1.
Phys Med ; 115: 103159, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37852021

ABSTRACT

It is well known that foetuses are highly sensitive to ionising radiation and special attention to justification and optimisation of radiological procedures involving a pregnant patient is required. A task to review, validate and compare different approaches to managing the pregnant patient and to estimating the associated foetal doses arising from a diagnostic or interventional radiology (DIR) procedure was designed in the framework of EURADOS working group 12. As a first step, a survey of radiation protection practice including dosimetry considerations among EURADOS members was performed using online questionnaire. Then, to evaluate the possible differences in the estimated foetal doses, a comparison of assessed dose values was made for three cases of pregnant patients that underwent different CT procedures. More than 120 professionals from 108 institutions and 17 countries that are involved in managing pregnant patients undergoing DIR procedures answered the questionnaire. Most of the respondents use national or hospital guidelines on the management of pregnant patients undergoing DIR procedures. However, the guidelines differ considerably among respondents. Comparison of foetal dose assessments performed by dosimetry experts showed the variety of methods used as well as large variability of estimated foetal doses in all three cases. Although European and International commission on radiation protection guidelines already exist, they are more than 20 years old and, in some aspects, they are obsolete. This paper shows that there is a need to revise and update these guidelines.


Subject(s)
Radiation Protection , Radiology, Interventional , Pregnancy , Female , Humans , Young Adult , Adult , Radiation Dosage , Radiation Protection/methods , Radiography , Radiometry
2.
Phys Med ; 46: 67-74, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29519411

ABSTRACT

PURPOSE: The feasibility of setting-up generic, hospital-independent dose alert levels to initiate vigilance on possible skin injuries in interventional procedures was studied for three high-dose procedures (chemoembolization (TACE) of the liver, neuro-embolization (NE) and percutaneous coronary intervention (PCI)) in 9 European countries. METHODS: Gafchromic® films and thermoluminescent dosimeters (TLD) were used to determine the Maximum Skin Dose (MSD). Correlation of the online dose indicators (fluoroscopy time, kerma- or dose-area product (KAP or DAP) and cumulative air kerma at interventional reference point (Ka,r)) with MSD was evaluated and used to establish the alert levels corresponding to a MSD of 2 Gy and 5 Gy. The uncertainties of alert levels in terms of DAP and Ka,r, and uncertainty of MSD were calculated. RESULTS: About 20-30% of all MSD values exceeded 2 Gy while only 2-6% exceeded 5 Gy. The correlations suggest that both DAP and Ka,r can be used as a dose indicator for alert levels (Pearson correlation coefficient p mostly >0.8), while fluoroscopy time is not suitable (p mostly <0.6). Generic alert levels based on DAP (Gy cm2) were suggested for MSD of both 2 Gy and 5 Gy (for 5 Gy: TACE 750, PCI 250 and NE 400). The suggested levels are close to the lowest values published in several other studies. The uncertainty of the MSD was estimated to be around 10-15% and of hospital-specific skin dose alert levels about 20-30% (with coverage factor k = 1). CONCLUSIONS: The generic alert levels are feasible for some cases but should be used with caution, only as the first approximation, while hospital-specific alert levels are preferred as the final approach.


Subject(s)
Fluoroscopy/adverse effects , Skin/radiation effects , Surgery, Computer-Assisted , Feasibility Studies , Humans , Thermoluminescent Dosimetry