Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(5): e0302840, 2024.
Article in English | MEDLINE | ID: mdl-38713676

ABSTRACT

Malaria rapid diagnostic test (mRDT) kit is one of the techniques for diagnosing malaria. Due to its inherent advantages over the microscopy technique, several brands of the kit have flooded malaria endemic countries, without prior in-country evaluation. Two of such mRDT kits are Oscar (India) and Standard Q (Korea Republic). In this study, the performance of Oscar and Standard Q mRDT kits were compared to First Response (India) and CareStart (USA) mRDTs, which have been evaluated and deployed for use approved by the Ministry of Health (MOH). In this comparative study, whole blood samples were collected from patients suspected of malaria. Plasmodium falciparum was detected in each sample using nested polymerase chain reaction (nPCR), microscopy and the four mRDTs. The sensitivities, specificities, accuracies, positive and negative predictive values and accuracies of the mRDTs were determined using nPCR as a reference technique. Kappa statistic was used to determine the level of agreement among the techniques. Two hundred (200) blood samples were analyzed in this study. The overall detection rates of P. falciparum by microscopy, First Response, CareStart, Oscar-PfHRP2, Standard Q mRDT kits and nPCR were 31.5%, 34.5%, 33.5%, 32%, 31% and 43% (x2 = 6.1, p = 0.046), respectively. The accuracies of CareStart and First Response were comparable (90.5% vs. 89.5%). Further, comparing their sensitivities, Oscar-PfHRP2 was 74.4% (95% confidence interval (CI): 63.9-83.2) while that of Standard Q was 72.1% (95% CI: 61.4-81.2), with comparable accuracies (Oscar-PfHRP2-89% and Standard Q -88%). Apart from First Response that was 98.3% specific, the others were 100% specific. Kappa test revealed perfect diagnostic agreement (κ = 0.90-0.98) among the four mRDTs. That notwithstanding, Oscar-PfHRP2 agreed better with CareStart (κ = 0.94) and First Response (κ = 0.92) compared to the agreement between Standard Q and, CareStart (κ = 0.92) and First Response (κ = 0.90). Taken together, the diagnostic performance of the four mRDT kits were statistically similar. That notwithstanding, new mRDT kits should be evaluated prior to deployment for use.


Subject(s)
Diagnostic Tests, Routine , Malaria, Falciparum , Plasmodium falciparum , Reagent Kits, Diagnostic , Sensitivity and Specificity , Humans , Reagent Kits, Diagnostic/standards , Plasmodium falciparum/isolation & purification , Plasmodium falciparum/genetics , Malaria, Falciparum/diagnosis , Malaria, Falciparum/parasitology , Malaria, Falciparum/blood , Ghana , Diagnostic Tests, Routine/methods , Female , Male , Adult , Child , Adolescent , Middle Aged , Child, Preschool , Young Adult , Antigens, Protozoan/blood , Polymerase Chain Reaction/methods , Microscopy/methods , Infant , Rapid Diagnostic Tests
2.
PLoS One ; 17(10): e0275052, 2022.
Article in English | MEDLINE | ID: mdl-36201568

ABSTRACT

In this study, Plasmodium falciparum was detected in patients that were declared negative for malaria microscopy and rapid diagnostic test kit (mRDT), using Plasmodium 18s rRNA loop-mediated isothermal amplification (LAMP) technique. The main aim of this study was to assess the usefulness of LAMP assay for detecting pre-clinical malaria, when microscopy and mRDT were less sensitive. DNA was obtained from 100 µL of whole blood using the boil and spin method. Subsequently, the Plasmodium 18s rRNA LAMP assay was performed to amplify the specific Plasmodium 18s rRNA gene. Microscopy and mRDT negative samples [697/2223 (31.2%)] were used for this study. Compared to frequencies obtained for the other demographic variables, most of the patients were < 6 years (37.7%), females (59.0%), peri-urban dwellers (39.0%) and patients that sought outpatient department services (39.3%). Overall, the prevalence of Plasmodium 18s rRNA was 17.5%. when stratified by study variables, Plasmodium 18s rRNA LAMP positivity was higher in patients over 30 years [58/122 (54.2%)], males [69/122 (56.5%)], rural dwellers [69/122 (56.5%)] and patients that sought OPD services [68/122 (55.7%)]. The risk of being infected with Plasmodium when routine tests were negative was higher in 15-30-year group (OR = 3.03, 95% CI: 1.6-5.8, p = 0.0007), patients > 30 years (OR = 15.2, 95% CI: 8.3-27.7, p<0.001), males (OR = 2.1, 95% CI: 1.4-3.2, p = 0.0002) and rural dwellers (OR = 2.2, 95% CI:1.4-3.6, p = 0.0009). However, risk was lower in post-natal children (OR = 0.3, 95% CI: 0.18-0.51, p<0.001). Majority (81.5%) of the infected patients presented with headache, herpes labialis, diarrhea and vomiting. We demonstrated the lack of sensitivities of microscopy and mRDT for one-time diagnosis of malaria. Therefore, it is essential to utilize a sensitive technique such as Plasmodium 18s rRNA LAMP to increase the detection rate of Plasmodium infection.


Subject(s)
Malaria, Falciparum , Malaria , Plasmodium , Child , Diagnostic Tests, Routine/methods , Female , Humans , Malaria/diagnosis , Malaria, Falciparum/diagnosis , Male , Microscopy , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques/methods , Plasmodium/genetics , Plasmodium falciparum/genetics , RNA, Ribosomal, 18S/genetics , Reagent Kits, Diagnostic , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...