Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
2.
JACC Asia ; 4(7): 536-544, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39101119

ABSTRACT

Background: Navitor, an intra-annular self-expanding heart valve (IA-SEV), is the third transcatheter heart valve introduced in Japan (in April 2022) as the next generation of the Portico valve ahead of other Asian countries. Objectives: The purpose of this study was to assess the patient-prosthesis mismatch (PPM) after IA-SEV implantation in Asian patients. Methods: All clinical data were collected from the database of an ongoing prospective Japanese multicenter registry (OCEAN-TAVI [Optimised Catheter Valvular Intervention transcatheter aortic valve implantation]). The primary endpoint was the rate of no PPM; the secondary endpoint included the rate of in-hospital mortality and hemodynamics after IA-SEV implantation. Results: A total of 463 patients (median age 86; 69.7% female) were enrolled in the registry. The percentages of implanted valves sized 23 mm, 25 mm, 27 mm, and 29 mm were 26.1% (n = 121), 41.7% (n = 193), 22.9% (n = 106), and 9.3% (n = 43), respectively. The primary endpoint of no PPM was achieved in 91.7% of the entire cohort and in 87.3%, 94.2%, 91.4%, and 93.0% of each valve size. The rate of in-hospital mortality was 1.9%. Postprocedural mean pressure gradient was 8.3 ± 4.3 mm Hg. The overall rate of pacemaker implantation was 9.7%; the incidence of pacemaker rate tended to be reduced when dividing the first and second half of operator experiences (13.0% vs. 8.0%; P = 0.08). Conclusions: The initial results for the IA-SEV were excellent regarding hemodynamics and reduction of paravalvular leakage regardless of valve size. The IA-SEV is a useful transcatheter heart valve, especially for Asian patients with a high prevalence of small annulus.

3.
Eur Heart J Case Rep ; 8(5): ytae211, 2024 May.
Article in English | MEDLINE | ID: mdl-38715626

ABSTRACT

Background: There is limited evidence regarding the optimal strategy for treating patients with acute decompensated heart failure complicated by severe left ventricular dysfunction, functional mitral regurgitation (FMR), and atrial septal defect (ASD) that cannot be controlled despite optimal medical treatment. Case summary: A 72-year-old man with non-ischaemic cardiomyopathy presented with acute heart failure and recurrent atrial fibrillation. An electrocardiogram after electrical cardioversion revealed left bundle block with QRS duration of 152 ms. Transthoracic echocardiography revealed severe left ventricular dysfunction, severe FMR, and a left-to-right shunt through an iatrogenic ASD (IASD). Despite initial optimal medical therapy for heart failure, the patient's condition was not completely controlled. After a discussion among the heart team, we performed cardiac resynchronization therapy (CRT) as the next strategy. Two weeks after CRT device implantation, heart failure was controlled, with improvement in cardiac function and FMR. The left-to-right shunts through the IASD also improved. Discussion: When treating decompensated heart failure with complicated pathophysiologies, it is crucial to prioritize the predominant pathophysiological factor and engage in thorough discussions with the heart team regarding the most appropriate intervention.

4.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
5.
Am J Cardiol ; 223: 156-164, 2024 07 15.
Article in English | MEDLINE | ID: mdl-38797196

ABSTRACT

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Postoperative Complications , Prosthesis Design , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Cause of Death/trends , Follow-Up Studies , Heart Failure , Incidence , Postoperative Complications/epidemiology , Propensity Score , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38660100

ABSTRACT

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

7.
Open Heart ; 11(1)2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38417913

ABSTRACT

OBJECTIVES: The clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS) and concomitant active cancer remain insufficiently explored. This study aimed to assess the midterm outcomes of TAVR in patients diagnosed with AS and active cancer. METHODS: Data from the OCEAN-TAVI, a prospective Japanese registry of TAVR procedures, was analysed to compare prognoses and clinical outcomes in patients with and without active cancer at the time of TAVR. RESULTS: Of the 2336 patients who underwent TAVR from October 2013 to July 2017, 89 patients (3.8%) had active cancer, whereas 2247 did not. Among patients with active cancer, 49 had limited-stage cancer (stage 1 or 2). The prevalent cancers identified before TAVR were colon (21%), prostate (18%), lung (15%), liver (11%) and breast (9%). Although the periprocedural complications and 30-day mortality rates were comparable between the groups, the 3-year survival rate after TAVR was notably lower in patients with active cancer (64.7%) than in those without active cancer (74.7%; p=0.016). Nevertheless, the 3-year survival rate of patients with limited-stage cancer (stage 1 or 2) did not significantly differ from those without cancer (70.6% vs 74.7%, p=0.50). CONCLUSIONS: The patients with active cancer exhibited significantly reduced midterm survival rates. However, no distinct disparity existed in those with limited-stage cancer (stage 1 or 2). Although TAVR is a viable treatment in patients with AS with active cancer, the type and stage of cancer and prognosis should be carefully weighed in the decision-making process.


Subject(s)
Aortic Valve Stenosis , Neoplasms , Transcatheter Aortic Valve Replacement , Male , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Prospective Studies , Time Factors , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Neoplasms/diagnosis
8.
J Cardiol Cases ; 29(1): 23-26, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38188318

ABSTRACT

The efficacy and risk of a combination of veno-arterial extracorporeal membrane oxygenation and Impella (Abiomed, Inc., Danvers, MA, USA), an approach known as ECPELLA, for post-infarction cardiac rupture is unclear. We describe the case of a 72-year-old man who presented with acute myocardial infarction. The patient was managed with ECPELLA because of hemodynamic compromise. One week later, there was a sudden increase in venous oxygen saturation. Transthoracic echocardiography revealed ventricular septal rupture, and free wall rupture. Intraventricular thrombus was also observed despite standard anticoagulation therapy. Even with double cardiac rupture, ECPELLA could facilitate left ventricular unloading and sustain hemodynamics. However, because of the risk of device failure due to thrombus aspiration into the Impella, the patient underwent repair surgery. Postoperatively, the patient was temporarily weaned off ECPELLA, and his hemodynamics deteriorated again, and he finally died. Learning objectives: ECPELLA can effectively stabilize the hemodynamics in cases of post-infarction cardiac rupture. However, there are still challenges to address, such as determining optimal ventricular reloading and ECPELLA management for intraventricular thrombus prevention. When using ECPELLA to delay surgery for post-infarction cardiac rupture, it is crucial to strike a balance between hemodynamic stabilization and avoiding potential serious complications.

SELECTION OF CITATIONS
SEARCH DETAIL