1.
Molecules ; 26(4)2021 Feb 20.
Article in English | MEDLINE | ID: mdl-33672446

ABSTRACT

Over the past decade, reckless usage of synthetic pesticides and fertilizers in agriculture has made the environment and human health progressively vulnerable. This setting leads to the pursuit of other environmentally friendly interventions. Amongst the suggested solutions, the use of chitin and chitosan came about, whether alone or in combination with endophytic bacterial strains. In the framework of this research, we reported an assortment of studies on the physico-chemical properties and potential applications in the agricultural field of two biopolymers extracted from shrimp shells (chitin and chitosan), in addition to their uses as biofertilizers and biostimulators in combination with bacterial strains of the genus Bacillus sp. (having biochemical and enzymatic properties).


Subject(s)
Bacillus/metabolism , Chitin/metabolism , Chitosan/metabolism , Crops, Agricultural/metabolism , Animal Shells/chemistry , Animals , Carbohydrate Conformation , Chitin/chemistry , Chitin/isolation & purification , Chitosan/chemistry , Chitosan/isolation & purification , Crustacea
2.
Afr Health Sci ; 15(2): 641-6, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26124815

ABSTRACT

BACKGROUND: Although high-performance liquid chromatography (HPLC) is the commonly used method for the analysis of retinol in biological samples, simple and rapid test kits are available. OBJECTIVES: This study compared a rapid test kit (ICHECK Fluoro®) to HPLC for the assessment of serum retinol concentrations. METHODS: For the analysis by HPLC, sample preparation included standard deproteinization and extraction phases. The analysis by ICHECK was performed by injecting serum into IEX reagent vials (n=89) and mixing manually for separation. After precipitation of the proteins, the vial was introduced into the chamber of the ICHECK Fluoro and analysed at 0 min (ICHECK0min) and 15 min later (ICHECK15min). Bland and Altman approach was applied to test the agreement between HPLC and ICHECK. RESULTS: Mean HPLC, ICHECK0min and ICHECK15min values were 421.2±106.0 µg/L, 423.1±118.3 µg/L and 413.2±107.6 µg/L, respectively. Retinol concentrations significantly decreased in the IEX solution over time (p<0.001). No significant proportional bias was observed between HPLC and ICHECK0min (r-0.038, p=0.73) and ICHECK15min (r=-0.024, p=0.82). Fixed biases (HPLC minus ICHECK) for ICHECK0min and ICHECK15min were respectively -1.9±23.1 µg/l (p=0.45) and 8.0±22.7 µg/l (p=0.002). CONCLUSION: ICHECK Fluoro may offer a reliable mean for assessing serum retinol for measurements performed with no significant time delay.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fluorometry/instrumentation , Vitamin A/blood , Child , Female , Humans , Longitudinal Studies , Male , Morocco , Reproducibility of Results , Rural Population , Sensitivity and Specificity , Vitamin A/analysis , Vitamin A Deficiency/blood