Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Radiographics ; 21(6): 1519-31, 2001.
Article in English | MEDLINE | ID: mdl-11706222

ABSTRACT

Venous malformations are the most common vascular malformations. However, confusion with respect to terminology and imaging guidelines continues to result in improper diagnosis and treatment. An appropriate classification scheme for vascular anomalies is important to avoid the use of false generic terms. Adequate imaging in association with clinical findings is crucial to establishing the correct diagnosis. Doppler ultrasonography should be the initial imaging modality and demonstrates absence of flow or low-velocity venous flow. Computed tomography and magnetic resonance (MR) imaging are used primarily for pretreatment evaluation of lesion extension. These lesions are usually hypointense on T1-weighted MR images and markedly hyperintense on T2-weighted images with variable gadolinium enhancement. Direct phlebography helps confirm the diagnosis and exclude other soft-tissue tumors. Three distinct phlebographic patterns (cavitary, spongy, dysmorphic) have been identified. In most cases, conservative treatment is recommended. Sclerotherapy with or without surgery is useful in cases of functional impairment or significant aesthetic prejudice, even if recurrences are frequent. Direct phlebography is performed when a more detailed assessment of the vascular pattern is needed or as part of sclerotherapy. Use of the appropriate imaging technique is critical in establishing the diagnosis, evaluating extension, and planning appropriate treatment.


Subject(s)
Veins/abnormalities , Arteriovenous Malformations/diagnosis , Arteriovenous Malformations/diagnostic imaging , Arteriovenous Malformations/therapy , Humans , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Ultrasonography
2.
AJR Am J Roentgenol ; 177(5): 1123-9, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11641186

ABSTRACT

OBJECTIVE: The objective of our study was to compare the value of captopril-enhanced Doppler sonography, captopril-enhanced renal scintigraphy, and gadolinium-enhanced MR angiography for detecting renal artery stenosis. SUBJECTS AND METHODS: Forty-one patients with suspected renovascular hypertension were prospectively examined with captopril-enhanced Doppler sonography, captopril-enhanced renal scintigraphy, gadolinium-enhanced MR angiography, and catheter angiography. The sensitivity and specificity of each technique for detecting renal artery stenosis measuring 50% or greater and 70% or greater were compared using the McNemar test. Positive and negative predictive values were estimated for populations with 5% and 30% prevalence of renal artery stenosis. Kappa values for interobserver agreement were assessed for both gadolinium-enhanced MR angiography and catheter angiography. RESULTS: For detecting renal artery stenosis measuring 50% or greater, the sensitivity of gadolinium-enhanced MR angiography (96.6%) was greater than that of captopril-enhanced Doppler sonography (69%, p = 0.005) and captopril-enhanced renal scintigraphy (41.4%, p = 0.001). No significant difference in specificity was observed among modalities. For renal artery stenosis measuring 50% or greater, positive and negative predictive values were respectively 62% and 86% for captopril-enhanced Doppler sonography, 49% and 76% for captopril-enhanced renal scintigraphy, and 53% and 98% for gadolinium-enhanced MR angiography. Interobserver agreement was high for both gadolinium-enhanced MR angiography (kappa = 0.829) and catheter angiography (kappa = 0.729). CONCLUSION: Gadolinium-enhanced MR angiography is the most accurate noninvasive modality for detecting renal artery stenosis greater than or equal to 50%. The use of captopril-enhanced Doppler sonography in combination with gadolinium-enhanced MR angiography for identifying renal artery stenosis needs to be evaluated with a cost-effectiveness analysis.


Subject(s)
Captopril , Image Enhancement , Magnetic Resonance Angiography , Radioisotope Renography , Renal Artery Obstruction/diagnosis , Ultrasonography, Doppler , Adult , Aged , Angiography , Female , Humans , Hypertension, Renovascular/diagnosis , Male , Middle Aged , Observer Variation , Prospective Studies , Sensitivity and Specificity , Technetium Tc 99m Mertiatide
3.
J Vasc Interv Radiol ; 12(9): 1053-8, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11535767

ABSTRACT

PURPOSE: To report data collected by the Canadian Registry of the Günther Tulip Retrievable Filter (GTF). MATERIALS AND METHODS: Between February 1998 and December 2000, 90 patients at eight hospitals underwent implantation of 91 GTFs. There were 45 male patients and 45 female patients, age 17-88 years, with a mean age of 49 years. Indications for filter placement were pulmonary embolism (PE) or deep vein thrombosis (DVT) with a contraindication to anticoagulation in 83 patients, prophylaxis after massive PE in one, prophylaxis for proximal free-floating thrombus in one, and prophylaxis with no DVT or PE in six patients (major trauma, n = 4; high preoperative risk, n = 2). GTF retrieval was attempted in selected patients from a right internal jugular vein approach. RESULTS: One GTF was inadvertently placed in the right iliac vein and could not be retrieved. There were no other major placement complications. GTF retrieval was attempted in 52 patients (53 GTFs); 52 GTFs were successfully retrieved from 51 patients. Implantation times were 2-25 days (mean, 9 d). Of these 51 patients, 37 underwent follow-up for 5-420 days (mean, 103 d) after filter retrieval. Four patients (8% of retrieved GTFs) required reinsertion of a permanent filter 17-167 days (mean, 78 d) after GTF retrieval as a result of bleeding from anticoagulation (n = 2) or because the patient required further surgery (n = 2). One other patient had recurrent DVT 230 days after retrieval; no PE or other complication was documented in the retrieval group. GTFs were not retrieved from 39 patients for various reasons. Of these 39 patients, 25 underwent follow-up 7-420 days (mean, 85 d) after filter placement. Two patients developed filter occlusion (5%); no other complications were documented. CONCLUSION: The GTF has a broad range of utility: it can be used as a permanent filter or retrieved after implantation periods of 15 days and possibly longer. However, indications for retrieval require further study, as does the maximum implantation time.


Subject(s)
Pulmonary Embolism/therapy , Vena Cava Filters/statistics & numerical data , Vena Cava, Inferior/diagnostic imaging , Venous Thrombosis/therapy , Adolescent , Adult , Aged , Aged, 80 and over , Canada , Female , Humans , Male , Middle Aged , Prosthesis Design , Radiography, Interventional , Registries , Retrospective Studies , Safety , Societies, Medical , Vena Cava Filters/adverse effects
5.
Radiology ; 219(3): 655-62, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11376250

ABSTRACT

PURPOSE: To evaluate the long-term clinical and hemodynamic effectiveness of aortic stent placement in cases of failure of intended infrarenal percutaneous transluminal aortic angioplasty (PTAA). MATERIALS AND METHODS: Fifty-three patients who underwent technically successful PTAA were compared with 24 patients who underwent aortic stent placement because of PTAA failure (19 patients) or ulcerated lesions (five patients) that otherwise would have been treated surgically because of the embolization hazard associated with PTAA alone. Clinical patency was defined as the absence or improvement of symptoms after the intervention. Hemodynamic patency was defined as a normal Doppler waveform in the common femoral arteries, an ankle-brachial index greater than 0.95, or the absence of a thigh-brachial pressure gradient. RESULTS: Three-year clinical and hemodynamic patency rates, respectively, were 85% and 79% for PTAA and 69% and 43% for aortic stent placement. No morbidity was encountered. With use of the Cox proportional hazards model, two significant risk factors were retained for restenosis: unchanged smoking habit (P =.04) and small dilatation diameter (P =.001). Aortic stent placement, performed in patients with a smaller aortic diameter (10.3 vs. 12.7 mm for PTAA), appeared to be a predictive factor for restenosis by using univariate analysis. By using the Cox proportional hazards model, however, the restenosis rates after PTAA and aortic stent placement were not significantly different. CONCLUSION: When aortic diameter is taken into consideration, there is no evidence that clinical outcome after secondary aortic stent placement would be poorer than technically successful PTAA.


Subject(s)
Angioplasty, Balloon , Aortic Diseases/therapy , Arterial Occlusive Diseases/therapy , Stents , Aorta, Abdominal , Case-Control Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Proportional Hazards Models , Recurrence , Risk Factors , Smoking/adverse effects , Time Factors , Treatment Failure , Vascular Patency
6.
AJR Am J Roentgenol ; 176(6): 1415-20, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11373204

ABSTRACT

OBJECTIVE: This study was designed to define and evaluate a specific index to quantify arterial obstruction with helical CT in acute pulmonary embolism. MATERIALS AND METHODS: Fifty-four patients (mean age, 56 years) with proven pulmonary emboli among 158 consecutive patients, who had undergone both CT and pulmonary angiography for clinically suspected pulmonary embolism, were eligible for the study. The CT obstruction index was defined as (n. d) (n, value of the proximal clot site, equal to the number of segmental branches arising distally; d, degree of obstruction scored as partial obstruction [value of 1] or total obstruction [value of 2]). We compared the CT obstruction index with pulmonary arterial obstruction on angiography (assessed by the Miller index), using linear regression, and correlated it with findings on echocardiography. Interobserver variability was determined for both CT and pulmonary angiography indexes. RESULTS: The CT obstruction index (29% +/- 17%) and the Miller index (43% +/- 25%) were well correlated (r = 0.867, p < 0.0001) with an excellent concordance between investigators for both the CT index (r = 0.944, p < 0.0001) and the Miller index (r = 0.904, p < 0.0001). A CT obstruction index greater than 40% identified more than 90% of patients with right ventricular dilatation. CONCLUSION: The degree of arterial obstruction in pulmonary embolism may be quantified by a specific CT index that appears reproducible and highly correlated to the previously described index with pulmonary angiography. Further evaluations are needed to investigate the usefulness of the CT obstruction index for stratification of patient risk and determining therapeutic options.


Subject(s)
Pulmonary Artery/diagnostic imaging , Pulmonary Embolism/diagnostic imaging , Tomography, X-Ray Computed , Angiography , Echocardiography , Female , Humans , Linear Models , Male , Middle Aged , Observer Variation , Tomography, X-Ray Computed/methods
7.
J Comput Assist Tomogr ; 25(2): 278-86, 2001.
Article in English | MEDLINE | ID: mdl-11242229

ABSTRACT

PURPOSE: The purpose of this work was to determine the reproducibility of coronary total calcium score (TCS) with dual-slice helical CT and compare three acquisition protocols. METHOD: Fifty patients (59 +/- 10 years old) underwent dual-slice helical CT (collimation = 2 x 2.5 mm) and coronary angiography. Two successive scans were performed, resulting in three sets of images: pitch = 1, 360 degrees linear interpolation (LI) (A360); pitch = 1, 180 degrees LI (A180); and pitch = 1.5, 180 degrees LI (B180). TCS values, calculated using a volumetric method with a threshold of 90 HU, were compared, and the interscan variation was determined. Diagnostic performances were compared with receiver operating characteristic curves. RESULTS: Protocol A360 provided significantly lower TCS than protocols A180 and B180 (p < 0.0001). No statistical difference was seen between A180 and B180, which provided the lowest interscan variation (40 +/- 58%). However, no significant clinical impact of the observed interscan variations was found. CONCLUSION: Reproducibility of TCS with dual-slice helical CT is improved by the 180 LI algorithm. However, dual-slice helical CT is not sufficiently reproducible to allow serial quantification of TCS over time.


Subject(s)
Calcinosis/diagnostic imaging , Coronary Disease/diagnostic imaging , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Algorithms , Cineangiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Middle Aged , ROC Curve , Reproducibility of Results , Sensitivity and Specificity
8.
J Vasc Interv Radiol ; 12(2): 195-200, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11265883

ABSTRACT

PURPOSE: To identify predictors of clinical outcome after arterial embolotherapy for upper gastrointestinal (UGI) hemorrhage. MATERIALS AND METHODS: Seventy-five consecutive patients (mean age, 62.5 y) underwent arterial embolization for acute UGI hemorrhage. Bleeding was detected at endoscopy and angiography in 22 patients, at endoscopy alone in 29 patients, and at angiography alone in 24 patients. As such, embolization was directed by angiography in 46 patients (61.3%) and by endoscopy (referred to as "blind" embolization) in 29 patients (38.7%). The embolic agents used were metallic coils, polyvinyl alcohol particles (size range, 355-710 microm), gelatin sponge, and tissue adhesive. Predictors of bleeding recurrence and mortality were analyzed with logistic regression and Cox models, respectively. RESULTS: The technical success rate of embolization was 98.7%. Primary clinical success was achieved in 57 patients (76%). Secondary clinical success occurred in five additional patients (82.5%) after repeat embolization. There were four (5.3%) complications: two cases of self-resolving duodenal ischemia, one hepatic infarct, and one inguinal hematoma. The periprocedural mortality rate was 34.6% (26 of 75), mostly related to underlying illness. Early recurrence of bleeding (within 30 days of embolization) was associated with coagulation disorders (international normalized ratio >1.5, partial thromboplastin time >45 seconds, or platelet count <80,000/microL; odds ratio, 19.46; P = .001) and with the use of coils as the only embolic agent (odds ratio, 7.73; P = .01). Cirrhosis and cancer shortened the overall survival of patients after embolic therapy. The mean patient follow-up time was 34.5 months. CONCLUSION: Arterial embolotherapy for UGI hemorrhage is safe, effective, and durable. Coagulopathy and the use of coils as the only embolic agent were associated with a higher risk of early bleeding recurrence.


Subject(s)
Embolization, Therapeutic , Gastrointestinal Hemorrhage/therapy , Blood Coagulation Disorders/complications , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/methods , Female , Follow-Up Studies , Gastrointestinal Hemorrhage/mortality , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Proportional Hazards Models , Recurrence , Retrospective Studies , Risk Factors , Time Factors
9.
Radiographics ; 20(5): 1355-68; discussion 1368-72, 2000.
Article in English | MEDLINE | ID: mdl-10992024

ABSTRACT

Renovascular hypertension affects 15%-30% of patients who have clinical criteria suggestive of renovascular disease. Noninvasive screening is crucial for patient selection prior to conventional angiography and renal revascularization. Renal scintigraphy has been reported to be sensitive for detection of renovascular hypertension, but some of its limitations (eg, in the setting of bilateral renal artery stenosis and renal failure) should be considered. Doppler ultrasonography (US) allows direct evaluation of the renal arteries as well as transrenal Doppler waveform analysis, but it remains operator dependent. Gadolinium-enhanced magnetic resonance (MR) angiography is becoming an excellent alternative to conventional angiography. The main limiting factors of this technique are inadequate visualization of segmental and accessory renal arteries as well as a tendency toward overestimation of stenoses. Given the high cost and low availability of MR angiography, scintigraphy and Doppler US should be considered the primary studies in screening for renovascular hypertension. MR angiography could be reserved for patients with inconclusive scintigraphic and Doppler US results, patients with high clinical suspicion of renovascular hypertension, and patients with a contraindication to conventional angiography.


Subject(s)
Hypertension, Renovascular/diagnosis , Magnetic Resonance Angiography , Radionuclide Imaging , Ultrasonography, Doppler , Evaluation Studies as Topic , Humans , Reproducibility of Results
10.
J Vasc Interv Radiol ; 11(6): 713-20, 2000 Jun.
Article in English | MEDLINE | ID: mdl-10877415

ABSTRACT

PURPOSE: To identify predictors of clinical outcome after percutaneous revascularization of the renal arteries. MATERIALS AND METHODS: In 63 patients, the therapeutic response was retrospectively assessed after percutaneous revascularization of the renal arteries indicated for hypertension (41.3%), renal failure (4.8%), or both (53.9%). All patients underwent percutaneous transluminal renal angioplasty, complemented by stent insertion in 30 patients. The authors analyzed the role of clinical and imaging factors, including scintigraphy, Doppler sonography, and angiography for predicting clinical success. RESULTS: In the hypertensive population, there were three cures (5.6%), 26 improvements (48.1%), and 25 failures (46.3%). Among patients with renal insufficiency, 12 were improved (37.5%), 11 were stabilized (34.4%), and nine deteriorated (28.1%). Predictors of favorable outcome for hypertension were shorter duration of hypertension, higher diastolic blood pressure, fibromuscular dysplasia, abnormal Doppler study, higher percentage of angiographic stenosis, and lower grade of aortic atheromatous disease. Predictors of favorable outcome for renal failure were nondiabetic status, abnormal Doppler study, and higher percentage of angiographic stenosis. Abnormal Doppler and scintigraphic examinations predicted successful treatment of hypertension in 60% and 53.8% of cases, respectively, and renal insufficiency in 85% and 60% of cases, respectively. CONCLUSION: Clinical and angiographic variables were the best predictors of therapeutic success for hypertension. Doppler sonography was useful in patients with renal failure.


Subject(s)
Angioplasty, Balloon/methods , Renal Artery Obstruction/therapy , Angiography , Female , Humans , Hypertension, Renovascular/diagnosis , Hypertension, Renovascular/etiology , Hypertension, Renovascular/therapy , Male , Middle Aged , Prognosis , Renal Artery Obstruction/complications , Renal Artery Obstruction/diagnosis , Renal Insufficiency/diagnosis , Renal Insufficiency/etiology , Renal Insufficiency/therapy , Retrospective Studies , Ultrasonography, Doppler
11.
J Vasc Interv Radiol ; 10(6): 723-31, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10392939

ABSTRACT

PURPOSE: To compare the diagnostic value of carbon dioxide to that of iodinated contrast material for digital subtraction angiography of the abdominal aorta and lower extremities. MATERIALS AND METHODS: Thirty-five patients underwent comparative CO2 and iodinated contrast material arteriography of the abdominal aorta and lower extremities. For each contrast study, three independent observers evaluated the degree of opacification and percentage of stenosis of each vessel, the degree of certainty of their observations, and the overall quality of the study. Data of CO2 and iodinated studies were compared using analysis of variance for repeated measures. Interobserver and intertechnique agreements were estimated with Cohen's kappa and intraclass correlation coefficient. RESULTS: Iodine-based vascular opacification was superior to that with CO2 in the central and distal arteries (P = .02). The degree of certainty and overall quality score were higher for iodine than for CO2-based contrast studies (P = .00001). The interobserver agreement for categorizing stenoses was higher for iodine as compared to CO2-based angiography. No significant difference was observed between the mean stenosis values obtained with CO2 and iodine-based angiography in any segment. Intraclass correlation coefficient demonstrated a high degree of convergence of the two techniques for assessing the percentage of stenosis. CONCLUSION: CO2 can be used as an alternative to iodinated contrast material for obtaining arteriograms of the abdominal aorta and lower extremities for investigating atherosclerotic disease.


Subject(s)
Angiography, Digital Subtraction , Aorta, Abdominal/diagnostic imaging , Carbon Dioxide , Contrast Media , Leg/blood supply , Triiodobenzoic Acids , Aged , Aged, 80 and over , Analysis of Variance , Aortic Diseases/diagnostic imaging , Arterial Occlusive Diseases/diagnostic imaging , Arteriosclerosis/diagnostic imaging , Cohort Studies , Female , Femoral Artery/diagnostic imaging , Humans , Iliac Artery/diagnostic imaging , Male , Middle Aged , Observer Variation , Popliteal Artery/diagnostic imaging , Prospective Studies , Radiographic Image Enhancement/methods , Single-Blind Method
12.
J Neuroradiol ; 26(1): 7-20, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10363438

ABSTRACT

PURPOSE: The purpose of this work is to better define healing phenomena in this model, in an effort to find strategies to improve long term results of endovascular treatment. METHODS: Lateral wall venous pouch aneurysms were constructed on both carotid arteries in 30 pigs. The aneurysms were packed with collagen sponges per-operatively in 25 animals. Angiography, serial histological studies and immuno-histochemistry tests were used to study healing phenomena and measure neointima formation at various time intervals from 1 day to 9 weeks after surgery. GDC embolization was performed in 5 other pigs for comparison with the collagen sponge model. Explants from the neointima at the neck of aneurysms as well as from the parent artery of 8 pigs were prepared in an attempt to grow and to characterize in vitro cells responsible for healing porcine aneurysms using immunocytochemistry and enzymatic assays. To confirm the hypothesis that an analogy exists between cells involved in aneurysmal healing and neointimal cells found in restenosis, explant outgrowths were scored and compared to explants from intact carotid arteries and carotid arteries subjected to angioplasty in 3 other animals. In addition, to test the value of neointima measurements in quantifying results, 6 dogs were analysed to correlate the thickness of the neointima formed at the neck of aneurysms with angiographic results in animals prone to recurrences. RESULTS: Histopathological findings with collagen sponge packing were similar to the ones following coil embolization. Porcine aneurysms had a strong tendency to heal with a thick neointima primarily composed of vascular smooth muscle cells (VSMCs). Aneurysms in dogs did not heal as well and the neointima at the neck of treated lesions was thin. Cells responsible for healing of experimental porcine aneurysms could be cultured in vitro, and are activated VSMCs. These cells, similar to those harvested following balloon injury, had a higher colony forming capacity and an accelerated explant outgrowth rate as compared to cells derived from the parent artery. CONCLUSION: Animals which heal poorly harbor a thin or deficient neointima at the neck of treated aneurysms. Favorable healing in porcine aneurysms involves VSMCs which form a thick neointima. These VSMCs can be cultured in vitro. They share similar outgrowth characteristics with VSMCs recovered after balloon angioplasty. The collagen sponge model may be useful to harvest cells for in vitro experimentation and in the in vivo evaluation of the local delivery of potential therapeutic molecules thought to improve healing following embolization of aneurysms.


Subject(s)
Aneurysm/pathology , Carotid Artery Diseases/pathology , Muscle, Smooth, Vascular/pathology , Tunica Intima/pathology , Wound Healing/physiology , Aneurysm/physiopathology , Animals , Carotid Artery Diseases/physiopathology , Dogs , Swine
13.
AJR Am J Roentgenol ; 172(1): 207-12, 1999 Jan.
Article in English | MEDLINE | ID: mdl-9888769

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the value of the ratio between the internal carotid systolic velocity (ICSV) at the carotid bulb and the distal internal carotid systolic velocity (DICSV) for the detection of carotid artery stenosis. SUBJECTS AND METHODS: Two hundred eleven patients were enrolled in a prospective study comparing several Doppler measurements with carotid angiography. The following spectral measurements were obtained with Doppler sonography: ICSV/DICSV ratio, ICSV, ICSV/common carotid systolic velocity (CCSV) ratio, and internal carotid (end) diastolic velocity (ICDV). Receiver operating characteristic curves were generated for two groups: the first group being 365 carotid arteries for which all Doppler measurements were successfully obtained and the second being a subgroup of 258 carotid arteries for which an ICSV of 100 cm/sec or greater was present. RESULTS: In the group of 365 carotid arteries, the ICSV/DICSV ratio improved the detection of stenosis of 60% or greater as compared with the ICDV (p = .03). In 258 carotid arteries with an ICSV of 100 cm/sec or greater, the ICSV/DICSV ratio allowed for a better angiographic correlation for identifying stenoses of 60% or greater and 70% or greater as compared with ICSV (p = .006 and .023, respectively), ICSV/CCSV (p = .0013 and .003, respectively), and ICDV (p = .0015 and .020, respectively). CONCLUSION: Using the ICSV/DICSV ratio for the Doppler detection of carotid artery stenosis is advantageous when the ICSV is 100 cm/sec or greater.


Subject(s)
Blood Flow Velocity , Carotid Stenosis/diagnostic imaging , Ultrasonography, Doppler , Aged , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/physiopathology , Carotid Stenosis/physiopathology , Cerebral Angiography , Humans , Male , Observer Variation , Prospective Studies , ROC Curve , Sensitivity and Specificity
14.
Radiology ; 209(2): 357-63, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9807559

ABSTRACT

PURPOSE: To evaluate the safety and long-term clinical and hemodynamic results of percutaneous transluminal angioplasty (PTA) of the infrarenal aorta. MATERIALS AND METHODS: During nearly 10 years, 102 patients with symptomatic infrarenal atherosclerotic aortic stenosis underwent PTA. Follow-up information was available in 92 patients (17 men, 75 women; mean age, 51.9 years). Stenosis involved the aortic bifurcation in 18 patients and only the infrarenal abdominal aorta in 74 patients. Technical success was defined as residual stenosis less than 50% or a pressure gradient less than 10 mm Hg after PTA. Clinical patency was defined as the absence or improvement of symptoms after PTA. Hemodynamic patency was defined as a normal Doppler waveform in the common femoral arteries, an ankle-brachial ratio greater than 0.95, or the absence of a thigh-brachial pressure gradient. RESULTS: Technical success was achieved in 78 patients after PTA. After 10 years, primary clinical and hemodynamic patency rates were 72% and 46%, respectively. After a mean follow-up of 51 months, 15 of the 22 symptomatic recurrences were due to aortic restenosis; 11 of these were treated with repeated PTA with or without stent placement, and three eventually required aortic surgery. No morbidity was encountered. CONCLUSION: Infrarenal aortic PTA proved to be safe and provided durable, long-term clinical improvement. In this group of relatively young patients, the clinical patency rate of PTA was equivalent to that of aortic surgery but with less morbidity.


Subject(s)
Angioplasty, Balloon , Aortic Diseases/therapy , Arteriosclerosis/therapy , Aorta, Abdominal , Aortic Diseases/physiopathology , Arteriosclerosis/physiopathology , Constriction, Pathologic/physiopathology , Constriction, Pathologic/therapy , Female , Follow-Up Studies , Humans , Male , Middle Aged , Recurrence , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
15.
AJR Am J Roentgenol ; 171(1): 119-24, 1998 Jul.
Article in English | MEDLINE | ID: mdl-9648774

ABSTRACT

OBJECTIVE: The goal of this study was to compare patients with aortic graft infection treated by primary percutaneous drainage with patients who initially underwent surgery. MATERIALS AND METHODS: A retrospective review of 23 consecutive patients treated for aortic graft infection was performed. Eleven patients were initially treated with percutaneous drainage and 12 were treated with surgery. The morbidity, mortality, and postprocedural reintervention rates and clinical outcome were analyzed for each group. RESULTS: The septic process resolved in nine (82%) of 11 patients treated with percutaneous drainage. Of these nine patients, four were treated with percutaneous drainage alone. Drainage was followed by removal of the infected prosthetic graft in the remaining five patients. In the surgical group, sepsis resolved in only four patients (33%) (p = .036). No periprocedural deaths occurred in the percutaneous drainage group, whereas six patients in the surgical group died in the perioperative period (p = .014). CONCLUSION: Percutaneous drainage can be used as an initial form of treatment in the management of aortic graft infections. Surgery after percutaneous drainage appears to be safer than surgery alone.


Subject(s)
Blood Vessel Prosthesis/adverse effects , Drainage/methods , Prosthesis-Related Infections/therapy , Aged , Anti-Bacterial Agents , Aorta, Abdominal/surgery , Aortic Diseases/surgery , Case-Control Studies , Drug Therapy, Combination/therapeutic use , Female , Humans , Male , Polyethylene Terephthalates , Prosthesis-Related Infections/mortality , Retrospective Studies , Treatment Outcome
16.
Radiology ; 207(3): 695-703, 1998 Jun.
Article in English | MEDLINE | ID: mdl-9609892

ABSTRACT

PURPOSE: To compare nonstepping digital subtraction angiography (DSA) (ie, storage phosphor radiography adapted to a stationary imaging plate changer) with conventional screen-film angiography in the evaluation of the lower extremities. MATERIALS AND METHODS: Fifty-one patients with peripheral vascular disease underwent both nonstepping DSA and screen-film angiography. The angiographic and radiologic techniques of both systems were kept identical for each patient. Three radiologists independently rated the overall quality of each angiogram. In their evaluations for each of 12 arterial segments on all 102 angiograms, they also rated the degree of opacification, the diameter reduction of the most severe stenosis, and their level of confidence. RESULTS: Mean overall quality scores and levels of confidence were better for nonstepping DSA than for screen-film angiography (P < .001). Full opacification was reported in 95.6% and 89.2% of all 1,836 segments with nonstepping DSA and screen-film angiography, respectively (P < .0001). The difference between the mean stenosis grades obtained with screen-film angiography and nonstepping DSA was not statistically significant. Intertechnique agreements were good (kappa = 0.77, 0.81, and 0.81), whereas interobserver agreements were influenced by the observer's experience with the imaging techniques. CONCLUSION: Nonstepping DSA images of the lower extremity were of better diagnostic quality than were screen-film angiograms. The development of dedicated nonstepping DSA equipment is warranted.


Subject(s)
Angiography, Digital Subtraction/methods , Angiography/methods , Leg/diagnostic imaging , Adult , Aged , Aged, 80 and over , Analysis of Variance , Angiography/instrumentation , Angiography/statistics & numerical data , Angiography, Digital Subtraction/instrumentation , Angiography, Digital Subtraction/statistics & numerical data , Contrast Media , Female , Humans , Male , Middle Aged , Observer Variation , Peripheral Vascular Diseases/diagnostic imaging , Software , X-Ray Intensifying Screens
18.
AJR Am J Roentgenol ; 170(1): 169-75, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9423626

ABSTRACT

OBJECTIVE: The goal of this study was to assess the value of quantitative and qualitative analysis of the early systolic rise on Doppler waveforms obtained before and after administration of captopril in patients suspected of having renal artery stenosis. SUBJECTS AND METHODS: Seventy-one hypertensive patients (135 kidneys) were studied with transrenal Doppler sonography. Ninety-six kidneys were studied again after administration of captopril. All patients also underwent renal angiography. All Doppler studies were independently reviewed by two observers. Specific criteria for Doppler waveform patterns that were applied in the detection of renal artery stenosis included acceleration, acceleration time of early systolic rise, differential velocity of systolic rise, and resistive index. These criteria were then correlated with angiography, and receiver operating characteristic curves were generated. RESULTS: On the basis of waveform pattern recognition. Doppler sonograms obtained before administration of captopril had a sensitivity of 81% and a specificity of 98% for the detection of renal artery stenosis greater than or equal to 50%. Sensitivity of Doppler sonography obtained after administration of captopril was 100%, and specificity was 100%. For renal artery stenosis greater than or equal to 70%, sensitivity was 94% and specificity was 89% before administration of captopril. The area under the receiver operating characteristic curve for the acceleration criterion was significantly larger after administration of captopril (p = .009) for the detection of renal artery stenosis greater than or equal to 50%. After captopril administration, an acceleration threshold value of 440 cm/sec2 for early systolic rise was associated with a sensitivity of 100% and a specificity of 94% for the detection of renal artery stenosis greater than or equal to 50%. CONCLUSION: Doppler sonography of the renal arteries performed before administration of captopril appears to be an excellent screening tool in the detection of severe stenosis (> or = 70%). Administration of captopril improves the detection of renal artery stenosis greater than or equal to 50% with Doppler sonography when observers use both morphologic and quantitative criteria.


Subject(s)
Antihypertensive Agents , Captopril , Renal Artery Obstruction/diagnostic imaging , Ultrasonography, Doppler/methods , Case-Control Studies , Female , Humans , Hypertension, Renovascular/diagnostic imaging , Male , Middle Aged , ROC Curve , Renal Artery/diagnostic imaging , Renal Artery/physiopathology , Sensitivity and Specificity , Systole/physiology
19.
Radiology ; 205(3): 663-8, 1997 Dec.
Article in English | MEDLINE | ID: mdl-9393518

ABSTRACT

PURPOSE: To determine the analgesic efficacy and safety of interpleural block for percutaneous biliary drainage. MATERIALS AND METHODS: In this double-blind study, 34 age- and sex-matched patients who were to undergo percutaneous biliary drainage because of malignant biliary obstruction were randomly assigned to the true-block group (30 mL 0.5% bupivacaine block) or placebo-block group; all had access to a patient-controlled analgesia (fentanyl) pump. Self medication, pain reports, blood pressure, heart rate, and oxygen saturation were monitored during and until 8 hours after drainage. The McGill Pain Questionnaire was administered 1 hour after biliary drainage. RESULTS: Patients in the placebo group self administered statistically significantly more fentanyl than did patients in the true-block group (P = .008). Peak pain scores (10-point scale) and McGill Pain Questionnaire scores were statistically significantly higher for the placebo group patients (P = .017 and P = .001, respectively). There were no differences between groups in terms of blood pressure, heart rate, and oxygen saturation. Two patients had pneumothorax caused by the interpleural block. CONCLUSION: Interpleural block was effective in decreasing pain and opioid requirements during and after percutaneous biliary drainage and did not compromise the cardiopulmonary status of the patient. However, the rate of pneumothorax was higher than previously reported.


Subject(s)
Analgesia , Anesthetics, Local , Bupivacaine , Cholestasis/therapy , Drainage/methods , Nerve Block , Aged , Analgesia/adverse effects , Analgesia/methods , Analgesia, Patient-Controlled , Analgesics, Opioid , Double-Blind Method , Female , Fentanyl , Humans , Male , Nerve Block/adverse effects , Nerve Block/methods , Pain Measurement , Pleura , Pneumothorax/etiology
20.
Radiology ; 204(3): 780-6, 1997 Sep.
Article in English | MEDLINE | ID: mdl-9280259

ABSTRACT

PURPOSE: To evaluate the long-term results of peripheral biliary diversion by means of anastomoses of the left lobe of the liver to the stomach. MATERIALS AND METHODS: Transhepatic perforation of the left lobe of the liver into the lesser curvature of the stomach was performed in 35 patients with a presumed diagnosis of malignant obstructive jaundice. Jaundice was found to be caused by a malignant stricture in 32 patients and a benign stricture in three. Perforation was performed under fluoroscopic, endoscopic, and laparoscopic guidance in 33 patients and without laparoscopy in the other two. The hepaticogastric anastomosis was secured with a gastrostomy tube; patency of the tract was maintained with placement of a metallic stent. Kaplan-Meier analysis was used to evaluate survival, anastomosis patency rate, and jaundice recurrence. RESULTS: Technical success was achieved in all patients. Two (6%) patients had anastomotic obstruction. The actuarial survival rate was 91%, 80%, 59%, and 26% at 1, 3, 6, and 12 months. The mean patency was 234 days +/- 252. The jaundice-free rate among surviving patients was 100%, 96%, 93%, and 80% at 1, 3, 6, and 12 months. The reintervention rate was 14%. Late cholangitis occurred in seven (20%) patients. CONCLUSION: This peripheral diversion procedure appears to be safe and shows good long-term patency.


Subject(s)
Cholestasis/surgery , Liver/surgery , Stomach/surgery , Adult , Aged , Aged, 80 and over , Anastomosis, Surgical , Bile Ducts, Intrahepatic/surgery , Biliary Tract Neoplasms/complications , Cholangiography , Cholestasis/diagnostic imaging , Cholestasis/etiology , Female , Humans , Male , Middle Aged , Palliative Care , Postoperative Complications , Stents , Surgical Procedures, Operative/methods
SELECTION OF CITATIONS
SEARCH DETAIL