Braz J Otorhinolaryngol ; 90(4): 101423, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38657449

ABSTRACT

OBJECTIVES: To determine the benefits of cochlear implantation in hearing loss children with multiple disabilities (MD) in terms of auditory outcomes, speech performance, and their quality of life. METHODS: This was a cross sectional study from January 2019 to December 2020 in which thirty-one children with hearing loss and multiple disabilities were evaluated. Their improvement in auditory and speech performances were assessed using Categories of Auditory Performance version II (CAP-II) and the Speech Intelligibility Rating (SIR) scales. The assessment was done at 6-month intervals, with the baseline evaluation done at least six months after activation of the implant. Parents were asked to fill the Parents Evaluation of Aural/Oral Performance of Children (PEACH) diary and Perceived Benefit Questionnaire (PBQ) to evaluate the child's quality of life. RESULTS: All 31 children have Global Developmental Delay (GDD), with 11 having an additional disability. Both mean CAP-II and SIR scores showed significant improvement with increased hearing age (p < 0.05) after 6-month intervals. In addition, 20 out of 31 children (64.5%) have achieved verbal communication after implantation. The mean PEACH score in quiet was significantly better than in noise (p = 0.007) and improved with the increased of hearing age. The majority of parents (96%‒100%) perceived a cochlear implant as beneficial to their child in terms of auditory response, awareness, interaction, communication, and speech development. CONCLUSIONS: Cochlear implantation had shown benefits in children with multiple disabilities. Outcome measures should not only focus on auditory and speech performances but the improvement in quality of life. Hence, individualized each case with realistic expectation from families must be emphasized in this group of children. LEVEL OF EVIDENCE: Level 3.

2.
Otol Neurotol ; 45(4): e315-e321, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38478410

ABSTRACT

INTRODUCTION: Preservation of residual hearing after cochlear implantation allows for electroacoustic stimulation, which leads to better music appreciation, noise localization, and speech comprehension in noisy environments. Real-time intraoperative electrocochleography (rt-ECochG) monitoring has shown promise in improving residual hearing rates. Four-point impedance (4PI) is being explored as a potential biomarker in cochlear implantation that has been associated with fibrotic tissue response, hearing loss, and dizziness. In this study, we explore whether monitoring both rt-ECochG intraoperatively and postoperative 4PI improves predictions of the preservation of residual hearing. METHODS: This was a prospective cohort study. Adults with residual acoustic hearing underwent cochlear implantation with intraoperative intracochlear electrocochleography (ECochG) monitoring. The surgeon responded to a drop in ECochG signal amplitude of greater than 30% by a standardized manipulation of the electrode with the aim of restoring the ECochG. At the end of the procedure, the ECochG signal was categorized as being maintained or having dropped more than 30%. 4PI was measured on 1 day, 1 week, and 1 and 3 months after cochlear implantation. Residual hearing was measured by routine pure-tone audiogram at 3 months postoperatively. The ECochG category and 4PI impedance values were entered as factors in a multiple linear regression predicting the protection of residual hearing. RESULTS: Twenty-six patients were recruited. Rt-ECochG significantly predicted residual hearing at 3 months (t test; mean difference, 37.7%; p = 0.002). Inclusion of both 1-day or 3-month 4PI in a multiple linear regression with rt-ECochG markedly improved upon correlations with residual hearing compared with the rt-ECochG-only model (rt-ECochG and 1-d 4PI model, R2 = 0.67; rt-ECochG and 3-mo 4PI model, R2 = 0.72; rt-ECochG-only model, R2 = 0.33). CONCLUSIONS: Both rt-ECochG and 4PI predict preservation of residual hearing after cochlear implantation. These findings suggest that the biological response of the cochlea to implantation, as reflected in 4PI, is an important determinant of residual hearing, independent of the acute effects on hearing during implant surgery seen with rt-ECochG. We speculate that 4PI relates to inflammation 1 day after implantation and fibrosis at 3 months.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Humans , Cochlear Implantation/methods , Prospective Studies , Electric Impedance , Cochlea/surgery , Hearing , Audiometry, Evoked Response/methods , Biomarkers
4.
Otol Neurotol ; 45(3): 238-244, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38238914

ABSTRACT

BACKGROUND: The shape and position of cochlear implant electrodes could potentially influence speech perception, as this determines the proximity of implant electrodes to the spiral ganglion. However, the literature to date reveals no consistent association between speech perception and either the proximity of electrode to the medial cochlear wall or the depth of insertion. These relationships were explored in a group of implant recipients receiving the same precurved electrode. METHODS: This was a retrospective study of adults who underwent cochlear implantation with Cochlear Ltd.'s Slim Perimodiolar electrode at the Royal Victorian Eye and Ear Hospital between 2015 and 2018 (n = 52). Postoperative images were obtained using cone beam computed tomography (CBCT) and analyzed by multi-planar reconstruction to identify the position of the electrode contacts within the cochlea, including estimates of the proximity of the electrodes to the medial cochlear wall or modiolus and the angular depth of insertion. Consonant-vowel-consonant (CVC) monosyllabic phonemes were determined preoperatively, and at 3 and 12 months postoperatively. Electrically evoked compound action potential (ECAP) thresholds and impedance were measured from the implant array immediately after implantation. The relationships between electrode position and speech perception, electrode impedance, and ECAP threshold were an analyzed by Pearson correlation. RESULTS: Age had a negative impact on speech perception at 3 months but not 12 months. None of the electrode-wide measures of proximity between electrode contacts and the modiolus, nor measures of proximity to the medial cochlear wall, nor the angular depth of insertion of the most apical electrode correlated with speech perception. However, there was a moderate correlation between speech perception and the position of the most basal electrode contacts; poorer speech perception was associated with a greater distance to the modiolus. ECAP thresholds were inversely related to the distance between electrode contacts and the modiolus, but there was no clear association between this distance and impedance. CONCLUSIONS: Speech perception was significantly affected by the proximity of the most basal electrodes to the modiolus, suggesting that positioning of these electrodes may be important for optimizing speech perception. ECAP thresholds might provide an indication of this proximity, allowing for its optimization during surgery.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Humans , Infant , Cochlear Implantation/methods , Retrospective Studies , Cochlea/diagnostic imaging , Cochlea/surgery , Evoked Potentials
5.
Laryngoscope ; 134(3): 1410-1416, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37694764

ABSTRACT

INTRODUCTION: Intraoperative trauma leading to bleeding during cochlear implantation negatively impacts residual hearing of cochlear implant recipients. There are no clinical protocols for the removal of blood during implantation, to reduce the consequential effects such as inflammation and fibrosis which adversely affect cochlear health and residual hearing. This preclinical study investigated the implementation of an intra-cochlear flushing protocol for the removal of blood. METHODS: Three groups of guinea pigs were studied for 28 days after cochlear implantation; cochlear implant-only (control group); cochlear implant with blood injected into the cochlea (blood group); and cochlear implant, blood injection, and flushing of the blood from the cochlea intraoperatively (flush group). Auditory brainstem responses (ABRs) in addition to tissue response volumes were analyzed and compared between groups. RESULTS: After implantation, the blood group exhibited the highest ABR thresholds when compared to the control and flush group, particularly in the high frequencies. On the final day, the control and blood group had similar ABR thresholds across all frequencies tested, whereas the flush group had the lowest thresholds, significantly lower at 24 kHz than the blood and control group. Analysis of the tissue response showed the flush group had significantly lower tissue responses in the basal half of the array when compared with the blood and control group. CONCLUSIONS: Flushing intra-cochlear blood during surgery resulted in better auditory function and reduced subsequent fibrosis in the basal region of the cochlea. This finding prompts the implementation of a flushing protocol in clinical cochlear implantation. LEVEL OF EVIDENCE: N/A Laryngoscope, 134:1410-1416, 2024.


Subject(s)
Blood Group Antigens , Cochlear Implantation , Cochlear Implants , Animals , Guinea Pigs , Cochlear Implantation/methods , Cochlea/pathology , Fibrosis , Evoked Potentials, Auditory, Brain Stem , Auditory Threshold
6.
Otol Neurotol ; 45(1): 36-45, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38085760

ABSTRACT

HYPOTHESIS: Gross electrode movements detected with intraoperative, real-time X-ray fluoroscopy will correlate with fluctuations in cochlear output, as measured with intraoperative electrocochleography (ECochG). BACKGROUND: Indications for cochlear implantation (CI) are expanding to include patients with residual hearing; however, implant recipients often lose residual hearing after CI. The objective of this study was to identify probable traumatic events during implantation by combining electrophysiological monitoring of cochlear function with simultaneous X-ray monitoring. The surgical timing of these apparently traumatic events was then investigated. METHODS: For 19 adult patients (21 surgeries, 2 bilateral), the ECochG responses were measured during implantation of a cochlear nucleus slim modiolar electrode (CI532/CI632, Cochlear Ltd Australia Nucleus slim modiolar). Simultaneous fluoroscopy was performed, as well as a postoperative cone-beam computed tomography (CT) scan. For all patients, pre- and postoperative audiograms were recorded up to 1 year after surgery to record the loss of residual hearing. RESULTS: Electrode insertions for 21 surgeries were successfully monitored. A drop in ECochG response was significantly correlated with reduced hearing preservation compared with patients with preserved responses throughout. Drops in the ECochG response were measured to occur during insertion, because of movement of the array after insertion was complete, including while sealing of the electrode array at the round window or coiling of the array lead within the mastoid cavity. In some patients, a reduction in cochlear output, resulting in poor ECochG response, was inferred to occur before the beginning of implantation. CONCLUSION: The combination of perioperative ECochG measurements, microscope video, fluoroscopy, and postoperative CT scan may inform on what causes the loss of residual hearing after implantation. These findings will be used to improve the surgical procedure in future.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Humans , Audiometry, Evoked Response/methods , Cochlea/diagnostic imaging , Cochlea/surgery , Cochlea/injuries , Cochlear Implantation/methods , Fluoroscopy
7.
Article in English | MEDLINE | ID: mdl-38083677

ABSTRACT

Biosensing technologies are emerging as an important consideration when designing implantable medical devices. For cochlear implants, biosensors may help preserve the natural hearing a patient has prior to implantation by detecting blood in the cochlea during insertion. If blood enters the cochlea, it creates a hostile environment leading to further hearing loss and reduced device function. Here we present four-point impedance, measured directly from a commercial cochlear implant, as a biosensor for real-time detection of blood in the cochlea. The four-point impedance of different concentrations of whole blood in saline were measured using the impedance-measuring capabilities of a cochlear implant with a square-wave stimulation. Impedance derived from a cochlear implant succeeded in differentiating concentrations of blood in saline with results from a sensitivity analysis showing the lowest concentration the system could detect was between 12 % to 21 % of whole blood. In a subsequent in-vitro study, continuous four-point impedance was measured from a cochlear implant while it was inserted into a 3D printed cochlear model, followed by an injection of blood to emulate surgical events. These results demonstrated four-point impedance from a cochlear implant can instantaneously detect the addition of blood within the cochlea and localize it along the electrode array. The adaptation of a biosensing tool using a cochlear implant provides more information that can be relayed to the surgeon intraoperatively to potentially enhance hearing outcomes with the implant.Clinical Relevance - Using the cochlear implant itself to detect intra-cochlear bleeding may open therapeutic avenues to prevent further hearing loss.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Hearing Loss , Humans , Cochlear Implantation/methods , Electric Impedance , Cochlea/surgery , Hearing Loss/surgery , Deafness/surgery
8.
Appl Microbiol Biotechnol ; 107(23): 7375-7390, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37733052

ABSTRACT

Production of microalgae is a potential technology for capturing and recycling carbon dioxide from cement kiln emissions. In this study, a process of selecting a suitable strain that would effectively utilize carbon dioxide and generate biomass was investigated. A down-selection screening method was applied to 28 strains isolated from the area surrounding a commercial cement plant. In laboratory-scale (1 L) continuous-mode chemostats, observed productivity was > 0.9 g L-1 d-1 for most strains studied. Chlorella sorokiniana (strain SMC-14M) appeared to be the most tolerant to cement kiln gas emissions in situ, delivered under control of a pH-stat system, and was down-selected to further investigate growth and biomass production at large-scale (1000 L) cultivation. Results demonstrated little variability in lipid, crude protein, and carbohydrate composition throughout growth between kiln-gas grown algal biomass and biomass produced with laboratory grade CO2. The growth rate at which the maximum quantity of CO2 from the emissions is recycled also produced the maximum amount of the targeted biomass components to increase commercial value of the biomass. An accumulation of some heavy metals throughout its growth demonstrates the necessity to monitor the biomass cultivated with industrial flue gases and to carefully consider the potential applications for this biomass; despite its other attractive nutritional properties. KEY POINTS: • Studied high biomass producing algal strains grown on CO2 from cement flue gas. • Chlorella sorokiniana SMC-14M grew well at large scale, in situ on cement flue gas. • Demonstrated the resulting commercial potential of the cultured algal biomass.


Subject(s)
Chlorella , Microalgae , Carbon Dioxide/metabolism , Microalgae/metabolism , Chlorella/metabolism , Biomass , Gases/metabolism
9.
Acta Otolaryngol ; 143(8): 647-654, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37603289

ABSTRACT

BACKGROUND: Systemically administered steroids are widely utilised for hearing preservation therapies. More recently, steroids have been administered to achieve hearing protection after cochlear implant surgery. Currently there is a lack of understanding as to which administration route offers most therapeutic efficacy, local or systemic administration. Paramount to this are observations in animal studies that systemic administration following implantation offers hearing protection and reduced cochlear fibrosis, despite observations that perilymphatic levels are up to 10-fold higher after local administration in non-implanted cochleae. AIMS/OBJECTIVES: This paper explores the impact that cochlear implantation and associated acute inflammation has on steroid distribution and uptake following systemic administration of dexamethasone. MATERIAL AND METHODS: Eight guinea pigs received systemic dexamethasone 60 min prior to cochlear implantation. Implanted and contralateral non-implanted cochlea were harvested for tissue immunohistochemistry and detection of dexamethasone. RESULTS: Cochleostomy with scala tympani implantation resulted in a significant increase in cochlear dexamethasone signal. This was most notable at the organ of Corti, stria vascularis, and blood product in the scala tympani. CONCLUSIONS AND SIGNIFICANCE: This study demonstrates that the inner ear distribution of systemically administered steroids is enhanced following surgery for cochlear implantation and provides rationale for systemic perioperative steroids in hearing preservation surgery.


Subject(s)
Cochlear Implantation , Cochlear Implants , Animals , Guinea Pigs , Cochlea/surgery , Steroids , Dexamethasone
10.
Otol Neurotol ; 44(7): 688-695, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37400267

ABSTRACT

INTRODUCTION: Postimplantation dizziness is common, affecting approximately 50% of patients. Theories for dizziness include utricular inflammation, endolymphatic hydrops, and loss of perilymph. Four-point impedance (4PI) is a novel impedance measurement in cochlear implantation that shows potential to predict hearing loss, inflammation, and fibrotic tissue response. Here, we associate 4PI with dizziness after implantation and explore the link with utricular function. METHODS: Subjective visual vertical (SVV) as a measure of utricular function was recorded preoperatively as a baseline. 4PI was measured immediately postinsertion. Ongoing follow-up was performed at 1 day, 1 week, and 1 month, postoperatively. At each follow-up, 4PI, SVV, and the patients' subjective experience of dizziness were assessed. DISCUSSION: Thirty-eight adults were recruited. One-day 4PI was significantly higher in patients dizzy within the next week (254 Ω vs 171 Ω, p = 0.015). The optimum threshold on receiver operating characteristic curve was 190 Ω, above which patients had 10 times greater odds of developing dizziness (Fisher exact test, OR = 9.95, p = 0.0092). This suggests that 4PI varies with changes in the intracochlear environment resulting in dizziness, such as inflammation or hydrops. SVV significantly deviated away from the operated ear at 1 day (fixed effect estimate = 2.6°, p ≤ 0.0001) and 1 week (fixed effect estimate 2.7°, p ≤ 0.001). CONCLUSION: One-day 4PI is a potentially useful marker for detecting postoperative dizziness after cochlear implantation. Of the current theories for postoperative dizziness, inflammation might explain the findings seen here, as would changes in hydrostatic pressure. Future research should focus on detecting and exploring these labyrinthine changes in further detail.


Subject(s)
Cochlear Implantation , Endolymphatic Hydrops , Adult , Humans , Dizziness/etiology , Dizziness/diagnosis , Cochlear Implantation/adverse effects , Electric Impedance , Vertigo/diagnosis , Endolymphatic Hydrops/diagnosis
11.
Ear Hear ; 44(5): 1088-1106, 2023.
Article in English | MEDLINE | ID: mdl-36935398

ABSTRACT

OBJECTIVES: The underlying state of cochlear and neural tissue function is known to affect postoperative speech perception following cochlear implantation. The ability to assess these tissues in patients can be performed using intracochlear electrocochleography (IC ECochG). One component of ECochG is the summating potential (SP) that appears to be generated by multiple cochlear tissues. Its qualities may be able to detect the presence of functional inner hair cells, but evidence for this is limited in human cochleae. This study aimed to examine the IC SP characteristics in cochlear implantation recipients, its relationship to preoperative speech perception and audiometric thresholds, and to other IC ECochG components. DESIGN: This is a retrospective analysis of 113 patients' IC ECochG recordings across the array in response to a 500 Hz tone burst stimulus. Responses to condensation and rarefaction stimuli were then subtracted from one another to emphasize the cochlear microphonic and added to one another to emphasize the SP, auditory nerve neurophonic, and compound action potential. Patients were grouped based on their maximum SP deflection being large and positive (+SP), large and negative (-SP), or minimal (0 SP) to further investigate these relationships. RESULTS: Patients in the +SP group had better preoperative speech perception (mean consonant-vowel-consonant phoneme score 46%) compared to the -SP and 0 SP groups (consonant-vowel-consonant phoneme scores 34% and 36%, respectively, difference to +SP: p < 0.05). Audiometric thresholds were lowest for +SP (mean pure-tone average 50 dB HL), then -SP (65 dB HL), and highest for 0 SP patients (70 dB HL), but there was not a statistical significance between +SP and -SP groups ( p > 0.1). There were also distinct differences between SP groups in the qualities of their other ECochG components. These included the +SP patients having larger cochlear microphonic maximum amplitude, more apical SP peak electrode locations, and a more spatially specific SP magnitude growth pattern across the array. CONCLUSIONS: Patients with large positive SP deflection in IC ECochG have preoperatively better speech perception and lower audiometric thresholds than those without. Patterns in other ECochG components suggest its positive deflection may be an indicator of cochlear function.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Retrospective Studies , Cochlea , Cochlear Nerve , Audiometry, Evoked Response
12.
J Int Adv Otol ; 19(1): 16-21, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36718031

ABSTRACT

BACKGROUND: Surgical rehearsal - patient-specific preoperative surgical practice - can be provided by virtual reality simulation. This study investigated the effect of surgical rehearsal on cortical mastoidectomy performance and procedure duration. METHODS: University students (n=40) were randomized evenly into a rehearsal and control group. After watching a video tutorial on cortical mastoidectomy, participants completed the procedure on a virtual reality simulator as a pre-test. Participants completed a further 8 cortical mastoidectomies on the virtual reality simulator as training before drilling two 3-dimensional (3D) printed temporal bones. The rehearsal group received 3D printed bones they had previously operated on in virtual reality, while the control group received 2 new bones. Cortical mastoidectomy was assessed by 3 blinded graders using the Melbourne Mastoidectomy Scale. RESULTS: There was high interrater reliability between the 3 graders (intraclass correlation coefficient, r=0.8533, P < .0001). There was no difference in the mean surgical performance on the two 3D printed bones between the control and rehearsal groups (P=.2791). There was no significant difference in the mean procedure duration between the control and rehearsal groups for both 3D printed bones (P=.8709). However, there was a significant decrease in procedure duration between the first and second 3D printed bones (P < .0001). CONCLUSION: In this study, patient-specific virtual reality rehearsal provided no additional advantage to cortical mastoidectomy performance by novice operators compared to generic practice on a virtual reality simulator. Further, virtual reality training did not improve cortical mastoidectomy performance on 3D printed bones, highlighting the impact of anatomical diversity and changing operating modalities on the acquisition of new surgical skills.


Subject(s)
Otolaryngology , Virtual Reality , Humans , Reproducibility of Results , Temporal Bone/surgery , Curriculum
13.
Eur Arch Otorhinolaryngol ; 280(3): 947-962, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36301356

ABSTRACT

The objective of this systematic review is to compare the diagnostic value of endolymphatic hydrops (EH) magnetic resonance imaging (MRI) with audiovestibular function tests, including electro cochleography (ECochG), cervical vestibular evoked myogenic potential (cVEMP) and caloric tests for the diagnosis of definite Meniere's disease (DMD). An electronic search was performed in the PubMed, Embase and Cochrane databases in August 2022. Original studies which reported the efficacy of gadolinium MRI for diagnosis of DMD were compared with ECochG, cVEMP and caloric tests from 2007 to 2022 published in English. Two reviewers extracted the methodology and results of MRI and functional tests, assessing them independently. A modified version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used for the assessment of the quality and the risk of bias of each study. The proportion of DMD cases diagnosed by MRI hydrops vs corresponding functional tests were calculated and the relationship between MRI and functional tests were evaluated using the Cohen's Kappa test. Concerning the MRI, the proportion diagnostic of DMD was 0.67 by cochlear EH and 0.80-0.82 by vestibular EH. Regarding the functional test, the propotiojn diagnostic of DMD was 0.48 by ECochG, 0.76 by cVEMP and 0.65 by caloric test. The findings of this systematic review were that the vestibular EH on imaging most effectively assisted in diagnosing DMD. Among the functional tests, cVEMP was the second most effective test. The agreement between imaging and cVEMP was moderate (0.44), indicating a gap between the patients identified by the imaging and functional tests based on the relatively small number of patients.


Subject(s)
Endolymphatic Hydrops , Vestibular Evoked Myogenic Potentials , Humans , Caloric Tests , Vestibular Evoked Myogenic Potentials/physiology , Audiometry, Evoked Response , Endolymphatic Hydrops/diagnostic imaging , Magnetic Resonance Imaging/methods , Edema
14.
Biosens Bioelectron ; 222: 114866, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36463651

ABSTRACT

The level of hearing restoration in patients with severe to profound sensorineural hearing loss by means of cochlear implants (CIs) has drastically risen since the introduction of these neuroprosthetics. The proposed CI integrated with polymer optical fiber Bragg gratings (POFBGs) enables real-time evaluation of insertion forces and trajectory determination during implantation irrespective of the speed of insertion, as well as provides high signal quality, low stiffness levels, minimum induced stress even under forces of high magnitudes and exhibits significant reduction of the risk of fiber breakage inside the constricted cochlear geometry. As such, the proposed device opens new avenues towards atraumatic cochlear implantations and provides a direct route for the next generation of CIs with intraoperative insertion force assessment and path planning capacity crucial for surgical navigation. Hence, adaptation of this technology to clinical reality holds promising prospects for the hearing impaired.


Subject(s)
Biosensing Techniques , Cochlear Implantation , Cochlear Implants , Humans , Hearing , Cochlea/surgery
15.
Ear Hear ; 44(4): 710-720, 2023.
Article in English | MEDLINE | ID: mdl-36550618

ABSTRACT

OBJECTIVES: Different patterns of electrocochleographic responses along the electrode array after insertion of the cochlear implant electrode array have been described. However, the implications of these patterns remain unclear. Therefore, the aim of the study was to correlate different peri- and postoperative electrocochleographic patterns with four-point impedance measurements and preservation of residual hearing. DESIGN: Thirty-nine subjects with residual low-frequency hearing which were implanted with a slim-straight electrode array could prospectively be included. Intracochlear electrocochleographic recordings and four-point impedance measurements along the 22 electrodes of the array (EL, most apical EL22) were conducted immediately after complete insertion and 3 months after surgery. Hearing preservation was assessed after 3 months. RESULTS: In perioperative electrocochleographic recordings, 22 subjects (56%) showed the largest amplitude around the tip of the electrode array (apical-peak, AP, EL20 or EL22), whereas 17 subjects (44%) exhibited a maximum amplitude in more basal regions (mid-peak, MP, EL18 or lower). At 3 months, in six subjects with an AP pattern perioperatively, the location of the largest electrocochleographic response had shifted basally (apical-to-mid-peak, AP-MP). Latency was analyzed along the electrode array when this could be discerned. This was the case in 68 peri- and postoperative recordings (87% of all recordings, n = 78). The latency increased with increasing insertion depth in AP recordings (n = 38, median of EL with maximum latency shift = EL21). In MP recordings (n = 30), the maximum latency shift was detectable more basally (median EL12, p < 0.001). Four-point impedance measurements were available at both time points in 90% (n = 35) of all subjects. At the 3-month time point, recordings revealed lower impedances in the AP group (n = 15, mean = 222 Ω, SD = 63) than in the MP (n = 14, mean = 295 Ω, SD= 7 6) and AP-MP groups (n = 6, mean = 234 Ω, SD = 129; AP versus MP p = 0.026, AP versus AP-MP p = 0.023, MP versus AP-MP p > 0.999). The amplitudes of perioperative AP recordings showed a correlation with preoperative hearing thresholds ( r2 =0.351, p = 0.004). No such correlation was detectable in MP recordings ( r2 = 0.033, p = 0.484). Audiograms were available at both time points in 97% (n = 38) of all subjects. The mean postoperative hearing loss in the AP group was 13 dB (n = 16, SD = 9). A significantly larger hearing loss was detectable in the MP and AP-MP groups with 28 (n = 17, SD = 10) and 35 dB (n = 6, SD = 13), respectively (AP versus MP p = 0.002, AP versus AP-MP p = 0.002, MP versus AP-MP p = 0.926). CONCLUSION: MP and AP-MP response patterns of the electrocochleographic responses along the electrode array after cochlear implantation are correlated with higher four-point impedances and poorer postoperative hearing compared to AP response patterns. The higher impedances suggest that MP and AP-MP patterns are associated with increased intracochlear fibrosis.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Hearing Loss , Humans , Electric Impedance , Hearing Loss/surgery , Cochlea/surgery , Deafness/surgery
16.
Otol Neurotol ; 43(10): e1107-e1114, 2022 12 01.
Article in English | MEDLINE | ID: mdl-36351225

ABSTRACT

OBJECTIVE: Monitor four-point impedance in cochlear implant recipients over time and determine if implant type, surgical approach, and electrode positioning affected impedance measurements. STUDY DESIGN: Prospective observational. SETTING: Hospital. PATIENTS: Adult cochlear implant recipients implanted with a perimodiolar or lateral wall cochlear implant. MAIN OUTCOME MEASURES: Mean values for four-point impedances were calculated for all electrode contacts at perioperative and 3 months after surgery. Linear mixed models were applied to the impedance data to compare between implant types and time points. The angular insertion depth and electrode position relative to the medial and lateral wall, commonly termed the Intracochlear Position Index (ICPI), were collected and compared with impedance measurements. RESULTS: Perioperatively, the four-point impedance was similar between implant types, with perimodiolar implants having marginally higher impedance values in the basal region. At 3 months after surgery, impedances significantly increased in the basal half of the electrode array for both implants, with higher impedance values for CI532 implants. There were no significant differences in insertion angle depth between implant types. The ICPI values for the seven most basal electrodes were similar for both implants; however, CI532 arrays were significantly more medially placed along the remaining apical portion of the array, which is expected. ICPI values did not correlate with impedance measurements for either implant. CONCLUSIONS: Four-point impedance increases at 3 months after surgery may reflect fibrous tissue formation after cochlear implantation. The higher impedance values in perimodiolar implants may reflect a more extensive fibrosis formation as a result of surgical approaches used, requiring drilling of the cochlea bone.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Humans , Electric Impedance , Cochlea/surgery , Electrodes, Implanted
17.
Otol Neurotol ; 43(7): e730-e737, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35861642

ABSTRACT

OBJECTIVE: Monitoring four-point impedance changes after cochlear implantation with comparison to conventional impedance measurements. Four-point impedance provides information regarding the bulk biological environment surrounding the electrode array, which is not discernible with conventional impedances. STUDY DESIGN: Prospective observational. SETTING: Hospital. PATIENTS: Adult cochlear implant recipients with no measurable hearing before implantation and implanted with a perimodiolar cochlear implant. MAIN OUTCOME MEASURES: Mean values for four-point and common ground impedances were calculated for all electrode contacts at intra-operative, 1 day, 1 week, 4 to 6 weeks, and 3 months post implantation. Linear mixed models were applied to the impedance data to compare between impedances and time points. Furthermore, patients were divided into groups dependent on the normalized change in four-point impedance from intra-operative to 1 day post-operative. The normalized change was then calculated for all other time points and compared across the two groups. RESULTS: Significant increases in four-point impedance occurred 1 day and 3 months after surgery, particularly in the basal half of the array. Four-point impedance at 1 day was highly predictive of four-point impedance at 3 months. Four-point impedance at the other time points showed marginal or no increases from intra-operative. Patients with an average increase higher than 10% in four-point impedance from intra-operative to 1 day, had significantly higher values at 3 months ( p = 0.012). These patterns were not observed in common ground impedance. CONCLUSION: This is the first study to report increases in four-point impedance within 24 hours of cochlear implantation. The increases at 1 day and 3 months align with the natural timeline of an acute and chronic inflammatory responses.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Electric Impedance , Hearing Tests , Humans , Postoperative Period
18.
PLoS One ; 17(7): e0269187, 2022.
Article in English | MEDLINE | ID: mdl-35834542

ABSTRACT

Cochlear implants (CIs) provide an opportunity for the hearing impaired to perceive sound through electrical stimulation of the hearing (cochlear) nerve. However, there is a high risk of losing a patient's natural hearing during CI surgery, which has been shown to reduce speech perception in noisy environments as well as music appreciation. This is a major barrier to the adoption of CIs by the hearing impaired. Electrocochleography (ECochG) has been used to detect intra-operative trauma that may lead to loss of natural hearing. There is early evidence that ECochG can enable early intervention to save natural hearing of the patient. However, detection of trauma by observing changes in the ECochG response is typically carried out by a human expert. Here, we discuss a method of automating the analysis of cochlear responses during CI surgery. We establish, using historical patient data, that the proposed method is highly accurate (∼94% and ∼95% for sensitivity and specificity respectively) when compared to a human expert. The automation of real-time cochlear response analysis is expected to improve the scalability of ECochG and improve patient safety.


Subject(s)
Cochlear Implantation , Cochlear Implants , Hearing Loss , Audiometry, Evoked Response/methods , Cochlea/surgery , Cochlear Implantation/methods , Hearing , Hearing Loss/diagnosis , Hearing Loss/surgery , Humans
19.
Otol Neurotol ; 43(6): 685-693, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35761462

ABSTRACT

BACKGROUND: Endolymphatic hydrops (EH) has been observed in both animal and human cochleae following cochlear implant (CI) surgery. We tested whether EH could be eliminated by administration of mineralocorticoid steroid antagonist spironolactone and explored the electrophysiological consequences of this. METHODS: Sixty-four adult guinea pigs underwent cochlear implantation with a dummy electrode. Animals then survived either 2, 7, or 28 days. Auditory function was monitored by recording electrocochleography from the round window membrane preimplantation, and on the last day of the experiment. Spironolactone or control solution was added to animals' feed for 7 days (if they survived that long) beginning immediately prior to surgery. The presence of EH was determined using thin-sheet laser imaging microscopy. RESULTS: Treatment with spironolactone resulted in significant reduction in EH in the second cochlear turn 7 days postimplantation. In all animals, the compound action potential (CAP) threshold was elevated 2 days postimplantation, but for most frequencies had recovered substantially by 28 days. There was no treatment effect on CAP thresholds. SP/AP ratios were elevated at day 2. The amplitude growth of the CAP did not differ between test and control groups at any time after implantation. CONCLUSIONS: EH can be suppressed by antagonism of mineralocorticoid receptors in the week after cochlear implantation. Reduction in EH did not lead to any change in hearing, and there was no indication of synaptopathy signalled by reduced CAP amplitude at high sound intensities. We found no electrophysiological evidence that EH early after implantation impacts negatively upon preservation of residual hearing.


Subject(s)
Cochlear Implantation , Cochlear Implants , Endolymphatic Hydrops , Animals , Audiometry, Evoked Response , Endolymphatic Hydrops/drug therapy , Endolymphatic Hydrops/etiology , Guinea Pigs , Humans , Spironolactone/pharmacology , Spironolactone/therapeutic use
20.
Eur Arch Otorhinolaryngol ; 279(10): 4917-4923, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35355112

ABSTRACT

SETTING: The Eustachian tube plays a vital role in middle ear physiology. There has been evidence that Eustachian tube (ET) and angle are correlated with middle ear function. The measurements of these Eustachian tube features are now made possible with computed tomography and multiplanar reconstruction techniques. However, there has not been a standardised protocol devised to these measurements in limited window cone-beam CT scans of temporal bones. OBJECTIVE: The primary object of the present study is to establish and validate a new landmark in closer proximity to the middle ear that is consistently captured, thereby allowing ET angle and length to be measured from the majority of cone-beam CT scans. Secondarily, the ET anatomies of patients with middle ear dysfunction manifesting as acquired cholesteatoma are analysed with this new method of measurement. METHODS: This study undertook a step-by-step method to first validate the methods of ET measurement with Reid's standard plane, then identifying an alternative landmark, thus a new plane visible on limited window cone-beam CT scans of temporal bones and lastly, validating the application of this new plane in the measurements of ET angle and length. This new method of measurement was coined the Ku-Copson plane and was applied to 30 cochlear implant patients and 30 patients with acquired cholesteatomas. Their ET anatomies were analysed and compared. RESULTS: It was found that the new Ku-Copson mandibular fossa plane was a reliable and accurate plane for the measurement of ET angle and length. Furthermore, it was found that patients with acquired cholesteatomas have statistically significant smaller ET angles and shorter ET lengths when compared with patients with cochlear implants, of normal middle ear function. CONCLUSION: The newly proposed method utilising the right mandibular fossa as an anatomical landmark for ET angles and lengths measurement appears to be viable. The close proximity of this landmark to the middle ear means that it is highly likely to be captured in most cone-beam CT scans of the petrous temporal bones. This enables the retrospective examination ET angles and lengths to be conducted on CB CT scans. This study reports statistically significant difference in ET anatomy in patients with middle ear dysfunction.


Subject(s)
Cholesteatoma , Eustachian Tube , Ear, Middle/diagnostic imaging , Humans , Retrospective Studies , Temporal Bone/diagnostic imaging