Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Occup Environ Hyg ; 18(2): 43-50, 2021 02.
Article in English | MEDLINE | ID: mdl-33357045

ABSTRACT

The main objective was to determine the decontamination efficacy of quaternary ammonium, 0.1% sodium hypochlorite, and water after deliberate contamination with four antineoplastics (ifosfamide, 5-fluorouracil, irinotecan, methotrexate). A stainless-steel surface was deliberately contaminated with ifosfamide (15 µg), 5-fluorouracil (10 µg), irinotecan (1 µg), and methotrexate (1 µg). First, a single decontamination step with either water, quaternary ammonium, or 0.1% sodium hypochlorite was tested. Then, the effect of up to four successive decontamination steps with either quaternary ammonium or 0.1% sodium hypochlorite was tested. Commercial wipes consisting of two layers of non-woven microfibers with an inner layer of highly absorbent viscose fibers were used. Triplicate surface samples were obtained and tested by ultra-performance liquid chromatography tandem mass spectrometry. The limits of detection were 0.004 ng/cm2 for ifosfamide, 0.040 ng/cm2 for 5-fluorouracil, 0.003 ng/cm2 for irinotecan, and 0.002 ng/cm2 for methotrexate. After a single decontamination step, the 0.1% sodium hypochlorite eliminated 100% of contamination with 5-fluorouracil, irinotecan, and methotrexate and 99.6 ± 0.5% of ifosfamide contamination. Quaternary ammonium and water also removed 100% of the 5-fluorouracil, and 99.5% to 99.9% of the other three antineoplastics. For ifosfamide, irinotecan, and methotrexate, the decontamination efficacy increased with successive decontamination steps with quaternary ammonium. 5-fluorouracil was undetectable after a single decontamination step. Methotrexate was the only drug for which decontamination efficacy was less than 100% after four decontamination steps. 100% decontamination efficacy was achieved from the decontamination step with 0.1% sodium hypochlorite for 5-fluorouracil, irinotecan, and methotrexate. For ifosfamide, 100% efficacy was achieved only after the third decontamination step. It was possible to make all traces of antineoplastic undetectable after deliberate contamination with 5-fluorouracil, irinotecan, and methotrexate with a 0.1% chlorine solution; up to three decontamination steps were needed to make ifosfamide undetectable. Water or quaternary ammonium removed more than 99.5% of deliberate contamination. In several scenarios, it was necessary to repeat the decontamination to eliminate residual traces. More work is needed to identify the optimal decontamination approach for all of the antineoplastic drugs used.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Decontamination , Equipment Contamination/prevention & control , Fluorouracil/analysis , Ifosfamide/analysis , Irinotecan , Methotrexate/analysis , Occupational Exposure/analysis
2.
J Oncol Pharm Pract ; 26(8): 1921-1930, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32114883

ABSTRACT

INTRODUCTION: The primary objective was to describe environmental contamination with National Institute for Occupational Safety and Health Group 1 hazardous drugs in oncology pharmacies and outpatient clinics in Canada in 2019, as part of an annual surveillance project. METHODS: In each participating center, 12 standardized sites (6 in the oncology pharmacy and 6 in outpatient clinic) were sampled. Each sample was prepared to allow quantification of six antineoplastic drugs (cyclophosphamide, ifosfamide, methotrexate, gemcitabine, 5-fluorouracil, and irinotecan) by ultra-performance liquid chromatography-tandem mass spectrometry. Samples were also tested for three additional antineoplastic drugs (docetaxel, paclitaxel, and vinorelbine) without quantification. The impact of certain characteristics of the sampling sites was evaluated with a Kolmogorov-Smirnov test for independent samples. RESULTS: Ninety-three Canadian centers participated in 2019, with a total of 1045 surfaces sampled. Cyclophosphamide was the drug most often found in the surface samples (32.4% of samples with positive result), followed by gemcitabine (20.3%). The front grille inside the biological safety cabinet (81.5% of samples positive for at least one antineoplastic drug) and the armrest of a treatment chair (75.8%) were the most frequently contaminated surfaces. Centers with more oncology inpatient and outpatient beds, those that prepared more antineoplastic drugs each year, and those that used more cyclophosphamide each year had higher concentrations of cyclophosphamide contamination on the surfaces tested (p < 0.0001). CONCLUSION: Traces of dangerous drugs were found in oncology pharmacies and oncology outpatient clinics in 93 Canadian hospitals in 2019. However, the quantities measured were very small. Every healthcare worker should consider these work areas to be contaminated and should wear appropriate protective equipment.


Subject(s)
Antineoplastic Agents/analysis , Environmental Monitoring/methods , Equipment Contamination , Canada , Chromatography, Liquid , Cross-Sectional Studies , Drug Contamination , Hospitals , Humans , Occupational Exposure/analysis , Pharmacies
3.
J Oncol Pharm Pract ; 26(8): 1864-1870, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32138611

ABSTRACT

PURPOSE: The objective of this pilot study was to determine the frequency of urination and the concentration of four hazardous drugs (cyclophosphamide, ifosfamide, methotrexate, and fluorouracil) in workers' 24-h urine samples in relation to exposure to traces with hazardous drugs. METHODS: The study was conducted in three healthcare centers in the region of Montréal, Quebec, Canada. We recruited healthcare workers (nurses and pharmacy technicians) assigned to the hematology-oncology department. Each participant was asked to collect all urine voided during a 24-h period, to fill out an activity journal documenting tasks performed and to document the use of personal protective equipment. Samples were analyzed for cyclophosphamide, ifosfamide, methotrexate, and alpha-fluoro-beta-alanine (FBAL, the main urinary metabolite of 5-fluorouracil). Drugs were quantified by ultra-performance liquid chromatography-tandem mass spectrometry (positive electrospray MRM mode). RESULTS: Eighteen healthcare workers (10 nurses and 8 technicians) were recruited and provided consent to participate. Urine samples were obtained between 1 September and 30 September 2019. The number of urinations over the 24-h collection period ranged from 3 to 11 per participant. A total of 128 urine samples were analyzed for the 18 workers. All urine samples were negative for the four antineoplastics tested. CONCLUSION: No traces of cyclophosphamide, ifosfamide, methotrexate, or FBAL were found in the 24-h urine samples of 18 healthcare workers practicing in three healthcare facilities in Quebec. Although it was feasible to collect 24-h urine samples in this research project, it appears unrealistic to do so recurrently as part of a large-scale surveillance program.


Subject(s)
Antineoplastic Agents/analysis , Environmental Monitoring/methods , Occupational Exposure/analysis , Adult , Canada , Chromatography, Liquid , Cyclophosphamide/analysis , Fluorouracil/analysis , Health Personnel , Humans , Ifosfamide/analysis , Methotrexate/analysis , Middle Aged , Personal Protective Equipment , Pharmacy Technicians , Pilot Projects , Young Adult
4.
J Oncol Pharm Pract ; 26(2): 413-422, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31370747

ABSTRACT

PURPOSE: The main objective was to determine the efficacy of various types of cleaning equipment and products after deliberate contamination with cyclophosphamide. The secondary objective was to test various cleaning scenarios using these equipment and products. METHODS: The study had two phases: testing of cleaning equipment (wipe : woven microfibers - Hygen®, two layers of non-woven microfibres and an inner layer of highly absorbent viscose fibres - MicronSolo®, two layers of non-woven microfibres and an inner layer of highly absorbent viscose fibres - MicroMix®, simili-tissu (low filament production) - Tork® and, mop : woven microfibers - Hygen®, microfibre and viscose - MicroOne®) and products (disinfectant : quaternary ammonium - DR100®, chlorine 0.1% - Zochlor® - Brutab® - PCS® NPH, sodium hypochlorite 2%, cleaner : detergent - Nu- Action 3®, cleaner and disinfectant: sodium hypochlorite 0.6% + detergent - Aliflex® and water) in phase 1 and testing of various cleaning procedures in phase 2. Specific areas of a room with a laminar flow hood (class II/type B2) were contaminated with 10 mcg of cyclophosphamide. Different types of surfaces were cleaned with various scenarios and the remaining cyclophosphamide was measured by the Institut national de santé publique du Québec. All tests were performed in triplicate. RESULTS: A total of 189 samples were obtained: 42 negative controls and positive controls, 54 during phase 1 and 93 during phase 2. All products were more than 96.5% effective. The 0.1% chlorines were the most effective products. Cleaning procedures with two or three products had average cleaning efficacies of 99.94-99.99%. Efficacy increased with the number of successive cleanings. When two products were used, the average cleaning efficacy varied between 99.78% and 99.98%, depending on the surface. CONCLUSION: All cleaning products tested reduced cyclophosphamide contamination by more than 96.58%. Cleaning efficacy increased with successive cleaning. No scenario was effective in removing 100% of traces. Additional studies with larger samples should be conducted to confirm these results.


Subject(s)
Cyclophosphamide/analysis , Decontamination/methods , Disinfectants/administration & dosage , Equipment Contamination/prevention & control , Humans , Occupational Exposure/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...