Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Article in English | MEDLINE | ID: mdl-39289334

ABSTRACT

BACKGROUND: Mortgage discrimination refers to the systematic withholding of home mortgages from minoritized groups. In recent years, there has been an increase in empirical research investigating associations of historical and contemporary mortgage discrimination on contemporary  outcomes. Investigators have used a variety of measurement methods and approaches, which may have implications for results and interpretation. PURPOSE: We conducted a systematic review of peer-reviewed literature that has quantified links between both historical and current mortgage discrimination with contemporary adverse environmental, social, and health outcomes. Our goals were to document the methodology used to measure and assign mortgage discrimination, to assess implications for results and interpretation, and to make recommendations for future work. METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, literature searches were conducted in September 2022 using terms that combined concepts of mortgage discrimination, health, and neighborhood environment. RESULTS: In total, 45 papers fit the eligibility criteria. In these, researchers investigated associations between mortgage discrimination and: (1) health outcomes (N = 28); (2) environmental and social exposures including heat, air pollution, greenspace, soil lead levels, and crime (N = 12); and (3) built environment features, including presence of retail alcohol, fast food, and tobacco stores (N = 5). Eleven included studies used Home Mortgage Discrimination Act (HMDA) data to identify racialized bias in mortgage discrimination or redlining, and 34 used Homeowner Loan Corporation (HOLC) maps. The construction and parametrization of mortgage discrimination or redlining and the spatial assignment of HOLC grades to contemporary addresses or neighborhoods varied substantially across studies. CONCLUSIONS: Results from our review suggest the need for careful consideration of optimal methods to analyze mortgage discrimination such as HOLC spatial assignment or HMDA index parametrization, contemplation of covariates, and place-based knowledge of the study location.

2.
HSS J ; 20(2): 268-273, 2024 May.
Article in English | MEDLINE | ID: mdl-39281986

ABSTRACT

Background: Recreational and medicinal cannabis use is becoming increasingly popular, but there are little data on its effect on postoperative pain and opioid consumption after primary total knee arthroplasty (TKA). Purpose: We sought to evaluate the relationship between self-reported preoperative cannabis use and postoperative opioid consumption and post-discharge opioid prescriptions following elective primary TKA. Methods: We identified all patients who underwent unilateral, primary TKA for a diagnosis of osteoarthritis at a single institution between February 1, 2019, and April 30, 2021, and subdivided them into current cannabis users and non-users based on self-reported data. Regular users were propensity score-matched 1:6 with non-users using logistic regression on age, sex, body mass index (BMI), history of chronic pain, smoking status, history of anxiety/depression, American Society of Anesthesiology (ASA) classification, and type of anesthesia. Outcomes of interest included median inpatient (total, daily, and hourly) morphine milligram equivalents (MMEs), discharge MMEs, and outpatient MMEs within 90 days after surgery. Results: A cohort of 70 current cannabis users was matched with 420 non-users. There were no significant differences in opioid use in inpatient MMEs (hourly, daily, or total), discharge MMEs, or outpatient MMEs between cohorts. Also, there was no significant difference in hospital stay between cohorts. Conclusion: In this retrospective propensity score-matched model, preoperative cannabis use did not independently increase opioid use post-TKA in the inpatient or outpatient setting when compared with non-use. More rigorous, prospective study is warranted.

3.
J Robot Surg ; 18(1): 273, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38949665

ABSTRACT

Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Hip/methods , Robotic Surgical Procedures/methods , Fluoroscopy/methods , Tomography, X-Ray Computed/methods , Female , Male , Middle Aged , Aged , Hip Prosthesis , Acetabulum/surgery , Acetabulum/diagnostic imaging , Surgery, Computer-Assisted/methods
4.
Int J Med Robot ; 20(3): e2650, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38856120

ABSTRACT

BACKGROUND: The purpose of this study was to compare one-year patient reported outcome measures between a novel fluoroscopy-based robotic-assisted (FL-RTHA) system and an existing computerised tomography-based robotic assisted (CT-RTHA) system. METHODS: A review of 85 consecutive FL-RTHA and 125 consecutive CT-RTHA was conducted. Outcomes included one-year post-operative Veterans RAND-12 (VR-12) Physical (PCS)/Mental (MCS), Hip Disability and Osteoarthritis Outcome (HOOS) Pain/Physical Function (PS)/Joint replacement, and University of California Los Angeles (UCLA) Activity scores. RESULTS: The FL-RTHA cohort had lower pre-operative VR-12 PCS, HOOS Pain, HOOS-PS, HOOS-JR, and UCLA Activity scores compared with patients in the CT-RTHA cohort. The FL-RTHA cohort reported greater improvements in HOOS-PS scores (-41.54 vs. -36.55; p = 0.028) than the CT-RTHA cohort. Both cohorts experienced similar rates of major post-operative complications, and had similar radiographic outcomes. CONCLUSIONS: Use of the fluoroscopy-based robotic system resulted in greater improvements in HOOS-PS in one-year relative to the CT-based robotic technique.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Tomography, X-Ray Computed , Humans , Fluoroscopy , Robotic Surgical Procedures/methods , Female , Male , Arthroplasty, Replacement, Hip/methods , Middle Aged , Aged , Treatment Outcome , Retrospective Studies , Hip Joint/surgery , Hip Joint/diagnostic imaging
5.
J Clin Orthop Trauma ; 51: 102404, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38638118

ABSTRACT

Introduction: Some modern imageless navigation platforms for total hip arthroplasty (THA) rely on virtual frontal and sagittal planes determined with the patient in the lateral decubitus position. Body morphometry that changes with gender, body mass index, and other demographic factors may affect accuracy in patient positioning and consequently, navigation accuracy. The objective of this study was to analyze the influence of patient factors on the intraoperative accuracy of a second-generation imageless computer-assisted surgery platform. Methods: 325 consecutive patients undergoing posterior approach, navigated THA arthroplasty for primary osteoarthritis by a single surgeon were retrospectively reviewed. An optic-based imageless navigation system referenced off a generic sagittal and coronal plane was used to determine acetabular inclination and anteversion. Acetabular accuracy was determined by assessing differences between intraoperative values and those obtained from measuring standardized 6-week follow-up radiographs. The effect of age, gender, BMI, race, ethnicity, and laterality on acetabular accuracy was assessed via t-tests, Pearson correlation and ANOVA. Results: Gender had a significant impact on raw inclination accuracy (females and males had an average error of 1.41° and -1.03°, respectively - p < 0.001). There was a weak correlation between acetabular accuracy and patient age and BMI as a continuous variable (both absolute γ < 0.2). No difference was found between acetabular accuracy and BMI groups. Conclusion: This second-generation imageless computer assisted device provided accurate cup positioning regardless of patient's BMI. Gender was the only factor impacting inclination accuracy.

6.
Arch Orthop Trauma Surg ; 144(5): 1977-1987, 2024 May.
Article in English | MEDLINE | ID: mdl-38554209

ABSTRACT

INTRODUCTION: Prior studies investigating the racial and ethnic representation of orthopedic trial participants have found low rates of reporting, but these studies are dated due to the passing of the National Institutes of Health Final Rule in 2017 requiring the reporting of racial and ethnic data among clinical trials. Therefore, we evaluated the representativeness of orthopedic clinical trials before and after the Final Rule. METHODS: A cross-sectional survey of orthopaedic clinical trials registered at ClinicalTrials.gov between October 1, 2007 and May 20, 2023 was conducted. After identifying and screening 23,752 clinical trials, 1564 trials were included in the analysis. Trials started before the implementation of the Final Rule on January 18, 2017 were grouped and compared to trials that began after. Odds ratios (OR) were utilized to identify trial characteristics associated with reporting race/ethnicity data. One-proportion z tests compared the representation of each racial and ethnic category to the 2020 United States Census. RESULTS: In total, 34% (544 of 1564) of orthopedic clinical trials evaluated reported the race of participants, while 28% (438 of 1564) reported ethnicity. Trials registered after the Final Rule were more likely to report racial (OR: 5.15, 95%CI: 3.72-7.13, p < 0.001) and ethnic (OR: 3.23, 95%CI: 2.41-4.33, p < 0.001) representation of participants. Compared with the distribution of race and ethnicity reported by the United States 2020 Census, orthopedic trials had 16.6% more White participants (95% CI 16.4%, 16.8%; p < 0.001), 3.2% fewer Black participants (95%CI 3.1%, 3.3%; p < 0.001), and 5.7% fewer Hispanic/Latino participants (95%CI 5.2%, 6.2%; p < 0.001). Trials with enrollment sizes over 100 participants were also more likely to report race and ethnicity, with odds increasing with increased sample size. CONCLUSIONS: The Final Rule marginally improved the reporting of race and ethnicity in orthopedic clinical trials, and underrepresentation of Black or African American, Multiracial, and Hispanic populations persists. LEVEL OF EVIDENCE: III.


Subject(s)
Clinical Trials as Topic , Orthopedic Procedures , Humans , Clinical Trials as Topic/statistics & numerical data , Cross-Sectional Studies , Ethnicity/statistics & numerical data , Orthopedic Procedures/statistics & numerical data , Orthopedics/statistics & numerical data , Racial Groups/statistics & numerical data , United States , Black or African American , Hispanic or Latino , White
7.
Indian J Orthop ; 58(2): 121-126, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38312909

ABSTRACT

Introduction: The use of imageless navigation in total hip arthroplasty (THA) is frequently associated with prolonged surgical times, predominantly during the learning period. The purpose of the present study was to characterize the learning period of a novel imageless navigation system, specifically as it related to surgical time and acetabular navigation accuracy. Materials and Methods: This was a retrospective observational study of a consecutive group of 158 patients who underwent primary unilateral THA for osteoarthritis by a team headed by a single surgeon. All procedures used an imageless navigation system to measure acetabular cup inclination and anteversion angles, referencing a generic sagittal and frontal plane. Navigation accuracy was determined by assessing differences between intraoperative inclination and anteversion values and those obtained from standardized 6-week follow-up radiographs. Operative time and navigation accuracy were assessed by plotting moving averages of 7 consecutive cases. The learning period was defined using Mann-Kendall trend analyses, student t-tests and nonlinear regression modeling based on surgical time and navigation accuracy. Alpha error was 0.05. Results: The average surgical time was 67.3 min (SD:9.2) (range 45-95). The average navigation accuracy for inclination was 0.01° (SD:4.2) (range - 10 to 10), and that for anteversion was - 4.9° (SD:3.8) (range - 14 to 5). Average surgical time and navigation accuracy were similar between the first and final cases in the series with no learning period detected. Conclusions: There was no discernible learning period effect on surgical time or system measurement accuracy during the early phases of adoption for this imageless navigation system.

8.
Eur J Microbiol Immunol (Bp) ; 14(1): 13-25, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38305804

ABSTRACT

Staphylococcus aureus infections have already presented a substantial public health challenge, encompassing different clinical manifestations, ranging from bacteremia to sepsis and multi-organ failures. Among these infections, methicillin-resistant S. aureus (MRSA) is particularly alarming due to its well-documented resistance to multiple classes of antibiotics, contributing significantly to global mortality rates. Consequently, the urgent need for effective treatment options has prompted a growing interest in exploring phage therapy as a potential non-antibiotic treatment against MRSA infections. Phages represent a class of highly specific bacterial viruses known for their ability to infect certain bacterial strains. This review paper explores the clinical potential of phages as a treatment for MRSA infections due to their low toxicity and auto-dosing capabilities. The paper also discusses the synergistic effect of phage-antibiotic combination (PAC) and the promising results from in vitro and animal model studies, which could lead to extensive human clinical trials. However, clinicians need to establish and adhere to standard protocols governing phage administration and implementation. Prominent clinical trials are needed to develop and advance phage therapy as a non-antibiotic therapy intervention, meeting regulatory guidelines, logistical requirements, and ethical considerations, potentially revolutionizing the treatment of MRSA infections.

9.
Arch Orthop Trauma Surg ; 144(4): 1843-1850, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38400899

ABSTRACT

INTRODUCTION: The adoption of new technology should be supported by improvements in patient-reported outcomes (PROMs). The purpose of this study was to assess the one-year PROMs of patients who underwent total hip arthroplasty (THA) using a novel, fluoroscopy-based, robotic-assisted (RA-THA) system when compared to a manual, fluoroscopic-assisted technique (mTHA). MATERIALS AND METHODS: A review of 91 consecutive mTHA and 85 consecutive RA-THA via a direct anterior approach was conducted. All cases were performed by the same surgeon at the same institution, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included one-year Veterans RAND-12 (VR-12) Physical/Mental, Hip Disability and Osteoarthritis Outcome (HOOS) Pain/Physical Function/Joint Replacement, and University of California Los Angeles (UCLA) Activity scores, as well as the difference between pre-operative and one-year post-operative PROMs. RESULTS: Patients in the RA-THA cohort had lower pre-operative HOOS-JR scores compared to patients in the mTHA cohort (37.0 vs. 43.1; p = 0.031). Cohorts experienced similar one-year post-operative VR-12, HOOS, and UCLA Activity scores. Patients in the RA-THA cohort experienced greater improvements across all pre- and post-operative HOOS scores compared to patients in the mTHA cohort: Pain (+ 54.7 vs. +42.1; p = 0.009), Physical Function (-41.6 vs. -28.7; p = 0.007), and Joint Replacement (+ 46.6 vs. +33.0; p = 0.002). These differences exceeded minimum clinically important difference (MCID). CONCLUSIONS: Both manual and robotic cohorts experienced benefit from THA at one-year post-operative. Importantly, the use of a novel, fluoroscopy-based robotic assistance system for primary THA resulted in greater improvements in PROMs at one-year relative to manual technique.


Subject(s)
Arthroplasty, Replacement, Hip , Osteoarthritis , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Hip/methods , Robotic Surgical Procedures/methods , Treatment Outcome , Patient Reported Outcome Measures , Pain , Fluoroscopy
10.
J Arthroplasty ; 39(2): 480-482, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37454949

ABSTRACT

BACKGROUND: The use of double gloving has become a standard practice for joint replacement surgeons. However, since there are limited data on how gloves are contaminated during both primary and revision arthroplasty, no precise protocol exists to direct surgeons on when, or if, to change their gloves. The goals of this preliminary study were to evaluate the contamination of gloves during total joint arthroplasties (TJAs). METHODS: We included 25 infected cases and 10 primaries, which were performed at the same institution using the same surgical protocol from 3 fellowship trained surgeons. Samples were taken every 20 minutes from the start of the surgery until the joint was irrigated. Procedural steps were noted. To evaluate cross-contamination during infected cases, we sampled gloves using blood agar plates. In primary cases, culture swabs of anterior chamfer cuts and sterile instruments on the back table were used as negative controls. Next-generation sequencing (NGS) was used as an adjunct to identify low virulence bacteria. RESULTS: In the primary cases, all samples were found culture negative but 3 (8.1%) of the 37 samples were found to have a low, unidentifiable bacterial mass via NGS testing. In the infected cases, 41 (59.4%) of the 69 samples yielded positive microbial results. The positivity rate was higher in the samples collected after the arthrotomy was performed (70%) compared to samples collected before the arthrotomy was performed (40%), and the surgeon was only dissecting superficial layers (P = .502). CONCLUSION: Gloves seem to be a common source of cross-contamination in the intraoperative field during revision TJA. Due to the higher percent of positive samples following the opening of the joint, we hypothesize that the arthrotomy allows for the spread of bacteria across the operative site. While further investigation is necessary to formulate a precise protocol for the changing of gloves during TJA, it may be beneficial to perform a thorough irrigation of the joint and change of the gloves immediately following arthrotomy.


Subject(s)
Arthritis, Infectious , Arthroplasty, Replacement , Prosthesis-Related Infections , Humans , Prosthesis-Related Infections/surgery , Reoperation , Bacteria , Gloves, Surgical/microbiology
11.
Technol Health Care ; 2023 Nov 09.
Article in English | MEDLINE | ID: mdl-37980586

ABSTRACT

BACKGROUND: Robotic assistance in total hip arthroplasty (RA-THA) has been shown to minimize laterality-based differences in acetabular cup positioning. OBJECTIVE: To determine if the use of a novel, fluoroscopy-based RA-THA system mitigates differences in acetabular cup placement between left (L) and right (R) side hip procedures, when compared to manual, fluoroscopic-assisted technique. METHODS: We conducted a retrospective review of 106 consecutive mTHA (40 L/66 R) and 102 RA-THA (48 L/54 R) primary direct anterior approach procedures. All cases were performed by a single right-hand-dominant surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: The average inclination of mTHA L cases was smaller than that of mTHA R cases (41.10∘± 7.38 vs. 43.97∘± 6.27; p= 0.04). For RA-THA, L and R cup angles were similar. There were fewer overall mTHA hips within the Lewinnek safe-zone compared to RA-THA (0.59 vs. 0.78; p= 0.003), as well as fewer mTHA R cases than RA-THA R cases (0.59 vs. 0.80; p= 0.03) within safe zone. CONCLUSION: Use of a novel, fluoroscopy-based robotic system mitigates laterality-based differences in acetabular cup placement that were observed in a manual, fluoroscopic-assisted cohort.

12.
Technol Health Care ; 2023 Nov 09.
Article in English | MEDLINE | ID: mdl-37980587

ABSTRACT

BACKGROUND: Patient obesity is a risk factor for poor acetabular cup positioning in total hip arthroplasty (THA). OBJECTIVE: To assess the impact of using a novel, fluoroscopy-based robotic THA system on acetabular cup placement in obese versus non-obese patients. METHODS: A review of 105 consecutive manual unassisted (mTHA) (47 Obese/58 Non-obese) and 102 robotic-assisted (RA-THA) (50 Obese/52 Non-obese) primary, direct anterior approach THA procedures was conducted. All cases were performed by a single surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Obesity was defined as a Body Mass Index (BMI) ⩾ 30 kg/m2. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: Obese patients in the mTHA cohort had larger cup inclination angles on average compared to non-obese patients (44.82∘± 6.51 vs. 41.39∘± 6.75; p= 0.009). Obese mTHA patients were less likely to have cup placement within the Lewinnek zone compared to non-obese mTHA patients (0.48 vs. 0.67; p= 0.027). Obesity had no effect on the accuracy of RA-THA. CONCLUSION: Obesity affects the placement of the acetabular component in manual THA. The novel, fluoroscopy-based robotic THA system in this study demonstrated accurate cup placement regardless of obesity status.

13.
J Robot Surg ; 17(6): 2841-2847, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37770721

ABSTRACT

Robotic-assisted total hip arthroplasty (THA) using a computerized-tomography (CT) based workflow increases surgical time relative to traditional manual technique. The purpose of this investigation was to compare the intra-operative efficiencies of two robotic THA systems: a fluoroscopy-based platform (FL-RTHA) and a contemporary, CT-based (CT-RTHA) platform. A review of 107 consecutive FL-RTHA and 159 CT-RTHA primary, direct anterior approach (DAA) THA procedures was conducted. All cases were performed by one of two surgeons operating at the same institution, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included averages and consistencies (variances) for surgical times and operating room (OR) times. A secondary outcome was to quantify the duration of robot-active phases in the FL-RTHA workflow. The FL-RTHA cohort experienced shorter surgical times (38.71 min ± 7.00 vs. 75.33 min ± 11.38; p < 0.001) and OR times (101.35 min ± 12.22 vs. 156.74 min ± 17.79; p < 0.001) compared to the CT-RTHA cohort. Surgical times and OR times were both more consistent in the FL-RTHA cohort compared to the CT-RTHA cohort (p < 0.001). Patients who underwent DAA THA with the assistance of a fluoroscopy-based robotic system experienced shorter and more consistent surgical times and OR times compared to patients who underwent similar DAA THA procedures with a contemporary, CT-based robotic platform.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Robotics , Humans , Arthroplasty, Replacement, Hip/methods , Robotic Surgical Procedures/methods , Fluoroscopy , Tomography, X-Ray Computed , Retrospective Studies
14.
Int J Med Robot ; : e2582, 2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37776329

ABSTRACT

BACKGROUND: The purpose of this study was to assess the cost-effectiveness of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty (RA-THA) system compared to a manual unassisted technique (mTHA) up to 5 years post-operatively. METHODS: A Markov model was constructed to compare the cost-effectiveness of RA-THA and mTHA. Cost-effectiveness was defined as an Incremental Cost-Effectiveness Ratio (ICER) <$50 000 or $100 000 per Quality Adjusted Life Year (QALY). RESULTS: RA-THA patients experienced lower costs compared to mTHA patients at 1 year ($20 865.12 ± 9897.52 vs. $21 660.86 ± 9909.15; p < 0.001) and 5 years ($23 124.57 ± 10 045.48 vs. $25 756.42 ± 10 091.84; p < 0.001) post-operatively. RA-THA patients also accrued more QALYs (1-year: 0.901 ± 0.117 vs. 0.888 ± 0.114; p < 0.001; 5-years: 4.455 ± 0.563 vs. 4.384 ± 0.537 p < 0.001). Overall, RA-THA was cost-effective (1-year ICER: $-61 210.77; 5-year ICER: $-37 068.31). CONCLUSIONS: The novel, fluoroscopy-based RA-THA system demonstrated cost-effectiveness when compared to manual unassisted THA.

16.
J Robot Surg ; 17(4): 1561-1567, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36913058

ABSTRACT

Accurate and precise positioning of the acetabular cup remains a prevalent challenge in total hip arthroplasty (THA). Robotic assistance for THA has increased over the past decade due to the potential to improve the accuracy of implant placement. However, a common criticism of existing robotic systems is the requirement for preoperative computerized tomography (CT) scans. This additional imaging increases patient radiation exposure, as well as cost, and requires pin placement during surgery. The goal of this study was to analyze the radiation burden associated with a novel, CT-free robotic THA system compared to an unassisted manual THA approach (n = 100/arm). On average, the study cohort had a higher number of fluoroscopic images captured (7.5 vs. 4.3 images; p < 0.001), radiation dose (3.0 vs. 1.0 mGy; p < 0.001), and a longer duration of radiation exposure (18.8 vs. 6.3 s; p < 0.001), per procedure, than the control group. Additionally, no learning curve was detected by CUSUM analysis with respect to the number of fluoroscopic images taken during the adoption of the robotic THA system. While statistically significant, in comparison to published literature, the radiation exposure of the CT-free robotic THA system was comparable to that of unassisted manual THA approach and less than that of CT-based robotic approaches. Thus, the novel CT-free robotic system likely poses no clinically significant increase in radiation exposure to the patient compared to manual approaches.


Subject(s)
Arthroplasty, Replacement, Hip , Radiation Exposure , Robotic Surgical Procedures , Robotics , Humans , Arthroplasty, Replacement, Hip/methods , Robotic Surgical Procedures/methods , Case-Control Studies
17.
Arch Orthop Trauma Surg ; 143(5): 2739-2745, 2023 May.
Article in English | MEDLINE | ID: mdl-35776176

ABSTRACT

INTRODUCTION: Direct anterior approach (DAA) for total hip arthroplasty (THA) frequently utilizes fluoroscopy. The purpose of this study is to assess the impact of using a novel, imageless THA navigation system on radiation exposure and acetabular cup placement consistency. MATERIALS AND METHODS: This was a retrospective, single-surgeon cohort study of a consecutive group of patients who underwent DAA THA for osteoarthritis. An optic-based imageless navigation system was used to determine intraoperative acetabular inclination and anteversion angles referenced off of a generic coronal and sagittal plane in 71 cases (study group). These were compared with 71 manual cases (control group) for fluoroscopy exposure, operative duration, and acetabular placement variation. Cohorts were similar in their distributions of sex, race, ethnicity, and body mass index. Comparisons between groups were made using independent samples t tests. Alpha error was 0.05. RESULTS: Study patients experienced significantly less fluoroscopy exposure time {3.59 [Standard Deviation (SD) 1.95] vs. 9.15 (SD 5.98) seconds; p < 0.001} and dosage (0.30 [SD 0.23] vs. 0.78 [SD 0.63] mGy; p < 0.001). Study and control patients had similar operative times [82.69 (SD 11.70) vs. 89.54 (SD 14.60) minutes; p = 0.09]. The study group had a significantly lower radiographic variation for inclination and anteversion, based on mean proximity to the centroid of each cohort [3.55 (SD 1.88) vs. 5.39 (SD 3.51); p < 0.001] and also a greater proportion of cases that fell within 1 SD of the mean cohort inclination and anteversion (40.8% vs. 21.1%; p = 0.009). CONCLUSIONS: Use of a novel imageless navigation system for DAA THA significantly reduced fluoroscopic radiation exposure and improved consistency in acetabular cup placement.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Surgery, Computer-Assisted , Humans , Retrospective Studies , Case-Control Studies , Cohort Studies , Acetabulum/diagnostic imaging , Acetabulum/surgery , Fluoroscopy
18.
Arch Orthop Trauma Surg ; 143(3): 1579-1591, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35378597

ABSTRACT

INTRODUCTION: Elective orthopedic care, including in-person office visits and physical therapy (PT), was halted on March 16, 2020, at a large, urban hospital at the onset of the local COVID-19 surge. Post-discharge care was provided predominantly through a virtual format. The purpose of this study was to assess the impact of postoperative care disruptions on early total knee arthroplasty (TKA) outcomes, specifically 90-day complications, 120-day rate of manipulation under anesthesia (MUA) and 1-year patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Institutional records were queried to identify 624 patients who underwent primary, unilateral TKA for osteoarthritis and who were discharged home between 1/1/20 and 3/15/20. These patients were compared to 558 controls discharged between 1/1/19 and 3/15/2019. Cohort demographics and in-hospital characteristics were equivalent apart from inpatient morphine milligram equivalent (MME) consumption. Patient-reported access to PT (p < 0.001) and post-discharge care (p < 0.001) were worse among study patients. Study patients were prescribed fewer post-discharge PT sessions (19.8 vs. 23.5; p < 0.001) and utilized telehealth more frequently (p < 0.001). Mann-Whitney U, T, Fisher's Exact, and chi-squared tests were used to compare outcomes. RESULTS: Ninety-day CMS complications were lower among study patients (3.5% vs. 5.9%; p = 0.05). Rates of MUA were similar between groups. Study patients reported similar PROMs and marginally inferior VR-12 mental and LEAS functional outcomes at 1 year. CONCLUSION: Disruptions to elective orthopedic care in March 2020 seemed to have had no major consequences on clinical outcomes for TKA patients. Our findings question the usefulness of pre-pandemic post-discharge protocols, which may over-emphasize in-person visits and PT.


Subject(s)
Arthroplasty, Replacement, Knee , COVID-19 , Humans , Arthroplasty, Replacement, Knee/adverse effects , Postoperative Care , Aftercare , Patient Discharge , Patient Reported Outcome Measures , Retrospective Studies
19.
Arch Orthop Trauma Surg ; 143(6): 3629-3635, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36129515

ABSTRACT

PURPOSE: The recreational and medical use of cannabis is being legalized worldwide. Its use has been linked to an increased risk of developing opioid use disorders. As opioids continue to be prescribed after total hip arthroplasty (THA), the influence that preoperative cannabis use may have on postoperative opioid consumption remains unknown. The purpose of this study was to assess the relationship between preoperative cannabis use and opioid utilization following primary THA. METHODS: We identified all patients over the age of 18 who underwent unilateral, primary THA for a diagnosis of osteoarthritis at a single institution from February 2019 to April 2021. Our cohort was grouped into current cannabis users (within 6 months of surgery) and those who reported never using cannabis. One hundred and fifty-six current users were propensity score matched 1:6 with 936 never users based on age, sex, BMI, history of chronic pain, smoking status, history of anxiety/depression, ASA classification and type of anesthesia. Outcomes included inpatient and postdischarge opioid use in morphine milligram equivalents. RESULTS: Total inpatient opioid utilization, opioids refilled, and total opioids used within 90 postoperative days were similar between the groups. CONCLUSION: In propensity score matched analyses, preoperative cannabis use was not independently associated with an increase in inpatient or outpatient, 90-days opioid consumption following elective THA.


Subject(s)
Arthroplasty, Replacement, Hip , Cannabis , Opioid-Related Disorders , Humans , Adult , Middle Aged , Analgesics, Opioid/therapeutic use , Arthroplasty, Replacement, Hip/adverse effects , Aftercare , Pain, Postoperative/drug therapy , Pain, Postoperative/etiology , Retrospective Studies , Patient Discharge , Opioid-Related Disorders/epidemiology
20.
Arch Orthop Trauma Surg ; 143(8): 4625-4632, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36550383

ABSTRACT

INTRODUCTION: In June 2020 when elective total knee arthroplasty (TKA) resumed after the initial COVID-19 surge, we adapted our TKA pathway focusing on a shorter hospitalization, increased home discharge, and use of post-discharge telemedicine and telerehabilitation. The purpose of this study was to evaluate if changes in postoperative care affected early TKA outcomes. MATERIALS AND METHODS: Five hundred and fifty-four patients who underwent elective primary unilateral TKA for primary osteoarthritis between June and August 2020 (study group) were matched 1:1 for age, sex, body mass index, and Charlson comorbidity index with control patients who underwent surgery between August and November 2019. Study patients were discharged 25 h earlier on average compared to controls, more frequently on the same-day or postoperative day-1 (24.9% vs. 16.1%; p = 0.001), and more frequently home (97.3% vs. 83.8%; p < 0.001). Study patients used telemedicine (11.7% vs. 0%; p < 0.001) and telerehabilitation (19.7% vs. 2.5%; p < 0.001) at higher rates than controls. Generalized estimating equations, Mann-Whitney U, and Chi-Square tests were used to compare outcomes between groups including unscheduled office visits, ER visits, readmissions, Center for Medicare and Medicaid Services (CMS) complications, manipulation under anesthesia (MUA), and patient-reported outcomes measures (PROMs). RESULTS: Rates of emergency room visits, readmissions, CMS complications, MUA, and improvements in PROMs were similar between cohorts. Study patients experienced higher rates of unscheduled outpatient visits (9.2% vs. 4.9%; p = 0.004), predominantly due to wound complications. CONCLUSIONS: A protocol implemented during the COVID-19 pandemic that leveraged a shortened hospitalization, higher rates of home discharge, and increased use of telemedicine and telerehabilitation was safe and effective.


Subject(s)
Arthroplasty, Replacement, Knee , COVID-19 , Humans , Aged , United States , Arthroplasty, Replacement, Knee/adverse effects , Aftercare , Pandemics , Patient Discharge , COVID-19/epidemiology , Medicare , Postoperative Complications/epidemiology , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL