19(1): 129, 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38331873

ABSTRACT

PURPOSE: The treatment of unstable atlas fractures remains a controversial topic. The study aims at assessing the prognosis and efficacy of osteosynthesis for unstable atlas fractures through a review of the current literature and additionally aims to compare outcomes between the transoral and posterior approaches. METHODS: A systematic review of databases including PubMed, EMBASE, Cochrane, Web of Science, CNKI, and Wanfang was conducted. Titles and abstracts were screened by two reviewers to identify studies meeting pre-defined inclusion criteria for comprehensive analysis. RESULTS: The systematic review included 28 articles, 19 employing the posterior approach and 9 utilizing the transoral approach. It covered osteosynthesis in 297 patients with unstable atlas fractures, comprising 169 treated via the posterior approach and 128 via the transoral approach. Analysis revealed high healing rates and clinical improvement in both approaches, evidenced by improvements in the visual analog scale, range of motion, atlantodens interval, and lateral displacement distance post-surgery. CONCLUSION: Osteosynthesis offers effective treatment for unstable atlas fractures. Both transoral and posterior approaches can achieve good clinical outcomes for fracture, and biomechanical studies have confirmed that osteosynthesis can maintain the stability of the occipitocervical region, preserve the motor function of the atlantoaxial and occipito-atlantoaxial joints, and greatly improve the quality of life of patients. However, variations exist in the indications and surgical risks associated with each method, necessitating their selection based on a thorough clinical evaluation of the patient's condition.


Subject(s)
Cervical Atlas , Fractures, Comminuted , Spinal Fractures , Humans , Cervical Atlas/injuries , Cervical Atlas/surgery , Quality of Life , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Treatment Outcome , Fracture Fixation, Internal/methods , Fractures, Comminuted/surgery
4.
J Clin Neurosci ; 111: 22-25, 2023 May.
Article in English | MEDLINE | ID: mdl-36921553

ABSTRACT

The recent C1 pedicle screw technique for upper cervical vertebral stabilization allows longer screws to be implanted by setting the screw entry point through the posterior arch of C1, which could provide better biomechanics. However, there is controversy regarding the placement of C1 pedicle screws at different angles. We retrospectively reviewed the computed tomography (CT) scans of 300 patients. The trajectories of medial inclination of 0°, 5°, 10°, and 15° and trajectory of the maximum medial inclination angle were designed for each C1 pedicle on CT images. Screw track length at each angle, the angle of maximum medial inclination, pedicle height, distance from the screw entry point to the midpoint of the C1 posterior tubercle, and screw perforation rate at each angle were measured. The average maximum inclination angle was 17.01°, the maximum inclination angle screw track length was 31.05 mm, and the distance from the screw entry point to the midpoint of the C1 posterior nodule was 21.65 mm. The screw perforation rate was 46.73% at 15° of medial inclination, but only 5.61% at 10°, and no screw perforation at 5°. 26.47% C1 pedicle height < 4 mm. There was no significant difference between the measured data on the left and right sides(P > 0.05), and the measurement of female patients was usually smaller and significantly different from that of male patients(p < 0.05). Our data indicate that a reasonable screw inclination angle of 10° and the safety zone of screw angle can provide safety and avoid screw perforation. However, personalized measurement before surgery is essential.


Subject(s)
Pedicle Screws , Spinal Fusion , Humans , Male , Female , Retrospective Studies , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Tomography, X-Ray Computed , Spinal Fusion/methods
5.
World Neurosurg ; 172: 66-70, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36739898

ABSTRACT

BACKGROUND: C1 lateral mass fractures (LMF) cause abnormal alignment of the upper cervical joints. Conservatively treated cases can develop into late cock-robin junction, requiring a reconstructive surgical procedure of the occipitocervical junction. Partial coronal C1 LMF could be effectively fixed with lag screws. Navigation and robot-assisted techniques have made percutaneous fixation possible and are gradually being used in the upper cervical spine. METHODS: Five consecutive patients with C1 LMF who underwent percutaneous lag screw osteosynthesis under the guidance of a new robotic system were reviewed retrospectively. Preoperative and postoperative computed tomography scans were used to specify the fracture types and to assess the efficacy of fracture reduction. The medical records were reviewed. RESULTS: Among the 5 patients, 4 underwent percutaneous lag screw reduction and fixation with the assistance of the robotic system through a posterior approach and 1 patient underwent a transoral approach. No intraoperative complications, such as screw malposition, neurologic deficit, and vertebral artery injury, occurred. Satisfactory fracture reduction and bone healing were achieved at postoperative follow-up. CONCLUSIONS: Robot-assisted percutaneous lag screw osteosynthesis is a viable option for C1 LMF. Different approaches can be selected according to the distribution of the fracture lines. With the posterior approach, the guidewire tends to deviate from the entry point because of skiving, and the technical problems need to be further solved. Screw implant by a transoral approach is comparatively easy to achieve, but the possibly of infection exists and should be monitored.


Subject(s)
Fractures, Bone , Robotics , Spinal Fractures , Humans , Retrospective Studies , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Bone Screws , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Fracture Fixation, Internal/methods
6.
BMC Musculoskelet Disord ; 24(1): 108, 2023 Feb 09.
Article in English | MEDLINE | ID: mdl-36759784

ABSTRACT

BACKGROUND: In the treatment of unstable atlas fractures using the combined anterior-posterior approach or the posterior monoaxial screw-rod system, factors such as severe trauma or complex surgical procedures still need to be improved despite the favourable reduction effect. This research described and evaluated a new technique for the treatment of unstable atlas fracture using a self-designed lateral mass screw-plate system. METHODS: A total of 10 patients with unstable atlas fractures using this new screw-plate system from January 2019 to December 2021 were retrospectively reviewed. All patients underwent posterior open reduction and internal fixation (ORIF) with a self-designed screw-plate system. The medical records and radiographs before and after surgery were noted. Preoperative and postoperative CT scans were used to determine the type of fracture and evaluate the reduction of fracture. RESULTS: All 10 patients were successfully operated with this new system, with an average follow-up of 16.7 ± 9.6 months. A total of 10 plates were placed, and all 20 screws were inserted into the atlas lateral masses. The mean operating time was 108.7 ± 20.1 min and the average estimated blood loss was 98.0 ± 41.3 ml. The lateral mass displacement (LMD) averaged 7.1 ± 1.9 mm before surgery and almost achieved satisfactory reduction after surgery. All the fractures achieved bony healing without reduction loss or implant failure. No complications (vertebral artery injury, neurologic deficit, or wound infection) occurred in these 10 patients. At the final follow-up, the anterior atlantodens interval (AADI) was 2.3 ± 0.8 mm and the visual analog scale (VAS) was 0.6 ± 0.7 on average. All patients preserved almost full range of motion of the upper cervical spine and achieved a good clinical outcome at the last follow-up. CONCLUSIONS: Posterior osteosynthesis with this new screw-plate system can provide a new therapeutic strategy for unstable atlas fractures with simple and almost satisfactory reduction.


Subject(s)
Cervical Atlas , Fractures, Bone , Spinal Fractures , Humans , Cervical Atlas/diagnostic imaging , Cervical Atlas/surgery , Cervical Atlas/injuries , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Spinal Fractures/complications , Retrospective Studies , Fractures, Bone/complications , Fracture Fixation, Internal/methods , Bone Screws , Treatment Outcome
SELECTION OF CITATIONS