Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 101
Filter
1.
Anat Sci Int ; 99(3): 290-304, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38717695

ABSTRACT

This study aimed to describe the shoulder anatomy, together with the anatomical relationships in adults and early stages of development. The shoulder muscles were studied from ultrasound, anatomical, and microscopic perspectives in a sample of 34 human shoulders. Thickness measurements were taken of the tendons and fasciae of the subscapularis, long head tendon of the biceps brachii, supraspinatus, infraspinatus, and teres minor. Ultrasound and dissection techniques are strongly correlated. However, the measurements obtained from the dissection technique were superior to those obtained from the ultrasound in all cases, except for the thickness of the long head tendon of the biceps brachii, the teres minor tendon, and the fascia thickness of the infraspinatus. In addition, the study of shoulder anatomy revealed no differences between females and males. Relevant findings from dissection included a clear overlap between the infraspinatus and supraspinatus, which shared tendon fibers, and a similar connection between the transverse ligament of the long head tendon of the biceps brachii and the subscapularis, which created a more interconnected shoulder function. The study of the anatomical measurements shows an underestimation of the shoulder measurements in the ultrasound compared with the dissection technique, but a high correlation between the measurements made by the two techniques. We present reference values for the tendon and fascia thicknesses of the rotator cuff, with no differences observed by gender. The relationships between shoulder structures described in the anatomical study imply as well that, in the event of an injury, adjacent tissues may be affected. This extended information may facilitate future optimal clinical explorations.


Subject(s)
Shoulder , Tendons , Ultrasonography , Humans , Ultrasonography/methods , Male , Female , Shoulder/anatomy & histology , Shoulder/diagnostic imaging , Tendons/anatomy & histology , Tendons/diagnostic imaging , Rotator Cuff/diagnostic imaging , Rotator Cuff/anatomy & histology , Muscle, Skeletal/anatomy & histology , Muscle, Skeletal/diagnostic imaging , Adult , Dissection , Shoulder Joint/anatomy & histology , Shoulder Joint/diagnostic imaging , Middle Aged , Aged
2.
Life (Basel) ; 14(5)2024 May 15.
Article in English | MEDLINE | ID: mdl-38792649

ABSTRACT

The semimembranosus muscle inserts into several tendons that are associated with some pathologies. Although ultrasound is useful for studying, diagnosing, and managing these pathologies, the correct interpretation of any images requires a clear knowledge of the related anatomical structures and the inter-related functions. We studied 38 cryopreserved non-paired knees from adult anatomical specimens and 4 non-paired knees from 29 to 38-week-old fetuses. The semimembranosus muscle and its tendons were located, observed, and injected under ultrasound guidance. The macroscopic anatomy was studied using dissection and anatomical cuts and the tendons were analyzed histologically. Measurements of muscle were taken 10 cm from the medial epicondyle and just before the tendon divided. The ultrasound facilitated the identification of the different divisions of the tendon of semimembranosus muscle and the rotation of the muscle and tendon from medial to posterior. An anatomical study confirmed this rotation and revealed an average width, thickness, and diameter of 38.29 mm, 14.36 mm, and 112.64 mm, respectively. Important relationships were observed between the divisions of the main tendons and the medial collateral ligament, the posterior side of the knee and popliteus muscle. This information can help to explain knee pathologies and facilitate rehabilitation after surgery.

3.
J Pers Med ; 14(5)2024 May 17.
Article in English | MEDLINE | ID: mdl-38793118

ABSTRACT

(1) Background: Breast reduction is one of the most frequently performed plastic surgeries in women worldwide. The Wise pattern breast reduction is one of the most frequent skin designs for this surgery. One key point of the surgery is to preserve a well-vascularized NAC by using different surgical pedicles. This study aims to test and update the anatomical knowledge of breast vascularization, the topographic and anatomical basis of the different surgical vascular pedicles, and the differences between the right and left sides. (2) Methods: A descriptive observational anatomical study was carried out on 15 breasts from 10 cryopreserved body donors. A dissection was performed by quadrants to know the affected arteries' origin in the different patterns. (3) Results: The largest and most frequently dissected internal mammary perforator artery was in the second intercostal space. A total of 44.9% of the dissected perforators are located in the upper inner quadrant, compared to 53.5% in the lower quadrants. (4) Conclusions: The upper inner quadrant alone has the most arterial perforators. In contrast, the sum of the two lower quadrants represents the greatest vascularization of the breast, with a small difference between both.

4.
Healthcare (Basel) ; 12(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38786411

ABSTRACT

BACKGROUND: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. OBJECTIVE: We compared the accuracy and safety of ultrasound-guided versus palpation-guided procedures for the proper targeting of the interface between the plantar fascia and the flexor digitorum brevis with a solid needle. METHODS: A crossover cadaveric study was conducted. Five experienced therapists performed a series of 20 needle insertions each (n = 100 in total, 10 landmark-guided and 10 ultrasound-guided) on 10 anatomical samples. The therapists were instructed to accurately place the needle on the interface between the plantar fascia and the flexor digitorum brevis muscle. The distance of the tip of the needle to the identified target (accuracy), the surrounding sensitive structures targeted (safety), the time needed for the procedure, the number of needle passes, and the needle length outside the skin were assessed. RESULTS: The ultrasound-guided technique was associated with a significantly higher accuracy (p < 0.001) but without differences in safety (p = 0.249) as compared to the palpation-guided procedure. CONCLUSION: Our results suggest that ultrasound-guided insertion exhibits greater accuracy but not greater safety than palpation-guided insertion when targeting the interface between the plantar fascia and the flexor digitorum brevis.

5.
J Orthop Res ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38598304

ABSTRACT

The aim of this study was to evaluate the effectiveness of a focal vibration protocol added to an activation protocol with active muscle contractions and to see what repercussions it has on sprint, countermovement jump (CMJ), and lower limb isometric strength. A double-blind randomized clinical trial was conducted in the Functional Anatomy Laboratory and the sample consisted of 70 athletes. The main outcome measures were knee extension force, CMJ, sprint, and surface electromyography. Repeated-measures analysis of variance revealed significant improvements. They were found in the within-group analysis for the Experimental Group in the isometric extension force (p < 0.001; η2 = 0.368), CMJ (p < 0.001; η2 = 0.301) and 30 m sprint (p < 0.001; η2 = 0.376). In the electromyography, there are changes in the Sham Group in all muscles, in CMJ and Sprint tests, and no differences in the Experimental Group, except for the RF muscle. In the between-group analysis, statistically significant differences were found only in favor of the Experimental Group in CMJ (p = 0.017; η2 = 0.81) and 30 m sprint (p < 0.001; η2 = 0.152). These results confirm a significant improvement in the sprint, CMJ performance, and quadriceps strength, after a focal vibration protocol, added to a muscle active contraction, compared to a focal vibration sham protocol. Therefore, our results suggest that the focal vibration can be a very useful tool in sports involving high-powered actions.

6.
J Clin Med ; 13(5)2024 Feb 25.
Article in English | MEDLINE | ID: mdl-38592139

ABSTRACT

(1) Background: The aging population is expected to triple by 2050. Executive functions decline with age, impacting daily tasks, and this is associated with neurodegenerative diseases. Aerobic and resistance exercises positively affect cognitive function in older adults by influencing growth markers. However, the modalities of exercise and the optimal parameters for maximum cognitive benefits remain unclear. (2) Methods: A meta-analysis of randomized clinical trials (RCTs) was conducted. The systematic search was on slowing cognitive decline and performed in the PubMed/MEDLINE and Cochrane Library databases. Articles were included if participants were ≥65 years, healthy, and performing resistance or aerobic exercise, and they were excluded if there was a combination of training and if they have neurological disease or cognitive impairment. (3) Results: The search strategy found a total of 1635 studies. After removing duplicates and assessing the inclusion and exclusion criteria, eight articles were included in the meta-analysis, with a total of 463 healthy older adults analyzed. No significant differences between the intervention groups and the control groups after the aerobic or resistance programs were found. (4) Conclusions: Aerobic exercise interventions improved executive function more than resistance training in older adults, but without statistically significant differences. This can serve as a guide to see, with caution, whether we need a multidisciplinary approach to be more effective in improving the cortical health of older adults.

7.
Bioengineering (Basel) ; 11(2)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38391591

ABSTRACT

BACKGROUND: Gait is the manner or style of walking, involving motor control and coordination to adapt to the surrounding environment. Knowing the kinesthetic markers of normal gait is essential for the diagnosis of certain pathologies or the generation of intelligent ortho-prostheses for the treatment or prevention of gait disorders. The aim of the present study was to identify the key features of normal human gait using inertial unit (IMU) recordings in a walking test. METHODS: Gait analysis was conducted on 32 healthy participants (age range 19-29 years) at speeds of 2 km/h and 4 km/h using a treadmill. Dynamic data were obtained using a microcontroller (Arduino Nano 33 BLE Sense Rev2) with IMU sensors (BMI270). The collected data were processed and analyzed using a custom script (MATLAB 2022b), including the labeling of the four relevant gait phases and events (Stance, Toe-Off, Swing, and Heel Strike), computation of statistical features (64 features), and application of machine learning techniques for classification (8 classifiers). RESULTS: Spider plot analysis revealed significant differences in the four events created by the most relevant statistical features. Among the different classifiers tested, the Support Vector Machine (SVM) model using a Cubic kernel achieved an accuracy rate of 92.4% when differentiating between gait events using the computed statistical features. CONCLUSIONS: This study identifies the optimal features of acceleration and gyroscope data during normal gait. The findings suggest potential applications for injury prevention and performance optimization in individuals engaged in activities involving normal gait. The creation of spider plots is proposed to obtain a personalised fingerprint of each patient's gait fingerprint that could be used as a diagnostic tool. A deviation from a normal gait pattern can be used to identify human gait disorders. Moving forward, this information has potential for use in clinical applications in the diagnosis of gait-related disorders and developing novel orthoses and prosthetics to prevent falls and ankle sprains.

8.
J Sport Rehabil ; 33(3): 166-173, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38340711

ABSTRACT

CONTEXT: Anterior cruciate ligament injuries are directly related to the control of dynamic knee valgus in the landing of a jump, and this is mainly due to the correct activation and neuromuscular function of the lower-extremity muscles. The aim of the study is to assess the relationship between lower limb muscle activity during a single-legged drop jump and knee frontal plane projection angle (FPPA). DESIGN: A correlation study. METHODS: Thirty healthy collegiate female athletes were included in the study. Main outcomes measures were peak knee FPPA and muscle activity (% of maximal voluntary isometric contraction). Peak knee FPPA during a single-legged drop jump test was identified using a 2-dimensional motion analysis system. Muscle activity was assessed using a surface electromyograph for gluteus maximus, gluteus medius, biceps femoris, semitendinosus, vastus medialis quadriceps, vastus lateralis quadriceps, medial gastrocnemius, and lateral gastrocnemius. All variables were assessed for both dominant and nondominant limbs. A correlation analysis between peak knee FPPA and muscle activity was performed. Statistical significance was set at P <.05. RESULTS: A mean peak knee FPPA of 14.52° and 13.38° was identified for dominant and nondominant limb single-legged drop jump test, respectively. Muscle activity (% of maximal voluntary isometric contraction) for muscles assessed ranged from 43.97% to 195.71% during the single-legged drop jump test. The correlation analysis found no significant correlation between any of the muscles assessed and peak knee FPPA during the single-legged drop jump test (Pearson coefficient between -.3 and .1). CONCLUSIONS: There is no association between muscle activity from the lower limb muscles and the knee FPPA during a single-legged drop jump in female athletes. Thus, different muscle properties should be assessed in order to understand such an important movement as the knee FPPA during a jump.


Subject(s)
Knee Joint , Knee , Female , Humans , Knee Joint/physiology , Quadriceps Muscle , Athletes , Buttocks
9.
Article in English | MEDLINE | ID: mdl-38261788

ABSTRACT

OBJECTIVE: To evaluate the effect of minimally invasive ultrasound-guided fascial release and a foot orthoses with first metatarsal head cut-out on the biomechanics of the medial longitudinal arch of the foot in cadaveric specimens. DESIGN: A cross-sectional study was designed (20 body-donors). Anthropometric measurements of the foot, foot posture index and the windlass test and force were measured in different conditions: unloaded, loaded position, with foot orthoses, after a 25% plantar fascia release and after a 50% release. RESULTS: For the anthropometric measurements of the foot, differences were found in foot length (p = 0.009), arch height (p < 0.001) and midfoot width (p = 0.019) when comparing the unloaded vs foot orthoses condition. When foot orthoses were compared with 25% plantar fascial release, differences were found in foot length (p = 0.014) and arch height (p < 0.001). In the comparation with 50% plantar fascial release, differences were found in the arch height (p < 0.001). A significant interaction between foot orthoses condition and grades was found in the arch height during the windlass test (p = 0.021). CONCLUSION: The results indicate that the presence of foot orthoses leads to a significant increase in arch height compared to other conditions. Furthermore, when plantar fascia release is performed, the arch does not exhibit any signs of collapse.

10.
Sports (Basel) ; 12(1)2024 Jan 22.
Article in English | MEDLINE | ID: mdl-38275985

ABSTRACT

Generating large mechanical power during actions such as sprinting or jumping is a crucial factor in many sports. These types of actions require a good warm-up activation. Capacitive-Resistive Electric Transfer (CRET) is a non-invasive therapy based on the application of radio frequency electric currents within the range of 300 kHz-1.2 MHz to accelerate tissue metabolic activity. This study aimed to evaluate the effectiveness of adding CRET to an active warm-up protocol in young adult athletes. For the double-blind randomized clinical trial, 60 healthy athletes were recruited and divided into an Experimental group (EG) and a Sham group (SG). EG received a CRET protocol in addition to an active warm-up. SG carried out the same warm-up but with a placebo CRET. The main outcome measures were isometric extension force, countermovement-jump (CMJ), 30 m-sprint test, and surface electromyography (sEMG). There is no statistically significant interaction (group-time) for any of the variables studied. Significant main effects for time were found in isometric extension force (p = 0.008); 30 m sprint (p = 0.017); rectus femoris sEMG during CMJ (p = 0.002); vastus lateralis sEMG during CMJ (p = 0.012); vastus medialis during CMJ (p = 0.010) and rectus femoris sEMG during the 30 m sprint test (p = 0.012). Non-significant differences between means are observed in the isometric extension force (48.91 EG; 10.87 SG) and 30 m sprint (-0.13 EG; -0.04 SG) variables. To conclude, a non-significant tendency was observed in sprint and quadriceps strength following CRET therapy, compared to the individuals' pre-treatment state. Future research should use more treatment sessions to observe this tendency.

11.
J Orthop Res ; 42(2): 317-325, 2024 02.
Article in English | MEDLINE | ID: mdl-37593805

ABSTRACT

The aim of this study was to evaluate the muscle activation of the vastus medialis, vastus lateralis, and gluteus medius during different strength and stability exercises with a water tank compared with a sandbag. A cross-sectional study was conducted in the Functional Anatomy Laboratory, and the sample consisted of 28 athletes. The main outcome measures were surface electromyography (dependent variable), water tank and sandbag, and exercise type (independent variables): Isometric Single Leg Stance (ISLS), One Leg Deadlift (OLDL), Front Rack Forward Lunge (FRFL), and Lateral Lunge (LL). Repeated measures analysis of variance (ANOVA) revealed a significant Group × Time interaction in gluteus medius root mean square (RMS) (F = 14.198, p < 0.001, ŋ2 = 0.35), vastus lateralis RMS (F = 24.374, p < 0.001, ŋ2 = 0.47), and vastus medialis RMS (F = 27.261, p < 0.001, ŋ2 = 0.50). In the between-group analysis, statistically significant differences were observed in gluteus medius RMS in the ISLS: 28.5 ± 15.8 water tank and 20.8 ± 12.6 sandbag (p < 0.001, ŋ2 = 0.08) and OLDL: 29.7 ± 13.3 water tank and 26.5 ± 13.1 sandbag (p < 0.001, ŋ2 = 0.01). In vastus lateralis in ISLS: 30.4 ± 37.6 water tank and 19.0 ± 26.7 sandbag (p < 0.001, ŋ2 = 0.03). In vastus medialis in ISLS: 14.2 ± 13.0 water tank and 7.0 ± 5.6 sandbag (p < 0.001, ŋ2 = 0.12), OLDL: 21.5 ± 16.9 water tank and 15.5 ± 10.7 sandbag (p = 0.002, ŋ2 = 0.04), and LL: 51.8 ± 29.6 water tank and 54.3 ± 29.3 sandbag (p = 0.017, ŋ2 = 0.00). These results confirm significantly greater activation of the gluteus medius and vastus medialis in the ISLS and OLDL exercises, and of the vastus lateralis in the water tank ISLS exercise. However, the vastus medialis shows greater activation in the LL exercise.


Subject(s)
Muscle, Skeletal , Quadriceps Muscle , Humans , Quadriceps Muscle/physiology , Cross-Sectional Studies , Muscle, Skeletal/physiology , Athletes , Water
12.
Int J Legal Med ; 138(3): 1165-1171, 2024 May.
Article in English | MEDLINE | ID: mdl-38112757

ABSTRACT

Head trauma is frequently related to the misuse of drinking vessels as weapons. Forensic reports usually evaluate these blunt injuries as having occurred in scenarios where the alcohol intake is high. Fatal consequences are seen in blows with glass bottles aiming at the head. To prove the outcome that a glass bottle thrown to the head could cause, three intact human cadaver heads were impacted with 1-liter glass bottles at 9.5 m/s using a drop-tower. The impact location covered the left temporal bone, sphenoid bone, and zygomatic arch. The contact between the head and the bottle was produced at an angle of 90° with (1) the valve of the bottle, (2) the bottom of the bottle, and (3) with the head rotated 20° in the frontal plane touching again with the bottom of the bottle. The three bottles remained intact after the impact, and the injury outcomes were determined by computed tomography (CT). The alterations were highly dependent on the impact orientation. The outcome varied from no injury to severe bone fractures. In the most injurious case (#3), fractures were identified in the cranial base, sphenoid bone, and zygomatic bone. These testing conditions were selected to replicate one specific legal case, as required by the plaintiff. Physical disputes with bar glassware can lead to complex combinations of blunt and sharp-force injuries. Controlled biomechanical studies can benefit forensic analyses of violence involving glassware by providing a better understanding of the underlying injury mechanisms.


Subject(s)
Skull Fractures , Wounds, Nonpenetrating , Humans , Temporal Bone , Violence , Cadaver
13.
Biomedicines ; 11(11)2023 Nov 04.
Article in English | MEDLINE | ID: mdl-38001972

ABSTRACT

BACKGROUND: The aim of this study was to assess changes in muscle properties after a single session of capacitive and resistive energetic transfer (TECAR) therapy on spastic gastrocnemius and quadriceps muscles in chronic post-stroke. METHODS: A total of 36 chronic stroke survivors with lower limb hypertonia were enrolled in a double-blind randomized controlled trial. The experimental group (n = 18) received a single 30 min session of TECAR therapy in combination with functional massage (FM) on the gastrocnemius and quadriceps muscles. The control group (n = 18) received a sham treatment of TECAR therapy (without electrical stimulation) in combination with real FM. The primary outcome was muscle tone of the lower limb muscles assessed with the Modified Ashworth Scale (MAS). The secondary outcomes were goniometric degrees of the MAS (goniometer), neuromuscular properties of the gastrocnemius/quadriceps (myotonometer), and passive range of motion (inclinometer). All measurements were performed at baseline (T0), immediately after treatment (T1), and at 30 min post-treatment (T2) by a blinded assessor. RESULTS: The MAS score ankle dorsiflexion significantly decreased at T0-T1 (p = 0.046), and the change was maintained at T0-T2 (p = 0.019) in the experimental group. Significant improvements were noted in the passive range of motion for knee flexion (p = 0.012) and ankle dorsiflexion (p = 0.034) at T2. In addition, knee flexion improved at T1 (p = 0.019). CONCLUSION: A single session of Tecar therapy at the same time with FM on the gastrocnemius and rectus femoris immediately reduces muscle tone and increases the passive range of motion of both ankle and knee in chronic stroke survivors. There were no significant changes in the neuromuscular properties measured with myotonometer.

14.
Life (Basel) ; 13(10)2023 Oct 15.
Article in English | MEDLINE | ID: mdl-37895441

ABSTRACT

For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of ultrasound-guided and palpation-guided needling techniques for the patellar tendon. A total of five physical therapists performed a series of 20 needle insertion task each (n = 100), 10 insertions based on manual palpation (n = 50) and 10 insertions guided with ultrasound (n = 50) to place a needle along the interface between the patellar tendon and Hoffa's fat pad. All procedures were performed on cryopreserved knee specimens. Distance to the targeted tissue, time of the procedure, accurate rate of insertions, number of passes, and unintentional punctured structures between both applications (with and without ultrasound guiding) were compared. The results revealed higher accuracy (100% vs. 80%), a lower distance from needle to the targeted tissue (0.25 ± 0.65 vs. 2.5 ± 1.9 mm), longer surface of contact with the needle (15.5 ± 6.65 vs. 4.7 ± 7.5 mm), and a lower frequency of patellar tendon puncture (16% vs. 52%, p < 0.001) with the ultrasound-guided procedure as opposed to palpation-guided one. Nevertheless, the ultrasound-guided procedure took longer (54.8 ± 26.8 vs. 23.75 ± 15.4 s) and required more passes (2.55 ± 1.9 vs. 1.5 ± 0.95) to be conducted than the palpation-guided procedure (all, p < 0.001). According to these findings, the accuracy of invasive procedures applied on the patellar tendon is higher when conducted with ultrasound guidance than when conducted just on manual palpation or anatomical landmark. These results suggest that ultrasound could improve the clinical application of invasive procedures at the fat-patellar tendon interface. Due to the anatomical features of the targeted tissue, some procedures require this precision, so the use of ultrasound is recommended.

15.
J Clin Med ; 12(17)2023 Aug 26.
Article in English | MEDLINE | ID: mdl-37685627

ABSTRACT

BACKGROUND: With the increasing number of older adults and their declining motor and cognitive function, it is crucial to find alternative methods for assessing physical functionality. The Short Physical Performance Battery (SPPB), the Time Up and Go (TUG) test, the 4 Meter Walk Test and the Barthel Index (BI) have been used to evaluate mobility and fragility and predict falls. But some of these functional test tasks could be difficult to perform for frail older adults or bedridden patients that cannot ambulate. This study aimed to evaluate the relationship between these functional tests and the power elbow flexion (PEF test). MATERIAL AND METHODS: A correlation study was designed with 41 older adults over 65 years of age. The upper limb muscle power was measured using a linear encoder (VITRUBE VBT) with the flexion of the elbow. RESULTS: Strong correlations were found between the PEF test and the 4mWT (rho = 0.715, p = 0.001) and TUG (rho= -0.768, p = 0.001), indicating that the greater the upper limb muscle power is, the greater physical performance will be. Moderate correlations were also found between the PEF and Barthel Index (rho = 0.495, p = 0.001) and SPPB (rho = 0.650, p < 0.001). CONCLUSIONS: There is a strong correlation between PEF and the functional tests, proving that older adults that have greater upper limb muscle power have better physical performance. Upper limb muscle power and PEF could be an interesting tool for the assessment of physical performance in bedridden older adults.

16.
Healthcare (Basel) ; 11(15)2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37570409

ABSTRACT

BACKGROUND: To examine the correlation between physical performance and muscle strength and the variables obtained from tensiomyography and myotonometry. METHODS: Fifty-two older adults able to complete functional tests participated in this observational study. Variables of maximal radial muscle displacement (Dm) and contraction time (Tc) (using tensiomyography) and muscle stiffness (using myotonometry) of the rectus femoris and vastus lateralis muscles were assessed. Physical performance (Short Physical Performance Battery, Timed Up and Go, Five Times Sit to Stand, and walking speed), isometric knee extension strength, and grip strength were assessed. A correlation analysis was performed between all the variables. RESULTS: A significant correlation between the Short Physical Performance Battery and the rectus femoris (rho = 0.491) and vastus lateralis Dm (rho = 0.329) was found. Significant correlations between the Five Times Sit to Stand Test and the Dm values of the rectus femoris (rho = -0.340) and Dm (rho = -0.304), and stiffness (rho = -0.345) in the vastus lateralis, were also found. No significant correlations were found between tensiomyography and myotonometry, the Timed Up and Go, and walking speed, nor between tensiomyography and myotonometry and grip strength or isometric knee extension strength. CONCLUSIONS: Functional tests should be prioritized in the assessment of older adults, but further research into muscle quality using technology is advisable.

17.
Healthcare (Basel) ; 11(13)2023 Jun 22.
Article in English | MEDLINE | ID: mdl-37444663

ABSTRACT

BACKGROUND: Glenohumeral lateral distraction mobilisation (GLDM) is used in patients with shoulder mobility dysfunction. No one has examined the effect of scapular fixation during GLDM. The aim was to measure and compare the lateral movement of the humeral head and the rotational movement of the scapula when three different magnitudes of forces were applied during GLDM, with and without scapular fixation. METHODS: Seventeen volunteers were recruited (n = 25 shoulders). Three magnitudes of GLDM force (low, medium, and high) were applied under fixation and non-fixation scapular conditions in the open-packed position. Lateral movement of the humeral head was assessed with ultrasound, and a universal goniometer assessed scapular rotation. RESULTS: The most significant increase in the distance between the coracoid and the humeral head occurred in the scapular fixation condition at all three high-force magnitudes (3.72 mm; p < 0.001). More significant scapular rotation was observed in the non-scapular fixation condition (12.71°). A difference in scapula rotation (10.1°) was observed between scapular fixation and non-scapular fixation during high-force application. CONCLUSIONS: Scapular fixation resulted in more significant lateral movement of the humeral head than in the non-scapular fixation condition during three intensities of GLDM forces. The scapular position did not change during GLDM with the scapular fixation condition.

18.
Healthcare (Basel) ; 11(11)2023 May 30.
Article in English | MEDLINE | ID: mdl-37297743

ABSTRACT

Percutaneous electrical stimulation has been performed for years with only the assistance of anatomical landmarks. The development of real-time ultrasonography guidance has improved the precision and safety of these percutaneous interventions. Despite ultrasound-guided and palpation-guided procedures being performed routinely for targeting nerve tissues in the upper extremity, the precision and safety of these techniques are unknown. The aim of this cadaveric study was to determine and compare the precision and safety of ultrasound-guided versus palpation-guided needling procedure with and without the handpiece of the ulnar nerve on a cadaveric model. Five physical therapists performed a series of 20 needle insertion tasks each (n = 100), 10 palpation-guided (n = 50) and 10 ultrasound-guided (n = 50) on cryopreserved specimens. The purpose of the procedure was to place the needle in proximity to the ulnar nerve at the cubital tunnel. The distance to target, time performance, accurate rate, number of passes, and unintentional puncture of surrounding structures were compared. The ultrasound-guided procedure was associated with higher accuracy (66% vs. 96%), lower distance from needle to the target (0.48 ± 1.37 vs. 2.01 ± 2.41 mm), and a lower frequency of perineurium puncture (0% vs. 20%) when compared with the palpation-guided procedure. However, the ultrasound-guided procedure required more time (38.33 ± 23.19 vs. 24.57 ± 17.84 s) than the palpation-guided procedure (all, p < 0.001). Our results support the assumption that ultrasound guidance improves the accuracy of needling procedures on the ulnar nerve at the cubital tunnel when compared with palpation guidance.

19.
Life (Basel) ; 13(5)2023 May 16.
Article in English | MEDLINE | ID: mdl-37240838

ABSTRACT

(1) Background: aging is associated with functional changes such as balance, which plays a critical role in older adults. Physical exercise has been established as a factor capable of modulating these age-related alterations. (2) Methods: a meta-analysis of randomized clinical trials (RCTs) was conducted. The systematic search was performed in the PubMed/MEDLINE, Web of Science, the SPORTDiscus and Cochrane Library databases. Articles were included if participants were 65 years or older, healthy and performing resistance training, aerobic training, balance training or multicomponent training. Studies were excluded if there was a combination of training with other types of intervention. The protocol of this systematic review was published in the International Prospective Register of Systematic Reviews (PROSPERO) with the code CRD42021233252 (3) Results: the search strategy found a total of 1103 studies. After removing duplicates and the inclusion and exclusion criteria, eight articles were included in the meta-analysis, with a total of 335 healthy older adults analyzed. The results showed no significant differences between the intervention groups and the control groups after the exercise programs. (4) Conclusions: interventions based on different types of exercise improved static balance in elderly population, but without statistically significant difference in comparison with the control groups.

20.
Am J Phys Med Rehabil ; 102(12): 1091-1096, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37205741

ABSTRACT

OBJECTIVES: The aims of the study are to analyze and describe the accuracy of an ultrasound-guided approach to target the L5 root in cadaveric specimens and evaluate whether gender differences exist. DESIGN: A cross-anatomical study on 40 cadaver L5 nerve roots was performed. A needle was introduced until contacting the L5 nerve root using ultrasound guidance. After that, specimens were frozen and studied by a cross-anatomical view to see the needle's path. The angulation, length, distance from the vertebral spine, the relevant ultrasound anatomical references, and the accuracy of the procedure were evaluated. RESULTS: The needle tip reached the L5 root at a 72.5% rate. The mean angulation degrees of the needle relative to the skin surface were 75.53 ± 10.17 degrees, the length of the needle inserted was 5.83 ± 0.82 cm, and the distance from the vertebral spine to the point of entry of the needle was 5.39 ± 1.44 cm. CONCLUSIONS: An ultrasound-guided technique can potentially be an accurate technique to perform invasive procedures on the L5 root. There were statistically significant differences between males and females in the length of the needle introduced. If the L5 root is not clearly visualized, ultrasound will not be the technique of choice.


Subject(s)
Lumbar Vertebrae , Spinal Nerve Roots , Male , Female , Humans , Spinal Nerve Roots/diagnostic imaging , Ultrasonography , Lumbar Vertebrae/diagnostic imaging , Ultrasonography, Interventional/methods , Cadaver
SELECTION OF CITATIONS
SEARCH DETAIL
...