Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 81(10): 10D533, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21061474

ABSTRACT

The paper presents a study of Faraday rotation (FR) angle and Cotton­Mouton (CM) phase shift measurements to determine their mutual interaction and the validity of the linear models presently used in equilibrium codes. Comparison between time traces of measurements and model calculations leads to the result that only an exact numerical solution of Stokes equations can reproduce in all the experimental data. As a consequence, approximated linear models can be applied only in a limited range of plasma parameters. In general, the nonlinear coupling between FR and CM is important for the evaluation of polarimetry parameters.

2.
Rev Sci Instrum ; 81(5): 053507, 2010 May.
Article in English | MEDLINE | ID: mdl-20527097

ABSTRACT

An equivalent model of JET polarimeter is presented, which overcomes the drawbacks of previous versions of the fitting procedures used to provide calibrated results. First of all the signal processing electronics has been simulated, to confirm that it is still working within the original specifications. Then the effective optical path of both the vertical and lateral chords has been implemented to produce the calibration curves. The principle approach to the model has allowed obtaining a unique procedure which can be applied to any manual calibration and remains constant until the following one. The optical model of the chords is then applied to derive the plasma measurements. The results are in good agreement with the estimates of the most advanced full wave propagation code available and have been benchmarked with other diagnostics. The devised procedure has proved to work properly also for the most recent campaigns and high current experiments.

3.
Rev Sci Instrum ; 79(10): 10E517, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044499

ABSTRACT

In burning plasma fusion devices, fast ion transport plays a central role in the performances of the machines. Moreover the losses of energetic particles might cause severe damages on plasma facing components. Therefore real time measurements of fast ion transport would provide valuable information for safe and reliable plasma operations. In this paper, we examine the feasibility of a monitoring system based on active charge exchange recombination spectroscopy making use of the 0.5 MeV/amu ITER heating neutral beams for detecting fast (4)He(+2) (alphas) particles in ITER plasmas. There are two time scales relevant to fast ion dynamics: the first is the slowing down time of the distribution function which is of the order of 1 s, and the second is the time scale of burstlike transport events such as collective Alfven mode excitations, which--for typical ITER plasma parameters--can be as low as 0.2-1 ms. To detect such fast events a broadband high-throughput spectrometer is needed, while for the reconstruction of the alpha velocity distribution function a higher resolution spectrometer and longer integration time are necessary. To monitor a spatial redistribution of fast particles due to the propagation of the instability, it is proposed to use a limited number of spatial channels, looking at the charge exchange He II spectra induced by the heating beams, whose energy matches the slowing down energies of fast particles. The proposal is to share the motional stark effect periscope on equatorial port 3 [A. Malaquias et al., Rev. Sci. Instrum. 75, 3393 (2004)] adding additional fibers and suitable instruments. A signal to noise ratio of 5 could be achieved with a spatial resolution of a/15 and a time resolution of 5 ms, in a broad spectral band of 100 A, corresponding to the spectral broadening of the line emitted by alpha particles with energies DeltaE < or = 1.5 MeV. Fast H and D ion populations created by heating neutral beam or ion cyclotron resonance heating are expected to produce significantly lower charge exchange signal levels and can only be monitored on substantially longer time scales as it is expected because of the strong energy difference with respect to the heating neutral beam and the consequently low charge exchange cross sections.

4.
Rev Sci Instrum ; 78(4): 043506, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17477659

ABSTRACT

We first describe the improved receiving system of the diagnostic experiment of millimeter-wave collective Thomson scattering being run on the Frascati Tokamak Upgrade (FTU), and then discuss some peculiar problems and new operating procedures related to the investigation of strong anomalous spectra of nonthermal origin, many-orders-of-magnitude stronger than the ion thermal feature merged in them, systematically observed in the experimentation, and finally ascribed to a perturbation of the gyrotron that generates the probing beam. Arguments in favor of a more general valence of the solutions actuated for the specific case of FTU are finally given.

5.
Opt Lett ; 14(9): 456-8, 1989 May 01.
Article in English | MEDLINE | ID: mdl-19749951

ABSTRACT

We report experimental evidence of the multistability of reshaped pulses that are observed when a 1.5-nsec CO(2)-laser pulse interacts with a pure SF(6) absorber. The data demonstrate that the dependence of the reshaped pulse delay on peak power is not a single-valued function under various experimental conditions.

SELECTION OF CITATIONS
SEARCH DETAIL
...