Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 81
Filter
1.
Braz Dent J ; 35: e245632, 2024.
Article in English | MEDLINE | ID: mdl-38537016

ABSTRACT

This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.


Subject(s)
Dental Implants , Humans , Dental Prosthesis Design , Mouth , Face , Torque , Dental Implantation, Endosseous/methods
2.
Clin Oral Implants Res ; 35(4): 359-376, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38315151

ABSTRACT

BACKGROUND: The aim of this systematic review and network meta-analysis (NMA) was to assess the efficacy of different wound-healing agents for palatal donor area management after soft tissue graft harvesting. METHODS: Electronic searches in six databases were conducted for publications up to October 2023. Studies with data from patients undergoing therapeutic approaches using agents for palatal healing after gingival graft harvesting were included. Data about postoperative pain, wound-healing and postoperative complications reported for each agent were extracted. Three different tools were used for the risk of bias within studies evaluation (Murad tool for case series and case report, RoB 2.0 tool for randomized studies and ROBINS-I tool for non-randomized studies). A Bayesian random effects NMA was conducted for postoperative pain levels and wound healing. RESULTS: Eighty-four publications were included in the systematic review (qualitative analysis), with 14 of these subjected to NMA (quantitative analysis). The summarized results from the qualitative and quantitative analysis showed that all wound-healing agents evaluated promoted better pain control and wound healing compared to spontaneous healing and hemostatic sponges alone. The NMA outcomes reveal that leucocyte- and platelet-rich fibrin (L-PRF) was the most effective agent in reducing postoperative pain in all analyzed periods. Moreover, the L-PRF seems to accelerate wound healing and reduce postoperative complications compared to other agents. CONCLUSION: In conclusion, the L-PRF was the most effective agent in reducing postoperative pain, accelerating wound healing and reducing postoperative complications after harvesting soft tissue grafts from the palatal area.


Subject(s)
Postoperative Complications , Wound Healing , Humans , Bayes Theorem , Network Meta-Analysis , Pain, Postoperative/drug therapy
3.
Braz. j. oral sci ; 23: e243937, 2024. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1555183

ABSTRACT

Aim: This study was performed to compare two different rat defect models (critical calvaria defects versus guided bone regeneration in the mandibular ramus) used to evaluate bone repair in grafted areas. Methods: A total of 12 rats were allocated in two groups according the experimental model used to evaluate the bone repair in grafted areas: a critical sized-calvaria defect of 5 mm filled with bone graft (n=6) and a mandibular ramus filled with the bone graft associated with a Teflon dome-shaped membrane (n=6). Both groups were grafted with deproteinized bovine bone graft. After 60 days, the animals were euthanized and the samples obtained were submitted to histomorphometry analysis to evaluate the relative amount of bone, remaining bone substitute, and soft tissue within the grafted areas. Results: No differences were observed between the preclinical models evaluated in relation to the amount of bone tissue formation (19.93 ± 4.55% in calvaria vs. 21.00 ± 8.20% in mandible). However, there was a smaller amount of soft tissue (43.20 ± 10.97% vs. 57.79 ± 7.61 %; p<0.01) and a greater amount of bone substitute remaining (35.80 ± 5.52% vs. 22.28 ± 4.36 %; p<0.05) in the grafted areas in the mandible compared to calvaria defect. Conclusion: Preclinical models for the analysis of bone repair in grafted areas in the mandible and critical sized-calvaria defects showed different responses in relation to the amount of soft tissue and bone substitute remnants


Subject(s)
Animals , Rats , Bone Regeneration , Bone Substitutes , Animal Experimentation , Histology
4.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1550093

ABSTRACT

Abstract This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.


Resumo O objetivo deste estudo controlado randomizado de boca dividida foi avaliar a estabilidade primária e secundária de implantes híbridos com diferentes configurações de rosca e superfícies hidrofílicas. Vinte pacientes com maxila parcialmente edêntula foram selecionados. Esses pacientes receberam dois tipos de implantes com a mesma superfície hidrofílica: Grupo CTP: Implante cilíndrico-cônico com roscas perfurantes; Grupo CTH: Implante cilíndrico-cônico com roscas perfurantes e condensadoras. Os parâmetros de estabilidade primária e secundária foram medidos por análise de torque de inserção e frequência de ressonância no momento da colocação do implante e 7, 28, 56 e 90 dias após o procedimento cirúrgico. O teste t-pareado foi utilizado para comparação dos dados de estabilidade entre os grupos. A análise estatística foi executada levando-se em consideração um nível de confiança de 95%. Constatou-se que os implantes do grupo CTH apresentaram maiores valores de estabilidade primária no momento da colocação do implante, devido ao maior ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) e torque de inserção (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), do que os implantes do grupo CTP. Implantes do grupo CTH apresentaram valores de ISQ superiores em todos os períodos de acompanhamento: 7 dias (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 dias (68.61 ± 5.98 vs. 47.90 ±13.10), 56 dias (74.09 ± 3.96 vs. 55.85 ± 13.18) e 90 dias (75.45 ± 4.02 vs. 63.47 ± 6.92). Os implantes híbridos com roscas perfurantes e condensantes demonstraram maior estabilidade do que os implantes híbridos com apenas roscas perfurantes.

5.
Braz Dent J ; 34(5): 43-52, 2023.
Article in English | MEDLINE | ID: mdl-38133472

ABSTRACT

This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.


Subject(s)
Dental Implants , Diabetes Mellitus , Rats , Animals , Osseointegration , Fluorides , Tibia , Titanium , Surface Properties , Torque
6.
Braz. dent. j ; 34(5): 43-52, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1528014

ABSTRACT

Abstract This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.


Resumo Este estudo avaliou a influência de uma superfície de titânio modificada com flúor na osseointegração em ratos com diabetes induzida. Cento e oitenta ratos foram distribuídos aleatoriamente em 3 grupos com 60 animais cada: Grupo controle (C): Animais sem diabetes; Grupo Diabetes (D): Animais com diabetes induzida descompensada; Grupo Diabetes Controlado (CD): Animais com diabetes induzido controlado pela administração de insulina. O diabetes foi induzido por injeção de estreptozotocina. Cada animal recebeu 2 implantes na metáfise proximal da tíbia, um com superfície usinada (M) e outro com superfície de titânio modificado com flúor (F), após 4 semanas de indução do diabetes. Os animais foram submetidos à eutanásia 2, 4 e 6 semanas após a colocação do implante (n = 20 animais/grupo). A osseointegração foi avaliada pelo teste de torque de remoção do implante e pela análise histométrica dos cortes histológicos não descalcificados: 1) Contato osso-implante (%BIC); 2) Área de tecido ósseo entre as roscas do implante (%BBT). Os implantes com superfície F apresentaram maior torque de remoção do que os implantes com superfície M em todos os grupos. Não houve diferença no %BIC entre os grupos independente da superfície utilizada. A superfície F mostrou tendência a apresentar maiores valores de %BBT para os 3 períodos de avaliação no grupo D. As superfícies de implantes modificadas com flúor não influenciaram nos dados de %BIC e %BBT. Entretanto, essas superfícies aumentaram o travamento dos implantes no tecido ósseo. A hiperglicemia foi associada a menores torques de remoção dos implantes independentemente do tipo de superfície de implante utilizada.

7.
Healthcare (Basel) ; 11(18)2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37761669

ABSTRACT

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant's position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.

8.
Braz Dent J ; 34(3): 66-72, 2023.
Article in English | MEDLINE | ID: mdl-37466527

ABSTRACT

The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of non-decalcified histological sections and evaluation of the bone implant contact (% BIC) as well as the fraction of bone tissue area between the implant threads (% BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) and % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.


Subject(s)
Dental Implants , Osseointegration , Animals , Rabbits , Surface Properties , Hydrophobic and Hydrophilic Interactions , Bone and Bones , Titanium , Torque
9.
Braz. dent. j ; 34(3): 66-72, May-June 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1447593

ABSTRACT

Abstract The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of non-decalcified histological sections and evaluation of the bone implant contact (% BIC) as well as the fraction of bone tissue area between the implant threads (% BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) and % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.


Resumo O objetivo deste estudo foi avaliar a osseointegração de uma superfície hidrofílica (jateamento + ataque ácido + imersão em solução isotônica) em comparação com uma superfície controle (jateamento + ataque ácido) usando um modelo experimental de osso de baixa densidade. Para realizar o estudo, 24 coelhos foram submetidos a instalação de 4 implantes bilateralmente no osso ilíaco: 2 implantes com superfície controle e 2 implantes com superfície hidrofílica. Os coelhos foram eutanasiados com 2, 4 e 8 semanas após a instalação dos implantes. Após a eutanásia, um implante de cada superfície foi usado para avaliar o torque de remoção, e o outro implante foi utilizado para execução de cortes histológicos não descalcificados e avaliação de contato osso implante (% BIC) bem como a fração da área tecido ósseo entre as roscas do implante (% BBT). Os implantes com superfície hidrofílica apresentaram maior %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) e % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) no período de 2 semanas. Além disso, a superfície hidrofílica apresentou maior torque de remoção no período de 8 semana (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implantes com a superfície hidrofílica apresentaram aceleração no processo de osseointregração, culminando em melhor estabilidade secundária no osso de baixa densidade em relação a implantes com superfície controle.

10.
Braz Oral Res ; 37: e048, 2023.
Article in English | MEDLINE | ID: mdl-37255068

ABSTRACT

This study evaluated the effect of photobiomodulation therapy (PBMT) with a red or infrared laser on the repair of post extraction sockets in rats administered alendronate (ALN). Forty male rats were randomly allocated into four groups: Control Group (CTR): subcutaneous administration of saline solution throughout the experimental period; Alendronate Group (ALN): subcutaneous administration of alendronate during the entire experimental period; Alendronate/Red Laser Group (ALN/RL): administration of ALN and irradiation with a GaAlAs laser (λ 660 nm); and Alendronate/Infrared Laser Group (ALN/IRL): administration of ALN and irradiation with a GaAlAs laser (λ 830 nm). The first lower molars were extracted 60 days after the beginning of the administration of the drugs. The PBMT was applied after tooth extraction (7 sessions with intervals of 48 hours between sessions). Thirty days after tooth extraction, the animals were euthanized. Micro-CT and histometric analysis were performed to assess the bone healing and soft tissue repair of the tooth socket. The ALN group presented with more bone than the CTR; however, most of this bone was necrotic. ALN does not affect the bone microarchitecture. On the other hand, PBMT with IRL enhances the bone density due to the increase in the number and reduction in the spacing of the trabeculae. The amount of vital bone and connective tissue matrix was higher in the ALN/RL and ALN/IRL groups than in the ALN and CTR groups. PBMT enhanced the healing of the post extraction sockets in rats subjected to ALN administration. Furthermore, IRL improved the new bone microarchitecture.


Subject(s)
Alendronate , Bone Density Conservation Agents , Humans , Rats , Male , Animals , Alendronate/pharmacology , Alendronate/therapeutic use , Wound Healing , Bone Density Conservation Agents/pharmacology , Bone Density Conservation Agents/therapeutic use , Dental Care , Lasers, Semiconductor/therapeutic use
11.
Braz Dent J ; 34(2): 105-112, 2023.
Article in English | MEDLINE | ID: mdl-37194848

ABSTRACT

This study aimed to evaluate the effect of nicotine administration on the osseointegration of a superhydrophilic implants surface on rat tibiae. Thirty-two rats were used and divided into 2 groups according to the administration or not of nicotine: HH - Installation of implants with superhydrophilic surfaces in healthy animals; and HN - Installation of implants with superhydrophilic surfaces in animals subjected to nicotine administration. The animals were euthanized 15 and 45 days after implant placement (n = 8). Osseointegration was assessed by means of biomechanical analyses (removal torque), microcomputed tomography (volume of bone around the implants- %BV/TV), and histomorphometry (bone-implant contact -%BIC and the bone area between implant threads -%BBT). The animals subject to the nicotine administration presented lower removal torque than the control animals at the 45-day period (21.88 ± 2.80 Ncm vs. 17.88 ± 2.10 Ncm). The implants placed in the control rats presented higher %BIC (54.26 ± 6.59% vs. 39.25 ± 4.46%) and %BBT (50.57 ± 5.28% vs. 32.25 ± 5.24%) than the implants placed in nicotine animals at 15-day period. The nicotine administration reduces the osseointegration at 15 days, however, the superhydrophilic surface equalized the osseointegration in nicotine-exposed animals compared with healthy animals after 45 days of implant placement.


Subject(s)
Dental Implants , Nicotine , Rats , Animals , Nicotine/pharmacology , Osseointegration , X-Ray Microtomography , Tibia , Titanium/pharmacology , Torque , Surface Properties
12.
Braz. dent. j ; 34(2): 105-112, Mar.-Apr. 2023. graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1439575

ABSTRACT

Abstract This study aimed to evaluate the effect of nicotine administration on the osseointegration of a superhydrophilic implants surface on rat tibiae. Thirty-two rats were used and divided into 2 groups according to the administration or not of nicotine: HH - Installation of implants with superhydrophilic surfaces in healthy animals; and HN - Installation of implants with superhydrophilic surfaces in animals subjected to nicotine administration. The animals were euthanized 15 and 45 days after implant placement (n = 8). Osseointegration was assessed by means of biomechanical analyses (removal torque), microcomputed tomography (volume of bone around the implants- %BV/TV), and histomorphometry (bone-implant contact -%BIC and the bone area between implant threads -%BBT). The animals subject to the nicotine administration presented lower removal torque than the control animals at the 45-day period (21.88 ± 2.80 Ncm vs. 17.88 ± 2.10 Ncm). The implants placed in the control rats presented higher %BIC (54.26 ± 6.59% vs. 39.25 ± 4.46%) and %BBT (50.57 ± 5.28% vs. 32.25 ± 5.24%) than the implants placed in nicotine animals at 15-day period. The nicotine administration reduces the osseointegration at 15 days, however, the superhydrophilic surface equalized the osseointegration in nicotine-exposed animals compared with healthy animals after 45 days of implant placement.


Resumo O objetivo deste estudo foi avaliar o efeito da administração de nicotina na osseointegração de implantes com superfície modificada por jateamento de oxidos e ataque ácido instalados em tíbia de ratos. Foram utilizados 32 ratos que foram divididos em 2 grupos de acordo com a administração ou não de nicotina: HH - Instalação de implantes com superfícies superhidrofílicas em animais sadios; e HN - Instalação de implantes com superfícies superhidrofílicas em animais submetidos à administração de nicotina. Os animais foram eutanasiados 15 e 45 dias após a colocação do implante (n = 8). A osseointegração foi avaliada por meio de análises biomecânicas (torque de remoção), microtomografia (volume de osso ao redor dos implantes - %BV/TV) e histomorfometrica (contato osso-implante -%BIC e área óssea entre roscas do implante -%BBT). Os animais submetidos à administração de nicotina apresentaram menor torque de remoção do que os animais controle no período de 45 dias (21,88 ± 2,80 Ncm vs. 17,88 ± 2,10 Ncm). Os implantes colocados nos ratos controle apresentaram maiores %BIC (54,26 ± 6,59% vs. 39,25 ± 4,46%) e %BBT (50,57 ± 5,28% vs. 32,25 ± 5,24%) do que os implantes colocados nos animais submetidos a administração de nicotina no período de 15 dias. A administração de nicotina prejudicou a osseointegração no período de 15 dias. Entretanto, a superfície superhidrofílica equalizou a osseointegração em animais expostos à nicotina em comparação com animais saudáveis após 45 dias da colocação do implante.

13.
Braz. oral res. (Online) ; 37: e048, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1439748

ABSTRACT

Abstract This study evaluated the effect of photobiomodulation therapy (PBMT) with a red or infrared laser on the repair of post extraction sockets in rats administered alendronate (ALN). Forty male rats were randomly allocated into four groups: Control Group (CTR): subcutaneous administration of saline solution throughout the experimental period; Alendronate Group (ALN): subcutaneous administration of alendronate during the entire experimental period; Alendronate/Red Laser Group (ALN/RL): administration of ALN and irradiation with a GaAlAs laser (λ 660 nm); and Alendronate/Infrared Laser Group (ALN/IRL): administration of ALN and irradiation with a GaAlAs laser (λ 830 nm). The first lower molars were extracted 60 days after the beginning of the administration of the drugs. The PBMT was applied after tooth extraction (7 sessions with intervals of 48 hours between sessions). Thirty days after tooth extraction, the animals were euthanized. Micro-CT and histometric analysis were performed to assess the bone healing and soft tissue repair of the tooth socket. The ALN group presented with more bone than the CTR; however, most of this bone was necrotic. ALN does not affect the bone microarchitecture. On the other hand, PBMT with IRL enhances the bone density due to the increase in the number and reduction in the spacing of the trabeculae. The amount of vital bone and connective tissue matrix was higher in the ALN/RL and ALN/IRL groups than in the ALN and CTR groups. PBMT enhanced the healing of the post extraction sockets in rats subjected to ALN administration. Furthermore, IRL improved the new bone microarchitecture.

14.
Braz Dent J ; 33(6): 71-77, 2022.
Article in English | MEDLINE | ID: mdl-36477967

ABSTRACT

The purpose of this study was to evaluate the effect of a surface modified by blasting and acid attack and maintained in an isotonic solution compared to a machined surface on osseointegration in normo- and hyperglycaemic animals. Sixty-four animals were allocated into 4 groups with 16 animals each, and they were subdivided into two experimental periods (15 and 45 days), with 8 animals in each group. The groups were divided according to the type of implant that was installed in the animals' tibia and the animals' systemic condition: CM - Machined implants placed in Healthy animals; CH - Hydrophilic implants placed in Healthy animals, HM - Machined implants placed in animals with hyperglycaemia; HH- Hydrophilic implants installed in animals with hyperglycaemia. The following analyses were performed: biomechanical (removal torque), microtomographic (evaluation of the bone volume around the implants- BV/TV), and histomorphometric (evaluation of bone-implant contact BIC% and of the bone formation area between the threads BBT%). It was found that the implants with hydrophilic surfaces presented higher removal torques and quantities of BV/TV% and higher BIC% and BBT% values in normo- and hyperglycaemic animals. The results of this study indicated that the hydrophilic surface accelerates the osseointegration process (~ 15% BIC/BBT at 15-day period), especially in animals with hyperglycaemia. The hydrophilic surface equaled the osseointegration between normo- and hyperglycaemic animals, reversing the negative potential of hyperglycaemia on the osseointegration process.


Subject(s)
Hyperglycemia , Rats , Animals
15.
Braz. dent. j ; 33(6): 71-77, Nov.-Dec. 2022. tab
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1420555

ABSTRACT

Abstract The purpose of this study was to evaluate the effect of a surface modified by blasting and acid attack and maintained in an isotonic solution compared to a machined surface on osseointegration in normo- and hyperglycaemic animals. Sixty-four animals were allocated into 4 groups with 16 animals each, and they were subdivided into two experimental periods (15 and 45 days), with 8 animals in each group. The groups were divided according to the type of implant that was installed in the animals' tibia and the animals' systemic condition: CM - Machined implants placed in Healthy animals; CH - Hydrophilic implants placed in Healthy animals, HM - Machined implants placed in animals with hyperglycaemia; HH- Hydrophilic implants installed in animals with hyperglycaemia. The following analyses were performed: biomechanical (removal torque), microtomographic (evaluation of the bone volume around the implants- BV/TV), and histomorphometric (evaluation of bone-implant contact BIC% and of the bone formation area between the threads BBT%). It was found that the implants with hydrophilic surfaces presented higher removal torques and quantities of BV/TV% and higher BIC% and BBT% values in normo- and hyperglycaemic animals. The results of this study indicated that the hydrophilic surface accelerates the osseointegration process (~ 15% BIC/BBT at 15-day period), especially in animals with hyperglycaemia. The hydrophilic surface equaled the osseointegration between normo- and hyperglycaemic animals, reversing the negative potential of hyperglycaemia on the osseointegration process.


Resumo O objetivo deste foi o de avaliar o efeito de uma superfície modificada por jateamento e ataque ácido e mantida em solução isotônica em comparação a uma superfície lisa sobre a osseointegração de implantes em animais hiperglicêmicos. No estudo foram utilizados 64 ratos, que foram divididos em 4 grupos com 16 animais em cada, e que foram avaliados em dois períodos experimentais (15 e 45 dias), com 8 animais em cada grupo. Os grupos foram divididos de acordo com o tipo de implante que foi instalado na tíbia dos animais e a condição sistêmica dos mesmos: Grupo CM - Implantes maquinados instalados em animais saudáveis; Grupo CH - Implantes maquinados instalados em animais com hiperglicemia; Grupo HM - Implantes hidrofílicos instalados em animais saudáveis, Grupo HH- Implantes hidrofílicos instalados em animais com hiperglicemia. Foram realizadas análises: biomecânicas (contra torque de remoção dos implantes), histométricas (avaliação do contato do osso com os implantes e da área de formação óssea entre as roscas) e microtomográfica (avaliação da área óssea ao redor dos implantes). Foi verificado que os implantes com superfície hidrofílica apresentaram maiores torques de remoção, quantidade de osso ao redor dos implantes e maiores valores de %BIC e %BBT em animais normo e hiperglicêmicos. Conclui-se que a superfície hidrofílica acelera o processo de osseointegração (~15% de %BIC/%BBT aos 15 dias), especialmente em animais com hiperglicêmicos. A superfície hidrofílica igualou a osseointegração entre animais normo- e hiperglicêmicos, revertendo o potencial negativo da hiperglicemia no processo de osseointegração.

16.
Braz. j. oral sci ; 21: e220616, jan.-dez. 2022. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1393329

ABSTRACT

The use of selective barriers as resorbable membranes has become a routine clinical procedure for guided bone regeneration. Therefore, the production of membranes with a low inflammatory potential during their resorption process has become the goal of a considerable number of researches. Aim: The purpose of the present study was to evaluate the biocompatibility of poly (L- lactic acid) (PLLA) and biocelulose membranes (BC) inserted in the subcutaneous tissue on the dorsum of rats. Methods: Fifteen animals underwent surgical procedures for the insertion of 4 types of membranes: COL (Collagen membrane) ­ Control Group; BC (Biocellulose membrane); BCAg (Biocellulose membrane impregnated with Silver); PLLA (Poly (L-lactic acid) membrane). All membrane types were inserted into each animal. Animals were euthanized after 3, 7, and 15 days of the surgical procedure. Descriptive histological analyses were carried out to investigate host tissue reaction to membrane presence by assessing the anti-inflammatory process composition associated with the membrane resorption and the presence of foreign-body reaction or encapsulation. Results: The BC membranes showed a higher degree of inflammation and poor pattern of integration with the surrounding tissues than the PLLA and COL membranes. Conclusion: The PLLA and COL membranes present better biocompatibility than the BC membranes


Subject(s)
Animals , Rats , Biocompatible Materials/analysis , Bone Regeneration , Materials Testing , Lactic Acid , Subcutaneous Tissue , Membranes , Cellulose , Inflammation
17.
Braz Dent J ; 33(4): 40-46, 2022.
Article in English | MEDLINE | ID: mdl-36043567

ABSTRACT

The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure the length of the NB and GB. Furthermore, the amount of mineralized tissues at the NB and GB was performed. In the histomorphometry analysis the percentage of mineralized tissues at the NB and GB was obtained in two histological sections while the mineralized tissues were measure in the micro-CT varying the thresholds of the grayscale varying from 90-250 to 90-150 with 10 levels of variation between each one was applied. Then these data were correlated in order to check the higher r level between the histomorphometry and micro-CT thresholds intervals. The linear length of the NB was 2.44±0.91mm and 2.48±1.50mm, respectively, for micro-CT and histomorphometry (r =0.57), while the linear length of the GB was 3.63±1.66mm and 3.13±1.45mm, respectively, for micro-CT and histomorphometry (r =0.74) Histomorphometry showed 45.91±11.69% of bone in NB, and 49.57±5.59% of bone and biomaterial in the GB. The total volume of mineralized tissues that were closest to the histometric analysis were 43.75±15.39% in the NB (Threshold:90-240; r = 0.50) and 51.68±8.42% in the GB (Threshold:90-180; r =-0.028). The micro-CT analysis showed good accuracy in the linear analysis in both portions of the biopsies but for volumetric analysis just in NB.


Subject(s)
Bone Substitutes , Bone and Bones , Animals , Biocompatible Materials , Cattle , Humans , Maxillary Sinus , X-Ray Microtomography
18.
Braz. dent. j ; 33(4): 40-46, July-Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1394093

ABSTRACT

Abstract The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure the length of the NB and GB. Furthermore, the amount of mineralized tissues at the NB and GB was performed. In the histomorphometry analysis the percentage of mineralized tissues at the NB and GB was obtained in two histological sections while the mineralized tissues were measure in the micro-CT varying the thresholds of the grayscale varying from 90-250 to 90-150 with 10 levels of variation between each one was applied. Then these data were correlated in order to check the higher r level between the histomorphometry and micro-CT thresholds intervals. The linear length of the NB was 2.44±0.91mm and 2.48±1.50mm, respectively, for micro-CT and histomorphometry (r =0.57), while the linear length of the GB was 3.63±1.66mm and 3.13±1.45mm, respectively, for micro-CT and histomorphometry (r =0.74) Histomorphometry showed 45.91±11.69% of bone in NB, and 49.57±5.59% of bone and biomaterial in the GB. The total volume of mineralized tissues that were closest to the histometric analysis were 43.75±15.39% in the NB (Threshold:90-240; r = 0.50) and 51.68±8.42% in the GB (Threshold:90-180; r =-0.028). The micro-CT analysis showed good accuracy in the linear analysis in both portions of the biopsies but for volumetric analysis just in NB.


Resumo Esse estudo tem como objetivo avaliar a acurácia da análise microtomográfica em mensurações lineares e volumétricas em osso nativo (ON) e enxertado (OE). Para isso, 111 biópsias removidas de seios maxilares de pacientes enxertados com osso bovino desproteinizado foram coletadas e avaliadas. As medidas lineares foram realizadas para medir o comprimento do ON e do OE. Além disso, foi realizada a mensuração da quantidade de tecidos mineralizados em ON e OE. Na análise histomorfométrica a porcentagem de tecidos mineralizados do ON e OE foi obtida em dois cortes histológicos enquanto os tecidos mineralizados foram medidos em microtomografias variando os thresholds da escala de cinza variando de 90-250 a 90-150 com 10 níveis de variação entre cada. Em seguida, esses dados foram correlacionados para verificar o maior nível de R entre os intervalos dos thresholds testados na análise microtomográfica em relação aos dados obtidos na histomorfometria. O comprimento linear do ON foi de 2,44±0,91mm e 2,48±1,50mm, respectivamente, para análises microtomográfica e histomorfométrica (r=0,57), enquanto o comprimento linear do OE foi de 3,63±1,66mm e 3,13±1,45mm, respectivamente, para para análises microtomográfica e histomorfométrica (r =0,74) A histomorfometria detectou 45,91±11,69% de osso na porção de ON e 49,57±5,59% de osso e biomaterial na porção de OE. O volume total de tecidos mineralizados detectados pela análise microtomográfica que apresentou valores mais próximos da análise histomorfométrica foi de 43,75±15,39% no ON (Thresholds:90-240; r = 0,50) e 51,68±8,42% no OE (Thresholds:90-180; r =- 0,028). A análise microtomográfica apresentou boa acurácia na análise linear em ambas as porções das biópsias, porém a mesma apresentou boa acurácia para análise volumétrica apenas em áreas de ON.

19.
Braz Dent J ; 33(1): 105-111, 2022.
Article in English | MEDLINE | ID: mdl-35262548

ABSTRACT

This study evaluated osseointegration in areas grafted with deproteinized bovine bone (DBB) and biphasic ceramic based on hydroxyapatite and beta-tricalcium phosphate (HA/TCP) in rat tibias. Noncritical bone defects were made in the tibias of 28 rats that were randomly assigned to 2 groups: DBB: DBB-filled defects and HA/TCP: HA/TCP-filled defects. Bone defects were made in the tibias bilaterally and filled with biomaterials. After 60 days, the implants were inserted, and the animals were euthanized 15 and 45 days after the implants were installed. Osseointegration was evaluated by biomechanical, microtomographic and histometric analysis. Implants installed in the defects filled with DBB presented higher removal torque forces (2.33 ± 0.51 Ncm vs. 1.50 ± 0.54 Ncm) and mineralized tissue volume around implants at 15 days (34.96 ± 3.68 % vs. 25.61 ± 2.95 %) and greater bone-implant contact (20.87 ± 8.28 % vs. 11.52 ± 7.42 %) and bone area within implant threads (26.83 ± 12.35 % vs. 11.98 ± 7.56 %) at 45 days compared to the measurements of implants in areas grafted with HA/TCP. Implants installed in defects in areas grafted with DBB had a better osseointegration pattern than implants placed in defects in areas grafted with HA/TCP.


Subject(s)
Bone Substitutes , Dental Implants , Animals , Biocompatible Materials , Bone Regeneration , Cattle , Osseointegration , Rats
20.
Braz. dent. j ; 33(1): 105-111, jan.-fev. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1364483

ABSTRACT

Abstract This study evaluated osseointegration in areas grafted with deproteinized bovine bone (DBB) and biphasic ceramic based on hydroxyapatite and beta-tricalcium phosphate (HA/TCP) in rat tibias. Noncritical bone defects were made in the tibias of 28 rats that were randomly assigned to 2 groups: DBB: DBB-filled defects and HA/TCP: HA/TCP-filled defects. Bone defects were made in the tibias bilaterally and filled with biomaterials. After 60 days, the implants were inserted, and the animals were euthanized 15 and 45 days after the implants were installed. Osseointegration was evaluated by biomechanical, microtomographic and histometric analysis. Implants installed in the defects filled with DBB presented higher removal torque forces (2.33 ± 0.51 Ncm vs. 1.50 ± 0.54 Ncm) and mineralized tissue volume around implants at 15 days (34.96 ± 3.68 % vs. 25.61 ± 2.95 %) and greater bone-implant contact (20.87 ± 8.28 % vs. 11.52 ± 7.42 %) and bone area within implant threads (26.83 ± 12.35 % vs. 11.98 ± 7.56 %) at 45 days compared to the measurements of implants in areas grafted with HA/TCP. Implants installed in defects in areas grafted with DBB had a better osseointegration pattern than implants placed in defects in areas grafted with HA/TCP.


Resumo Este estudo avaliou a osseointegração em áreas enxertadas com osso bovino desproteinizado (DBB) e cerâmica bifásica à base de hidroxiapatita e beta-fosfato tricálcico (HA / TCP) em tíbias de ratos. Defeitos ósseos não críticos foram feitos nas tíbias de 28 ratos que foram divididos aleatoriamente em 2 grupos: DBB: defeitos preenchidos com DBB e HA / TCP: defeitos preenchidos com HA / TCP. Defeitos ósseos foram confeccionados nas tíbias bilateralmente e preenchidos com biomateriais. Após 60 dias, os implantes foram instalados e os animais sacrificados 15 e 45 dias após a instalação dos implantes. A osseointegração foi avaliada por análises biomecânica, microtomográfica e histométrica. Os implantes instalados nos defeitos preenchidos com DBB apresentaram maiores forças de torque de remoção (2,33 ± 0,51 Ncm vs. 1,50 ± 0,54 Ncm) e volume de tecido mineralizado ao redor dos implantes aos 15 dias (34,96 ± 3,68% vs. 25,61 ± 2,95%) e maior contato osso-implante (20,87 ± 8,28% vs. 11,52 ± 7,42%) e área de osso dentro das roscas do implante (26,83 ± 12,35% vs. 11,98 ± 7,56%) no período de 45 dias em comparação com os implantes em áreas enxertadas com HA / TCP. Implantes instalados em áreas enxertadas com DBB apresentaram melhor padrão de osseointegração do que implantes colocados em áreas enxertadas com HA / TCP.

SELECTION OF CITATIONS
SEARCH DETAIL
...