Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
Microsyst Nanoeng ; 10: 41, 2024.
Article in English | MEDLINE | ID: mdl-38523657

ABSTRACT

The perception of fish locomotion is important for understanding their adaptive behaviors and ethological characteristics. However, the main strategy used for extracting fish attitudes involves the use of a vision-based monitoring system, which is limited in its range of observation and cannot perform tracking for long times. Here, we report the use of a wearable tagging electronic device, referred to as an underwater vest, to capture the surrounding flow field disturbances triggered by swimming or momentary postural changes. All of these goals were achieved by integrating a pair of pseudocapacitive pressure-sensing units and a flexible circuit board. Notably, additional conditions, such as variable hydraulic pressures and minimal changes in fish posture, require high stability and sensitivity of the sensing units. Thus, hybrid hydrogel electrodes were developed through cross-linking MXene with holey-reduced graphene oxide nanosheets and further modification with 1-ethyl-3-methylimidazolium dicyanamide ionic liquids, which increased the interfacial capacitance and long-term interfacial activity of the MXene. Consequently, the sensing unit exhibited ultrahigh sensitivity (Smax~136,207 kPa-1) in an aquatic environment for 60 days and superior high-pressure resolution (10 Pa) within a wide working range of 1 MPa. Ultimately, an underwater vest integrated with such sensing units clearly distinguished and recorded fish locomotion. We believe that the designed device may open avenues in flow field monitoring and ocean current detection and provide new insights into the development of sensitive underwater tagging.

2.
ACS Appl Mater Interfaces ; 15(40): 47733-47744, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37782111

ABSTRACT

Flexible pressure sensors developed rapidly with increased sensitivity, a fast response time, high stability, and excellent deformability. These progresses have expanded the application of wearable electronics under high-pressure backgrounds while also bringing new challenges. In particular, the nonlinearity and narrow working range lead to a gradually insensitive response, principally because the microstructure deforms inconsistently on the device interfaces in the whole working range. Herein, we report an ionic flexible sensor with a record-high linearity (R2 = 0.99994) in a wide working range (up to 600 kPa). The linearity response comes from the normal-direction graded hemisphere (GH) microstructure. It is prepared from poly(dimethylsiloxane) (PDMS)/carbon nanotubes (CNTs)/Au into flexible and deformable electrodes, and its geometry is precisely designed from the linear elastic theory and optimized through finite element simulation. The sensor can achieve a high sensitivity of S = 165.5 kPa-1, a response-relaxation time of <30 ms, and superb consistency, allowing the device to detect vibration signals. Our sensor has been assembled with circuits and capsulation in order to monitor the function state of players in underwater sports in the frequency domain. This work deepens the theory of linearized design of microstructures and provides a strategy to make flexible pressure sensors that have combined the performances of ultrahigh linearity, high sensitivity, and a wide working range.

3.
ACS Appl Mater Interfaces ; 15(16): 20421-20434, 2023 Apr 26.
Article in English | MEDLINE | ID: mdl-37039812

ABSTRACT

Underwater flexible sensors have a future for wide application, which is promising for attaching them to underwater creatures to monitor vital signals and biomechanical analysis of their motion and perceive tiny environmental disturbances. However, the pressure waves induced by biological swimming are extremely weak and susceptible to undercurrents, making them difficult to sense. Here, we report an ultrahighly sensitive biomimetic electronic fish skin designed by embedding an artificial pseudocapacitive-based hair cell into a simulated canal neuromast encapsulation structure, in which the artificial hair cell, as the key sensitive unit, is assembled from hybrid film electrodes and polyurethane-acidic electrolyte foam. Such a film is prepared by inter-cross-linking MXene and holey reduced graphene oxide with the assistance of l-cysteine, effectively increasing the interfacial capacitance and alleviating the oxidation issues of MXene. Meanwhile, the acidic foam with high porosity shows great compressibility to adapt to a high-pressure underwater environment. Consequently, the device exhibits ultrahighly sensitivity (maximum sensitivity ∼173688 kPa-1) over a wide range of depths (0-100 m) and remains stable after 10000 repeated tests. As an example case, the device is integrated as a motion monitoring system to identify the minor disturbances triggered by instantaneous postural changes of fish. The electronic fish skin is expected to demonstrate enormous potentials in flow field monitoring, ocean current detecting, and even seismic waves warning.


Subject(s)
Wearable Electronic Devices , Animals , Electronics , Polyurethanes
4.
Rev Sci Instrum ; 94(3): 035111, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-37012830

ABSTRACT

Magnetic interferential compensation plays a vital role in geomagnetic vector measurement applications. Traditional compensation accounts for only the permanent interferences, induced field interferences, and eddy-current interferences. However, nonlinear magnetic interferences are found, which also have a great impact on measurement, and it cannot be fully characterized by a linear compensation model. This paper proposes a new compensation method based on a back propagation neural network, which can reduce the influence of the linear model on compensation accuracy due to its good nonlinear mapping capabilities. The high-quality network training requires representative datasets, yet it is a common problem in the engineering field. To provide adequate data, this paper adopts a 3D Helmholtz coil to restore the magnetic signal of a geomagnetic vector measurement system. A 3D Helmholtz coil is more flexible and practical than the geomagnetic vector measurement system itself when generating abundant data under different postures and applications. Simulations and experiments are both conducted to prove the superiority of the proposed method. According to the experiment, the proposed method can reduce the root mean square errors of north, east, and vertical components and the total intensity from 73.25, 68.54, 70.45, and 101.77 nT to 23.35, 23.58, 27.42, and 29.72 nT, respectively, compared with the traditional method.

5.
ACS Omega ; 7(48): 43923-43933, 2022 Dec 06.
Article in English | MEDLINE | ID: mdl-36506201

ABSTRACT

A broad linear range of ionic flexible sensors (IFSs) with high sensitivity is vital to guarantee accurate pressure acquisition and simplify back-end circuits. However, the issue that sensitivity gradually decreases as the applied pressure increases hinders the linearity over the whole working range and limits its wide-ranging application. Herein, we design a two-scale random microstructure ionic gel film with rich porosity and a rough surface. It increases the buffer space during compression, enabling the stress deformation to be more uniform, which makes sure that the sensitivity maintains steady as the pressure loading. In addition, we develop electrodes with multilayer graphene produced by a roll-to-roll process, utilizing its large interlayer spacing and ion-accessible surface area. It benefits the migration and diffusion of ions inside the electrolyte, which increases the unit area capacitance and sensitivity, respectively. The IFS shows ultra-high linearity and a linear range (correlation coefficient ∼ 0.9931) over 0-1 MPa, an excellent sensitivity (∼12.8 kPa-1), a fast response and relaxation time (∼20 and ∼30 ms, respectively), a low detection limit (∼2.5 Pa), and outstanding mechanical stability. This work offers an available path to achieve wide-range linear response, which has potential applications for attaching to soft robots, followed with sensing slight disturbances induced by ships or submersibles.

6.
Nanomaterials (Basel) ; 11(11)2021 Nov 18.
Article in English | MEDLINE | ID: mdl-34835878

ABSTRACT

The strong spin filtering effect can be produced by C-Ni atomic orbital hybridization in lattice-matched graphene/Ni (111) heterostructures, which provides an ideal platform to improve the tunnel magnetoresistance (TMR) of magnetic tunnel junctions (MTJs). However, large-area, high-quality graphene/ferromagnetic epitaxial interfaces are mainly limited by the single-crystal size of the Ni (111) substrate and well-oriented graphene domains. In this work, based on the preparation of a 2-inch single-crystal Ni (111) film on an Al2O3 (0001) wafer, we successfully achieve the production of a full-coverage, high-quality graphene monolayer on a Ni (111) substrate with an atomically sharp interface via ambient pressure chemical vapor deposition (APCVD). The high crystallinity and strong coupling of the well-oriented epitaxial graphene/Ni (111) interface are systematically investigated and carefully demonstrated. Through the analysis of the growth model, it is shown that the oriented growth induced by the Ni (111) crystal, the optimized graphene nucleation and the subsurface carbon density jointly contribute to the resulting high-quality graphene/Ni (111) heterostructure. Our work provides a convenient approach for the controllable fabrication of a large-area homogeneous graphene/ferromagnetic interface, which would benefit interface engineering of graphene-based MTJs and future chip-level 2D spintronic applications.

7.
Nanoscale ; 13(38): 16113-16121, 2021 Oct 08.
Article in English | MEDLINE | ID: mdl-34633011

ABSTRACT

The magnetic tunneling junction (MTJ) controlled by electric field as an alternate approach for energy efficiency is the highlight for nonvolatile RAM, while there is still a lack of research on resistance manipulation with the electric field in nanoscale MTJs. In this study, we integrated nanoscale MTJs on the (011) orientated Pb(Mg1/3Nb2/3)0.7Ti0.3O3 (PMN-PT) ferroelectric substrates and systematically investigated the magnetoresistance as a function of the magnetic field and electric field. A single domain state of the nanoscale MTJ was demonstrated by the experimental result and theoretical simulation. Afterward, the obvious electric field control of R-H curves was obtained and explained by the competition between magnetoelastic energy and shape anisotropy. More importantly, simulation results also predicted that the switching pathway of magnetic moments under the magnetic field is strongly dependent on the applied electric field, displaying the electric field control of chiral switching in the nano-MTJ. Our work is a milestone in the realization of the emerging dubbed straintronics field.

8.
Micromachines (Basel) ; 12(6)2021 Jun 19.
Article in English | MEDLINE | ID: mdl-34205388

ABSTRACT

Magnetic flux vertical modulation method based on piezoelectric resonance can reduce the 1/f noise of tunnel magnetoresistance (TMR) magnetic sensor and significantly improves the low-frequency magnetic field detectivity. However, the amplitude variation of the modulation structure will lead to the instability of the sensor output. In order to improve the amplitude stability of the modulation structure, an amplitude control method based on the amplitude ratio of the first and second harmonic components of the modulated signal was proposed. Compared with the piezoelectric or capacitive feedback method, this method does not require an independent amplitude conversion circuit, and has the advantages of simple structure, high control efficiency and strong anti-interference ability. The experimental results showed that the amplitude and temperature drift of the modulated structure was significantly suppressed, which is of great significance for enhancing the adaptability of the TMR magnetic sensor to the application environments.

9.
Rev Sci Instrum ; 91(9): 095001, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-33003805

ABSTRACT

A thermal barrier coating (TBC), which is composed of a top coating (TC) and bond coating (BC), can keep a turbine engine working in high temperature. The TC is an insulated ceramic layer, and the BC is a conductive layer between the TC and engine blade. Owing to poor working conditions, some failures such as sintering, thinning of coating thickness, and oxide layer initiation will occur in the TBC. Once any part of the TBC fails, it will seriously threaten the safety of the aircraft. The quantitative detection of TBC parameters is realized with the electromagnetic/capacitive dual modality sensor in this paper. The measurement grid algorithm is used to inverse the thickness of the TC layer and the conductivity of the BC layer, and an analytical method is proposed to inverse the relative permittivity of the TC layer. According to the experiment, the inversion errors of these parameters are all less than 4%, which can meet the industry needs well.

10.
Sensors (Basel) ; 20(5)2020 Mar 06.
Article in English | MEDLINE | ID: mdl-32155770

ABSTRACT

The low frequency magnetic field detection ability of magnetoresistive (MR)sensor is seriously affected by 1/f noise. At present, the method to suppress the influence of low frequency noise is mainly to modulate the measured magnetic field by mechanical resonance. In this paper, a novel modulation concept employing a magnetoelectric coupling effect is proposed. A design method of modulation structure based on an equivalent magnetic circuit model (EMCM) and a single domain model of in-plane moment was established. An EMCM was established to examine the relationship between the permeability of flux modulation film (FMF) and modulation efficiency, which was further verified through a finite element simulation model (FESM). Then, the permeability modulated by the voltage of a ferroelectric/ferromagnetic (FE/FM) multiferroic heterostructure was theoretically studied. Combining these studies, the modulation structure and the material were further optimized, and a FeSiBPC/PMN-PT sample was prepared. Experimental results show that the actual magnetic susceptibility modulation ability of FeSiBPC/PMN-PT reached 150 times, and is in good agreement with the theoretical prediction. A theoretical modulation efficiency higher than 73% driven by a voltage of 10 V in FeSiBPC/PMN-PT can be obtained. These studies show a new concept for magnetoelectric coupling application, and establish a new method for magnetic field modulation with a multiferroic heterostructure.

11.
Sensors (Basel) ; 19(20)2019 Oct 15.
Article in English | MEDLINE | ID: mdl-31619009

ABSTRACT

To improve the sensitivity of the magnetic tunnel junction(MTJ)sensor, a novel architecture for a double-gap magnetic flux concentrator (MFC) was studied theoretically and experimentally in this paper. The three-dimensional finite element model of magnetic flux was established to optimize the magnetic field amplification factor, with different gaps. The simulation results indicate that the sensitivity of an MTJ sensor with a double-gap MFC can be significantly better than that of a sensor with a traditional single-gap MFC, due to the fact that the magnetic magnification sharply increases with the decrease in effective gap width. Besides this, the half-bridge MTJ sensors with the double-gap MFC were fabricated using photolithography, ion milling, evaporation, and electroplating processes. Experimental results show that the sensitivity of the MTJ sensor increased by ten times compared to the sensor without the double-gap MFC, which underlines the theoretical predictions. Furthermore, there is no significant increase in the sensor noise. The work in this paper contributes to the development of high-performance MTJ sensors.

12.
Rev Sci Instrum ; 89(6): 064703, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29960525

ABSTRACT

In order to comprehensively evaluate the thermal barrier coating system of an engine blade, an integrated planar sensor combining electromagnetic coils with planar capacitors is designed, in which the capacitance measurement accuracy of the planar capacitor is a key factor. The micro-capacitance measurement system is built based on an impedance analyzer. Because of the influence of non-ideal factors on the measuring system, there is an obvious difference between the measured value and the actual value. It is necessary to calibrate the measured results and eliminate the difference. In this paper, the measurement model of a planar capacitive sensor is established, and the relationship between the measured value and the actual value of capacitance is deduced. The model parameters are estimated with the least square method, and the calibration accuracy is evaluated with experiments under different dielectric conditions. The capacitance measurement error is reduced from 29% ∼ 46.5% to around 1% after calibration, which verifies the feasibility of the calibration method.

13.
Sensors (Basel) ; 18(5)2018 May 19.
Article in English | MEDLINE | ID: mdl-29783746

ABSTRACT

Thermal barrier coatings (TBCs) can significantly reduce the operating temperature of the aeroengine turbine blade substrate, and their testing technology is very urgently demanded. Due to their complex multi-layer structure, it is hard to evaluate TBCs with a single function sensor. In this paper, an electromagnetic/capacitive composite sensor is proposed for the testing of thermal barrier coatings. The dielectric material is tested with planar capacitor, and the metallic material is tested with electromagnetic coils. Then, the comprehensive test and evaluation of thermal barrier coating system can be realized. The sensor is optimized by means of theoretical and simulation analysis, and the interaction between the planar capacitor and the electromagnetic coil is studied. The experimental system is built based on an impedance analyser and multiplex unit to evaluate the performance of the composite sensor. The transimpedances and capacitances are measured under different coating parameters, such as thickness and permittivity of top coating as well as bond layer conductivity. The experimental results agree with the simulation analysis, and the feasibility of the sensor is proved.

14.
Rev Sci Instrum ; 88(9): 095006, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28964192

ABSTRACT

Magnetic modulation methods especially Micro-Electro-Mechanical System (MEMS) modulation can improve the sensitivity of magnetoresistive (MR) sensors dramatically, and pT level detection of Direct Current (DC) magnetic field can be realized. While in a Low Frequency Alternate Current (LFAC) magnetic field measurement situation, frequency measurement is limited by a serious spectrum aliasing problem caused by the remanence in sensors and geomagnetic field, leading to target information loss because frequency indicates the magnetic target characteristics. In this paper, a compensation field produced with integrated coils is applied to the MR sensor to remove DC magnetic field distortion, and a LFAC magnetic field frequency estimation algorithm is proposed based on a search of the database, which is derived from the numerical model revealing the relationship of the LFAC frequency and determination factor [defined by the ratio of Discrete Fourier Transform (DFT) coefficients]. In this algorithm, an inverse modulation of sensor signals is performed to detect jumping-off point of LFAC in the time domain; this step is exploited to determine sampling points to be processed. A determination factor is calculated and taken into database to figure out frequency with a binary search algorithm. Experimental results demonstrate that the frequency measurement resolution of the LFAC magnetic field is improved from 12.2 Hz to 0.8 Hz by the presented method, which, within the signal band of a magnetic anomaly (0.04-2 Hz), indicates that the proposed method may expand the applications of magnetoresistive (MR) sensors to human healthcare and magnetic anomaly detection (MAD).

15.
ACS Appl Mater Interfaces ; 9(3): 2642-2649, 2017 Jan 25.
Article in English | MEDLINE | ID: mdl-28025891

ABSTRACT

Intrinsic spatial inhomogeneity or phase separation in cuprates, manganites, etc., related to electronic and/or magnetic properties, has attracted much attention due to its significance in fundamental physics and applications. Here we use scanning Kerr microscopy and scanning electron microscopy with polarization analysis with in situ electric fields to reveal the existence of intrinsic spatial inhomogeneity of the magnetic response to an electric field on a mesoscale with the coexistence of looplike (nonvolatile) and butterfly-like (volatile) behaviors in Co40Fe40B20/Pb(Mg1/3Nb2/3)0.7Ti0.3O3 ferromagnetic/ferroelectric (FM/FE) multiferroic heterostructures. Both the experimental results and micromagnetic simulations suggest that these two behaviors come from the 109° and the 71°/180° FE domain switching, respectively, which have a spatial distribution. This FE domain-switching-controlled magnetism is significant for understanding the nature of FM/FE coupling on the mesoscale and provides a path for designing magnetoelectric devices through domain engineering.

16.
Rev Sci Instrum ; 87(10): 105002, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27802727

ABSTRACT

Frequency estimation is a fundamental problem in many applications, such as traditional vibration measurement, power system supervision, and microelectromechanical system sensors control. In this paper, a fast and accurate frequency estimation algorithm is proposed to deal with low efficiency problem in traditional methods. The proposed algorithm consists of coarse and fine frequency estimation steps, and we demonstrate that it is more efficient than conventional searching methods to achieve coarse frequency estimation (location peak of FFT amplitude) by applying modified zero-crossing technique. Thus, the proposed estimation algorithm requires less hardware and software sources and can achieve even higher efficiency when the experimental data increase. Experimental results with modulated magnetic signal show that the root mean square error of frequency estimation is below 0.032 Hz with the proposed algorithm, which has lower computational complexity and better global performance than conventional frequency estimation methods.

17.
Sensors (Basel) ; 15(12): 32138-51, 2015 Dec 21.
Article in English | MEDLINE | ID: mdl-26703608

ABSTRACT

The eddy current probe, which is flexible, array typed, highly sensitive and capable of quantitative inspection is one practical requirement in nondestructive testing and also a research hotspot. A novel flexible planar eddy current sensor array for the inspection of microcrack presentation in critical parts of airplanes is developed in this paper. Both exciting and sensing coils are etched on polyimide films using a flexible printed circuit board technique, thus conforming the sensor to complex geometric structures. In order to serve the needs of condition-based maintenance (CBM), the proposed sensor array is comprised of 64 elements. Its spatial resolution is only 0.8 mm, and it is not only sensitive to shallow microcracks, but also capable of sizing the length of fatigue cracks. The details and advantages of our sensor design are introduced. The working principal and the crack responses are analyzed by finite element simulation, with which a crack length sizing algorithm is proposed. Experiments based on standard specimens are implemented to verify the validity of our simulation and the efficiency of the crack length sizing algorithm. Experimental results show that the sensor array is sensitive to microcracks, and is capable of crack length sizing with an accuracy within ±0.2 mm.

18.
Molecules ; 19(12): 20808-20, 2014 Dec 12.
Article in English | MEDLINE | ID: mdl-25514223

ABSTRACT

This study reports on the optimization of the extraction conditions of cordycepin from Cordyceps militaris by using ultrasonication. For this purpose, the orthogonal experimental design was used to investigate the effects of factors on the ultrasonic-assisted extraction (UAE). Four factors: extraction time (min), ethanol concentration (%), extraction temperature (°C) and extraction frequency (kHz), were studied. The results showed that the highest cordycepin yield of 7.04 mg/g (86.98% ± 0.23%) was obtained with an extraction time of 60 min, ethanol concentration of 50%, extraction temperature of 65 °C and extraction frequency of 56 kHz. It was found that the cordycepin extraction yield increased with the effect of ultrasonication during the extraction process. Therefore, UAE can be used as an alternative to conventional immersion extraction with respect to the recovery of cordycepin from C. militaris, with the advantages of shorter extraction time and reduced solvent consumption.


Subject(s)
Antineoplastic Agents/isolation & purification , Cordyceps/chemistry , Deoxyadenosines/isolation & purification , Ethanol/chemistry , Research Design , Solid Phase Extraction , Solvents/chemistry , Sonication , Sound
19.
Article in English | MEDLINE | ID: mdl-25474781

ABSTRACT

In this paper, two multi-frequency time-reversal (TR)-based imaging algorithms are explored for application to the nondestructive evaluation (NDE) imaging of defects in solids: time reversal with multiple signal classification (TRMUSIC) and a related phase-coherent form (PC-MUSIC). These algorithms are tested with simulated and experimental ultrasonic array data acquired using the full matrix capture (FMC) process. The performance of these algorithms is quantified in terms of their spatial resolution and robustness to noise. The effect of frequency bandwidth is investigated and the results are compared with the single-frequency versions of these algorithms. It is shown that both TR-MUSIC and PCMUSIC are capable of resolving lateral targets spaced closer than the Rayleigh limit, achieving super-resolution imaging. TR-MUSIC can locate the positions of scatterers correctly, whereas the results from PC-MUSIC are less clear because of the presence of multiple peaks in the vicinity of target. However, an advantage of PC-MUSIC is that it can overcome the elongated point spread function that appears in TR-MUSIC images, and hence provide enhanced axial resolution. For high noise levels, TR-MUSIC and PC-MUSIC are shown to provide stable images and suppress the presence of artifacts seen in their single-frequency equivalents.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Ultrasonography/methods , Artifacts , Signal-To-Noise Ratio
20.
Ultrasonics ; 54(7): 1842-50, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24457032

ABSTRACT

In this paper the total focusing method, the so called gold standard in classical beamforming, is compared with the widely used time-reversal MUSIC super resolution technique in terms of its ability to resolve closely spaced scatterers in a solid. The algorithms are tested with simulated and experimental array data, each containing different noise levels. The performance of the algorithms is evaluated in terms of lateral resolution and sensitivity to noise. It is shown that for the weak noise situation (SNR>20 dB), time-reversal MUSIC provides significantly enhanced lateral resolution when compared to the total focusing method, breaking the diffraction limit. However, for higher noise levels, the total focusing method is shown to be robust, whilst the performance of time-reversal MUSIC is degraded. The influence of multiple scattering on the imaging algorithms is also investigated and shown to be small.

SELECTION OF CITATIONS
SEARCH DETAIL
...