Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add more filters










Publication year range
1.
J Expo Sci Environ Epidemiol ; 33(4): 548-557, 2023 07.
Article in English | MEDLINE | ID: mdl-35449448

ABSTRACT

BACKGROUND: Differential risks for adverse pregnancy outcomes may be influenced by prenatal chemical exposures, but current exposure methods may not fully capture data to identify harms and differences. METHODS: We collected maternal and cord sera from pregnant people in Fresno and San Francisco, and screened for over 2420 chemicals using LC-QTOF/MS. We matched San Francisco participants to Fresno participants (N = 150) and compared detection frequencies. Twenty-six Fresno participants wore silicone wristbands evaluated for over 1500 chemicals using quantitative chemical analysis. We assessed whether living in tracts with higher levels of pollution according to CalEnviroScreen correlated with higher numbers of chemicals detected in sera. RESULTS: We detected 2167 suspect chemical features across maternal and cord sera. The number of suspect chemical features was not different by city, but a higher number of suspect chemicals in cosmetics or fragrances was detected in the Fresno versus San Francisco participants' sera. We also found high levels of chemicals used in fragrances measured in the silicone wristbands. Fresno participants living in tracts with higher pesticide scores had higher numbers of suspect pesticides in their sera. CONCLUSIONS: Multiple exposure-assessment approaches can identify exposure to many chemicals during pregnancy that have not been well-studied for health effects.


Subject(s)
Environmental Monitoring , Pesticides , Pregnancy , Female , Humans , Environmental Monitoring/methods , Silicones , Environmental Exposure/analysis , Pesticides/analysis , California
2.
R Soc Open Sci ; 9(9): 220453, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36133150

ABSTRACT

Atlantic herring in International Council for Exploration of the Sea (ICES) Divisions 6.a, 7.b-c comprises at least three populations, distinguished by temporal and spatial differences in spawning, which have until recently been managed as two stocks defined by geographical delineators. Outside of spawning the populations form mixed aggregations, which are the subject of acoustic surveys. The inability to distinguish the populations has prevented the development of separate survey indices and separate stock assessments. A panel of 45 single-nucleotide polymorphisms, derived from whole-genome sequencing, were used to genotype 3480 baseline spawning samples (2014-2021). A temporally stable baseline comprising 2316 herring from populations known to inhabit Division 6.a was used to develop a genetic assignment method, with a self-assignment accuracy greater than 90%. The long-term temporal stability of the assignment model was validated by assigning archive (2003-2004) baseline samples (270 individuals) with a high level of accuracy. Assignment of non-baseline samples (1514 individuals) from Divisions 6.a, 7.b-c indicated previously unrecognized levels of mixing of populations outside of the spawning season. The genetic markers and assignment models presented constitute a 'toolbox' that can be used for the assignment of herring caught in mixed survey and commercial catches in Division 6.a into their population of origin with a high level of accuracy.

3.
J Expo Sci Environ Epidemiol ; 32(2): 268-279, 2022 03.
Article in English | MEDLINE | ID: mdl-33953340

ABSTRACT

BACKGROUND: Silicone personal samplers are increasingly being used to measure chemical exposures, but many of these studies do not attempt to calculate environmental concentrations. OBJECTIVE: Using measurements of silicone wristband uptake of organic chemicals from atmospheric exposure, create log Ksa and ke predictive models based on empirical data to help develop air equivalency calculations for both volatile and semi-volatile organic compounds. METHODS: An atmospheric vapor generator and a custom exposure chamber were used to measure the uptake of organic chemicals into silicone wristbands under simulated indoor conditions. Log Ksa models were evaluated using repeated k-fold cross-validation. Air equivalency was compared between best-performing models. RESULTS: Log Ksa and log ke estimates calculated from uptake data were used to build predictive models from boiling point (BP) and other parameters (all models: R2 = 0.70-0.94). The log Ksa models were combined with published data and refined to create comprehensive and effective predictive models (R2: 0.95-0.97). Final estimates of air equivalency using novel BP models correlated well over an example dataset (Spearman r = 0.984) across 5-orders of magnitude (<0.05 to >5000 ng/L). SIGNIFICANCE: Data from silicone samplers can be translated into air equivalent concentrations that better characterize environmental concentrations associated with personal exposures and allow direct comparisons to regulatory levels.


Subject(s)
Air Pollutants , Volatile Organic Compounds , Air Pollutants/analysis , Environmental Monitoring , Humans , Silicones , Volatile Organic Compounds/analysis
4.
J Expo Sci Environ Epidemiol ; 27(6): 551-559, 2017 11.
Article in English | MEDLINE | ID: mdl-28745305

ABSTRACT

Wristbands are increasingly used for assessing personal chemical exposures. Unlike some exposure assessment tools, guidelines for wristbands, such as preparation, applicable chemicals, and transport and storage logistics, are lacking. We tested the wristband's capacity to capture and retain 148 chemicals including polychlorinated biphenyls (PCBs), pesticides, flame retardants, polycyclic aromatic hydrocarbons (PAHs), and volatile organic chemicals (VOCs). The chemicals span a wide range of physical-chemical properties, with log octanol-air partitioning coefficients from 2.1 to 13.7. All chemicals were quantitatively and precisely recovered from initial exposures, averaging 102% recovery with relative SD ≤21%. In simulated transport conditions at +30 °C, SVOCs were stable up to 1 month (average: 104%) and VOC levels were unchanged (average: 99%) for 7 days. During long-term storage at -20 °C up to 3 (VOCs) or 6 months (SVOCs), all chemical levels were stable from chemical degradation or diffusional losses, averaging 110%. Applying a paired wristband/active sampler study with human participants, the first estimates of wristband-air partitioning coefficients for PAHs are presented to aid in environmental air concentration estimates. Extrapolation of these stability results to other chemicals within the same physical-chemical parameters is expected to yield similar results. As we better define wristband characteristics, wristbands can be better integrated in exposure science and epidemiological studies.


Subject(s)
Air Pollutants/analysis , Environmental Monitoring/instrumentation , Flame Retardants/analysis , Pesticides/analysis , Polychlorinated Biphenyls/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Volatile Organic Compounds/analysis , Environmental Monitoring/methods , Female , Humans , Male , Wrist
5.
Environ Sci Technol ; 50(14): 7489-97, 2016 07 19.
Article in English | MEDLINE | ID: mdl-27391856

ABSTRACT

Passive sampling devices were used to measure air vapor and water dissolved phase concentrations of 33 polycyclic aromatic hydrocarbons (PAHs) and 22 oxygenated PAHs (OPAHs) at four Gulf of Mexico coastal sites prior to, during and after shoreline oiling from the Deepwater Horizon oil spill (DWH). Measurements were taken at each site over a 13 month period, and flux across the water-air boundary was determined. This is the first report of vapor phase and diffusive flux of both PAHs and OPAHs during the DWH. Vapor phase sum PAH and OPAH concentrations ranged between 6.6 and 210 ng/m(3) and 0.02 and 34 ng/m(3) respectively. PAH and OPAH concentrations in air exhibited different spatial and temporal trends than in water, and air-water flux of 13 individual PAHs was shown to be at least partially influenced by the DWH incident. The largest PAH volatilizations occurred at the sites in Alabama and Mississippi at nominal rates of 56 000 and 42 000 ng/m(2) day(-1) in the summer. Naphthalene was the PAH with the highest observed volatilization rate of 52 000 ng/m(2) day(-1) in June 2010. This work represents additional evidence of the DWH incident contributing to air contamination, and provides one of the first quantitative air-water chemical flux determinations with passive sampling technology.


Subject(s)
Environmental Monitoring , Water Pollutants, Chemical , Petroleum Pollution , Polycyclic Aromatic Hydrocarbons , Water
7.
Environ Sci Technol ; 50(15): 7964-72, 2016 08 02.
Article in English | MEDLINE | ID: mdl-27312518

ABSTRACT

Snowmelt, surface runoff, or stormwater releases in urban environments can result in significant discharges of particulate matter-bound polycyclic aromatic hydrocarbons (PAHs) into aquatic environments. Recently, more-specific activities such as road-tunnel washing have been identified as contributing to contaminant load to surface waters. However, knowledge of PAH accessibility in particulate matter (PM) of urban origin that may ultimately be released into urban surface waters is limited. In the present study, we evaluated the accessibility of PAHs associated with seven distinct (suspended) particulate matter samples collected from different urban sources. Laboratory-based infinite sink extractions with silicone rubber (SR) as the extractor phase demonstrated a similar pattern of PAH accessibility for most PM samples. Substantially higher accessible fractions were observed for the less-hydrophobic PAHs (between 40 and 80% of total concentrations) compared with those measured for the most-hydrophobic PAHs (<5% of total concentrations). When we focused on PAHs bound to PM from tunnel-wash waters, first-order desorption rates for PAHs with log Kow > 5.5 were found in line with those commonly found for slowly or very slowly desorbing sediment-associated contaminants. PAHs with log Kow < 5.5 were found at higher desorbing rates. The addition of detergents did not influence the extractability of lighter PAHs but increased desorption rates for the heavier PAHs, potentially contributing to increases in the toxicity of tunnel-wash waters when surfactants are used. The implications of total and accessible PAH concentrations measured in our urban PM samples are discussed in a context of management of PAH and PM emission to the surrounding aquatic environment. Although we only fully assessed PAHs in this work, further study should consider other contaminants such as OPAHs, which were also detected in all PM samples.


Subject(s)
Polycyclic Aromatic Hydrocarbons , Environmental Monitoring , Particulate Matter/analysis
8.
Environ Res ; 147: 365-72, 2016 May.
Article in English | MEDLINE | ID: mdl-26945619

ABSTRACT

Silicone wristbands can be used as passive sampling tools for measuring personal environmental exposure to organic compounds. Due to the lightweight and simple design, the wristband may be a useful technique for measuring children's exposure. In this study, we tested the stability of flame retardant compounds in silicone wristbands and developed an analytical approach for measuring 41 flame retardants in the silicone wristband in order to evaluate exposure to these compounds in preschool-aged children. To evaluate the robustness of using wristbands to measure flame retardants, we evaluated the stability of 3 polybrominated diphenyl ethers (BDEs), and 2 organophosphate flame retardants (OPFRs) in wristbands over 84 days and did not find any evidence of significant loss over time at either 4 or -20°C (p>0.16). We recruited a cohort of 92 preschool aged children in Oregon to wear the wristband for 7 days in order to characterize children's acceptance of the technology, and to characterize their exposure to flame retardants. Seventy-seven parents returned the wristbands for analysis of 35 BDEs, 4 OPFRs, and 2 other brominated flame retardants although 5 were excluded from the exposure assessment due to protocol deviations (n=72). A total of 20 compounds were detected above the limit of quantitation, and 11 compounds including 4 OPFRs and 7 BDEs were detected in over 60% of the samples. Children's gender, age, race, recruitment site, and family context were not significantly associated with returning wristbands or compliance with protocols. Comparisons between flame retardant data and socio-demographic information revealed significant differences in total exposures to both ΣBDEs and ΣOPFRs based on age of house, vacuuming frequency, and family context. These results demonstrate that preschool children in Oregon are exposed to BDEs that are no longer being produced in the United States and to OPFRs that have been used as an alternative to polybrominated compounds. Silicone wristbands were well tolerated by young children and were useful for characterizing personal exposure to flame retardants that were not bound to particulate matter.


Subject(s)
Environmental Monitoring/methods , Flame Retardants/analysis , Halogenated Diphenyl Ethers/analysis , Organophosphates/analysis , Child, Preschool , Female , Humans , Male , Socioeconomic Factors
9.
Environ Int ; 85: 182-8, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26408946

ABSTRACT

Silicone polymers are used for a wide array of applications from passive samplers in environmental studies, to implants used in human augmentation and reconstruction. If silicone sequesters toxicants throughout implantation, it may represent a history of exposure and potentially reduce the body burden of toxicants influencing the risk of adverse health outcomes such as breast cancer. Objectives of this research included identifying a wide variety of toxicants in human silicone implants, and measuring the in vivo absorption of contaminants into silicone and surrounding tissue in an animal model. In the first study, eight human breast implants were analyzed for over 1400 organic contaminants including consumer products, chemicals in commerce, and pesticides. A total of 14 compounds including pesticides such as trans-nonachlor (1.2-5.9ng/g) and p,p'-DDE (1.2-34ng/g) were identified in human implants, 13 of which have not been previously reported in silicone prostheses. In the second project, female ICR mice were implanted with silicone and dosed with p,p'-DDE and PCB118 by intraperitoneal injection. After nine days, silicone and adipose samples were collected, and all implants in dosed mice had p,p'-DDE and PCB118 present. Distribution ratios from silicone and surrounding tissue in mice compare well with similar studies, and were used to predict adipose concentrations in human tissue. Similarities between predicted and measured chemical concentrations in mice and humans suggest that silicone may be a reliable surrogate measure of persistent toxicants. More research is needed to identify the potential of silicone implants to refine the predictive quality of chemicals found in silicone implants.


Subject(s)
Adipose Tissue/chemistry , Breast Implants , Environmental Monitoring/methods , Pesticides/analysis , Silicones/analysis , Animals , Body Burden , Dichlorodiphenyl Dichloroethylene/analysis , Dichlorodiphenyl Dichloroethylene/pharmacokinetics , Female , Humans , Hydrocarbons, Chlorinated/analysis , Hydrocarbons, Chlorinated/pharmacokinetics , Mice , Mice, Inbred ICR , Pesticides/pharmacokinetics
10.
Environ Sci Technol ; 49(1): 141-9, 2015 Jan 06.
Article in English | MEDLINE | ID: mdl-25412353

ABSTRACT

Passive sampling devices were used to measure air vapor and water dissolved phase concentrations of 33 polycyclic aromatic hydrocarbons (PAHs) and 22 oxygenated PAHs (OPAHs) at four Gulf of Mexico coastal sites prior to, during, and after shoreline oiling from the Deepwater Horizon oil spill (DWH). Measurements were taken at each site over a 13 month period, and flux across the water-air boundary was determined. This is the first report of vapor phase and flux of both PAHs and OPAHs during the DWH. Vapor phase sum PAH and OPAH concentrations ranged between 1 and 24 ng/m(3) and 0.3 and 27 ng/m(3), respectively. PAH and OPAH concentrations in air exhibited different spatial and temporal trends than in water, and air-water flux of 13 individual PAHs were strongly associated with the DWH incident. The largest PAH volatilizations occurred at the sites in Alabama and Mississippi in the summer, each nominally 10,000 ng/m(2)/day. Acenaphthene was the PAH with the highest observed volatilization rate of 6800 ng/m(2)/day in September 2010. This work represents additional evidence of the DWH incident contributing to air contamination, and provides one of the first quantitative air-water chemical flux determinations with passive sampling technology.


Subject(s)
Air Pollutants/analysis , Petroleum Pollution/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Water Pollutants, Chemical/analysis , Air Pollutants/chemistry , Alabama , Environmental Monitoring , Mississippi , Oxygen/chemistry , Polycyclic Aromatic Hydrocarbons/chemistry , Seasons , Southeastern United States , Volatilization , Water , Water Pollutants, Chemical/chemistry
11.
Environ Pollut ; 193: 71-78, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25009960

ABSTRACT

Sequestering semi-polar compounds can be difficult with low-density polyethylene (LDPE), but those pollutants may be more efficiently absorbed using silicone. In this work, optimized methods for cleaning, infusing reference standards, and polymer extraction are reported along with field comparisons of several silicone materials for polycyclic aromatic hydrocarbons (PAHs) and pesticides. In a final field demonstration, the most optimal silicone material is coupled with LDPE in a large-scale study to examine PAHs in addition to oxygenated-PAHs (OPAHs) at a Superfund site. OPAHs exemplify a sensitive range of chemical properties to compare polymers (log Kow 0.2-5.3), and transformation products of commonly studied parent PAHs. On average, while polymer concentrations differed nearly 7-fold, water-calculated values were more similar (about 3.5-fold or less) for both PAHs (17) and OPAHs (7). Individual water concentrations of OPAHs differed dramatically between silicone and LDPE, highlighting the advantages of choosing appropriate polymers and optimized methods for pollutant monitoring.


Subject(s)
Environmental Monitoring/instrumentation , Polycyclic Aromatic Hydrocarbons/analysis , Polyethylene/chemistry , Silicones/chemistry , Water Pollutants, Chemical/analysis
13.
Environ Sci Technol ; 48(6): 3327-35, 2014 Mar 18.
Article in English | MEDLINE | ID: mdl-24548134

ABSTRACT

Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual's exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposure with silicone wristbands as personal passive samplers. Laboratory methodology affecting precleaning, infusion, and extraction were developed from commercially available silicone, and chromatographic background interference was reduced after solvent cleanup with good extraction efficiency (>96%). After finalizing laboratory methods, 49 compounds were sequestered during an ambient deployment which encompassed a diverse set of compounds including polycyclic aromatic hydrocarbons (PAHs), consumer products, personal care products, pesticides, phthalates, and other industrial compounds ranging in log K(ow) from -0.07 (caffeine) to 9.49 (tris(2-ethylhexyl) phosphate). In two hot asphalt occupational settings, silicone personal samplers sequestered 25 PAHs during 8- and 40-h exposures, as well as 2 oxygenated-PAHs (benzofluorenone and fluorenone) suggesting temporal sensitivity over a single work day or week (p < 0.05, power =0.85). Additionally, the amount of PAH sequestered differed between worksites (p < 0.05, power = 0.99), suggesting spatial sensitivity using this novel application.


Subject(s)
Environmental Monitoring/instrumentation , Environmental Pollutants/analysis , Occupational Exposure/analysis , Silicones/chemistry , Environmental Monitoring/methods , Humans , Pesticides/analysis , Polycyclic Aromatic Hydrocarbons/analysis
14.
Environ Toxicol Chem ; 33(1): 177-81, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24123227

ABSTRACT

The authors investigated coupling passive sampling technologies with ultraviolet irradiation experiments to study polycyclic aromatic hydrocarbon (PAH) and oxygenated PAH transformation processes in real-world bioavailable mixtures. Passive sampling device (PSD) extracts were obtained from coastal waters impacted by the Deepwater Horizon oil spill and Superfund sites in Portland, Oregon, USA. Oxygenated PAHs were found in the contaminated waters with our PSDs. All mixtures were subsequently exposed to a mild dose of ultraviolet B (UVB). A reduction in PAH levels and simultaneous formation of several oxygenated PAHs were measured. Site-specific differences were observed with UVB-exposed PSD mixtures.


Subject(s)
Environmental Monitoring/methods , Polycyclic Aromatic Hydrocarbons/analysis , Ultraviolet Rays , Water Pollutants, Chemical/analysis , Environmental Monitoring/instrumentation , Gulf of Mexico , Oregon , Oxygen/chemistry , Petroleum Pollution , Photolysis , Polycyclic Aromatic Hydrocarbons/chemistry , Polycyclic Aromatic Hydrocarbons/radiation effects , Water Pollutants, Chemical/chemistry , Water Pollutants, Chemical/radiation effects
15.
Anal Bioanal Chem ; 405(27): 8885-96, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24005604

ABSTRACT

We developed two independent approaches for separation and quantitation of 24 oxygenated polycyclic aromatic hydrocarbons (OPAHs) using both liquid chromatography-atmospheric pressure chemical ionization/mass spectrometry (LC-APCI/MS) and gas chromatography-electron impact/mass spectrometry (GC-EI/MS). Building on previous OPAH research, we examined laboratory stability of OPAHs, improved existing method parameters, and compared quantification strategies using standard addition and an internal standard on an environmental sample. Of 24 OPAHs targeted in this research, 19 compounds are shared between methods, with 3 uniquely quantitated by GC-EI/MS and 2 by LC-APCI/MS. Using calibration standards, all GC-EI/MS OPAHs were within 15 % of the true value and had less than 15 % relative standard deviations (RSDs) for interday variability. Similarly, all LC-APCI/MS OPAHs were within 20 % of the true value and had less than 15 % RSDs for interday variability. Instrument limits of detection ranged from 0.18 to 36 ng mL(-1) on the GC-EI/MS and 2.6 to 26 ng mL(-1) on the LC-APCI/MS. Four standard reference materials were analyzed with each method, and we report some compounds not previously published in these materials, such as perinaphthenone and xanthone. Finally, an environmental passive sampling extract from Portland Harbor Superfund, OR was analyzed by each method using both internal standard and standard addition to compensate for potential matrix effects. Internal standard quantitation resulted in increased precision with similar accuracy to standard addition for most OPAHs using 2-fluoro-fluorenone-(13)C as an internal standard. Overall, this work improves upon OPAH analytical methods and provides some considerations and strategies for OPAHs as focus continues to expand on this emerging chemical class.


Subject(s)
Chromatography, Liquid/standards , Environmental Pollutants/isolation & purification , Gas Chromatography-Mass Spectrometry/standards , Polycyclic Aromatic Hydrocarbons/isolation & purification , Atmospheric Pressure , Calibration , Observer Variation , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Solutions
16.
Anal Bioanal Chem ; 404(9): 2683-92, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22476786

ABSTRACT

Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.


Subject(s)
Carboxylic Acids/analysis , Environmental Monitoring/standards , Environmental Pollutants/analysis , Fluorocarbons/analysis , Sulfonamides/analysis , Animals , Bivalvia/metabolism , Cattle , Environmental Monitoring/methods , Fishes/metabolism , Liver/metabolism , Reference Standards
17.
Environ Toxicol Chem ; 31(6): 1223-30, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22447337

ABSTRACT

The authors compared blood plasma concentrations of 13 perfluoroalkyl contaminants (PFCs) in five sea turtle species with differing trophic levels. Wild sea turtles were blood sampled from the southeastern region of the United States, and plasma was analyzed using liquid chromatography tandem mass spectrometry. Mean concentrations of perfluorooctane sulfonate (PFOS), the predominant PFC, increased with trophic level from herbivorous greens (2.41 ng/g), jellyfish-eating leatherbacks (3.95 ng/g), omnivorous loggerheads (6.47 ng/g), to crab-eating Kemp's ridleys (15.7 ng/g). However, spongivorous hawksbills had surprisingly high concentrations of PFOS (11.9 ng/g) and other PFCs based on their trophic level. These baseline concentrations of biomagnifying PFCs demonstrate interesting species and geographical differences. The measured PFOS concentrations were compared with concentrations known to cause toxic effects in laboratory animals, and estimated margins of safety (EMOS) were calculated. Small EMOS (<100), suggestive of potential risk of adverse health effects, were observed for all five sea turtle species for immunosuppression. Estimated margins of safety less than 100 were also observed for liver, thyroid, and neurobehavorial effects for the more highly exposed species. These baseline concentrations and the preliminary EMOS exercise provide a better understanding of the potential health risks of PFCs for conservation managers to protect these threatened and endangered species.


Subject(s)
Environmental Monitoring , Fluorocarbons/blood , Turtles/blood , Water Pollutants, Chemical/blood , Alkanesulfonic Acids/analysis , Alkanesulfonic Acids/blood , Animals , Endangered Species , Female , Fluorocarbons/analysis , United States , Water Pollutants, Chemical/analysis
18.
Environ Sci Technol ; 45(19): 8129-36, 2011 Oct 01.
Article in English | MEDLINE | ID: mdl-21309595

ABSTRACT

Wildlife from remote locations have been shown to bioaccumulate perfluorinated compounds (PFCs) in their tissues. Twelve PFCs, consisting of perfluorinated carboxylic (PFCA) and sulfonic (PFSA) acids as well as the perfluorooctane sulfonate (PFOS) precursor perfluorooctane sulfonamide (PFOSA), were measured in livers of 68 beluga whales (Delphinapterus leucas) collected from two subpopulations, Cook Inlet and eastern Chukchi Sea, in Alaska between 1989 and 2006. PFOS and PFOSA were the dominant compounds measured in both beluga stock populations, with overall median concentrations of 10.8 ng/g and 22.8 ng/g, respectively. Long-chain perfluorocarboxylates, PFCAs (9 to 14 carbons), were detected in more than 80% of the samples. Perfluoroundecanoic acid (PFUnA) and perfluorotridecanoic acid (PFTriA) made up a large percentage of the PFCAs measured with median concentrations of 8.49 ng/g and 4.38 ng/g, respectively. To compare differences in location, year, sex, and length, backward stepwise multiple regression models of the individual and total PFC concentrations were used. Spatially, the Cook Inlet belugas had higher concentrations of most PFCAs and PFOS (p < 0.05); however, these belugas had a lower median concentration of PFOSA when compared to belugas from the eastern Chukchi Sea (p < 0.05). Temporal trends indicated most PFCAs, PFHxS, PFOS, and PFOSA concentrations increased from 1989 to 2006 (p < 0.05). Males had significantly higher concentrations of PFTriA, ΣPFCA, and PFOS (p < 0.05). Perfluorononanic acid (PFNA) and PFOS showed a significant decrease in concentration with increasing animal length (p < 0.05). These observations suggest the accumulation of PFCs in belugas is influenced by year, location, sex, and length.


Subject(s)
Beluga Whale/metabolism , Environmental Monitoring , Fluorocarbons/metabolism , Alaska , Alkanesulfonic Acids/metabolism , Animals , Arctic Regions , Female , Fetus/metabolism , Linear Models , Liver/metabolism , Time Factors
19.
Environ Sci Technol ; 44(13): 5202-9, 2010 Jul 01.
Article in English | MEDLINE | ID: mdl-20521819

ABSTRACT

Perfluorinated compounds (PFCs) are globally distributed persistent environmental contaminants. This study provides temporal trends as well as large-scale spatial trends of PFC concentrations in threatened juvenile loggerhead sea turtles near or from Florida Bay (FL Bay), Cape Canaveral (FL), Charleston (SC), Core Sound (NC), and Chesapeake Bay (MD). PFCs were extracted from 163 plasma and serum samples using solid-phase extraction and quantified with LC-MS/MS. Concentrations of six compounds significantly varied by site, with MD or FL Bay turtles having the highest concentrations. Perfluorooctane sulfonate (PFOS) was the predominant PFC at all sites (range: 0.31 ng/g to 39.0 ng/g). FL Bay turtles, compared to other sites, accumulated a unique PFC pattern with a higher proportion of perfluorocarboxylates compared to PFOS. Furthermore, this study was the first to statistically correlate wildlife PFC concentrations with human population, used as a proxy for urbanization and sources of PFCs to the environment. Positive relationships were found in which human population accounted for 75 and 81% of the variance in turtle PFOS and perfluoroundecanoate (PFUnA) concentrations (p = 0.06 and 0.04), respectively. PFOS and perfluorononanoate (PFNA) significantly decreased from 2000-2008 in SC turtles annually by 20 and 11%, respectively (p

Subject(s)
Fluorine Compounds/analysis , Turtles/metabolism , Animals , Calibration , Endangered Species , Environmental Monitoring/methods , Florida , Geography , Humans , Maryland , North Carolina , Regression Analysis , South Carolina , Time Factors , United States
20.
Anal Bioanal Chem ; 397(2): 439-51, 2010 May.
Article in English | MEDLINE | ID: mdl-19862506

ABSTRACT

Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.


Subject(s)
Fluorocarbons/analysis , Fluorocarbons/urine , Milk/chemistry , Animals , Environmental Monitoring/methods , Environmental Pollutants/analysis , Environmental Pollutants/standards , Environmental Pollutants/urine , Fluorocarbons/standards , Humans , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL
...