1.
Dent Mater ; 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39095246

ABSTRACT

OBJECTIVES: This multicenter study aimed to evaluate visual-instrumental agreement of six color measurement devices and optimize three color difference equations using a dataset of visual color differences (∆V) from expert observers. METHODS: A total of 154 expert observers from 16 sites across 5 countries participated, providing visual scaling on 26 sample pairs of artificial teeth using magnitude estimation. Three color difference equations (ΔE*ab, ∆E00, and CAM16-UCS) were tested. Optimization of all three equations was performed using device-specific weights, and the standardized residual sum of squares (STRESS) index was used to evaluate visual-instrumental agreement. RESULTS: The ΔE*ab formula exhibited STRESS values from 18 to 40, with visual-instrumental agreement between 60 % and 82 %. The ∆E00 formula showed STRESS values from 26 to 32, representing visual-instrumental agreement of 68 % to 74 %. CAM16-UCS demonstrated STRESS values from 32 - 39, with visual-instrumental agreement between 61-68 %. Following optimization, STRESS values decreased for all three formulas, with ΔE' demonstrating average visual-instrumental agreement of 79 % and ∆E00 of 78 %. CAM16-UCS showed average visual-instrumental agreement of 76 % post optimization. SIGNIFICANCE: Optimization of color difference equations notably improved visual-instrumental agreement, overshadowing device performance. The optimzed ΔE' formula demonstrated the best overall performance combining computational simplicty with outstanding visual-instrumental agreement.

2.
J Biomed Mater Res A ; 112(9): 1376-1387, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38251807

ABSTRACT

To date, it is unknown whether 3D printed fixed oral implant-supported prostheses can achieve comparable soft tissue integration (STI) to clinically established subtractively manufactured counterparts. STI is mediated among others by gingival fibroblasts (GFs) and is modulated by biomaterial surface characteristics. Therefore, the aim of the present work was to investigate the GF response of a 3D printed methacrylate photopolymer and a hybrid ceramic-filled methacrylate photopolymer for fixed implant-supported prostheses in the sense of supporting an STI. Subtractively manufactured samples made from methacrylate polymer and hybrid ceramic were evaluated for comparison and samples from yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), comprising well documented biocompatibility, served as control. Surface topography was analyzed by scanning electron microscopy and interferometry, elemental composition by energy-dispersive x-ray spectroscopy, and wettability by contact angle measurement. The response of GFs obtained from five donors was examined in terms of membrane integrity, adhesion, morphogenesis, metabolic activity, and proliferation behavior by a lactate-dehydrogenase assay, fluorescent staining, a resazurin-based assay, and DNA quantification. The results revealed all surfaces were smooth and hydrophilic. GF adhesion, metabolic activity and proliferation were impaired by 3D printed biomaterials compared to subtractively manufactured comparison surfaces and the 3Y-TZP control, whereas membrane integrity was comparable. Within the limits of the present investigation, it was concluded that subtractively manufactured surfaces are superior compared to 3D printed surfaces to support STI. For the development of biologically optimized 3D printable biomaterials, consecutive studies will focus on the improvement of cytocompatibility and the synthesis of STI-relevant extracellular matrix constituents.


Subject(s)
Biocompatible Materials , Fibroblasts , Gingiva , Printing, Three-Dimensional , Fibroblasts/cytology , Fibroblasts/drug effects , Fibroblasts/metabolism , Humans , Gingiva/cytology , Biocompatible Materials/chemistry , Cell Proliferation/drug effects , Cells, Cultured , Cell Adhesion/drug effects , Wettability , Dental Implants , Materials Testing , Surface Properties , Methacrylates/chemistry , Methacrylates/pharmacology
3.
J Funct Biomater ; 14(12)2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38132821

ABSTRACT

The purpose of the present study was to assess the fracture resistance of a two-piece alumina-toughened zirconia implant system with a carbon-reinforced PEEK abutment screw. METHODS: Thirty-two implants with screw-retained zirconia abutments were divided into four groups of eight samples each. Group 0 (control group) was neither loaded nor aged in a chewing simulator; group H was hydrothermally aged; group L was loaded with 98 N; and group HL was subjected to both hydrothermal aging and loading in a chewing simulator. One sample of each group was evaluated for t-m phase transformation, and the others were loaded until fracture. A one-way ANOVA was applied to evaluate differences between the groups. RESULTS: No implant fracture occurred during the artificial chewing simulation. Furthermore, there were no statistically significant differences (p > 0.05) between the groups in terms of fracture resistance (group 0: 783 ± 43 N; group H: 742 ± 43 N; group L: 757 ± 86 N; group HL: 740 ± 43 N) and bending moment (group 0: 433 ± 26 Ncm; group H: 413 ± 23 Ncm; group L: 422 ± 49 Ncm; group HL: 408 ± 27 Ncm). CONCLUSIONS: Within the limitations of the present investigation, it can be concluded that artificial loading and hydrothermal aging do not reduce the fracture resistance of the investigated implant system.