ABSTRACT
Objective: Describe our experience in the surgical treatment of transverse with posterior wall fractures of the acetabulum, the elements that help in the choice of the approach and functional and radiological results of this type of injury. Methods: We retrospectively evaluated 9 patients (9 fractures) with transverse and posterior wall fractures operated between August 2008 and September 2010. Six patients were men and 3 women with an average age of 40.4 years. We reviewed the surgical protocols, the perioperative data and the pre and post operative radiological images. We registered the complications and the functional results with the Merle DAubigne and Postel score. Results: All cases were considered secondary to high energy mechanisms. Five patients had posterior dislocation of the hip and 4 had central dislocation. Eight patients had associated injuries. In the early postoperative period there were no complications. One patient had posttraumatic osteoarthritis and required total hip arthroplasty. The average of Merle dAubigne score was 16.1 points. Conclusion: Surgical treatment for this type of injury had good results in this group of patients.
Objetivo: Describir nuestra experiencia en el tratamiento quirúrgico de las fracturas transversas más pared posterior de acetábulo, los elementos que ayudan en la elección del abordaje y los resultados funcionales y radiológicos de este tipo de lesiones. Material y Métodos: Estudio retrospectivo y descriptivo de una serie consecutiva de 9 pacientes (9 fracturas) operados de una fractura transversa más pared posterior de acetábulo entre agosto de 2008 y septiembre de 2010. Seis hombres y 3 mujeres con una mediana de edad de 40,4 años se operaron en este período. Se revisaron los protocolos operatorios, las fi chas clínicas y las imágenes pre y postoperatorias. Se evaluaron las complicaciones tempranas y tardías y los resultados funcionales de acuerdo a la escala de Merle DAubigne y Postel a un seguimiento promedio de 17 meses. Resultados: Todos los casos se consideraron secundarios a mecanismos de alta energía. Cinco pacientes presentaron luxación posterior de cadera y 4 presentaron luxación central. Ocho pacientes presentaron lesiones asociadas. En el postoperatorio temprano no se presentaron complicaciones. Un paciente presentó artrosis post traumática y requirió artroplastía total de cadera. El puntaje promedio de Merle dAubigne fue de 16,1 puntos. Conclusión: El tratamiento quirúrgico para este tipo de lesiones tiene buenos resultados en el corto plazo en este grupo de pacientes.
Subject(s)
Humans , Male , Adult , Female , Acetabulum/surgery , Acetabulum/injuries , Fractures, Bone/surgery , Acetabulum , Fractures, Bone , Patient Satisfaction , Postoperative Complications , Recovery of Function , Retrospective Studies , Treatment OutcomeABSTRACT
Percutaneous iliosacral screw fixation is a useful technique for fixation of posterior pelvis ring injuries but it has potential complications. We describe a surgical technique modification of the original technique described by Routt etal. Using the surface of the C-arm as a guide in the inlet and outlet views, exact positioning of the guide wire is easier and surgical time as radiation exposure are decreased. We hope that this modification, in addition to a better understanding of sacral anatomical variations and risk factors for misplacement of iliosacral screws would reduce complications related to this procedure.
La fijación percutánea con tornillos sacroilíacos es una técnica de utilidad demostrada para la fijación de las fracturas de la pelvis posterior, sin embargo, no está exenta de riesgos. Describimos una modificación de la técnica quirúrgica original descrita por Routt et al. Utilizando las superficies del fluoroscopio como referencia en las vistas inlet y outlet, se facilita la orientación de la aguja guía disminuyendo el tiempo operatorio y el tiempo de radiación necesaria para la colocación de este tipo de osteosíntesis. Esperamos que esta modificación, asociado a un mejor conocimiento de la anatomía del sacro y los factores asociados a mal posición de los tornillos sacroilíacos permita disminuir los riesgos asociados a este procedimiento.
Subject(s)
Humans , Bone Screws , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Pelvic Bones/injuries , Fluoroscopy , Ileum/surgery , Ileum/injuries , Models, Biological , Sacrum/surgery , Sacrum/injuriesABSTRACT
Introduction: External fixation is a useful technique for the treatment of instable pelvic fractures. There are several configuration alternatives regarding to Schanz pin placement. In order to assure safe placement of the Shanz pins, it is useful to obtain an intraoperative fluoroscopic image of the supra-acetabular teardrop, wich indicates the linear osseous path between the anterior inferior iliac spine (AIIS) and the posterior superior iliac spine (PSIS). Material and Method: The surgical technique for safe supra-acetabular pin placement is described using an anatomic piece corresponding to the pelvis of a middle-aged male. A combination of outlet and obturador projections is sued to show an adequate fluoroscopic vision of the supra-acetabular teardrop. The result of this technique is demonstrated with a case report. Results: Having achieved a proper intraoperative vision of the supra-acetabular teardrop, the Schanz pins can be safely placed from the anterior inferior iliac spine (AIIS) through the osseous corridor in order to reach the posterior superior iliac spine (PSIS). Conclusions: Placing both Schanz pins in the supra-acetabular area and guided under fluoroscopic vision as described in this technique, allows reaching the posterior pelvis, achieving better control of bone fragments and compression of the posterior pelvic ring through an anterior approach. Therefore, this technique is an excellent alternative for external fixation of an unstable pelvic fracture.
Introducción: La fijación externa es de gran utilidad para el tratamiento de fracturas inestables de pelvis. Existen diversas opciones de configuración y alternativas para la colocación de los fijadores externos. Para la colocación segura de estas agujas de Schanz, la imagen fluoroscópica intra operatoria de la lágrima supra-acetabular, que indica el trayecto lineal entre la espina ilíaca antero inferior (EIAI) y la espina ilíaca postero superior (EIPS), resulta de gran utilidad. Material y Método: Se describe la técnica para la colocación de estas agujas en una pieza anatómica bajo visión fluoroscópica y cómo obtener una adecuada visión de la lágrima supra-acetabular al colocar el aparato de rayos en outlet-obsturatriz. Además se muestra el resultado de esta técnica en un caso clínico. Resultados: Obteniendo una adecuada visión intra-operatoria de la lágrima supra-acetabular se pueden colocar agujas de Schanz o cualquier material de osteosíntesis desde la espina ilíaca antero inferior hasta la espina ilíaca postero superior a través de un corredor óseo supra-acetabular. Conclusiones: Las agujas de Schanz colocadas en la zona supra-acetabular bajo control de rayos con la técnica aquí descrita permiten alcanzar la zona posterior de la pelvis (EIPS), logrando un mejor control de los fragmentos óseos y permitiendo la compresión desde anterior de la pelvis posterior. Son por lo tanto una excelente alternativa al momento de decidir una fijación externa de fracturas inestables de pelvis.
Subject(s)
Humans , External Fixators , Fracture Fixation/instrumentation , Fractures, Bone/surgery , Pelvic Bones/surgery , Pelvic Bones/injuries , Acetabulum , Fracture Fixation/methodsABSTRACT
We report two cases of hemodynamic instability secondary to stable pelvic fractures. Both patients had isolated arterial lesions with large pelvic hematomas. In the two cases embolization of the injured vessel was performed. Knowing the existence of this kind of traumatic lesion is crucial for early diagnosis improving the results in the treatment of this life-threatening condition. Patients with pelvic fractures should be under observation for long periods of time, because delayed hemorrhage can occur.
Presentamos dos casos de inestabilidad hemodinámica en pacientes con fracturas de pelvis que fueron consideradas estables. Los pacientes presentaban lesión arterial traumática aislada y hematoma para-vesical de gran tamaño. Ambos fueron tratados de manera exitosa mediante embolización de su lesión arterial. Conocer este tipo de lesiones y diagnosticarlas de manera oportuna son claves en el buen resultado clínico de una lesión potencialmente mortal pero frecuentemente subvalorada. Es aconsejable observar por períodos prolongados de tiempo a pacientes con fracturas de pelvis ya que pueden producirse sangrados tardíos.