1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(8): 2289-92, 2014 Aug.
Article in Chinese | MEDLINE | ID: mdl-25474979

ABSTRACT

In order to analyze spectral data quantitatively which is obtained by prism-grating-prism imaging spectrometer, spectral calibration is required in order to determine spectral characteristics of PGP imaging spectrometer, such as the center wavelength of every spectral channel, spectral resolution and spectral bending. A spectral calibration system of full field based on collimated monochromatic light method is designed. Spherical mirror is used to provide collimated light, and a freely sliding and rotating folding mirror is adopted to change the angle of incident light in order to realize full field and automatic calibration of imaging spectrometer. Experiments of spectral calibration have been done for PGP imaging spectrometer to obtain parameters of spectral performance, and accuracy analysis combined with the structural features of the entire spectral calibration system have been done. Analysis results indicate that spectral calibration accuracy of the calibration system reaches 0.1 nm, and the bandwidth accuracy reaches 1.3%. The calibration system has merits of small size, better commonality, high precision and so on, and because of adopting the control of automation, the additional errors which are caused by human are avoided. The calibration system can be used for spectral calibration of other imaging spectrometers whose structures are similar to PGP.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(11): 3162-6, 2013 Nov.
Article in Chinese | MEDLINE | ID: mdl-24555403

ABSTRACT

The present paper aimed at the question that the beam cross-section changes according to the rotation of concave grating during the measuring process, and the appropriate supplement to the principle of the program was done. The appropriate supplement to the principle lay the foundation for the derivation of the beam cross-section k(theta), and the whole analytical expression of changes factor of the beam cross-section k (theta) for concave grating was derived. Because of the relationship between the theoretical values and the factors which affect the diffraction efficiency measuring accuracy was nonlinear, the quadratic nonlinear regression analysis was introduced and the compensating formula was established. The results show further correction to diffraction efficiency measurements for concave grating, the range of differences between the compensated values and the theoretical values was reduced from +/- 2.5% to less than +/- 0.3%, compared with the linear regression analysis, and the quadratic nonlinear regression analysis significantly reduces the variation between the compensated values and the theoretical values, which further ensures the accurate measurement of the diffraction efficiency for concave gratings. The compensating process is embedded in the measurement program; this method is strongly real-time, which can satisfy the requirements of simple operation, testing speediness and preciseness.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(3): 839-43, 2012 Mar.
Article in Chinese | MEDLINE | ID: mdl-22582665

ABSTRACT

The hyperspectrum imaging spectrometer will achieve miniaturization and high spectrum resolution and high space resolution along with development of the hyperspectrum imaging technology that is becoming a trend. This trend requires the designers to improve and optimize their designing constantly in designing the instruments. The present paper carried out a method of integrative design for imaging spectrometer. This method suggested that the design and optimization work of the disperse systems of imaging spectrometers would take into account the whole systems, but not consider themselves only. It would get a perfect result by using this method. This paper also explained in details how the method can be used in the design course of imaging spectrometer with convex grating which has been used widely recently. Finally, this paper validated the method by testing the imaging spectrometer with convex grating, which was developed using this method.