Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Clin Transl Radiat Oncol ; 43: 100685, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37842073

ABSTRACT

Introduction: Distended rectums on pre-radiotherapy scans are historically associated with poorer outcomes in patients treated with two-dimensional IGRT. Subsequently, strict rectal tolerances and preparation regimes were implemented. Contemporary IGRT, daily online registration to the prostate, corrects interfraction motion but intrafraction motion remains. We re-examine the need for rectal management strategies when using contemporary IGRT by quantifying rectal volume and its effect on intrafraction motion. Materials and methods: Pre and during radiotherapy rectal volumes and intrafraction motion were retrospectively calculated for 20 patients treated in 5-fractions and 20 treated in 20-fractions. Small (rectal volume at planning-CT ≤ median), and large (volume > median) subgroups were formed, and rectal volume between timepoints and subgroups compared. Rectal volume and intrafraction motion correlation was examined using Spearman's rho. Intrafraction motion difference between small and large subgroups and between fractions with rectal volume < or ≥ 90 cm3 were assessed. Results: Median rectal volume was 74 cm3, 64 cm3 and 65 cm3 on diagnostic-MRI, planning-CT and treatment imaging respectively (ns). No significant correlation was found between patient's rectal volume at planning-CT and median intrafraction motion, nor treatment rectal volume and intrafraction motion for individual fractions. No significant difference in intrafraction motion between small and large subgroups presented and for fractions where rectal volume breached 90 cm3, motion during that fraction was not significantly greater. Conclusion: Larger rectal volumes before radiotherapy and during treatment did not cause greater intrafraction motion. Findings support the relaxation of strict rectal diameter tolerances and do not support the need for rectal preparation when delivering contemporary IGRT to the prostate.

2.
Clin Transl Radiat Oncol ; 40: 100604, 2023 May.
Article in English | MEDLINE | ID: mdl-36936470

ABSTRACT

Purpose: A scoping literature review was conducted to identify gastrointestinal (GI) factors most likely to influence prostate motion during radiotherapy. We proffer that patient specific measurement of these GI factors could predict motion uncertainty during radiotherapy, facilitating personalised care by optimising treatment technique e.g., daily adaption or via bespoke patient pre-habilitation and preparation. Methods: The scoping review was undertaken as per JBI guidelines. Searches were conducted across four databases: Ovid Medline®, EMBASE, CINAHL and EBSCO discovery. Articles written in English from 2010-present were included. Those pertaining to paediatrics, biological women exclusively, infectious and post-treatment GI morbidity and diet were excluded.Common GI factors impacting men were identified and related symptoms, incidence and measurement tools examined. Prevalence among persons with prostate cancer was explored and suitable assessment tools discussed. Results: A preliminary search identified four prominent GI-factors: mental health, co-morbidity and medication, physical activity, and pelvic floor disorder. The scoping search found 3644 articles; 1646 were removed as duplicates. A further 1249 were excluded after title and abstract screening, 162 remained subsequent to full text review: 42 mental health, 53 co-morbidity and medication, 39 physical activity and 28 pelvic floor disorder.Six GI factors prevalent in the prostate cancer population and estimated most likely to influence prostate motion were identified: depression, anxiety, diabetes, obesity, low physical activity, and pelvic floor disorder. Reliable, quick, and easy to use tools are available to quantify these factors. Conclusion: A comprehensive GI factor assessment package suitable to implement into the radiotherapy clinic has been created. Unveiling these GI factors upfront will guide improved personalisation of radiotherapy.

3.
Clin Oncol (R Coll Radiol) ; 35(2): e135-e142, 2023 02.
Article in English | MEDLINE | ID: mdl-36336579

ABSTRACT

AIMS: Neoadjuvant chemoradiotherapy followed by surgery is the mainstay of treatment for patients with rectal cancer. Standard clinical target volume (CTV) to planning target volume (PTV) margins of 10 mm are used to accommodate inter- and intrafraction motion of target. Treating on magnetic resonance-integrated linear accelerators (MR-linacs) allows for online manual recontouring and adaptation (MRgART) enabling the reduction of PTV margins. The aim of this study was to investigate motion of the primary CTV (CTVA; gross tumour volume and macroscopic nodes with 10 mm expansion to cover microscopic disease) in order to develop a simultaneous integrated boost protocol for use on MR-linacs. MATERIALS AND METHODS: Patients suitable for neoadjuvant chemoradiotherapy were recruited for treatment on MR-linac using a two-phase technique; only the five phase 1 fractions on MR-linac were used for analysis. Intrafraction motion of CTVA was measured between pre-treatment and post-treatment MRI scans. In MRgART, isotropically expanded pre-treatment PTV margins from 1 to 10 mm were rigidly propagated to post-treatment MRI to determine overlap with 95% of CTVA. The PTV margin was considered acceptable if overlap was >95% in 90% of fractions. To understand the benefit of MRgART, the same methodology was repeated using a reference computed tomography planning scan for pre-treatment imaging. RESULTS: In total, nine patients were recruited between January 2018 and December 2020 with T3a-T4, N0-N2, M0 disease. Forty-five fractions were analysed in total. The median motion across all planes was 0 mm, demonstrating minimal intrafraction motion. A PTV margin of 3 and 5mm was found to be acceptable in 96 and 98% of fractions, respectively. When comparing to the computed tomography reference scan, the analysis found that PTV margins to 5 and 10 mm only acceptably covered 51 and 76% of fractions, respectively. CONCLUSION: PTV margins can be reduced to 3-5 mm in MRgART for rectal cancer treatment on MR-linac within an simultaneous integrated boost protocol.


Subject(s)
Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Rectal Neoplasms , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Tomography, X-Ray Computed , Rectal Neoplasms/diagnostic imaging , Rectal Neoplasms/radiotherapy , Rectal Neoplasms/pathology , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods
4.
Clin Transl Radiat Oncol ; 37: 85-88, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36118123

ABSTRACT

A shift of the daily plan can mitigate target position changes that occur between daily MR acquisition and treatment for MR-linac radiotherapy, but increases the session time. We demonstrated that our workflow strategy and decision-making process, to determine whether a subsequent shift is necessary, is appropriate.

5.
Clin Transl Radiat Oncol ; 35: 27-32, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35571274

ABSTRACT

Bladder tumour-focused magnetic resonance image-guided adaptive radiotherapy using a 1.5 Tesla MR-linac is feasible. A full online workflow adapting to anatomy at each fraction is achievable in approximately 30 min. Intra-fraction bladder filling did not compromise target coverage with the class solution employed.

6.
Clin Oncol (R Coll Radiol) ; 34(9): e383-e391, 2022 09.
Article in English | MEDLINE | ID: mdl-35469741

ABSTRACT

AIMS: Prostate morphological changes during external beam radiotherapy are poorly understood. Excellent soft-tissue visualisation offered by magnetic resonance image-guided radiotherapy (MRIgRT) provides an opportunity to better understand such changes. The aim of this study was to quantify prostate volume and dimension changes occurring during extreme and moderately hypofractionated schedules. MATERIALS AND METHODS: Forty prostate cancer patients treated on the Unity 1.5 Tesla magnetic resonance linear accelerator (MRL) were retrospectively reviewed. The cohort comprised patients treated with 36.25 Gy in five fractions (n = 20) and 60 Gy in 20 fractions (n = 20). The volume of the delineated prostates on reference planning computed tomography (fused with MRI) and daily T2-weighted 2-min session images acquired on Unity were charted. Forty planning computed tomography and 500 MRL prostate volumes were evaluated. The mean absolute and relative change in prostate volume during radiotherapy was compared using a paired t-test (P value <0.01 considered significant to control for multiple comparisons). The maximum dimension of the delineated prostate was measured in three isocentric planes. RESULTS: Significant prostate volume changes, relative to MRL imaging fraction 1 (MRL#1), were seen at all time points for the five-fraction group. The peak mean relative volume increase was 21% (P < 0.001), occurring at MRL#3 and MRL#4 after 14.5 and 21.75 Gy, respectively. Prostate expansion was greatest in the superior-inferior direction; the peak mean maximal extension was 5.9 mm. The maximal extension in the left-right and anterior-posterior directions measured 1.1 and 2.2 mm, respectively. For the 20-fraction group, prostate volume increased relative to MRL#1, for all treatment time points. The mean relative volume increase was 11% (P < 0.001) at MRL#5 after 12 Gy, it then fluctuated between 8 and 13%. From MRL#5 to MRL#20, the volume increase was significant (P < 0.01) for 12 of 16 time points calculated. The peak mean maximal extension in the superior-inferior direction was 3.1 mm. The maximal extension in the left-right and anterior-posterior directions measured 1.7 and 3.7 mm, respectively. CONCLUSION: Significant prostate volume and dimension changes occur during extreme and moderately hypofractionated radiotherapy. The extent of change was greater during extreme hypofractionation. MRIgRT offers the opportunity to reveal, quantify and correct for this deformation.


Subject(s)
Prostatic Neoplasms , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Male , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
7.
Clin Oncol (R Coll Radiol) ; 34(3): 151-159, 2022 03.
Article in English | MEDLINE | ID: mdl-34503896

ABSTRACT

AIMS: With interest in normal tissue sparing and dose-escalated radiotherapy in the treatment of inoperable locally advanced non-small cell lung cancer, this study investigated the impact of motion-managed moderate deep inspiration breath hold (mDIBH) on normal tissue sparing and dose-escalation potential and compared this to planning with a four-dimensional motion-encompassing internal target volume or motion-compensating mid-ventilation approach. MATERIALS AND METHODS: Twenty-one patients underwent four-dimensional and mDIBH planning computed tomography scans. Internal and mid-ventilation target volumes were generated on the four-dimensional scan, with mDIBH target volumes generated on the mDIBH scan. Isotoxic target dose-escalation guidelines were used to generate six plans per patient: three with a target dose cap and three without. Target dose-escalation potential, normal tissue complication probability and differences in pre-specified dose-volume metrics were evaluated for the three motion-management techniques. RESULTS: The mean total lung volume was significantly greater with mDIBH compared with four-dimensional scans. Lung dose (mean and V21 Gy) and mean heart dose were significantly reduced with mDIBH in comparison with four-dimensional-based approaches, and this translated to a significant reduction in heart and lung normal tissue complication probability with mDIBH. In 20/21 patients, the trial target prescription dose cap of 79.2 Gy was achievable with all motion-management techniques. CONCLUSION: mDIBH aids lung and heart dose sparing in isotoxic dose-escalated radiotherapy compared with four-dimensional planning techniques. Given concerns about lung and cardiac toxicity, particularly in an era of consolidation immunotherapy, reduced normal tissue doses may be advantageous for treatment tolerance and outcome.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Breath Holding , Carcinoma, Non-Small-Cell Lung/radiotherapy , Humans , Lung , Lung Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
8.
Clin Oncol (R Coll Radiol) ; 33(5): 307-313, 2021 05.
Article in English | MEDLINE | ID: mdl-33640196

ABSTRACT

AIMS: Target delineation uncertainty is arguably the largest source of geometric uncertainty in radiotherapy. Several factors can affect it, including the imaging modality used for delineation. It is accounted for by applying safety margins to the target to produce a planning target volume (PTV), to which treatments are designed. To determine the margin, the delineation uncertainty is measured as the delineation error, and then a margin recipe used. However, there is no published evidence of such analysis for recurrent gynaecological cancers (RGC). The aims of this study were first to quantify the delineation uncertainty for RGC gross tumour volumes (GTVs) and to calculate the associated PTV margins and then to quantify the difference in GTV, delineation uncertainty and PTV margin, between a computed tomography-magnetic resonance imaging (CT-MRI) and MRI workflow. MATERIALS AND METHODS: Seven clinicians delineated the GTV for 20 RGC tumours on co-registered CT and MRI datasets (CT-MRI) and on MRI alone. The delineation error, the standard deviation of distances from each clinician's outline to a reference, was measured and the required PTV margin determined. Differences between using CT-MRI and MRI alone were assessed. RESULTS: The overall delineation error and the resulting margin were 3.1 mm and 8.5 mm, respectively, for CT-MRI, reducing to 2.5 mm and 7.1 mm, respectively, for MRI alone. Delineation errors and therefore the theoretical margins, varied widely between patients. MRI tumour volumes were on average 15% smaller than CT-MRI tumour volumes. DISCUSSION: This study is the first to quantify delineation error for RGC tumours and to calculate the corresponding PTV margin. The determined margins were larger than those reported in the literature for similar patients, bringing into question both current margins and margin calculation methods. The wide variation in delineation error between these patients suggests that applying a single population-based margin may result in PTVs that are suboptimal for many. Finally, the reduced tumour volumes and safety margins suggest that patients with RGC may benefit from an MRI-only treatment workflow.


Subject(s)
Neoplasms , Radiotherapy Planning, Computer-Assisted , Humans , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Tumor Burden
9.
Clin Transl Radiat Oncol ; 25: 46-51, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33015380

ABSTRACT

Whole bladder magnetic resonance image-guided radiotherapy using the 1.5 Telsa MR-linac is feasible. Full online adaptive planning workflow based on the anatomy seen at each fraction was performed. This was delivered within 45 min. Intra-fraction bladder filling did not compromise target coverage. Patients reported acceptable tolerance of treatment.

10.
Phys Med Biol ; 65(9): 095003, 2020 05 04.
Article in English | MEDLINE | ID: mdl-32143198

ABSTRACT

Previous work has shown that PRESAGE® can be used successfully to perform 3D dosimetric measurements of complex radiotherapy treatments. However, measurements near the sample edges are known to be difficult to achieve. This is an issue when the doses at air-material interfaces are of interest, for example when investigating the electron return effect (ERE) present in treatments delivered by magnetic resonance (MR)-linac systems. To study this effect, a set of 3.5 cm-diameter cylindrical PRESAGE® samples was uniformly irradiated with multiple dose fractions, using either a conventional linac or an MR-linac. The samples were imaged between fractions using an optical-CT, to read out the corresponding accumulated doses. A calibration between TPS-predicted dose and optical-CT pixel value was determined for individual dosimeters as a function of radial distance from the axis of rotation. This data was used to develop a correction that was applied to four additional samples of PRESAGE® of the same formulation, irradiated with 3D-CRT and IMRT treatment plans, to recover significantly improved 3D measurements of dose. An alternative strategy was also tested, in which the outer surface of the sample was physically removed prior to irradiation. Results show that for the formulation studied here, PRESAGE® samples have a central region that responds uniformly and an edge region of 6-7 mm where there is gradual increase in dosimeter response, rising to an over-response of 24%-36% at the outer boundary. This non-uniform dose response increases in both extent and magnitude over time. Both mitigation strategies investigated were successful. In our four exemplar studies, we show how discrepancies at edges are reduced from 13%-37% of the maximum dose to between 2 and 8%. Quantitative analysis shows that the 3D gamma passing rates rise from 90.4, 69.3, 63.7 and 43.6% to 97.3, 99.9, 96.7 and 98.9% respectively.


Subject(s)
Imaging, Three-Dimensional/instrumentation , Lung Neoplasms/radiotherapy , Particle Accelerators/instrumentation , Phantoms, Imaging , Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Calibration , Gamma Rays , Humans , Imaging, Three-Dimensional/methods , Radiometry/methods , Radiotherapy Dosage , Radiotherapy, Conformal/methods
11.
Clin Oncol (R Coll Radiol) ; 31(1): 50-57, 2019 01.
Article in English | MEDLINE | ID: mdl-30361128

ABSTRACT

Geometric uncertainties in radiotherapy are conventionally addressed by defining a safety margin around the radiotherapy target. Misappropriation of such margins could result in disease recurrence from geometric miss or unnecessary irradiation of normal tissue. Numerous quantitative organ motion studies in adults have been published, but the first paediatric-specific studies were only published in recent years. In the very near future, intensity-modulated proton beam therapy and magnetic resonance-guided radiotherapy will be clinically implemented in the UK. Such techniques offer the ability to deliver radiotherapy to the pinnacle of precision and accuracy, if geometric uncertainty relating to internal organ motion and deformation can be optimally managed. The optimal margin to account for internal organ motion in children remains largely undefined. Continuing efforts to characterise motion in children and young people is necessary to optimally define safety margins and to realise the full potential of intensity-modulated radiotherapy, magnetic resonance-guided radiotherapy and intensity-modulated proton beam therapy. This overview offers a timely review of published reports on paediatric organ motion, in anticipation of the increasing application of advanced radiotherapy techniques in paediatric radiotherapy.


Subject(s)
Brain Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Adolescent , Child , Humans , Prognosis , Radiotherapy Dosage
12.
Phys Med Biol ; 63(21): 215019, 2018 10 29.
Article in English | MEDLINE | ID: mdl-30372420

ABSTRACT

Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of radiation to surrounding organs at risk (OARs). We expand on our previous work on beam-dependent margins and propose a novel adaptive margin concept, where margins are moulded away from selected OARs for better OAR-high-dose sparing, whilst maintaining similar dose coverage probability to the CTV. This, however, comes at a cost of a larger irradiation volume, and thus can negatively impact other structures. We investigate the impact of the adaptive margin concept when applied to prostate radiotherapy treatments, and compare treatment plans generated using our beam-dependent margins without adaptation, with adaption from the rectum and with adaptation from both the rectum and bladder. Five prostate patients were used in this planning study. All plans achieved similar dose coverage probability, and were able to ensure at least 90% population coverage with the target receiving at least 95% of the prescribed dose to [Formula: see text]. We observed overall better high-dose sparing to OARs that were considered when using the adapted beam-dependent PTVs, with the degree of sparing dependent on both the number of OARs under consideration as well as the relative position between the CTV and the OARs.


Subject(s)
Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Humans , Male , Probability , Prostatic Neoplasms/radiotherapy , Radiometry , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated , Rectum/radiation effects , Uncertainty
13.
Clin Oncol (R Coll Radiol) ; 30(11): 711-719, 2018 11.
Article in English | MEDLINE | ID: mdl-30201276

ABSTRACT

Adaptive radiotherapy (ART) strategies systematically monitor variations in target and neighbouring structures to inform treatment-plan modification during radiotherapy. This is necessary because a single plan designed before treatment is insufficient to capture the actual dose delivered to the target and adjacent critical structures during the course of radiotherapy. Magnetic resonance imaging (MRI) provides superior soft-tissue image contrast over current standard X-ray-based technologies without additional radiation exposure. With integrated MRI and radiotherapy platforms permitting motion monitoring during treatment delivery, it is possible that adaption can be informed by real-time anatomical imaging. This allows greater treatment accuracy in terms of dose delivered to target with smaller, individualised treatment margins. The use of functional MRI sequences would permit ART to be informed by imaging biomarkers, so allowing both personalised geometric and biological adaption. In this review, we discuss ART solutions enabled by MRI guidance and its potential gains for our patients across tumour types.


Subject(s)
Magnetic Resonance Imaging/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Humans
14.
Phys Med Biol ; 63(14): 145007, 2018 07 11.
Article in English | MEDLINE | ID: mdl-29882749

ABSTRACT

Owing to its excellent soft-tissue contrast, magnetic resonance (MR) imaging has found an increased application in radiation therapy (RT). By harnessing these properties for treatment planning, automated segmentation methods can alleviate the manual workload burden to the clinical workflow. We investigated atlas-based segmentation methods of organs at risk (OARs) in the head and neck (H&N) region using one approach that selected the most similar atlas from a library of segmented images and two multi-atlas approaches. The latter were based on weighted majority voting and an iterative atlas-fusion approach called STEPS. We built the atlas library from pre-treatment T1-weighted MR images of 12 patients with manual contours of the parotids, spinal cord and mandible, delineated by a clinician. Following a leave-one-out cross-validation strategy, we measured the geometric accuracy by calculating Dice similarity coefficients (DSC), standard and 95% Hausdorff distances (HD and HD95), and the mean surface distance (MSD), whereby the manual contours served as the gold standard. To benchmark the algorithm, we determined the inter-observer variability (IOV) between three observers. To investigate the dosimetric effect of segmentation inaccuracies, we implemented an auto-planning strategy within the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). For each set of auto-segmented OARs, we generated a plan for a 9-beam step and shoot intensity modulated RT treatment, designed according to our institution's clinical H&N protocol. Superimposing the dose distributions on the gold standard OARs, we calculated dose differences to OARs caused by delineation differences between auto-segmented and gold standard OARs. We investigated the correlations between geometric and dosimetric differences. The mean DSC was larger than 0.8 and the mean MSD smaller than 2 mm for the multi-atlas approaches, resulting in a geometric accuracy comparable to previously published results and within the range of the IOV. While dosimetric differences could be as large as 23% of the clinical goal, treatment plans fulfilled all imposed clinical goals for the gold standard OARs. Correlations between geometric and dosimetric measures were low with R2 < 0.5. The geometric accuracy and the ability to achieve clinically acceptable treatment plans indicate the suitability of using atlas-based contours for RT treatment planning purposes. The low correlations between geometric and dosimetric measures suggest that geometric measures alone are not sufficient to predict the dosimetric impact of segmentation inaccuracies on treatment planning for the data utilised in this study.


Subject(s)
Algorithms , Head and Neck Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Head and Neck Neoplasms/radiotherapy , Humans , Observer Variation , Radiometry , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
15.
J R Soc Interface ; 15(138)2018 01.
Article in English | MEDLINE | ID: mdl-29343635

ABSTRACT

Combined radiotherapy and hyperthermia offer great potential for the successful treatment of radio-resistant tumours through thermo-radiosensitization. Tumour response heterogeneity, due to intrinsic, or micro-environmentally induced factors, may greatly influence treatment outcome, but is difficult to account for using traditional treatment planning approaches. Systems oncology simulation, using mathematical models designed to predict tumour growth and treatment response, provides a powerful tool for analysis and optimization of combined treatments. We present a framework that simulates such combination treatments on a cellular level. This multiscale hybrid cellular automaton simulates large cell populations (up to 107 cells) in vitro, while allowing individual cell-cycle progression, and treatment response by modelling radiation-induced mitotic cell death, and immediate cell kill in response to heating. Based on a calibration using a number of experimental growth, cell cycle and survival datasets for HCT116 cells, model predictions agreed well (R2 > 0.95) with experimental data within the range of (thermal and radiation) doses tested (0-40 CEM43, 0-5 Gy). The proposed framework offers flexibility for modelling multimodality treatment combinations in different scenarios. It may therefore provide an important step towards the modelling of personalized therapies using a virtual patient tumour.


Subject(s)
Cell Cycle/radiation effects , Gamma Rays , Hyperthermia, Induced , Models, Biological , Neoplasms , Cell Survival/radiation effects , Combined Modality Therapy , HCT116 Cells , Humans , Neoplasms/metabolism , Neoplasms/pathology , Neoplasms/therapy
17.
Phys Med Biol ; 62(12): 4917-4928, 2017 Jun 21.
Article in English | MEDLINE | ID: mdl-28379156

ABSTRACT

Radiotherapy treatment planning for use with high-energy photon beams currently employs a binary approach in defining the planning target volume (PTV). We propose a margin concept that takes the beam directions into account, generating beam-dependent PTVs (bdPTVs) on a beam-by-beam basis. The resulting degree of overlaps between the bdPTVs are used within the optimisation process; the optimiser effectively considers the same voxel to be both target and organ at risk (OAR) with fractional contributions. We investigate the impact of this novel approach when applied to prostate radiotherapy treatments, and compare treatment plans generated using beam dependent margins to conventional margins. Five prostate patients were used in this planning study, and plans using beam dependent margins improved the sparing of high doses to target-surrounding OARs, though a trade-off in delivering additional low dose to the OARs can be observed. Plans using beam dependent margins are observed to have a slightly reduced target coverage. Nevertheless, all plans are able to satisfy 90% population coverage with the target receiving at least 95% of the prescribed dose to [Formula: see text].


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Humans , Male , Organs at Risk/radiation effects , Photons/adverse effects , Photons/therapeutic use , Probability , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage
18.
Phys Med ; 35: 7-17, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28242137

ABSTRACT

BACKGROUND AND PURPOSE: Computed tomography (CT) imaging is the current gold standard for radiotherapy treatment planning (RTP). The establishment of a magnetic resonance imaging (MRI) only RTP workflow requires the generation of a synthetic CT (sCT) for dose calculation. This study evaluates the feasibility of using a multi-atlas sCT synthesis approach (sCTa) for head and neck and prostate patients. MATERIAL AND METHODS: The multi-atlas method was based on pairs of non-rigidly aligned MR and CT images. The sCTa was obtained by registering the MRI atlases to the patient's MRI and by fusing the mapped atlases according to morphological similarity to the patient. For comparison, a bulk density assignment approach (sCTbda) was also evaluated. The sCTbda was obtained by assigning density values to MRI tissue classes (air, bone and soft-tissue). After evaluating the synthesis accuracy of the sCTs (mean absolute error), sCT-based delineations were geometrically compared to the CT-based delineations. Clinical plans were re-calculated on both sCTs and a dose-volume histogram and a gamma analysis was performed using the CT dose as ground truth. RESULTS: Results showed that both sCTs were suitable to perform clinical dose calculations with mean dose differences less than 1% for both the planning target volume and the organs at risk. However, only the sCTa provided an accurate and automatic delineation of bone. CONCLUSIONS: Combining MR delineations with our multi-atlas CT synthesis method could enable MRI-only treatment planning and thus improve the dosimetric and geometric accuracy of the treatment, and reduce the number of imaging procedures.


Subject(s)
Atlases as Topic , Magnetic Resonance Imaging/methods , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Feasibility Studies , Humans , Male , Oropharyngeal Neoplasms/diagnostic imaging , Oropharyngeal Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
19.
Phys Med Biol ; 62(10): 3902-3922, 2017 05 21.
Article in English | MEDLINE | ID: mdl-28333689

ABSTRACT

Microbeam Radiation Therapy is an innovative pre-clinical strategy which uses arrays of parallel, tens of micrometres wide kilo-voltage photon beams to treat tumours. These x-ray beams are typically generated on a synchrotron source. It was shown that these beam geometries allow exceptional normal tissue sparing from radiation damage while still being effective in tumour ablation. A final biological explanation for this enhanced therapeutic ratio has still not been found, some experimental data support an important role of the vasculature. In this work, the effect of microbeams on a normal microvascular network of the cerebral cortex was assessed in computer simulations and compared to the effect of homogeneous, seamless exposures at equal energy absorption. The anatomy of a cerebral microvascular network and the inflicted radiation damage were simulated to closely mimic experimental data using a novel probabilistic model of radiation damage to blood vessels. It was found that the spatial dose fractionation by microbeam arrays significantly decreased the vascular damage. The higher the peak-to-valley dose ratio, the more pronounced the sparing effect. Simulations of the radiation damage as a function of morphological parameters of the vascular network demonstrated that the distribution of blood vessel radii is a key parameter determining both the overall radiation damage of the vasculature and the dose-dependent differential effect of microbeam irradiation.


Subject(s)
Cerebral Cortex/blood supply , Computer Simulation , Microvessels/radiation effects , Humans , Radiation Dosage , Synchrotrons , X-Rays
20.
Phys Med Biol ; 62(1): 186-201, 2017 01 07.
Article in English | MEDLINE | ID: mdl-27991457

ABSTRACT

In radiotherapy, abdominal and thoracic sites are candidates for performing motion tracking. With real-time control it is possible to adjust the multileaf collimator (MLC) position to the target position. However, positions are not perfectly matched and position errors arise from system delays and complicated response of the electromechanic MLC system. Although, it is possible to compensate parts of these errors by using predictors, residual errors remain and need to be compensated to retain target coverage. This work presents a method to statistically describe tracking errors and to automatically derive a patient-specific, per-segment margin to compensate the arising underdosage on-line, i.e. during plan delivery. The statistics of the geometric error between intended and actual machine position are derived using kernel density estimators. Subsequently a margin is calculated on-line according to a selected coverage parameter, which determines the amount of accepted underdosage. The margin is then applied onto the actual segment to accommodate the positioning errors in the enlarged segment. The proof-of-concept was tested in an on-line tracking experiment and showed the ability to recover underdosages for two test cases, increasing [Formula: see text] in the underdosed area about [Formula: see text] and [Formula: see text], respectively. The used dose model was able to predict the loss of dose due to tracking errors and could be used to infer the necessary margins. The implementation had a running time of 23 ms which is compatible with real-time requirements of MLC tracking systems. The auto-adaptivity to machine and patient characteristics makes the technique a generic yet intuitive candidate to avoid underdosages due to MLC tracking errors.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Automation , Humans , Motion , Patient Positioning , Radiotherapy Setup Errors , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL