Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Thorac Cardiovasc Surg ; 28(3): 227-231, 2022 Jun 20.
Article in English | MEDLINE | ID: mdl-32418925

ABSTRACT

We report a surgical case of bronchial artery aneurysm (BAA) that directly connected to a pulmonary artery and a pulmonary vein through an abnormal vessel. It was complicated by racemose hemangioma. This is a rare vascular malformation. An 82-year-old female had a large BAA that was found incidentally. First, we consider treating the BAA with embolization by interventional radiology (IVR). However, because of strong meandering of the bronchial artery, we could not advance a microcatheter into the BAA. Therefore, a surgical operation was performed through a standard posterior lateral thoracotomy. The BAA was located between the upper and lower lobes and directly connected to the pulmonary artery. Some bronchial artery branches that provided inflow to the aneurysm were ligated, and the abnormal vessel that connected the BAA to the upper pulmonary vein was ligated easily. A fistula between the BAA and pulmonary artery was sutured by the cardiovascular surgeon using an artificial cardiopulmonary device, with permissive stenosis of A2b (ascending A2).


Subject(s)
Aneurysm , Embolization, Therapeutic , Hemangioma , Aged, 80 and over , Aneurysm/complications , Aneurysm/diagnostic imaging , Bronchial Arteries/abnormalities , Bronchial Arteries/diagnostic imaging , Bronchial Arteries/surgery , Female , Hemangioma/complications , Hemangioma/diagnostic imaging , Hemangioma/surgery , Humans , Pulmonary Artery/abnormalities , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Treatment Outcome
2.
Magn Reson Med ; 60(6): 1269-75, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19030159

ABSTRACT

MRI is emerging as a diagnostic modality to track iron-oxide-labeled stem cells. This study investigates whether an off-resonance (OR) pulse sequence designed to generate positive contrast at 1.5T can assess the location, quantity, and viability of delivered stem cells in vivo. Using mouse embryonic stem cell transfected with luciferase reporter gene (luc-mESC), multimodality validation of OR signal was conducted to determine whether engraftment parameters of superparamagnetic iron-oxide labeled luc-mESC (SPIO-luc-mESC) could be determined after cell transplantation into the mouse hindlimb. A significant increase in signal- and contrast-to-noise of the SPIO-luc-mESC was achieved with the OR technique when compared to a gradient recalled echo (GRE) sequence. A significant correlation between the quantity of SPIO-luc-mESC and OR signal was observed immediately after transplantation (R(2) = 0.74, P < 0.05). The assessment of transplanted cell viability by bioluminescence imaging (BLI) showed a significant increase of luciferase activities by day 16, while the MRI signal showed no difference. No significant correlation between BLI and MRI signals of cell viability was observed. In conclusion, using an OR sequence the precise localization and quantitation of SPIO-labeled stem cells in both space and time were possible. However, the OR sequence did not allow evaluation of cell viability.


Subject(s)
Embryonic Stem Cells/cytology , Iron , Magnetic Resonance Imaging/methods , Oxides , Animals , Cells, Cultured , Dextrans , Ferrosoferric Oxide , Iron/administration & dosage , Magnetite Nanoparticles , Mice , Oxides/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...