1.
Stem Cell Rev Rep ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38914791

ABSTRACT

The stem cell niche in the bone marrow is a hypoxic environment, where the low oxygen tension preserves the pluripotency of stem cells. We have identified mesangiogenic progenitor cells (MPC) exhibiting angiogenic and mesenchymal differentiation capabilities in vitro. The effect of hypoxia on MPC has not been previously explored. In this study, MPCs were isolated from volunteers' bone marrow and cultured under both normoxic and hypoxic conditions (3% O2). MPCs maintained their characteristic morphology and surface marker expression (CD18 + CD31 + CD90-CD73-) under hypoxia. However, hypoxic conditions led to reduced MPC proliferation in primary cultures and hindered their differentiation into mesenchymal stem cells (MSCs) upon exposure to differentiative medium. First passage MSCs derived from MPC appeared unaffected by hypoxia, exhibiting no discernible differences in proliferative potential or cell cycle. However, hypoxia impeded the subsequent osteogenic differentiation of MSCs, as evidenced by decreased hydroxyapatite deposition. Conversely, hypoxia did not impact the angiogenic differentiation potential of MPCs, as demonstrated by spheroid-based assays revealing comparable angiogenic sprouting and tube-like formation capabilities under both hypoxic and normoxic conditions. These findings indicate that hypoxia preserves the stemness phenotype of MPCs, inhibits their differentiation into MSCs, and hampers their osteogenic maturation while leaving their angiogenic potential unaffected. Our study sheds light on the intricate effects of hypoxia on bone marrow-derived MPCs and their differentiation pathways.

2.
Cureus ; 16(3): e56413, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38638784

ABSTRACT

INTRODUCTION: Meniscal injuries are a common challenge in orthopedic surgery. For decades, partial or total meniscectomy has been the primary surgical treatment for meniscal tears. In recent years, the increased recognition of menisci's biomechanical importance has progressively shifted the paradigm towards meniscus repair. However, meniscus-sparing surgery remains the treatment of choice for selected lesions in young and active patients, especially for young and active patients. In this study, we evaluated the effectiveness of all-inside sutures in treating meniscus tears in patients over 40. METHODS: In our retrospective evaluation, we evaluated the clinical and functional outcomes of cases over 40 years of age with post-traumatic acute meniscus tears that received meniscus repairs using the all-inside technique. The pre-operative and post-operative functionality of treated patients were assessed using the knee injury and osteoarthritis outcome score (KOOS) score. Major complications were recorded. RESULTS: Twenty-three cases met our inclusion criteria. Eight females and fifteen males with a mean age of 44.9 were included in our study. Their mean follow-up was 35.1 months. Before surgery, our patients' mean KOOS score was 55.4 (18-80). At the patients' latest follow-up, the value had risen to 87.4 (63-100). There was no statistical correlation between patients' age and their functional recovery. No surgical failure was recorded at the latest follow-up. CONCLUSION: The all-inside suture technique can represent a suitable and reliable solution for suturable meniscal tears, even for patients over 40. Preserving the meniscus and restoring patients' functionality allows patients to return to their daily activities and promote their quality of life.

3.
Bioengineering (Basel) ; 10(12)2023 Nov 23.
Article in English | MEDLINE | ID: mdl-38135936

ABSTRACT

Pedicle screw fixation (PSF) demands rigorous training to mitigate the risk of severe neurovascular complications arising from screw misplacement. This paper introduces a patient-specific phantom designed for PSF training, extending a portion of the learning process beyond the confines of the surgical room. Six phantoms of the thoracolumbar region were fabricated from radiological datasets, combining 3D printing and casting techniques. The phantoms were employed in three training sessions by a fifth-year resident who performed full training on all six phantoms; he/she placed a total of 57 pedicle screws. Analysis of the learning curve, focusing on time per screw and positioning accuracy, revealed attainment of an asymptotic performance level (around 3 min per screw) after 40 screws. The phantom's efficacy was evaluated by three experts and six residents, each inserting a minimum of four screws. Initial assessments confirmed face, content, and construct validity, affirming the patient-specific phantoms as a valuable training resource. These proposed phantoms exhibit great promise as an essential tool in surgical training as they exhibited a demonstrable learning effect on the PSF technique. This study lays the foundation for further exploration and underscores the potential impact of these patient-specific phantoms on the future of spinal surgical education.

4.
Healthcare (Basel) ; 11(22)2023 Nov 19.
Article in English | MEDLINE | ID: mdl-37998476

ABSTRACT

BACKGROUND AND OBJECTIVES: Megaprostheses are the most used reconstructive approach for patients who have undergone massive resection of their distal femurs due to bone tumors. Although the literature about their outcomes has flourished in recent decades, to date, a consensus on rehabilitative treatment is yet to be established. In this study, we report on our experience with our latest standardized rehabilitation program, evaluating our results in a mid-to-long-term scenario. MATERIALS AND METHODS: We evaluated the functional results of all our oncologic patients treated between 2016 and 2022 who could follow our standardized post-operative rehabilitative approach, consisting of progressive knee mobilization and early weight-bearing. RESULTS: Sixteen cases were included in our study. The average duration of the patients' hospitalization was 12.2 days. A standing position was reached on average 4.1 days after surgery, while assisted walking was started 4.5 days after surgery. After a mean post-operative follow-up of 46.7 months, our patients' mean MSTS score was 23.2 (10-30). Our data suggest that the sooner patients could achieve a standing position (R = -0.609; p = 0.012) and start walking (R = -0.623; p = 0.010), the better their final functional outcomes regarding their MSTS scores. CONCLUSIONS: Rehabilitation should be considered a pivotal factor in decreeing the success of distal femur megaprosthetic implants in long-surviving oncologic patients. Correct rehabilitation, focused on early mobilization and progressive weight-bearing, is crucial to maximizing the post-operative functional outcomes of these patients.

5.
Healthcare (Basel) ; 11(19)2023 Sep 27.
Article in English | MEDLINE | ID: mdl-37830669

ABSTRACT

Giant Cell Tumor of Bone is a benign tumor with high local aggressive expansion, which, in rare cases, spreads metastasis. Surgical treatment, which often consists of wide curettage to reduce recurrence risk, can lower the quality of life for those affected. Along with aggressive surgery, adjuvant intraoperative techniques have been implemented such as PMMA and cryotherapy. One of the most widely used cryotherapy techniques involves the use of probes to generate ice balls, which have been scientifically shown to have various impacts on the tumor. Although this has been acknowledged, no one has yet tested a way to accurately plan the positioning of cryotherapy probes before surgery, according to the research conducted by the authors. CRIO2AR is a randomized clinical prospective ongoing study by which it will be experimented via preoperative planning of ice probes placement using AR and 3D printing technologies. By studying a single clinical case with these technologies, the surgeon gains better awareness of patient's anatomy and tumor localization. Preliminary results are shown in the article. The first results are confirming that these technologies are applicable in clinical practice. Secondly, preoperative planning is proving to be reliable, easily replicable, and useful for the surgeon.

6.
Healthcare (Basel) ; 11(19)2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37830695

ABSTRACT

BACKGROUND: Aneurysmal bone cysts (ABCs) are benign but locally aggressive cystic lesions of the bone. Pelvic ABCs are extremely rare and hard to treat due to their high risk of local recurrence and the tough access to pelvic bones. METHODS: In this retrospective study, we evaluated pediatric cases with pelvic ABC treated with curettage, cryotherapy and bone grafting treated in our institution between 2016 and 2022. Complications were recorded, as well as local recurrences. Patients' post-operative functionality was assessed with the MSTS score. RESULTS: Fourteen consecutive cases were included in our study. Their mean age at surgery was 13.5 years. The mean lesion size was 55 mm. The mean follow-up was 38 months. Two cases (11.8%) had local recurrences, which were successfully treated with further curettage. At their latest FU, 13 cases were continuously disease free (CDF), and one had no evidence of disease (NED). Only one case had a post-operative compilation (wound dehiscence). Patients' mean post-operative MSTS score was 29.6. CONCLUSIONS: Pelvic ABCs are a challenge, even for the most experienced orthopedic surgeon. Our study suggests that the association of an accurate curettage, intraoperative cryotherapy and bone grafting can be a reliable and effective therapeutic option for large-sized ABCs of the pelvis.

7.
Adv Orthop ; 2023: 1868943, 2023.
Article in English | MEDLINE | ID: mdl-36938102

ABSTRACT

Background: Knee osteoarthritis is a common disease with increasing incidence and prevalence in western countries. It can cause severe pain and functional limitations, thereby representing a threat for patients' quality of life and a burden for national health systems. Intra-articular injections with hyaluronic acid (HA) and platelet-rich plasma (PRP) have been used for decades in order to reduce the symptoms caused by osteoarthritis. In recent years, a combination of HA and PRP has been introduced in clinical practice with the aim to minimize the clinical presentation of osteoarthritis and potentially delay articular degeneration. Materials and Methods: Sixty cases with grade II-III knee osteoarthritis according to the Kellgren-Lawrence classification were included in a prospective study, focused on the evaluation of clinical and functional outcomes after intra-articular knee injections. Cases were randomly divided into three groups. Twenty cases (Group A) were injected with HA, 20 (Group B) had PRP, and the remaining 20 (Group C) received a combination of HA and PRP. Basal WOMAC score and VAS score were recorded before the treatment and repeated within 3 and 6 months after the treatment. Results: At 6-month follow-up, Group C (PRP + HA) was the one with the lowest WOMAC and VAS mean values. It was also the only group that reported a reduction in the two values both in the first three months and in the following three months. No major complication was recorded. Conclusion: The combination of platelet-rich plasma and hyaluronic acid can be effective in the treatment of grade II-III knee osteoarthritis in a short-to-mid-term scenario. It represents an innovative and valuable alternative to the administration of its two components alone.

8.
Acta Biomed ; 94(1): e2023013, 2023 02 13.
Article in English | MEDLINE | ID: mdl-36786271

ABSTRACT

BACKGROUND AND AIM: Femoral neck fractures are among the most frequent in mankind. Screw fixation is considered a suitable approach specially for undisplaced or slightly displaced fractures that occur to young patients. We conducted our study in order to evaluate both functional outcomes and complication rates of patients who received this treatment in our institution. A particular focus was given to the aseptic necrosis of the head, trying to identify if anamnestic, clinical or radiological data could play a significant role as prognostic factors. METHODS: For each case who was treated with screw fixation due to a femoral neck fracture, we recorded data regarding, among the others, BMI and whether they used tobacco products or corticosteroids on a regular basis. Necrosis of the femoral head and mechanical complications were recorded. Functional outcome was evaluated using the Harris Hip Score.      Results: 74 cases were included in our study. The mean Harris Hip score was 89.5. Aseptic necrosis of the femoral head occurred in 9 cases (12.2%). Regular use of tobacco was associated with a higher risk to develop necrosis (p=0.007). The Body Mass Index was significantly higher in cases who had necrosis compared to the rest of our population (p=0.043) and was inversely proportional to the post-operative Harris hip score (p=0.001). CONCLUSIONS: While considering screw fixation to treat cases with femoral neck fractures, patient's weight and use of tobacco should be considered as prognostic factors.  (www.actabiomedica.it).


Subject(s)
Femoral Neck Fractures , Femur Head Necrosis , Surgeons , Humans , Femur Head Necrosis/etiology , Femur Head Necrosis/surgery , Fracture Fixation, Internal/adverse effects , Femoral Neck Fractures/surgery , Bone Screws/adverse effects , Treatment Outcome , Retrospective Studies
9.
J Clin Med ; 10(20)2021 Oct 15.
Article in English | MEDLINE | ID: mdl-34682858

ABSTRACT

BACKGROUND: Although cementless implants are increasing in popularity, the use of cementless femoral stems for total hip arthroplasty (THA) and hip hemiarthroplasty (HH) in elderly patients remains controversial. The aim of this study was to report the outcomes of a cementless stem used in a large multicentric cohort of elderly patients receiving elective THA and HH for displaced femoral neck fracture. METHODS: A total of 293 patients (301 hips) aged 70 years or older (mean age, 78 years; range, 70-93) who received the same cementless plasma-sprayed porous titanium-hydroxyapatite stem were retrospectively evaluated after primary THA and HH to investigate stem survival, complications, and clinical and radiographic results. RESULTS: Cumulative stem survival was 98.5% (95% CI, 96.4-99.4%; 91 hips at risks) with revision due to any reason as the end-point at 10-year follow-up (mean 8.6 years, range 4-12). No stem was revised due to aseptic loosening. The mean Forgotten Joint Score was 98.7. Radiographically, the implants showed complete osseointegration, with slight stress-shieling signs in less than 10% of the hips. CONCLUSION: The use of cementless stems was proven to be a reliable and versatile option even in elderly patients for elective THA and HH for femoral neck fracture.

10.
J Imaging ; 7(8)2021 Aug 05.
Article in English | MEDLINE | ID: mdl-34460773

ABSTRACT

Wearable Video See-Through (VST) devices for Augmented Reality (AR) and for obtaining a Magnified View are taking hold in the medical and surgical fields. However, these devices are not yet usable in daily clinical practice, due to focusing problems and a limited depth of field. This study investigates the use of liquid-lens optics to create an autofocus system for wearable VST visors. The autofocus system is based on a Time of Flight (TOF) distance sensor and an active autofocus control system. The integrated autofocus system in the wearable VST viewers showed good potential in terms of providing rapid focus at various distances and a magnified view.

11.
Sensors (Basel) ; 21(13)2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34209748

ABSTRACT

Cryosurgery is a technique of growing popularity involving tissue ablation under controlled freezing. Technological advancement of devices along with surgical technique improvements have turned cryosurgery from an experimental to an established option for treating several diseases. However, cryosurgery is still limited by inaccurate planning based primarily on 2D visualization of the patient's preoperative images. Several works have been aimed at modelling cryoablation through heat transfer simulations; however, most software applications do not meet some key requirements for clinical routine use, such as high computational speed and user-friendliness. This work aims to develop an intuitive platform for anatomical understanding and pre-operative planning by integrating the information content of radiological images and cryoprobe specifications either in a 3D virtual environment (desktop application) or in a hybrid simulator, which exploits the potential of the 3D printing and augmented reality functionalities of Microsoft HoloLens. The proposed platform was preliminarily validated for the retrospective planning/simulation of two surgical cases. Results suggest that the platform is easy and quick to learn and could be used in clinical practice to improve anatomical understanding, to make surgical planning easier than the traditional method, and to strengthen the memorization of surgical planning.


Subject(s)
Augmented Reality , Cryosurgery , Computer Simulation , Humans , Retrospective Studies , Software
12.
Acta Biomed ; 92(3): e2021280, 2021 07 01.
Article in English | MEDLINE | ID: mdl-34212934

ABSTRACT

Purpose The purpose of this bibliometric study was to summarize European orthopedic literature produced by EFORT memberships between 2009 and 2019 and to identify the 100 most cited articles, analyzing the characteristics that made them so interesting for the orthopedic scientific world. Method A search of the literature was conducted using Clarivate Analytics Web of Science in the subject category "orthopaedics"; then the results were summarized using Web of Science tools. Results A total of 160.375 articles were found: most of these were produced by England. In particular the most prolific institution was the University of London. Analyzing in detail the 100 most cited publications emerged that most of them were review published in journal with high impact factor (Q1). The University of Oxford was the institution with the greatest number of contributions (13%). The most cited topics were osteoarthritis (24%), followed by orthopedic basic science (22%). Biomaterials was the most common topic by ordering the 100 analyzed articles according to "usage count", a recent indicator of the level of interest in a specific item. Conclusion This bibliometric study can be useful to identify topics of interest for future scientific research and to outline the features that make some publications more interesting than others.


Subject(s)
Orthopedic Procedures , Orthopedics , Bibliometrics , England , Humans , Publications
13.
Article in English | MEDLINE | ID: mdl-32759871

ABSTRACT

Restoring bone loss is one of the major challenges when facing hip revision surgery. To eliminate the risk of disease transmission and antigenicity of allografts and donor-morbidity of autografts, the use of synthetic bioceramics has become popular in the last decade. Our study investigated the effectiveness of impaction bone grafting (IBG) of contained acetabular defects (Paprosky 2 and 3a) using a porous ceramic-based hydroxyapatite bone substitute (Engipore, provided by Finceramica Faenza S.p.A., Faenza, Italy) mixed with a low percentage of autologous bone (obtained from reaming when available). We retrospectively assessed 36 patients who underwent acetabular revision using IBG using a porous ceramic-based hydroxyapatite bone substitute with cementless implants with a mean follow-up of 4.4 years. We evaluated, at regular intervals, patients clinically (using the Hip Harris Score and Oxford Score) and radiologically to evaluate the rate of incorporation of the graft, the presence of radiolucent lines or migrations of the cup. Clinical scores significantly improved (WOMAC improved from 49.7-67.30, and the HSS from 56-89). The rate of implants' survival was 100% at our medium follow-up (4.4 years). We reported five cases of minor migration of the cup, and radiolucent lines were visible in seven patients at the last-follow up. The graft was well-incorporated in all patients. The results presented in this study suggest the HA bone substitute is an effective and safe bone graft when facing hip revision surgery; thus, longer follow-up studies are required.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Transplantation , Hip Prosthesis , Follow-Up Studies , Humans , Italy , Prosthesis Failure , Reoperation , Retrospective Studies , Treatment Outcome
14.
Surg Technol Int ; 36: 341-346, 2020 May 28.
Article in English | MEDLINE | ID: mdl-32190898

ABSTRACT

En bloc scapulectomy with covering muscles was historically considered the only procedure available for surgical treatment of bone and soft tissue tumors of the scapula. When possible, reconstruction with scapular allograft is the gold standard, and gives satisfactory functional, cosmetic, and oncological outcomes. While good results have recently been reported with 3D-printed prostheses for reconstruction of bone loss, there is little information available in the medical literature regarding scapula reconstruction with a 3D-printed prosthesis. Between 2016 and 2018, we performed four scapular resections (two total and two involving the superior 1/3) followed by reconstruction with a 3D-printed prosthesis made of a porous titanium alloy (Ti-6Al-4V, diameter between 100 and 400 mm), using computer-aided design (CAD) and patient-specific implants (PSI) with previously acquired CT-MR fusion images. At 2 years follow-up, the patients with partial scapulectomy had an MSTS score of 76%, no local or systemic recurrence, good clinical results and no pain. At 1 year 6 months follow-up, the patients with total scapulectomy had an MSTS score of 46%, no local or systemic recurrence, fair clinical results and no pain. Thus, custom-made 3D-printed prostheses appear to be valuable in orthopedic surgery. However, a larger cohort and longer-term analysis are needed to evaluate the scapular 3D-printed prosthesis as a reliable reconstruction technique.


Subject(s)
Orthopedic Procedures , Scapula , Humans , Printing, Three-Dimensional , Prostheses and Implants , Prosthesis Design , Prosthesis Implantation
15.
Article in English | MEDLINE | ID: mdl-32033480

ABSTRACT

The bio-engineering technologies of medical devices through nano-structuring and coating was recently proposed to improve biocompatibility and to reduce microbial adhesion in the prevention of implantable device-related infections. Our aim was to evaluate the ability of new nano-structured and coated materials to prevent the adhesion and biofilm formation, according to the American Standard Test Method ASTM-E2647-13. The materials composition was determined by X-ray Fluorescence and Laser Induced Breakdown Spectroscopy. Silver release was evaluated by Inductively Coupled Plasma Mass Spectrometry analysis. The gene expression levels of the Quorum Sensing Las and Rhl system were evaluated by the ΔΔCt method. The Log bacterial density (Log CFU/cm2) on TiAl6V4 was 4.41 ± 0.76 and 4.63 ± 1.01 on TiAl6V4-AgNPs compared to 2.57 ± 0.70 on CoCr and 2.73 ± 0.61 on CoCr-AgNPs (P < 0.0001, A.N.O.V.A.- one way test). The silver release was found to be equal to 17.8 ± 0.2 µg/L after the batch phase and 1.3 ± 0.1 µg/L during continuous flow. The rhlR gene resulted in a 2.70-fold increased expression in biofilm growth on the silver nanoparticles (AgNPs) coating. In conclusion, CoCr showed a greater ability to reduce microbial adhesion, independently of the AgNPs coating. The silver release resulted in promoting the up-regulation of the Rhl system. Further investigation should be conducted to optimize the effectiveness of the coating.


Subject(s)
Acrylic Resins/pharmacology , Anti-Bacterial Agents/pharmacology , Bacterial Adhesion/drug effects , Biofilms/drug effects , Joint Prosthesis/microbiology , Metal Nanoparticles/administration & dosage , Silver/pharmacology , Acrylic Resins/administration & dosage , Silver/administration & dosage
16.
Joints ; 6(2): 75-79, 2018 Jun.
Article in English | MEDLINE | ID: mdl-30051101

ABSTRACT

Purpose The aim of this retrospective study was to evaluate the subjective and functional outcome of anterior cruciate ligament (ACL) reconstruction with the synthetic Ligament Advanced Reinforcement System (LARS) ligament. Methods Twenty-six patients were reviewed at an average follow-up of 11.6 years. Objective clinical evaluation was performed with stability tests. Patient-reported outcomes (Visual Analogue Scale, Knee Injury and Osteoarthritis Outcome Score, and Cincinnati Knee Rating Scale) were used to assess subjective and functional outcomes. Results Overall satisfactory results were obtained in 22 cases (84.6%). Four patients (15.4%) showed mechanical failure of the graft. No cases of synovitis or infection were reported. Conclusion LARS ligament can be considered a safe and suitable option for ACL reconstruction in carefully selected cases, especially elderly patients needing a rapid postoperative recovery. Level of Evidence Level IV, retrospective case series.

17.
Orthop Rev (Pavia) ; 10(4): 7715, 2018 Dec 06.
Article in English | MEDLINE | ID: mdl-30662683

ABSTRACT

The purpose was to establish a ranking of the 50 most cited articles about wrist surgery and analyse their features. Science Citation Index Expanded was used to identify the 50 most frequently cited orthopaedic journal articles written in English, searching for the topic "wrist surgery" in the subject category ''Orthopaedics''. Then, we analysed the number of citations, citation density, authorship, article institution, the year of publication, the country of origin of the article, name and impact factor of the journal, and publication type of the article. The 50 most cited articles were published in only 6 of the 74 journals included under the category "orthopaedics". Citation count ranged from 256 for the first one to 67 for the 50th article. Most of them were written by American authors. These articles were published between 1991 and 2011. "Distal Radius Fractures" was the most common issue. This type of bibliographic analysis could be particularly useful for other young Authors who would like to improve their research in wrist and hand surgery and make their publications more citable and appreciated by the scientific community.

18.
Surg Technol Int ; 30: 458-461, 2017 Feb 07.
Article in English | MEDLINE | ID: mdl-28182823

ABSTRACT

Currently, the gold standard to repair large nerve defects is the autologous nerve graft. These solutions offer a mechanical support, adhesion substrates, and, with Schwann cells (SC), a source of neurotropic factors for axonal growth. The technical limits are the donor side damage, multiple surgical accesses, and the unavailability of large amounts of grafts. In recent years, several researchers focused their attention on the interaction between cells (nervous and glial) and physic-chemical cues that arise from the extracellular milieu. Nanotechnologies produce surfaces that mimic the topographical signals (physical stimuli) that arise from enterprise content management (ECM) to modulate the forces acting during axonal elongation. The use of magnetic nanoparticles (MNPs) seems to be able to guide and to boost the nerve regeneration. Both research areas could be improved through surfaces functionalization by biological molecules (proteins/peptides, growth factors, etc.). In the future, the aim will be to help recovery after peripheral nerve lesion by producing a tridimensional structured conduit, then repeat the ECM architecture and take advantage of MNPs internalized by cells and guide them through tension forces by external magnetic fields to stimulate and direct axon growing. The aims of this review were to evaluate the findings of studies that used physical stimuli (nanoscaffold surfaces and MNPs) used for peripheral nerve regeneration support. The future trends in the field of peripheral nerve regeneration continue to produce a wide variety of new techniques to improve the opportunity for advances to treat peripheral nerve injuries.


Subject(s)
Magnetite Nanoparticles , Nerve Regeneration , Peripheral Nerves , Tissue Scaffolds , Animals , Cells, Cultured , Humans , Peripheral Nerve Injuries/physiopathology , Peripheral Nerve Injuries/surgery , Peripheral Nerves/physiology , Peripheral Nerves/surgery , Schwann Cells/cytology
19.
Clin Cases Miner Bone Metab ; 13(3): 221-227, 2016.
Article in English | MEDLINE | ID: mdl-28228786

ABSTRACT

PURPOSE: Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. METHODS: Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. RESULTS: Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. CONCLUSIONS: Concerning the use of porous titanium alloy/hydroxyapatite double coating, this study reported an excellent implant survival rate in a mid-term period with a rate of 1,64% of subsidence in patients with type C of femoral canal but with an optimal HHS and Womac Score results. Regarding this stem, primary stability is guaranteed by trapezoid shape of proximal region and tapering in frontal plane through press-fit technique. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region. Thanks to the reported data, Authors can consider this double coating a valid choice with an excellent medium-term survival and encouraging subsidence results. Further studies are needed to ensure these results can be replicated.

20.
Orthop Rev (Pavia) ; 7(3): 5900, 2015 Sep 28.
Article in English | MEDLINE | ID: mdl-26605028

ABSTRACT

Postoperative spinal wound infection is a potentially devastating complication after operative spinal procedures. Despite the utilization of perioperative prophylactic antibiotics in recent years and improvements in surgical technique and postoperative care, wound infection continues to compromise patients' outcome after spinal surgery. In the modern era of pending health care reform with increasing financial constraints, the financial burden of post-operative spinal infections also deserves consideration. The aim of our work is to give to the reader an updated review of the latest achievements in prevention, risk factors, diagnosis, microbiology and treatment of postoperative spinal wound infections. A review of the scientific literature was carried out using electronic medical databases Pubmed, Google Scholar, Web of Science and Scopus for the years 1973-2012 to obtain access to all publications involving the incidence, risk factors, prevention, diagnosis, treatment of postoperative spinal wound infections. We initially identified 119 studies; of these 60 were selected. Despite all the measures intended to reduce the incidence of surgical site infections in spine surgery, these remain a common and potentially dangerous complication.

SELECTION OF CITATIONS