Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
2.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37738643

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Time Factors , Pulmonary Veins/surgery , Catheter Ablation/methods , United Kingdom , Recurrence
3.
J Interv Card Electrophysiol ; 66(3): 551-559, 2023 Apr.
Article in English | MEDLINE | ID: mdl-35192098

ABSTRACT

BACKGROUND: The DiamondTemp ablation (DTA) catheter system delivers high power, open-irrigated, temperature-controlled radiofrequency (RF) ablation. This novel ablation system has not been previously used for ventricular tachycardia (VT) ablation. OBJECTIVE: Feasibility of using the DTA catheter system for VT ablation in ischaemic cardiomyopathy (ICM) patients. METHOD: Ten ICM patients with optimal anti-arrhythmic drug therapy and implantable cardiac defibrillators (ICD) were recruited. VT inducibility testing was performed at the end of the procedure. ICD data for device detected VT episodes and device treated VT episodes were collected for 6-months pre- and post-ablation. RESULTS: Substrate analysis demonstrated reductions in the borderzone area of 4.4 cm2 (p = 0.026) and late potential area of 3.5 cm2 (p = 0.0449) post-ablation, with reductions in the mean bipolar and unipolar voltages of the ablation target areas (0.14 mV (p = 0.0007); 0.59 mV (p = 0.0072) respectively). Complete procedural success was achieved in 9 procedures. Post-ablation VT inducibility testing was not performed in 1 procedure due to a steam pop complication resulting in pericardial tamponade requiring drainage. Mean follow-up of 214 ± 33 days revealed an 88% reduction in total VT episodes (n = 266 median 16 [IQR 3-57] to n = 33 median 0; p = 0.0164) and 77% reduction in ICD therapies (n = 128 median 5 [IQR 2-15] to n = 30 median 0; p = 0.0181). CONCLUSION: The DTA system resulted in adequate lesion characteristics with effective substrate modification, acute procedural success and improved outcomes at intermediate-term follow-up. Randomised controlled trials are required to compare the performance of the DTA system against conventional ablation catheters.


Subject(s)
Cardiomyopathies , Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Treatment Outcome , Temperature , Myocardial Ischemia/complications , Myocardial Ischemia/surgery , Catheter Ablation/methods
4.
Pilot Feasibility Stud ; 8(1): 101, 2022 May 07.
Article in English | MEDLINE | ID: mdl-35525992

ABSTRACT

BACKGROUND: The PULSE (PostUraL tachycardia Syndrome Exercise) study is a randomised controlled trial assessing the feasibility of conducting a multicentre RCT testing supervised exercise rehabilitation with behavioural and motivational support, compared to best-practice usual care, for people with Postural Tachycardia Syndrome (PoTS). The original trial protocol was published in BMC Pilot & Feasibility Studies (accessible at https://doi.org/10.1186/s40814-020-00702-1 ). The PULSE intervention consists of (1) individual assessment; (2) 12-week, twice-weekly, supervised exercise training; (3) behavioural and motivational support; and (4) guided lifestyle physical activity. The control intervention is best-practice usual care with a single 30-min, one-to-one practitioner appointment, and general advice on safe and effective physical activity. Sixty-two people (aged 18-60 years) with a confirmed diagnosis of PoTS will be invited to enrol on a feasibility RCT with an embedded qualitative study. The primary outcome will be feasibility; process-related measures will include eligibility, recruitment, randomisation and withdrawal rates, along with indicators of exercise programme adherence and acceptability. Secondary physiological, clinical and health-related outcomes will be assessed. In response to the COVID-19 pandemic, here we describe amendments to the trial protocol. METHODS: Restrictions imposed by the COVID-19 pandemic meant it was necessary to change the delivery of the PULSE and control interventions. These changes reflected the need to limit the risk of COVID-19 transmission in a clinical population, some of whom were at increased risk of contracting the virus and suffering serious illness. The major change was that the originally intended centre-based PULSE and control interventions would now be delivered remotely on-line. Subsequently, there were minor changes to the participant eligibility criteria. These decisions followed an on-line co-creation session with people affected by PoTS, and relevant public and professional stakeholders. CONCLUSIONS: We present an update of the original trial protocol in response to the COVID-19 pandemic. No participants were recruited to the original protocol; thus, results will reflect the on-line delivery of the intervention. PULSE will be the first randomised trial to assess the feasibility of conducting a definitive multi-centre RCT testing supervised on-line exercise rehabilitation with behavioural and motivational support, compared to best-practice usual care, for people with PoTS. TRIAL REGISTRATION: ISRCTN45323485 registered on 7 April 2020.

5.
Heart Rhythm ; 19(3): 443-447, 2022 03.
Article in English | MEDLINE | ID: mdl-34767989

ABSTRACT

BACKGROUND: Implantable loop recorders (ILRs) are effective in achieving symptom-rhythm correlation. Data on the diagnostic yield of ILRs, on nurse-led syncope clinics, and on nurse-led ILR implants are limited. OBJECTIVE: We evaluated the safety and efficacy of our nurse-led syncope clinic and nurse-led ILR implants. METHODS: A retrospective study of all consecutive patients undergoing nurse-led ILR implantations was performed between April 2016 and April 2018. Patients were referred from both nurse-led and physician-led clinics. Data were collected on baseline demographic characteristics, referral source, symptom-rhythm correlation, ILR findings, and subsequent changes to management. All ILRs were enrolled into remote monitoring with automatic arrhythmia detection, and all immediate (≤24 hours) ILR implant complications were recorded. Comparisons were made between nurse-led and physician-led clinics and subsequent outcomes. RESULTS: A total of 432 patients with an ILR were identified: 164 (38%) from nurse-led and 268 (62%) from physician-led clinics; 200 (46%) were women (mean age 66.5 ± 18.2 years; mean follow-up duration 28.9 ± 9.5 months). Primary ILR indications were syncope (n = 251 [58%]), presyncope (n = 33 [7%]), palpitation (n = 39 [9%]), cryptogenic stroke (n = 78 [18%]), and other reasons (n = 31 [7%]). No immediate ILR implant complications occurred. Overall, 156 patients (36%) had a change in management as a direct result of ILR findings, with no overall differences between nurse-led and physician-led clinics (35% vs 36%; P = .7). More patients had newly diagnosed atrial fibrillation in physician-led clinics (15% vs 7%; P = .01), and more patients had pacemaker implants for bradycardia in nurse-led clinics (23% vs 13%; P < .01). CONCLUSION: Nurse-led ILR implantation was safe and effective. Nurse-led syncope clinics achieved good symptom-rhythm correlation with resultant significant changes to management in comparison to physician-led clinics. Larger prospective studies are needed to evaluate their longer-term impact.


Subject(s)
Atrial Fibrillation , Pacemaker, Artificial , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Electrocardiography, Ambulatory/adverse effects , Female , Humans , Male , Middle Aged , Nurse's Role , Pacemaker, Artificial/adverse effects , Retrospective Studies , Syncope/diagnosis , Syncope/etiology , Syncope/therapy
6.
J Arrhythm ; 37(6): 1522-1531, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34887957

ABSTRACT

BACKGROUND: Transvenous lead extraction (TLE) for implantable cardiac-devices is traditionally performed under general anesthesia (GA). This can lead to greater risk of exposure to COVID-19, longer recovery-times and increased procedural-costs. We report the feasibility/safety of TLE using conscious-sedation alone with immediate GA/cardiac-surgery back-up if needed. METHODS: Retrospective case-series of consecutive TLEs performed using conscious-sedation alone between March 2016 and December 2019. All were performed in the electrophysiology-laboratory using intravenous Fentanyl, Midazolam/Diazepam with a stepwise approach using locking-stylets/cutting-sheaths, including mechanical-sheaths. Baseline patient-characteristics, procedural-details and TLE outcomes (including procedure-related complications/death) were recorded. RESULTS: A total of 130 leads were targeted in 54 patients, mean age ± SD 74.6 ± 11.8years, 47(87%) males; dual-chamber pacemakers (n = 26; 48%), cardiac resynchronization therapy-defibrillators (n = 17; 31%) and defibrillators (n = 8; 15%) were commonest extracted devices. Mean ± SD/median (range) lead-dwell times were 11.0 ± 8.8/8.3 (0.3-37) years, respectively. Extraction indications included systemic infection (n = 23; 43%) and lead/pulse-generator erosion (n = 27; 50%); mean 2.1 ± 2.0 leads were removed per procedure/mean procedure-time was 100 ± 54 min. Local anesthetic (LA) was used for all (mean-dose: 33 ± 8 ml 1% lidocaine), IV drug-doses used (mean ± SD) were: midazolam: 3.95 ± 2.44 mg, diazepam: 4.69 ± 0.89 mg and fentanyl: 57 ± 40 µg. Complete lead-extraction was achieved in 110 (85%) leads, partial lead-extraction (<4 cm-fragment remaining) in 5 (4%) leads. Sedation-related hypotension requiring IV fluids occurred in 2 (managed without adverse-consequences) and hypoxia requiring additional airway-management in none. No procedural deaths occurred, one patient required emergency cardiac surgery for localized ventricular perforation, nine had minor complications (transient hypotension/bradycardia/pericardial effusion not requiring intervention). CONCLUSION: TLE undertaken using LA/conscious-sedation was safe/feasible in our series and associated with good clinical outcome/low procedural complications. Reduced risk of aerosolization of COVID-19 and quicker patient recovery/reduced anesthetic risk are potential benefits that warrant further study.

8.
J Interv Card Electrophysiol ; 62(3): 519-529, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33392856

ABSTRACT

BACKGROUND: Substrate mapping has highlighted the importance of targeting diastolic conduction channels and late potentials during ventricular tachycardia (VT) ablation. State-of-the-art multipolar mapping catheters have enhanced mapping capabilities. The purpose of this study was to investigate whether long-term outcomes were improved with the use of a HD Grid mapping catheter combining complementary mapping strategies in patients with structural heart disease VT. METHODS: Consecutive patients underwent VT ablation assigned to either HD Grid, Pentaray, Duodeca, or point-by-point (PbyP) RF mapping catheters. Clinical endpoints included recurrent anti-tachycardia pacing (ATP), appropriate shock, asymptomatic non-sustained VT, or all-cause death. RESULTS: Seventy-three procedures were performed (33 HD Grid, 22 Pentaray, 12 Duodeca, and 6 PbyP) with no significant difference in baseline characteristics. Substrate mapping was performed in 97% of cases. Activation maps were generated in 82% of HD Grid cases (Pentaray 64%; Duodeca 92%; PbyP 33% (p = 0.025)) with similar trends in entrainment and pace mapping. Elimination of all VTs occurred in 79% of HD Grid cases (Pentaray 55%; Duodeca 83%; PbyP 33% (p = 0.04)). With a mean follow-up of 372 ± 234 days, freedom from recurrent ATP and shock was 97% and 100% respectively in the HD Grid group (Pentaray 64%, 82%; Duodeca 58%, 83%; PbyP 33%, 33% (log rank p = 0.0042, p = 0.0002)). CONCLUSIONS: This study highlights a step-wise improvement in survival free from ICD therapies as the density of mapping capability increases. By using a high-density mapping catheter and combining complementary mapping strategies in a strict procedural workflow, long-term clinical outcomes are improved.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Catheters , Electrodes , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Treatment Outcome
9.
Br J Cardiol ; 28(4): 48, 2021.
Article in English | MEDLINE | ID: mdl-35747065

ABSTRACT

Implantable cardiac defibrillators (ICDs) can prevent sudden cardiac death, but the risk of recurrent ventricular arrhythmia (VA) and ICD shocks persist. Strategies to minimise such risks include medication optimisation, device programming and ventricular tachycardia (VT) ablation. Whether the choice of these interventions at follow-up are influenced by factors such as the type of arrhythmia or ICD therapy remains unclear. To investigate this, we evaluated ICD follow-up strategies in a real-world population with primary and secondary prevention ICDs. REFINE-VT (Real-world Evaluation of Follow-up strategies after Implantable cardiac-defibrillator therapies in patients with Ventricular Tachycardia) is an observational study of 514 ICD recipients recruited between 2018 and 2019. We found that 77 patients (15%) suffered significant VA and/or ICD therapies, of whom 26% experienced a second event; 31% received no intervention. We observed an inconsistent approach to the choice of strategies across different types of arrhythmias and ICD therapies. Odds of intervening were significantly higher if ICD shock was detected compared with anti-tachycardia pacing (odds ratio [OR] 8.4, 95% confidence interval [CI] 1.7 to 39.6, p=0.007). Even in patients with two events, the rate of escalation of antiarrhythmics or referral for VT ablation were as low as patients with single events. This is the first contemporary study evaluating how strategies that reduce the risk of recurrent ICD events are executed in a real-world population. Significant inconsistencies in the choice of interventions exist, supporting the need for a multi-disciplinary approach to provide evidence-based care to this population.

10.
Int J Cardiol ; 322: 170-174, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33002522

ABSTRACT

BACKGROUND: Catheter ablation for complex left-atrial arrhythmia is increasing worldwide with many centres admitting patients overnight. Same-day procedures using conscious sedation carry significant benefits to patients/healthcare providers but data are limited. We evaluated the safety and cost-effectiveness of same-day complex left-atrial arrhythmia ablation. METHOD: Multi-centre retrospective cohort study of all consecutive complex elective left-atrial ablation procedures performed between January 2011 and December 2019. Data were collected on planned same-day discharge versus overnight stay, baseline parameters, procedure details/success, ablation technology, post-operative complications, unplanned overnight admissions/outcomes at 4-months and mortality up to April 2020. A cost analysis of potential savings was also performed. RESULTS: A total of 967 consecutive patients underwent complex left-ablation using radiofrequency (point-by-point ablation aided by 3D-mapping or PVAC catheter ablation with fluoroscopic screening) or cryoballoon-ablation (mean age: 60.9 ± 11.6 years, range 23-83 yrs., 572 [59%] females). The majority of patients had isolation of pulmonary veins alone (n = 846, 87%) and most using conscious-sedation alone (n = 921, 95%). Of the total cohort, 414 (43%) had planned same-day procedure with 35 (8%) admitted overnight due to major (n = 5) or minor (n = 30) complications. Overall acute procedural success-rate was 96% (n = 932). Complications in planned overnight-stay/same-day cohorts were low. At 4-month follow-up there were 62 (6.4%) readmissions (femoral haematomas, palpitation, other reasons); there were 3 deaths at mean follow-up of 42.0 ± 27.6 months, none related to the procedure. Overnight stay costs £350; the same-day ablation policy over this period would have saved £310,450. CONCLUSIONS: Same-day complex left-atrial catheter ablation using conscious sedation is safe and cost-effective with significant benefits for patients and healthcare providers. This is especially important in the current financial climate and Covid-19 pandemic.


Subject(s)
Ambulatory Surgical Procedures/economics , Arrhythmias, Cardiac/surgery , Catheter Ablation/economics , Cost-Benefit Analysis , Adult , Aged , Aged, 80 and over , Ambulatory Surgical Procedures/adverse effects , Catheter Ablation/adverse effects , Cohort Studies , Female , Heart Atria/surgery , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
11.
Pacing Clin Electrophysiol ; 44(2): 318-326, 2021 02.
Article in English | MEDLINE | ID: mdl-33377500

ABSTRACT

OBJECTIVES: To study how left atrial appendage electrical isolation (LAAEI) impacts atrial dominant frequency (DF) in patients with long-standing persistent atrial fibrillation (LSPAF). BACKGROUND: LAAEI is associated with a high probability of freedom from atrial fibrillation (AF) and spectral analysis may identify high-frequency sources. How LAAEI impacts the AF dynamics and the subgroup of LSPAF patients in whom LAAEI would be most beneficial, is unclear. METHODS: Twenty patients with LSPAF were included in the study. Fast Fourier transforms (FFT) were performed on atrial electrograms recorded from 13 sites in the LA and RA. The highest peak frequency was defined as DF. RESULTS: There was no significant difference in DF between atrial sites except for at the superior vena cava which had the lowest DF at baseline. Stepwise ablation consisting of circumferential pulmonary vein isolation and a linear ablation set of mitral isthmus and roof significantly reduced the DF within the coronary sinus (CS) (5.93 ± 0.98 Hz vs. 5.09 ± 0.72 Hz, p < .05) and the LA posterior wall (LApos) (6.26 ± 0.92 Hz vs. 5.43 ± 0.98 Hz, p < .01). LAAEI preferentially further decreased the DF at the LApos (p < .01), but not at the CS. In cases where there was < 13.6% reduction in the DF of the LApos following the stepwise ablation, the addition of LAAEI was associated with an increased restoration of sinus rhythm (55%, p < .05). CONCLUSION: LAAEI in addition to stepwise ablation results in further reduction of the DF in the LApos, which is associated with acute termination of AF and favorable ablation outcome.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation/methods , Aged , Atrial Fibrillation/physiopathology , Cardiac Surgical Procedures/methods , Clinical Protocols , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged
12.
Pilot Feasibility Stud ; 6: 157, 2020.
Article in English | MEDLINE | ID: mdl-33083000

ABSTRACT

BACKGROUND: Postural orthostatic tachycardia syndrome (POTS) is an autonomic nervous system disorder causing an abnormal cardiovascular response to upright posture. It affects around 0.2% of the population, most commonly women aged 13 to 50 years. POTS can be debilitating; prolonged episodes of pre-syncope and fatigue can severely affect activities of daily living and health-related quality of life (HRQoL). Medical treatment is limited and not supported by randomised controlled trial (RCT) evidence. Lifestyle interventions are first-line treatment, including increased fluid and salt intake, compression tights and isometric counter-pressure manoeuvres to prevent fainting. Observational studies and small RCTs suggest exercise training may improve symptoms and HRQoL in POTS, but evidence quality is low. METHODS: Sixty-two people (aged 18-40 years) with a confirmed diagnosis of POTS will be invited to enrol on a feasibility RCT with embedded qualitative study. The primary outcome will be feasibility; process-related measures will include the number of people eligible, recruited, randomised and withdrawn, along with indicators of exercise programme adherence and acceptability. Secondary physiological, clinical and health-related outcomes including sub-maximal recumbent bike exercise test, active stand test and HRQoL will be measured at 4 and 7 months post-randomisation by researchers blinded to treatment allocation. The PostUraL tachycardia Syndrome Exercise (PULSE) intervention consists of (1) individual assessment; (2) 12-week, once to twice-weekly, supervised out-patient exercise training; (3) behavioural and motivational support; and (4) guided lifestyle physical activity. The control intervention will be best-practice usual care with a single 30-min, one-to-one practitioner appointment, and general advice on safe and effective physical activity. For the embedded qualitative study, participants (n = 10 intervention, n = 10 control) will be interviewed at baseline and 4 months post-randomisation to assess acceptability and the feasibility of progressing to a definitive trial. DISCUSSION: There is very little high-quality research investigating exercise rehabilitation for people with POTS. The PULSE study will be the first randomised trial to assess the feasibility of conducting a definitive multicentre RCT testing supervised exercise rehabilitation with behavioural and motivational support, compared to best-practice usual care, for people with POTS. TRIAL REGISTRATION: ISRCTN45323485 registered on 7 April 2020.

13.
Eur Heart J Case Rep ; 4(6): 1-5, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33442609

ABSTRACT

BACKGROUND: Circulatory collapse during/post-pulmonary vein (PV) isolation by cryo-balloon ablation is a Cardiology emergency that has multiple potential causes and requires a methodical investigative approach. Some of the complications that can arise include cardiac tamponade, bleeding/vascular injury, anaphylaxis, Addisonian crisis, acute pulmonary embolism, acute PV stenosis, oesophageal injury, and vagal reaction. CASE SUMMARY: Here, we present a case of a 76-year-old lady who developed profound circulatory collapse during an elective pulmonary vein isolation by cryo-balloon ablation for symptomatic paroxysmal atrial fibrillation (AF). Cardiac tamponade, bleeding/vascular injury, and other less common causes were excluded. She only responded transiently to fluid resuscitation and developed intermittent bradyarrhythmias and hypotension which responded to isoprenaline. She was discharged home at Day 3 post-AF ablation after remaining well and continued to do so at follow-up. DISCUSSION: Circulatory collapse during/post-PV cryo-balloon ablation is a Cardiology emergency that has multiple potential causes. The ganglionate plexi form part of the cardiac intrinsic autonomic nervous system (ANS) and are located close to the left atrial-PV junctions. The presence of vagal response has been observed to be a marker of ANS modulation although its significance on the long-term outcome post-ablation has yet to be elucidated. The true cause of our patient's profound circulatory collapse is uncertain but a vital learning point in this case is the systematic exclusion of common and potentially life-threatening complications following AF ablation. A persistent vagal reaction secondary to PV cryo-balloon ablation can usually be managed with supportive medical therapy as demonstrated in our case.

14.
J Interv Card Electrophysiol ; 58(3): 355-362, 2020 Sep.
Article in English | MEDLINE | ID: mdl-31598876

ABSTRACT

BACKGROUND: Defining diastolic slow-conduction channels within the borderzone (BZ) of scar-dependent re-entrant ventricular tachycardia (VT) is key for effective mapping and ablation strategies. Understanding wavefront propagation is driving advances in high-density (HD) mapping. The newly developed Advisor™ HD Grid Mapping Catheter (HD GRID) has equidistant spacing of 16, 1 mm electrodes in a 4 × 4 3 mm interspaced arrangement allowing bipolar recordings along and uniquely across the splines (orthogonal vector) to facilitate substrate mapping in a WAVE configuration (WAVE). The purpose of this study was to determine the relative importance of the WAVE configuration compared to the STANDARD linear-only bipolar configuration (STANDARD) in defining VT substrate. METHODS: Thirteen patients underwent VT ablation at our institution. In all cases, a substrate map was constructed with the HD GRID in the WAVE configuration (conWAVE) to guide ablation strategy. At the end of the procedure, the voltage map was remapped in the STANDARD configuration (conSTANDARD) using the turbo-map function. Detailed post-hoc analysis of the WAVE and STANDARD maps was performed blinded to the configuration. Quantification of total scar area, BZ and dense scar area with assessment of conduction channels (CC) was performed. RESULTS: The substrate maps conSTANDARD vs conWAVE showed statistically significant differences in the total scar area (56 ± 32 cm2 vs 51 ± 30 cm2; p = 0.035), dense scar area (36 ± 25 cm2 vs 29 ± 22 cm2; p = 0.002) and number of CC (3.3 ± 1.6 vs 4.8 ± 2.5; p = 0.026). conWAVE collected more points than the conSTANDARD settings (p = 0.001); however, it used fewer points in map construction (p = 0.023). CONCLUSIONS: The multipolar Advisor™ HD Grid Mapping Catheter in conWAVE provides more efficient point acquisition and greater VT substrate definition of the borderzone particularly at the low-voltage range compared to conSTANDARD. This greater resolution within the low-voltage range facilitated CC definition and quantification within the scar, which is essential in guiding the ablation strategy.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Catheters , Cicatrix , Heart Rate , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery
15.
Open Heart ; 6(2): e000996, 2019.
Article in English | MEDLINE | ID: mdl-31673380

ABSTRACT

Background: Ventricular tachycardia (VT) is associated with increased morbidity and mortality. There is growing evidence for the effectiveness of catheter ablation in improving outcomes in patients with recurrent VT. Consequently the threshold for referral for VT ablation has fallen over recent years, resulting in increased number of procedures. Objective: To evaluate the effectiveness and safety of VT ablation in a real-world tertiary centre setting. Methods: This is a prospective analysis of all VT ablation cases performed at University Hospital Coventry. Follow-up data were obtained from review of electronic medical records and patient interview. The primary endpoint for normal heart VT was death, cardiovascular hospitalisation and VT recurrence, and for structural heart VT was arrhythmic death, VT storm (>3 episodes within 24 hours) or appropriate shock. Results: Forty-seven patients underwent 53 procedures from January 2012 to January 2018. The mean age ±SD was 57±15 years, 68% were male, 81% were Caucasian and 66% were elective cases. The aetiology of VT included normal heart (49%), ischaemic cardiomyopathy (ICM, 36%), dilated cardiomyopathy (9%), hypertrophic cardiomyopathy (4%) and valvular heart disease (2%). Procedural success occurred in 83%, with six major complications. After a median follow-up of 231 days (lower quartile 133, upper quartile 631), the primary outcome occurred in 28% of patients. There were two non-arrhythmic deaths (4%). At a median follow-up of 193 days (129-468), the primary outcome occurred in 19% of patients with ICM, while VT storm/appropriate shocks occurred in three patients (17%). Conclusions: Our real-world registry confirms that VT ablation is safe, and is associated with high acute procedural success and long-term outcomes comparable with randomised controlled studies.

16.
J Am Heart Assoc ; 8(4): e010535, 2019 02 19.
Article in English | MEDLINE | ID: mdl-30773973

ABSTRACT

Background Atrial tachycardia ( AT ) is common in patients with adult congenital heart disease and is challenging to map and ablate. We used ultra-high-density mapping to characterize the AT mechanism and investigate whether substrate characteristics are related to ablation outcomes. Methods and Results A total of 50 AT s were mapped with ultra-high-density mapping in 23 procedures. Patients were followed up for up to 12 months. Procedures were classified to group A if there was 1 single AT induced (n=12) and group B if there were ≥2 AT s induced (n=11 procedures). AT mechanism per procedure was macro re-entry (n=10) and localized re-entry (n=2) in group A and multiple focal (n=6) or multiple macro re-entry (n=5) in group B. Procedure duration, low voltage area (0.05-0.5 mV), and low voltage area indexed for volume were higher in group B (159 [147-180] versus 412 [352-420] minutes, P<0.001, 22.6 [12.2-29.8] versus 54.2 [51.1-61.6] cm2, P=0.014 and 0.17 [0.12-0.21] versus 0.26 [0.23-0.27] cm2/mL, P=0.024 accordingly). Dense scar (<0.05 mV) and atrial volume were similar between groups. Acute success and freedom from arrhythmia recurrence were worse in group B (100% versus 77% P=0.009 and 11.3, CI 9.8-12.7 versus 4.9, CI 2.2-7.6 months, log rank P=0.004). Indexed low voltage area ≥0.24 cm2/mL could predict recurrence with 100% sensitivity and 77% specificity (area under the curve 0.923, P=0.007). Conclusions Larger low voltage area but not dense scar is associated with the induction of multiple focal or re-entry AT s, which are subsequently associated with longer procedure duration and worse acute and midterm clinical outcomes.


Subject(s)
Body Surface Potential Mapping/methods , Catheter Ablation/methods , Heart Atria/physiopathology , Heart Defects, Congenital/complications , Tachycardia, Supraventricular/physiopathology , Adult , Female , Follow-Up Studies , Heart Atria/diagnostic imaging , Heart Defects, Congenital/diagnosis , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/surgery , Time Factors , Treatment Outcome
17.
Int J Cardiol ; 277: 110-117, 2019 Feb 15.
Article in English | MEDLINE | ID: mdl-30196998

ABSTRACT

BACKGROUND: To investigate the long term outcomes after catheter ablation (CA) of ventricular tachycardia (VT) in the context of structural heart disease in a multicenter cohort. The impact of different ablation strategies (substrate ablation versus activation guided versus combined) and non-inducibility as an end-point was evaluated. METHODS: Data was pooled from prospective registries at 5 centres over a 5 year period. Success was defined as survival free from recurrent ventricular arrhythmias (VA). Multivariate analysis of factors predicting survival free from VA was analysed by Cox regression. RESULTS: Five hundred sixty-six patients underwent CA for VT. Patients were 64 ±â€¯15 years. Left ventricular ejection fraction was 35 ±â€¯15% and 66% had ischaemic heart disease. At 2.3 (IQR 1.0-4.2) years, success was achieved in 44% after a single procedure, rising to 60% after repeat procedures. Mortality at final follow up was 22%. Multivariate analysis showed that higher left ventricular ejection fraction, younger age, ischaemic heart disease, and non-inducibility of VA predicted long term survival free from VA (all p < 0.05). There was no impact of the approach to ablation. CONCLUSION: CA eliminates VT in a large proportion of patients long term. Ablation strategy did not impact outcome and hence substrate ablation is a reasonable initial strategy. Non-inducibility of VA predicted survival free from VA and may be worth pursuing as a procedural end-point.


Subject(s)
Catheter Ablation/trends , Endpoint Determination/trends , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Aged , Catheter Ablation/mortality , Cohort Studies , Endpoint Determination/mortality , Female , Follow-Up Studies , Humans , Male , Middle Aged , Mortality/trends , Prospective Studies , Registries , Tachycardia, Ventricular/mortality , Treatment Outcome
19.
Europace ; 20(3): 451-458, 2018 03 01.
Article in English | MEDLINE | ID: mdl-28108547

ABSTRACT

Aims: Characterizing the differences in substrate and clinical outcome between heart failure (HF) and non-heart failure (non-HF) patients undergoing persistent atrial fibrillation (AF) ablation. Methods and results: Using complex fractionated electrograms (CFE) as a surrogate marker of substrate complexity, we compared the bi-atrial substrate in patients with persistent AF with and without HF, at baseline and after ablation, to determine its impact on clinical outcome. In this retrospective analysis of two prospective studies, 60 patients underwent de-novo step-wise left atrial (LA) ablation, 30 with normal left ventricular ejection fraction (LVEF) ≥ 50% (non-HF group) and 30 with LVEF ≤ 35% (HF group). Multiple high-density bi-atrial CFE maps were acquired along with AF cycle length (AFCL) at each procedural stage. Change in bi-atrial CFE areas, AFCL and outcome data were then compared. In the non-HF group, higher CFE-areas were found at baseline and at each step of the procedure in the LA. In both LA and the right atrium (RA), baseline and final CFE area were also higher in the non-HF group. Single procedure, arrhythmia-free survival at 1 year was higher in the HF group compared with the non-HF group (72% vs. 43%, log rank P = 0.04). Final total bi-atrial CFE area was an independent predictor of arrhythmia recurrence. Conclusions: CFE represents an important surrogate marker of atrial substrate complexity. The atrial substrate in persistent AF differs between HF and non-HF with the latter representing a more complex 'primary' bi-atrial myopathy. LA focussed ablation results in more extensive substrate modification in HF and better clinical outcomes as compared with non-HF.


Subject(s)
Atrial Fibrillation/complications , Electrophysiologic Techniques, Cardiac , Heart Conduction System/physiopathology , Heart Failure/complications , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation , Female , Heart Conduction System/surgery , Heart Failure/diagnosis , Heart Failure/physiopathology , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Progression-Free Survival , Recurrence , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
20.
Heart Rhythm ; 14(11): 1596-1603, 2017 11.
Article in English | MEDLINE | ID: mdl-29101964

ABSTRACT

BACKGROUND: Catheter ablation (CA) outcomes for long-standing persistent atrial fibrillation (LSPAF) remain suboptimal. Thoracoscopic surgical ablation (SA) provides an alternative approach in this difficult to treat cohort. OBJECTIVE: To compare electrophysiological (EP) guided thoracoscopic SA with percutaneous CA as the first-line strategy in the treatment of LSPAF. METHODS: Fifty-one patients with de novo symptomatic LSPAF were recruited. Twenty-six patients underwent electrophysiologically guided thoracoscopic SA. Conduction block was tested for all lesions intraoperatively by an independent electrophysiologist. In the CA group, 25 consecutive patients underwent stepwise left atrial (LA) ablation. The primary end point was single-procedure freedom from atrial fibrillation (AF) and atrial tachycardia (AT) lasting >30 seconds without antiarrhythmic drugs at 12 months. RESULTS: Single- and multiprocedure freedom from AF/AT was higher in the SA group than in the CA group: 19 of 26 patients (73%) vs 8 of 25 patients (32%) (P = .003) and 20 of 26 patients (77%) vs 15 of 25 patients (60%) (P = .19), respectively. Testing of the SA lesion set by an electrophysiologist increased the success rate in achieving acute conduction block by 19%. In the SA group, complications were experienced by 7 of 26 patients (27%) vs 2 of 25 patients (8%) in the CA group (P = .07). CONCLUSION: In LSPAF, meticulous electrophysiologically guided thoracoscopic SA as a first-line strategy may provide excellent single-procedure success rates as compared with those of CA, but there is an increased up-front risk of nonfatal complications.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Electrocardiography, Ambulatory/methods , Electrophysiologic Techniques, Cardiac/methods , Heart Rate/physiology , Surgery, Computer-Assisted/methods , Thoracoscopy/methods , Aged , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...