Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
Br J Ophthalmol ; 106(1): 32-36, 2022 01.
Article in English | MEDLINE | ID: mdl-33093153

ABSTRACT

BACKGROUND/AIMS: We analysed the ability of B-scan ultrasound, ocular electrophysiology testing and videoendoscopic examination for predicting visual prognosis in Boston Type 1 keratoprosthesis (KPro-1) candidates. Indirect anatomical and electrophysiological findings and results from direct endoscopic evaluations were correlated with postoperative functional data. METHODS: In this prospective and interventional study, we included 13 individuals who had previously been indicated for Kpro-1 surgery. All subjects underwent preoperative screening, including ophthalmic evaluation, B-scan ultrasound, electrophysiological testing, and perioperative intraocular videoendoscopic evaluation (VE). B-scan ultrasound, electrophysiological testing, and VE evaluation results were categorised as favourable or unfavourable predictors of postoperative functional results according to predefined criteria. The predictability values of B-scan ultrasound, electrophysiological testing, and VE prognostication were calculated based on the visual acuity level achieved. RESULTS: All surgeries and perioperative VEs were uneventful. Preoperative best-corrected visual acuity (BCVA) ranged from light perception to counting fingers. The 1-year postoperative BCVA was better than 20/200 (satisfactory visual acuity result) in 10 eyes (76.9%) and 20/40 or better in 5 eyes (38.5%). B-scan ultrasound presented a positive predictive value (PPV) of 85.7% for satisfactory postoperative visual acuity, electroretinography showed a PPV of 66.7%, and visual evoked potential presented a PPV of 66.7%. The perioperative VE PPV of a negative finding for satisfactory visual acuity was 100%. CONCLUSIONS: Fundoscopic visualisation by intraocular VE is a minimally invasive procedure that can be used to predict functional outcomes in keratoprosthesis candidates. This technique demonstrated better prognostication in keratoprosthesis candidates than B-scan ultrasound and electrophysiological testing.


Subject(s)
Artificial Organs , Corneal Diseases , Cornea/diagnostic imaging , Cornea/surgery , Corneal Diseases/diagnosis , Corneal Diseases/surgery , Electrophysiology , Evoked Potentials, Visual , Humans , Postoperative Complications/surgery , Prospective Studies , Prostheses and Implants , Prosthesis Implantation/methods , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL