Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Analyst ; 140(3): 706-9, 2015 Feb 07.
Article in English | MEDLINE | ID: mdl-25453038

ABSTRACT

A novel, solution immersed silicon (SIS)-based sensor has been developed which employs the non-reflecting condition (NRC) for a p-polarized wave. The SIS sensor's response is almost independent of change in the refractive index (RI) of a buffer solution (BS) which makes it capable of measuring low-concentration and/or low-molecular-weight compounds.


Subject(s)
Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Refractometry/methods , Silicon/chemistry , Solutions
2.
Diabetes Technol Ther ; 8(2): 174-90, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16734548

ABSTRACT

BACKGROUND: Critically ill patients are often hyperglycemic and insulin resistant, as well as highly dynamic. Tight glucose control has been shown to significantly reduce mortality in critical care. A physiological model of the glucose-insulin regulatory system is improved and used to develop an adaptive control protocol utilizing both nutritional and insulin inputs to control hyperglycemia. The approach is clinically verified in a critical care patient cohort. METHODS: A simple two-compartment model for glucose rate of appearance in plasma due to stepwise enteral glucose fluxes is developed and incorporated into a previously validated system model. A control protocol modulating intravenous insulin infusion and bolus, with an enteral feed rate, is developed, enabling tight and predictive glycemic regulation to preset targets. The control protocol is adaptive to patient time-variant effective insulin resistance. The model and protocol are verified in seven 10-h and one 24-h proof-of-concept clinical trials. Ethics approval was granted by the Canterbury Ethics Committee. RESULTS: Insulin requirements varied widely following acute changes in patient physiology. The algorithm developed successfully adapted to patient metabolic status and insulin sensitivity, achieving an average target acquisition error of 9.3% with 90.7% of all targets achieved within +/-20%. Prediction errors may not be distinguishable from sensor measurement errors. Large errors (>20%) are attributable to highly dynamic and unpredictable changes in patient condition. CONCLUSIONS: Tight, targeted stepwise regulation was exhibited in all trials. Overall, tight glycemic regulation is achieved in a broad critical care cohort with optimized insulin and nutrition delivery, effectively managing glycemia even with high effective insulin resistance.


Subject(s)
Blood Glucose , Critical Care/methods , Enteral Nutrition/standards , Hypoglycemic Agents/administration & dosage , Insulin/administration & dosage , Aged , Algorithms , Clinical Protocols , Critical Illness/therapy , Enteral Nutrition/adverse effects , Female , Humans , Hyperglycemia/drug therapy , Insulin Resistance , Male , Middle Aged , Models, Biological
3.
Med Eng Phys ; 28(7): 665-81, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16343972

ABSTRACT

Stress-induced hyperglycaemia is prevalent in intensive care, impairing the immune response. Nutritional support regimes with high glucose content further exacerbate the problem. Tight glucose control has been shown to reduce mortality by up to 43% if levels are kept below 6.1 mmol/L. This research develops a control algorithm with insulin and nutritional inputs for targeted glucose control in the critically ill. Ethics approval for this research was granted by the Canterbury Ethics Committee. Proof-of-concept clinical pilot trials were conducted on intubated, insulin-dependent Christchurch ICU patients (n=7) on constant nutritional support. A target 10-15% reduction in glucose level per hour for a desired glucose level of 4-6 mmol/L was set. 43% and 91% of glucose targets were achieved within +/-5 and +/-20%, respectively. The mean error was 8.9% (0.5 mmol/L), with an absolute range [0, 2.9] mmol/L. End glucose levels were 40% lower compared to initial values. All large target errors are attributable to sudden changes in patient physiology at low glucose values, rather than systemic deficiencies. Target errors are consistent with and explainable by published sensor error distributions. The results show that intensive model-based glucose management with nutrition control reduced absolute glucose levels progressively while reducing the severity of glycaemic fluctuation even with significant inter-patient variability and time-varying physiological condition. Trials spanning longer periods of time are in development to verify the short-term pilot studies performed and to test the adaptability of the controller. Clinically, these results indicate potential in clinical use to reduce ICU mortality as well as reduce risk of severe complications.


Subject(s)
Blood Glucose/metabolism , Hyperglycemia/diet therapy , Hyperglycemia/drug therapy , Insulin/administration & dosage , Models, Biological , Aged , Biomedical Engineering , Cohort Studies , Critical Care , Critical Illness , Enteral Nutrition , Female , Humans , Male , Middle Aged , Nutritional Support , Pilot Projects , Retrospective Studies
4.
Stud Health Technol Inform ; 52 Pt 1: 429-32, 1998.
Article in English | MEDLINE | ID: mdl-10384493

ABSTRACT

The Korea Medical Insurance Corporation has held the periodic Health Examination for the public servants and teachers from 1977 as a nationwide health preventive task. But the Health Examination result is not computerized rather than paperwork, so the use of the Health Examination is limited and the results of Health Examination can not be stored or interchangeable between hospitals or health examination centers in this system. So we planed the Standardization of the Nationwide Health Examination project and developed the Health Examination computer program in 1996. The object of standardized program is to contribute to cost-effective analysis of each item or other studies about the factors influences development of diseases. And now, an Exhibition work for the standardization is being held with the Health Examination computer program. At the ending of the Exhibition work, we will evaluation and revision the computerized program for standardization process.


Subject(s)
Medical Records Systems, Computerized/standards , Physical Examination/standards , Computer Systems , Employment , Humans , Korea , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL