1.
Physiol Rep ; 11(12): e15729, 2023 06.
Article in English | MEDLINE | ID: mdl-37332077

ABSTRACT

Non-invasive technologies have become popular for the clinical evaluation of cardiac function. The present study evaluated hemodynamic response to cardiopulmonary exercise stress testing using bioreactance technology in patients with hypertrophic cardiomyopathy. The study included 29 patients with HCM (age 55 ± 15 years; 28% female) and 12 age (55 ± 14 years), and gender matched (25% female) healthy controls. All participants underwent maximal graded cardiopulmonary exercise stress testing with simultaneous non-invasive hemodynamic bioreactance and gas exchange. At rest, patients with HCM demonstrated significantly lower cardiac output (4.1 ± 1.3 vs. 6.1 ± 1.2 L/min; p < 0.001), stroke volume (61.5 ± 20.8 vs. 89.5 ± 19.8 mL/beat; p < 0.001), and cardiac power output (0.97 ± 0.3 vs. 1.4 ± 0.3watt; p < 0.001), compared to controls. At peak exercise, the following hemodynamic and metabolic variables were lower in HCM patients that is, heart rate (118 ± 29 vs. 156 ± 20 beats/min; p < 0.001), cardiac output (15.5 ± 5.8 vs. 20.5 ± 4.7 L/min; p = 0.017), cardiac power output (4.3 ± 1.6 vs. 5.9 ± 1.8 watts; p = 0.017), mean arterial blood pressure (126 ± 11 vs. 134 ± 10 mmHg; p = 0.039), and oxygen consumption (18.3 ± 6.0 vs. 30.5 ± 8.3 mL/kg/min; p < 0.001), respectively. Peak arteriovenous oxygen difference and stroke volume were not significantly different between HCM patients and healthy controls (11.2 ± 6.4 vs. 11.9 ± 3.1 mL/100 mL, p = 0.37 and 131 ± 50.6 vs. 132 ± 41.9 mL/beat, p = 0.76). There was a moderate positive relationship between peak oxygen consumption and peak heart rate (r = 0.67, p < 0.001), and arteriovenous oxygen difference (r = 0.59, p = 0.001). Functional capacity is significantly reduced in patients with HCM primarily due to diminished central (cardiac) rather than peripheral factors. Application of non-invasive hemodynamic assessment may improve understanding of the pathophysiology and explain mechanisms of exercise intolerance in hypertrophic cardiomyopathy.


Subject(s)
Cardiomyopathy, Hypertrophic , Humans , Female , Adult , Middle Aged , Aged , Male , Cardiomyopathy, Hypertrophic/diagnosis , Hemodynamics/physiology , Heart , Cardiac Output , Stroke Volume/physiology , Exercise Test , Oxygen Consumption/physiology
2.
Int J Sports Med ; 40(2): 125-132, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30605923

ABSTRACT

The present study evaluated reproducibility of the inert gas rebreathing method to estimate cardiac output at rest and during cardiopulmonary exercise testing. Thirteen healthy subjects (10 males, 3 females, ages 23-32 years) performed maximal graded cardiopulmonary exercise stress test using a cycle ergometer on 2 occasions (Test 1 and Test 2). Participants cycled at 30-watts/3-min increments until peak exercise. Hemodynamic variables were assessed at rest and during different exercise intensities (i. e., 60, 120, 150, 180 watts) using an inert gas rebreathing technique. Cardiac output and stroke volume were not significantly different between the 2 tests at rest 7.4 (1.6) vs. 7.1 (1.2) liters min-1, p=0.54; 114 (28) vs. 108 (15) ml beat-1, p=0.63) and all stages of exercise. There was a significant positive relationship between Test 1 and Test 2 cardiac outputs when data obtained at rest and during exercise were combined (r=0.95, p<0.01 with coefficient of variation of 6.0%), at rest (r=0.90, p<0.01 with coefficient of variation of 5.1%), and during exercise (r=0.89, p<0.01 with coefficient of variation 3.3%). The mean difference and upper and lower limits of agreement between repeated measures of cardiac output at rest and peak exercise were 0.4 (-1.1 to 1.8) liter min-1 and 0.5 (-2.3 to 3.3) liter min-1, respectively. The inert gas rebreathing method demonstrates an acceptable level of test-retest reproducibility for estimating cardiac output at rest and during cardiopulmonary exercise testing at higher metabolic demands.


Subject(s)
Cardiac Output , Exercise Test , Adult , Breath Tests , Female , Humans , Male , Noble Gases , Pulmonary Gas Exchange , Reproducibility of Results , Rest , Stroke Volume , Young Adult