Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Clin Microbiol Infect Dis ; 43(5): 959-968, 2024 May.
Article in English | MEDLINE | ID: mdl-38517573

ABSTRACT

PURPOSE: To assess Gram-positive bacterial (GPB) bloodstream infection (BSI) in neonates, covering incidence, morbidity, mortality, antimicrobial resistance patterns and biomarkers in Region Stockholm, Sweden between 2006 and 2016. METHODS: A population-based retrospective epidemiological study including infants with GPB-BSI, admitted to the neonatal units at Karolinska University Hospital (KUH). Data were collected from patient records, the Swedish Neonatal Quality Register, the microbiological laboratory at KUH and the Swedish Public Health Agency. RESULTS: We identified 357 infants with GPB-BSI, representing an incidence of 1.47/1000 live births (LB). Group B streptococcus (GBS) was the most common pathogen causing BSI in full-term infants and early-onset sepsis (EOS) (0.20/1000 LB), while coagulase-negative staphylococci (CoNS) were predominant in infants born very preterm and in late-onset sepsis (LOS) (0.79/1000 LB). There were no fatal GBS BSI cases, but 10.2% developed meningitis. The GPB case fatality rate was 9.5% and the sepsis fatality rate 2.8%. In GPB-BSI, 1/10 did not have an elevated C-reactive protein level. Staphylococcus aureus (S. aureus) BSI increased during the study period, but no methicillin or vancomycin resistant strains were found. The antimicrobial resistance (AMR) rate was highest in CoNS isolates. CONCLUSION: GPB-BSI was four times more common than Gram-negative BSI in neonates but resulted in lower mortality rate. GBS was the most common pathogen in full-term infants and in EOS. CoNS was the most common pathogen in LOS and infants born very preterm, and the AMR rate was high in these isolates. The increasing trend of S. aureus BSI indicates a need of further investigation.


Subject(s)
Gram-Positive Bacteria , Gram-Positive Bacterial Infections , Neonatal Sepsis , Humans , Sweden/epidemiology , Infant, Newborn , Neonatal Sepsis/microbiology , Neonatal Sepsis/epidemiology , Neonatal Sepsis/mortality , Retrospective Studies , Female , Male , Gram-Positive Bacteria/drug effects , Gram-Positive Bacteria/isolation & purification , Gram-Positive Bacteria/classification , Incidence , Gram-Positive Bacterial Infections/epidemiology , Gram-Positive Bacterial Infections/microbiology , Gram-Positive Bacterial Infections/mortality , Gram-Negative Bacteria/drug effects , Gram-Negative Bacteria/isolation & purification , Gram-Negative Bacteria/classification , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/pharmacology , Drug Resistance, Bacterial , Gram-Negative Bacterial Infections/epidemiology , Gram-Negative Bacterial Infections/microbiology , Gram-Negative Bacterial Infections/mortality , Streptococcus agalactiae/isolation & purification , Streptococcus agalactiae/drug effects
2.
Front Pediatr ; 10: 866762, 2022.
Article in English | MEDLINE | ID: mdl-35463903

ABSTRACT

Introduction: In this case report, we describe an extended-spectrum beta-lactamase (ESBL) - Escherichia coli (E. coli) strain of sequence type (ST) 1193, a novel, virulent, multidrug-resistant (MDR) clone with a rapid global spread. ST 1193 has been more commonly associated with invasive disease than other ESBL-E. coli STs. To our knowledge, this is the first known case in Sweden where a newborn died of an ESBL-E. coli ST 1193 meningitis. We emphasize that the clinical knowledge about the properties of certain MDR-clones should be increased. Case Report: A moderately preterm boy was born after preterm prolonged rupture of membranes. The mother had an ESBL-E. coli urinary tract infection during pregnancy. At 36 h of age he developed signs of infection and was given first-line therapy for early onset sepsis. Thereafter he developed seizures. The treatment was changed to cover suspected meningitis. Culture showed growth of the same ESBL- E. coli ST 1193 strain in the child's blood and cerebrospinal fluid, as well as in the mother's urine. Antibiotics were adapted. His condition deteriorated and he developed fulminant septic shock with treatment-resistant seizures. The boy passed away at 3 days of age. Conclusion: This case highlights the risk of delay in diagnosis when a marking for carriage of MDR-bacteria is falsely removed from a medical record of a pregnant women. Further, it demonstrates that ESBL-E. coli ST 1193 infection in neonates can be fatal. Thus, studies regarding virulence factors of ESBL-E. coli infections in pregnant women and their children are needed to understand the association between this infection and severe invasive disease in newborn children.

SELECTION OF CITATIONS
SEARCH DETAIL
...