1.
Hip Int ; 26(3): 254-9, 2016 May 16.
Article in English | MEDLINE | ID: mdl-27079286

ABSTRACT

INTRODUCTION: During total hip arthroplasty (THA), accurately predicting acetabular cup orientation remains a key challenge, in great part because of uncertainty about pelvic orientation. This pilot study aimed to develop and validate a technique to measure pelvic orientation; establish its accuracy in the location of anatomical landmarks and subsequently; investigate if limb movement during a simulated surgical procedure alters pelvic orientation. METHODS: The developed technique measured 3-D orientation of an isolated Sawbone pelvis, it was then implemented to measure pelvic orientation in lateral decubitus with post-THA patients (n = 20) using a motion capture system. RESULTS: Orientation of the isolated Sawbone pelvis was accurately measured, demonstrated by high correlations with angular data from a coordinate measurement machine; R-squared values close to 1 for all pelvic axes. When applied to volunteer subjects, largest movements occurred about the longitudinal pelvic axis; internal and external pelvic rotation. Rotations about the anteroposterior axis, which directly affect inclination angles, showed >75% of participants had movement within ±5° of neutral, 0°. CONCLUSIONS: The technique accurately measured orientation of the isolated bony pelvis. This was not the case in a simulated theatre environment. Soft tissue landmarks were difficult to palpate repeatedly. These findings have direct clinical relevance, landmark registration in lateral decubitus is a potential source of error, contributing here to large ranges in measured movement. Surgeons must be aware that present techniques using bony landmarks to reference pelvic orientation for cup implantation, both computer-based and mechanical, may not be sufficiently accurate.


Subject(s)
Acetabulum/anatomy & histology , Arthroplasty, Replacement, Hip/methods , Hip Joint/physiology , Joint Instability/prevention & control , Range of Motion, Articular/physiology , Surgery, Computer-Assisted/methods , Aged , Female , Humans , Male , Middle Aged , Orientation, Spatial/physiology , Pilot Projects , Preoperative Care/methods , Risk Factors , Rotation , Sensitivity and Specificity
2.
Ultrasonics ; 56: 279-86, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25260486

ABSTRACT

Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions. Results indicated that the ultrasonic pulse-echo technique provided a highly reproducible and accurate method of monitoring the polymerisation reaction and indicating the principal setting parameters when compared to ISO 5833 standard, irrespective of the acrylic bone cement or mixing method used. However, applying the same test method to predict the final mechanical properties of acrylic bone cement did not prove a wholly accurate approach. Inhomogeneities within the cement microstructure and specimen geometry were found to have a significant influence on mechanical property predictions. Consideration of all the results suggests that the non-invasive and non-destructive pulse-echo ultrasonic test method is an effective and reliable method for following the full polymerisation reaction of acrylic bone cement in real-time and then determining the setting properties within a surgical theatre environment. However the application of similar technology for predicting the final mechanical properties of acrylic bone cement on a consistent basis may prove difficult.


Subject(s)
Acrylates , Bone Cements/standards , Ultrasonics/methods , Mechanical Phenomena , Polymerization , Temperature
3.
Ann Biomed Eng ; 42(4): 751-62, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24395013

ABSTRACT

The aim of the study was to use a computational and experimental approach to evaluate, compare and predict the ability of calcium phosphate (CaP) and poly (methyl methacrylate) (PMMA) augmentation cements to restore mechanical stability to traumatically fractured vertebrae, following a vertebroplasty procedure. Traumatic fractures (n = 17) were generated in a series of porcine vertebrae using a drop-weight method. The fractured vertebrae were imaged using µCT and tested under axial compression. Twelve of the fractured vertebrae were randomly selected to undergo a vertebroplasty procedure using either a PMMA (n = 6) or a CaP cement variation (n = 6). The specimens were imaged using µCT and re-tested. Finite element models of the fractured and augmented vertebrae were generated from the µCT data and used to compare the effect of fracture void fill with augmented specimen stiffness. Significant increases (p < 0.05) in failure load were found for both of the augmented specimen groups compared to the fractured group. The experimental and computational results indicated that neither the CaP cement nor PMMA cement could completely restore the vertebral mechanical behavior to the intact level. The effectiveness of the procedure appeared to be more influenced by the volume of fracture filled rather than by the mechanical properties of the cement itself.


Subject(s)
Bone Cements , Calcium Phosphates , Polymethyl Methacrylate , Spinal Fractures/surgery , Spine/surgery , Vertebroplasty , Animals , Biomechanical Phenomena , Finite Element Analysis , Spinal Fractures/diagnostic imaging , Spine/diagnostic imaging , Swine , X-Ray Microtomography
4.
Proc Inst Mech Eng H ; 227(6): 629-35, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23636755

ABSTRACT

Restoration of joint centre during total hip arthroplasty is critical. While computer-aided navigation can improve accuracy during total hip arthroplasty, its expense makes it inaccessible to the majority of surgeons. This article evaluates the use, in the laboratory, of a calliper with a simple computer application to measure changes in femoral head centres during total hip arthroplasty. The computer application was designed using Microsoft Excel and used calliper measurements taken pre- and post-femoral head resection to predict the change in head centre in terms of offset and vertical height between the femoral head and newly inserted prosthesis. Its accuracy was assessed using a coordinate measuring machine to compare changes in preoperative and post-operative head centre when simulating stem insertion on 10 sawbone femurs. A femoral stem with a modular neck was used, which meant nine possible head centre configurations were available for each femur, giving 90 results. The results show that using this technique during a simulated total hip arthroplasty, it was possible to restore femoral head centre to within 6 mm for offset (mean 1.67 ± 1.16 mm) and vertical height (mean 2.14 ± 1.51 mm). It is intended that this low-cost technique be extended to inform the surgeon of a best-fit solution in terms of neck length and neck type for a specific prosthesis.


Subject(s)
Anthropometry/instrumentation , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Femur Head/anatomy & histology , Femur Head/surgery , Imaging, Three-Dimensional/methods , Models, Anatomic , Models, Biological , Surgery, Computer-Assisted/methods , Anthropometry/methods , Computer Simulation , Humans , Reproducibility of Results , Sensitivity and Specificity
5.
J Biomech ; 46(4): 711-5, 2013 Feb 22.
Article in English | MEDLINE | ID: mdl-23261249

ABSTRACT

The study aim was to develop and apply an experimental technique to determine the biomechanical effect of polymethylmethacrylate (PMMA) and calcium phosphate (CaP) cement on the stiffness and strength of augmented vertebrae following traumatic fracture. Twelve burst type fractures were generated in porcine three-vertebra segments. The specimens were randomly split into two groups (n=6), imaged using microCT and tested under axial loading. The two groups of fractured specimens underwent a vertebroplasty procedure, one group was augmented with CaP cement designed and developed at Queen's University Belfast. The other group was augmented with PMMA cement (WHW Plastics, Hull, UK). The specimens were imaged and re-tested . An intact single vertebra specimen group (n=12) was also imaged and tested under axial loading. A significant decrease (p<0.01) was found between the stiffness of the fractured and intact groups, demonstrating that the fractures generated were sufficiently severe, to adversely affect mechanical behaviour. Significant increase (p<0.01) in failure load was found for the specimen group augmented with the PMMA cement compared to the pre-augmentation group, conversely, no significant increase (p<0.01) was found in the failure load of the specimens augmented with CaP cement, this is attributed to the significantly (p<0.05) lower volume of CaP cement that was successfully injected into the fracture, compared to the PMMA cement. The effect of the percentage of cement fracture fill, cement modulus on the specimen stiffness and ultimate failure load could be investigated further by using the methods developed within this study to test a more injectable CaP cement.


Subject(s)
Bone Cements , Calcium Phosphates , Spinal Fractures/surgery , Vertebroplasty/methods , Animals , Biomechanical Phenomena , Disease Models, Animal , Humans , Lumbar Vertebrae/injuries , Lumbar Vertebrae/physiopathology , Lumbar Vertebrae/surgery , Polymethyl Methacrylate , Spinal Fractures/diagnostic imaging , Spinal Fractures/physiopathology , Stress, Mechanical , Sus scrofa , Thoracic Vertebrae/injuries , Thoracic Vertebrae/physiopathology , Thoracic Vertebrae/surgery , Weight-Bearing/physiology , X-Ray Microtomography
6.
Hip Int ; 22(6): 683-9, 2012.
Article in English | MEDLINE | ID: mdl-23233171

ABSTRACT

The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.


Subject(s)
Acetabulum/anatomy & histology , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Patient Positioning , Equipment Design , Humans
7.
J Biomed Mater Res A ; 100(9): 2223-9, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22829468

ABSTRACT

Bioresorbable polymers have been widely investigated as materials exhibiting significant potential for successful application in the fields of tissue engineering and drug delivery. Further to the ability to control degradation, surface engineering of polymers has been highlighted as a key method central to their development. Previous work has demonstrated the ability of electron beam (e-beam) technology to control the degradation profiles and bioresorption of a number of commercially relevant bioresorbable polymers (poly-l-lactic acid (PLLA), L-lactide/DL-lactide co-polymer (PLDL) and poly(lactic-co-glycolic acid (PLGA)). This work investigates the further potential of e-beam technology to impart added biofunctionality through the manipulation of polymer (PLLA) surface properties. PLLA samples were subjected to e-beam treatments in air, with varying beam energies and doses. Surface characterization was then performed using contact angle analysis, X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and atomic force microscopy. Results demonstrated a significant increase in surface wettability post e-beam treatment. In correlation with this, XPS data showed the introduction of oxygen-containing functional groups to the surface of PLLA. Raman spectroscopy indicated chain scission in the near surface region of PLLA (as predicted). However, e-beam effects on surface properties were not shown to be dependent on beam energy or dose. E-beam irradiation did not seem to affect the surface roughness of PLLA as a direct consequence of the treatment.


Subject(s)
Biocompatible Materials/chemistry , Lactic Acid/chemistry , Polymers/chemistry , Electrons , Microscopy, Atomic Force , Oxygen/chemistry , Photoelectron Spectroscopy , Polyesters , Spectrum Analysis, Raman , Surface Properties , Wettability
8.
Acta Biomater ; 8(11): 4043-52, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22800604

ABSTRACT

The aim of this study was to examine the potential of incorporating bovine fibres as a means of reinforcing a typically brittle apatite calcium phosphate cement for vertebroplasty. Type I collagen derived from bovine Achilles tendon was ground cryogenically to produce an average fibre length of 0.96±0.55 mm and manually mixed into the powder phase of an apatite-based cement at 1, 3 or 5 wt.%. Fibre addition of up to 5 wt.% had a significant effect (P ≤ 0.001) on the fracture toughness, which was increased by 172%. Adding ≤ 1 wt.% bovine collagen fibres did not compromise the compressive properties significantly, however, a decrease of 39-53% was demonstrated at ≥ 3wt.% fibre loading. Adding bovine collagen to the calcium phosphate cement reduced the initial and final setting times to satisfy the clinical requirements stated for vertebroplasty. The cement viscosity increased in a linear manner (R²=0.975) with increased loading of collagen fibres, such that the injectability was found to be reduced by 83% at 5 wt.% collagen loading. This study suggests for the first time the potential application of a collagen-reinforced calcium phosphate cement as a viable option in the treatment of vertebral fractures, however, issues surrounding efficacious cement delivery need to be addressed.


Subject(s)
Apatites/chemistry , Bone Cements/therapeutic use , Calcium Phosphates/therapeutic use , Collagen/chemistry , Materials Testing , Spinal Fractures/drug therapy , Spinal Fractures/surgery , Vertebroplasty , Animals , Cattle , Collagen/ultrastructure , Compressive Strength , Elastic Modulus , Rheology , Stress, Mechanical , Time Factors , Viscosity
9.
Acta Biomater ; 7(2): 548-57, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20849986

ABSTRACT

Predicable and controlled degradation is not only central to the accurate delivery of bioactive agents and drugs, it also plays a vital role in key aspects of bone tissue engineering. The work addressed in this paper investigates the utilisation of e-beam irradiation in order to achieve a controlled (surface) degradation profile. This study focuses on the modification of commercially and clinically relevant materials, namely poly(L-lactic acid) (PLLA), poly(L-lactide-hydroxyapatite) (PLLA-HA), poly(L-lactide-glycolide) co-polymer (PLG) and poly(L-lactide-DL-lactide) co-polymer (PLDL). Samples were subjected to irradiation treatments using a 0.5MeV electron beam with delivered surface doses of 150 and 500 kGy. In addition, an acrylic attenuation shield was used for selected samples to control the penetration of the e-beam. E-beam irradiation induced chain scission in all polymers, as characterized by reduced molecular weights and glass transition temperatures (T(g)). Irradiation not only produced changes in the physical properties of the polymers but also had associated effects on surface erosion of the materials during hydrolytic degradation. Moreover, the extent to which both mechanical and hydrolytic degradation was observed is synonymous with the estimated penetration of the beam (as controlled by the employment of an attenuation shield).


Subject(s)
Biocompatible Materials/chemistry , Electrons , Polymers/chemistry , Calorimetry, Differential Scanning , Chromatography, Gel , Crystallization , Durapatite/chemistry , Lactic Acid/chemistry , Microscopy, Electron, Scanning , Molecular Weight , Polyesters/chemistry , Polyglactin 910/chemistry , Stress, Mechanical , Surface Properties
10.
J Mater Sci Mater Med ; 20(12): 2427-31, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19655236

ABSTRACT

In this investigation Raman spectroscopy was shown to be a method that could be used to monitor the polymerisation of PMMA bone cement. Presently there is no objective method that orthopaedic surgeons can use to quantify the curing process of cement during surgery. Raman spectroscopy is a non-invasive, non-destructive technique that could offer such an option. Two commercially available bone cements (Palacos R and SmartSet HV) and different storage conditions (4 and 22 degrees C) were used to validate the technique. Raman spectroscopy was found to be repeatable across all conditions with the completion of the polymerisation process particularly easy to establish. All tests were benchmarked against current temperature monitoring methods outlined in ISO and ASTM standards. There was found to be close agreement with the standard methods and the Raman spectroscopy used in this study.


Subject(s)
Polymethyl Methacrylate/chemistry , Spectrum Analysis, Raman/methods , Reproducibility of Results , Temperature
11.
J Biomed Mater Res A ; 89(3): 567-74, 2009 Jun.
Article in English | MEDLINE | ID: mdl-18435410

ABSTRACT

The degradable polymers polylactide (PLA) and polylactide-co-glycolide (PLGA) have found widespread use in modern medical practice. However, their slow degradation rates and tendency to lose strength before mass have caused problems. The aim of this study was to ascertain whether treatment with e-beam radiation could address these problems. Samples of PLA and PLGA were manufactured and placed in layered stacks, 8.1 mm deep, before exposure to 50 kGy of e-beam radiation from a 1.5 MeV accelerator. Gel permeation chromatography testing showed that the molecular weight of both materials was depth-dependent following irradiation, with samples nearest to the treated surface showing a reduced molecular weight. Samples deeper than 5.4 mm were unaffected. Computer modeling of the transmission of a 1.5 MeV e-beam in these materials corresponded well with these findings. An accelerated mass-loss study of the treated materials found that the samples nearest the irradiated surface initiated mass loss earlier, and at later stages showed an increased percentage mass loss. It was concluded that e-beam radiation could modify the degradation of bioabsorbable polymers to potentially improve their performance in medical devices, specifically for improved orthopedic fixation.


Subject(s)
Electrons , Lactic Acid/chemistry , Lactic Acid/radiation effects , Polyesters/chemistry , Polyesters/radiation effects , Polyglycolic Acid/chemistry , Polyglycolic Acid/radiation effects , Radiation , Models, Molecular , Molecular Weight , Polylactic Acid-Polyglycolic Acid Copolymer
12.
Eur J Oral Sci ; 116(1): 83-8, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18186737

ABSTRACT

This study compared the mean loads and modes of failure of teeth restored with all-ceramic crowns (ACCs) cemented with dual-cured (RelyX ARC; 3M ESPE) or light-cured (RelyX Veneer; 3M ESPE) luting cements. Clinically, there are advantages of light-cured cements over the recommended dual-cured cements, namely increased working time, improved handling, colour stability, and a homogenous mix. Forty, sound, extracted, human, premolar teeth underwent a standardized preparation for ACCs. IPS Empress (Ivoclar-Vivadent) crowns of standard dimensions were fabricated and 20 were cemented with each cement. The crowns were stored for 1 or 30 d in water and subjected to a compressive load to failure at 0.017 mm s(-1). There were no significant differences in loads at failure, between each cement group, at each storage period, and there were no significant differences in loads at failure, for each cement, at 1 and 30 d of storage. There were also no significant differences in modes of failure between each cement group. Before recommending light-cured cement as an alternative to dual-cured cement for the cementation of all-ceramic crowns, further research is required to establish the depth of ceramic at which light-cured lutes fail to polymerize completely.


Subject(s)
Ceramics/chemistry , Crowns , Dental Cements/chemistry , Dental Prosthesis Retention/methods , Dental Restoration Failure , Bicuspid , Compressive Strength , Dental Cements/radiation effects , Humans , Light , Time Factors , Tooth Fractures , Tooth Preparation/methods , Weight-Bearing
13.
Biomaterials ; 26(24): 4993-5001, 2005 Aug.
Article in English | MEDLINE | ID: mdl-15769535

ABSTRACT

The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) has been shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional, compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship between clinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within the UHMWPE acetabular component. Individual patients' wear paths were determined prior to revision operation from hip joint kinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revision operation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantify the orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient's clinical gait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affecting the wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.


Subject(s)
Biocompatible Materials/chemistry , Equipment Failure Analysis/methods , Gait , Hip Prosthesis , Materials Testing/methods , Polyethylenes/chemistry , Weight-Bearing , Aged , Aged, 80 and over , Biocompatible Materials/analysis , Cohort Studies , Female , Humans , Male , Middle Aged , Oxidation-Reduction , Polyethylenes/analysis , Prosthesis Failure , Surface Properties
14.
Eur J Orthod ; 25(2): 117-25, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12737209

ABSTRACT

Photo-elastic models replicating a lower arch with a moderate degree of lower incisor crowding and a palatally displaced maxillary canine were used to evaluate the stresses transmitted to the roots of the teeth by initial alignment archwires. Six initial alignment archwires were compared, two multi-strand stainless steel wires, two non-super-elastic (stabilized martensitic form) nickel titanium wires, and two stress-induced super-elastic (austenitic active) nickel titanium wires. Three specimens of each archwire type were tested. Analysis of the photo-elastic fringe patterns, in the medium supporting the teeth, revealed that the non-super-elastic nickel titanium archwires produced the highest shear stresses (P = 0.001). However, the shear stresses generated by the super-elastic alignment archwires and the multi-strand stainless steel archwires were very similar (P = 1.00). These results show that even in situations where large deflections of initial alignment archwires are required, super-elastic archwires do not appear to have any marked advantage over multi-strand stainless steel alignment archwires in terms of the stresses transferred to the roots of the teeth.


Subject(s)
Orthodontic Wires , Tooth Movement Techniques/instrumentation , Analysis of Variance , Cuspid/physiopathology , Dental Alloys/chemistry , Humans , Incisor/physiopathology , Malocclusion/therapy , Mandible , Maxilla , Models, Biological , Nickel/chemistry , Orthodontic Appliance Design , Stainless Steel/chemistry , Stress, Mechanical , Titanium/chemistry , Tooth Crown/physiopathology , Tooth Eruption, Ectopic/therapy , Tooth Root/physiopathology