Eye (Lond) ; 38(9): 1702-1706, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38454172

ABSTRACT

BACKGROUND/OBJECTIVES: The aim of this study was to investigate whether the use of the silicone tipped irrigation/aspiration (I/A) handpiece CapsuleGuard® (Bausch + Lomb, Laval, Canada) reduced rates of posterior capsule rupture (PCR) during cataract surgery. METHODS: Royal College of Ophthalmologists' National Ophthalmology Database (NOD) Cataract Audit data from 01/04/2010 and 31/03/2021 and Bausch + Lomb sales figures were combined to identify centres participating in national cataract audit who have routinely adopted the silicone tipped I/A handpiece, CapsuleGuard®. Data were included only from centres with eligible cataract operations recorded on the NOD both before and after adopting CapsuleGuard®. Review of the literature was undertaken to estimate the proportion of PCR that occurs during I/A, to evaluate the impact of adoption of CapsuleGuard® on PCR occurring in this phase of surgery. RESULTS: Within the study period, 267 371 eligible cataract operations were performed in 14 centres with >50 eligible operations both before and after adopting CapsuleGuard®. Within centres adopting CapsuleGuard®, the rate of PCR occurrence reduction was 16.4%. Before and after the adoption of CapsuleGuard® the median change of PCR was 21.7% reduction (IQR: 4.8% to 37.7% reduction). CONCLUSIONS: A reduction in the rate of PCR was seen after regular adoption of CapsuleGuard® during cataract operations. Review of published studies attributing PCR to various components of the cataract operation suggest around 25% of PCR may occur during I/A; adoption of CapsuleGuard may, therefore, be associated with avoidance of a substantial proportion of the PCR during that phase of surgery.


Subject(s)
Cataract Extraction , Databases, Factual , Ophthalmology , Posterior Capsular Rupture, Ocular , Humans , Cataract Extraction/statistics & numerical data , Posterior Capsular Rupture, Ocular/epidemiology , Posterior Capsular Rupture, Ocular/etiology , Ophthalmology/statistics & numerical data , Male , United Kingdom/epidemiology , Female , Therapeutic Irrigation/statistics & numerical data , Aged
2.
Eye (Lond) ; 38(7): 1386-1389, 2024 May.
Article in English | MEDLINE | ID: mdl-38200322

ABSTRACT

BACKGROUND: Cataract surgical safety has improved over recent decades, with endophthalmitis rates before 2006 typically 0.13-0.15% compared with the most recent UK national estimate of 0.02%. There remains, however, substantial variation in reported rates from different centres. Due to the low event rate, this disparity may not be noticed and opportunities to improve therefore be missed. We propose a method of monitoring post-cataract endophthalmitis rates that would help centres with higher rates identify this. METHODS: A statistical tool, available to download or use online, permits comparison of local endophthalmitis rate with the estimated UK rate of 0.02%. Centres are encouraged to maintain a register of endophthalmitis cases, and when the number reaches a threshold (X cases), either in a certain time period or in a fixed number of procedures, then the centre can consider itself as an outlier and trigger local investigations to improve infection control. RESULTS: Example outputs are offered, such as for a unit doing 5000 cataracts annually, a value of X is suggested such that the third case of endophthalmitis (X = 3) in a 12-month period would give 85% confidence, the fourth case 90% confidence and the fifth case 95% confidence that the true endophthalmitis rate for that unit was higher than the national average. CONCLUSIONS: This statistical tool provides a basis for units to set a threshold number of cases of endophthalmitis within a given period that would trigger local processes, thus helping inform local monitoring processes for this rare but potentially catastrophic complication of cataract surgery.


Subject(s)
Cataract Extraction , Databases, Factual , Endophthalmitis , Ophthalmology , Humans , Endophthalmitis/epidemiology , Endophthalmitis/prevention & control , Endophthalmitis/etiology , Cataract Extraction/adverse effects , Cataract Extraction/statistics & numerical data , United Kingdom/epidemiology , Ophthalmology/statistics & numerical data , Postoperative Complications/epidemiology , Societies, Medical
4.
BMJ Open ; 12(8): e053560, 2022 08 19.
Article in English | MEDLINE | ID: mdl-35985773

ABSTRACT

OBJECTIVES: To describe the relationships between axial length and intraoperative complications in patients undergoing cataract surgery. DESIGN: Cohort analysis of the Royal College of Ophthalmologists' National Ophthalmology Database (RCOphth NOD). SETTING: 110 National Health Service Trusts in England, Health Boards in Wales, Independent Sector Treatment Centres and Guernsey. PARTICIPANTS: 820 354 patients, aged 18 years or older, undergoing cataract surgery. Eligible operations were those from centres with at least 50 operations with a recorded axial length measurement and age at surgery between 1 April 2010 and 31 August 2019. INTERVENTIONS: Phacoemulsification where the primary intention was cataract surgery alone. OUTCOME MEASURES: Posterior capsule rupture (PCR) and other recorded intraoperative complications. RESULTS: 1 211 520 eligible operations were performed by 3210 surgeons. The baseline axial length was <21 mm (short eyes) for 17 170 (1.4%) eyes, 21-28 mm (medium eyes) for 1 182 513 (97.6%) eyes and >28 mm (long eyes) for 11 837 (1.0%) eyes. The median age at surgery was younger for patients with long eyes than those with short or medium eyes. The rate of any intraoperative complication was higher for short eyes than medium or long with complication rates of 4.5%, 2.9% and 3.3%, respectively (p<0.001). PCR occurred in 1.40% surgeries overall, and in 1.53%, 1.40% and 1.61% of short, medium and long eyes, respectively (p=0.043, not significant at the 1% level). CONCLUSIONS: Overall PCR rates for cataract surgery in RCOphth NOD contributing centres are lower than previously reported and there is little change in PCR rates by axial length. Short eyes were more likely to have an intraoperative complication than medium or long eyes.


Subject(s)
Cataract Extraction , Cataract , Ophthalmologists , Ophthalmology , Phacoemulsification , Cataract/epidemiology , Cataract Extraction/adverse effects , Cohort Studies , Humans , Intraoperative Complications/epidemiology , Intraoperative Complications/etiology , Retrospective Studies , State Medicine , Visual Acuity