Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Int J Clin Pract ; 75(8): e14216, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33864337

ABSTRACT

AIMS: To compare the efficacy of different laser devices and power ranges on lithotripsy in retrograde intrarenal surgery (RIRS) for 1-2 cm kidney stones. METHODS: A total of 223 participants undergoing RIRS for 1-2 cm kidney stones at our clinic between January 2015 and January 2017 were recruited for this prospective study (NCT02451319). Two hundred and four participants included in our study were randomly allocated into either ≤20 W with 20 W laser device (group 1) or ≤20 W with 30 W laser device (group 2) or >20 W with 30 W laser device (group 3). RESULTS: There was no significant difference between the groups in terms of demographic and stone characteristics. Operation and fluoroscopy times were significantly longer (P = .003 and P < .001, respectively) and stone-free rate (SFR) was significantly lower in group 1 (P = .002). Complications were similar in all three groups (P = .512). However, post-operative pain scores were significantly higher in group 1 (P < .001). The multivariate analysis revealed that stone size (95% CI: 0.654-0.878, OR = 0.758, P < .001), ureteral access sheath use (95% CI: 1.003-20.725, OR = 4.560, P = .049), and lithotripsy with 30 W laser device (95% CI: 1.304-11.632, OR = 3.895, P = .015; 95% CI: 1.738-17.281, OR = 5.480, P = .004, groups 2 and 3, respectively) were independent factors predicting SFR for RIRS used in 1-2 cm kidney stones. CONCLUSION: The 30 W laser device used in RIRS for 1-2 cm kidney stones had shorter operation times, higher SFRs, and lower post-operative pain scores compared with the 20 W device. The 30 W laser device is safe and more efficient in RIRS for treatment of 1-2 cm kidney stones.


Subject(s)
Kidney Calculi , Lithotripsy , Humans , Kidney Calculi/surgery , Lasers , Prospective Studies , Treatment Outcome
2.
Arch Ital Urol Androl ; 92(2)2020 Jun 24.
Article in English | MEDLINE | ID: mdl-32597122

ABSTRACT

OBJECTIVES: Holmium:Yttrium Aluminum Garnet laser lithotripsy is used in Retrograde Intrarenal Surgery. Fragmentation is made with a certain value of pulse energy (Joule) and frequency (Hertz) in Holmium laser lithotripsy and the multiplication of these values gives us total power (Watt). Devices with maximum power of 20 Watt and 30 Watt are used in clinical practice. We want to compare the efficiency, safety and pain scores of the lithotripsy made below 20 Watt and over 30 Watt with 30 Watt laser device. MATERIALS AND METHODS: 60 patients who had 2-3 cm sized kidney stones and operation planned were prospectively divided into three groups. Groups were random identified. In the first group, fragmentation was performed below 20 Watt power with 20 Watt laser device. In the second group, fragmentation was performed below 20 Watt power with 30 Watt laser device. In the third group, fragmentation was performed over 20 Watt power with 30 Watt laser device. Demographic, stone, intraoperative and postoperative data were recorded. We compared these groups regarding efficiency, safety and pain score. RESULTS: For demographic and stone data, there was a statistically significant difference only for stone number. For intraoperative and postoperative data, there was a statistically significant difference only for ureteral access sheath usage between the groups. Success was lower than the other groups in Group 1. CONCLUSIONS: Success was higher in groups using 30 Watt laser device. There was not statistically significantly difference between complications and pain. 30 Watt laser device is safe and efficient in Retrograde Intrarenal Surgery.


Subject(s)
Kidney Calculi/therapy , Lasers, Solid-State/therapeutic use , Lithotripsy, Laser/methods , Pain, Procedural/diagnosis , Adult , Aged , Female , Fiber Optic Technology , Humans , Lasers, Solid-State/adverse effects , Lithotripsy, Laser/adverse effects , Male , Middle Aged , Pain Measurement , Pain, Procedural/etiology , Prospective Studies , Treatment Outcome , Ureteroscopy/methods
3.
Pacing Clin Electrophysiol ; 27(11): 1540-4, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15546310

ABSTRACT

In spite of a wide choice of pacemakers, there are some problems in making more rational clinical decisions for individual patients since mode selection and programming is usually performed on the basis of a clinical hunch. The aim of this study was to measure the differences in carotid flow in patients with a pacemaker programmed in the dual chamber and in the single chamber pacing modes. Sixty patients with implanted bipolar DDD pacemakers were enrolled in this study. Blood peak systolic velocity (PSV) and end-diastolic velocity (EDV), cross-sectional area, resistive index (RI), and pulsatility index (PI) were measured in the common (CCA), internal (ICA), and external (ECA) carotid arteries before pacemaker implantation and after dual chamber and ventricular pacing at 60 beats/min. PSVs in the left CCA (79.3 +/- 24.9 cm/s) and right CCA (84.1 +/- 18.7) were shown to significantly decrease after VVI pacing (60.1 +/- 16.6 and 62.1 +/- 20.0, respectively). There was also a similar significant decrease in PSV in the left and right ICAs and ECAs. Besides PSV, RI, and PI in the left and right CCAs, ICAs, and ECAs significantly decreased after VVI pacing. There was no similar decrease after DDD pacing. Cross-sectional area and flow volume in the CCA, ICA, and ECA were similar after DDD and VVI pacing and before pacemaker implantation suggesting that cardiac output was similar when the measurements were recorded. Carotid artery PSVs, pulsatility, and RIs were found to be significantly decreased during VVI pacing compared to baseline and DDD pacing. The greater incidence of adverse cerebral outcomes in patients with VVI rather than DDD pacing may be partly due to decreased carotid PSVs.


Subject(s)
Cardiac Pacing, Artificial/methods , Carotid Arteries/physiopathology , Arrhythmia, Sinus/therapy , Blood Flow Velocity/physiology , Blood Pressure/physiology , Blood Volume/physiology , Bradycardia/therapy , Carotid Arteries/diagnostic imaging , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/physiopathology , Carotid Artery, External/diagnostic imaging , Carotid Artery, External/physiopathology , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/physiopathology , Female , Heart Block/therapy , Humans , Male , Middle Aged , Pacemaker, Artificial , Pulsatile Flow/physiology , Regional Blood Flow/physiology , Sick Sinus Syndrome/therapy , Ultrasonography, Doppler, Color , Ultrasonography, Doppler, Duplex , Vascular Resistance/physiology
SELECTION OF CITATIONS
SEARCH DETAIL