Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
Gut Liver ; 18(1): 77-84, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38013476

ABSTRACT

Background/Aims: : This study aimed to review the indications, methods, cooperation, complications, and outcomes of percutaneous endoscopic gastrostomy (PEG). Methods: : Questionnaires were sent to 200 hospitals, of which 62 returned their questionnaires, with a response rate of approximately 30%. Descriptive statistics were calculated to analyze the responses to the questionnaires. Results: : In 2019, a total of 1,052 PEGs were performed in 1,017 patients at 62 hospitals. The main group who underwent PEG was older adult patients with brain disease, particularly stroke. Nutritional supply was an important purpose of the PEG procedure. "The pull method" was the most commonly used for initial PEG insertion. The complications related to PEG were mostly mild, with leakage being the most common. Patients who underwent PEG procedures were primarily educated regarding the post-procedure management and complications related to PEG. Preoperative meetings were skipped at >50% of the institutions. Regarding the cooperation between the nutrition support team (NST) and the physician performing PEG, few endoscopists answered that they cooperated with NST before and after PEG. Moreover, the rate of NST certification obtained by physicians performing PEG and the frequency of attendance at NST-related conferences were relatively low. Conclusions: : This study shows a similar trend to that found in the previous PEG guidelines. However, it covers new aspects, including team-based work for PEG procedure, nutrition support, and education for patients and guardians. Therefore, each medical institution needs to select an appropriate method considering the medical environment and doctor's abilities.


Subject(s)
Enteral Nutrition , Gastrostomy , Humans , Aged , Enteral Nutrition/methods , Gastrostomy/methods , Gastroscopy/methods , Surveys and Questionnaires , Republic of Korea , Retrospective Studies
2.
ACS Appl Mater Interfaces ; 14(42): 48072-48080, 2022 Oct 26.
Article in English | MEDLINE | ID: mdl-36222414

ABSTRACT

Graphene inks have recently attracted attention for the development of printed wearable and flexible electronics and sensors not only because of their high conductivity and low cost but also because they are suitable for high-speed printing. Although reliable and scalable printing technologies are well established, further improvement in graphene inks in terms of electrical conductivity, stretchability/flexibility, and mass production is necessary for sensors for real-time monitoring. Herein, highly stretchable and conductive graphene inks were prepared by an efficient and scalable fluid dynamics-assisted exfoliation of graphite and a mixing process with elastomeric Ecoflex. After printing inks onto textile substrates, the serpentine-patterned conductors exhibited high conductivity and stable resistance even under a mechanically stretched state (a strain of 150%). Electrochemical sensors that detect sodium ions were fabricated on this conducting platform. These sensors indicated high potentiometric sensing ability under different mechanical deformations. To demonstrate the on-body performance of the developed sensors, real-time monitoring of sodium-ion concentration in the sweat of a human subject was carried out during an indoor stationary cycling exercise.

3.
Gut Liver ; 16(6): 899-906, 2022 11 15.
Article in English | MEDLINE | ID: mdl-35912649

ABSTRACT

Background/Aims: This study aimed to determine changes in endoscopist-driven sedation practices 5 years after the first nationwide survey in 2014 by the Korean Society of Gastrointestinal Endoscopy (KSGE). Methods: A 59-item survey covering current practices was electronically mailed to all members of the KSGE in 2019. Results: In total, 955 (12.8%) out of 7,486 questionnaires were returned. A total of 738 (77.7%) out of 955 respondents attended dedicated sedation education programs. The American Society of Anesthesiologists class was recorded by 464 (51.2%) out of 907 respondents. The recording rate was higher in respondents who completed sedation education (p=0.014) and worked in general or tertiary hospitals (p<0.001). Compared to that reported in the previous survey, the reported use of propofol was higher in 2019. The respondents had higher satisfaction scores for propofol-based sedation compared with midazolam monotherapy (p<0.001). The rates of oxygen supplementation (p<0.001) and oxygen saturation level monitoring (p<0.001) during sedative endoscopy were higher in 2019 than in the previous survey. A total of 876 (98.4%) out of 890 respondents reported a separate recovery bay, and 615 (70.5%) out of 872 respondents reported that personnel were assigned solely to the recovery bay. Conclusions: Endoscopist-driven sedation and monitoring practices in 2019 were significantly different than those in 2014. The respondents favored propofol-based sedation and utilized oxygen supplementation and monitoring of O2 saturation more frequently in 2019 than in 2014.


Subject(s)
Propofol , Humans , Conscious Sedation , Hypnotics and Sedatives , Endoscopy, Gastrointestinal , Republic of Korea , Surveys and Questionnaires
4.
Clin Endosc ; 55(5): 581-587, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36031764

ABSTRACT

Procedural sedation has become increasingly common in endoscopy. Sedatives and analgesics induce anxiolysis and amnesia. In addition, an appropriate level of sedation is necessary for safe procedures including therapeutic endoscopy. Midazolam and propofol are the most commonly used drugs in sedative endoscopy. In recent years, the need to ascertain the safety and effectiveness of sedation has increased in practice. Therefore, new sedatives and analgesic drugs for optimal sedative endoscopy, have recently emerged. This article reviews the characteristics of sedatives and analgesics, and describes their clinical use in gastrointestinal endoscopy.

5.
Gut Liver ; 16(3): 341-356, 2022 05 15.
Article in English | MEDLINE | ID: mdl-35502587

ABSTRACT

Sedation can resolve anxiety and fear in patients undergoing endoscopy. The use of sedatives has increased in Korea. Appropriate sedation is a state in which the patient feels subjectively comfortable while maintaining the airway reflex for stable spontaneous breathing. The patient should maintain a state of consciousness to the extent that he or she can cooperate with the needs of the medical staff. Despite its benefits, endoscopic sedation has been associated with cardiopulmonary complications. Such cardiopulmonary complications are usually temporary, and most patients recover without sequelae. However, these events may progress to serious complications, such as cardiovascular collapse. Therefore, it is essential to screen high-risk patients before sedation and reduce complications by meticulous monitoring. Additionally, physicians should be familiar with the management of emergencies. The first Korean clinical practice guideline for endoscopic sedation was developed based on previous worldwide guidelines for endoscopic sedation using an adaptation process. The guideline consists of nine recommendations based on a critical review of currently available data and expert consensus when the guideline was drafted. These guidelines should provide clinicians, nurses, medical school students, and policy makers with information on how to perform endoscopic sedation with minimal risk.


Subject(s)
Endoscopy, Gastrointestinal , Hypnotics and Sedatives , Conscious Sedation , Female , Humans , Republic of Korea
6.
Korean J Gastroenterol ; 79(4): 141-155, 2022 04 25.
Article in Korean | MEDLINE | ID: mdl-35473772

ABSTRACT

Sedation can resolve anxiety and fear in patients undergoing endoscopy. The use of sedatives has increased in Korea. Appropriate sedation is a state in which the patient feels subjectively comfortable while maintaining the airway reflex for stable spontaneous breathing. The patient should maintain a state of consciousness to the extent that he or she can cooperate with the needs of the medical staff. Despite its benefits, endoscopic sedation has been associated with cardiopulmonary complications. Cardiopulmonary complications are usually temporary. Most patients recover without sequelae. However, they may progress to serious complications, such as cardiovascular collapse. Therefore, it is essential to screen high-risk patients before sedation and reduce complications by meticulous monitoring. Additionally, physicians should be familiar with the management of emergencies. The first Korean clinical practice guideline for endoscopic sedation was developed based on previous worldwide guidelines for endoscopic sedation using an adaptation process. The guideline consists of nine recommendations based on a critical review of currently available data and expert consensus when the guideline was drafted. These guidelines should provide clinicians, nurses, medical school students, and policy makers with information on how to perform endoscopic sedation with minimal risk.


Subject(s)
Conscious Sedation , Endoscopy, Gastrointestinal , Endoscopy, Gastrointestinal/adverse effects , Humans , Hypnotics and Sedatives/therapeutic use , Republic of Korea
7.
Investig Clin Urol ; 63(2): 126-139, 2022 03.
Article in English | MEDLINE | ID: mdl-35244986

ABSTRACT

PURPOSE: To evaluate the clinical efficacy and safety of tumor enucleation (TE) compared with partial nephrectomy (PN) for T1 renal cell carcinoma. MATERIALS AND METHODS: According to protocol, we searched multiple data sources for published and unpublished randomized controlled trials and nonrandomized studies (NRSs) in any language. We performed systematic review and meta-analysis according to the Cochrane Handbook for Systematic Reviews of Interventions and rated the certainty of the evidence (CoE) using the GRADE framework. RESULTS: We are uncertain about the effects of TE on perioperative (mean difference [MD] 3.38, 95% CI 1.52 to 5.23; I²=68%; 4 NRSs; 942 participants; very low CoE) and long-term (MD 2.31, 95% CI -1.40 to 6.01; I²=57%; 4 NRSs; 542 participants; very low CoE) residual renal function. TE may result in little to no difference in short-term residual renal function (MD 1.04, 95% CI 0.25 to 1.83; I²=0%; 2 NRSs; 256 participants; low CoE). We are uncertain about the effects of TE on cancer-specific mortality (risk ratio [RR] 0.90, 95% CI: 0.11 to 7.28; I²=0%; 2 NRSs; 551 participants; very low CoE) and major adverse events (RR 0.48, 95% CI: 0.30 to 0.79; I²=0%; 10 NRS; 2,360 participants; very low CoE). CONCLUSIONS: While TE appears to have similar effects on short term postoperative residual renal function, there were uncertainties on mortality and major adverse events. However, we need rigorous RCTs to elucidate the effects of TE as the evidence stems mostly from NRSs.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Carcinoma, Renal Cell/surgery , Disease Progression , Female , Humans , Kidney Neoplasms/surgery , Male , Nephrectomy/adverse effects , Postoperative Period
8.
Clin Endosc ; 55(2): 167-182, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35189678

ABSTRACT

Sedation can resolve anxiety and fear in patients undergoing endoscopy. The use of sedatives has increased in Korea. Appropriate sedation is a state in which the patient feels subjectively comfortable while maintaining the airway reflex for stable spontaneous breathing. The patient should maintain a state of consciousness to the extent that he or she can cooperate with the needs of the medical staff. Despite its benefits, endoscopic sedation has been associated with cardiopulmonary complications. Cardiopulmonary complications are usually temporary. Most patients recover without sequelae. However, they may progress to serious complications, such as cardiovascular collapse. Therefore, it is essential to screen high-risk patients before sedation and reduce complications by meticulous monitoring. Additionally, physicians should be familiar with the management of emergencies. The first Korean clinical practice guideline for endoscopic sedation was developed based on previous worldwide guidelines for endoscopic sedation using an adaptation process. The guideline consists of nine recommendations based on a critical review of currently available data and expert consensus when the guideline was drafted. These guidelines should provide clinicians, nurses, medical school students, and policy makers with information on how to perform endoscopic sedation with minimal risk.

9.
Gut Liver ; 16(4): 555-566, 2022 07 15.
Article in English | MEDLINE | ID: mdl-34789583

ABSTRACT

Background/Aims: Inflammatory bowel disease (IBD) is associated with the occurrence of venous thromboembolism (VTE). However, to date, there have been few studies on the risk of VTE in Asian IBD patients. We aimed to estimate the incidence of VTE in Asian IBD patients and to determine if IBD is related to increased VTE risk. Methods: We performed a population-based cohort study between 2004 and 2015 using Korean National Health Insurance data. IBD and VTE were defined by ICD-10 codes. Incidence rates of VTE were calculated among patients with IBD and among age- and sex-matched controls. Hazard ratios were estimated using Cox regression with adjustment for multiple variables. We performed additional analyses stratifying by age, sex, Charlson comorbidity index (CCI) score, and disease type. Results: Among the 45,037 patients with IBD (IBD cohort) and 133,019 matched controls (non-IBD cohort) included in our analysis, 411 IBD patients and 641 controls developed VTE. The IBD cohort had a higher incidence rate ratio and risk of VTE than the non-IBD cohort (incidence rate ratio: 1.92 and hazard ratio: 1.93). Older age, female sex, higher CCI scores, cardiovascular disease, chronic kidney disease, use of steroids, and hospitalization were significant risk factors for VTE in patients with IBD. Conclusions: The IBD patients in this study were approximately two times more likely to develop VTE than the non-IBD individuals. Our findings support the need for thromboprophylaxis in Asian IBD patients with various factors that further increase the risk of VTE.


Subject(s)
Inflammatory Bowel Diseases , Venous Thromboembolism , Anticoagulants/therapeutic use , Chronic Disease , Cohort Studies , Female , Humans , Incidence , Inflammatory Bowel Diseases/complications , Inflammatory Bowel Diseases/drug therapy , Inflammatory Bowel Diseases/epidemiology , Risk Factors , Venous Thromboembolism/epidemiology , Venous Thromboembolism/etiology , Venous Thromboembolism/prevention & control
10.
Gut Liver ; 2021 Jun 25.
Article in English | MEDLINE | ID: mdl-34162769

ABSTRACT

BACKGROUND/AIMS: : Endoscopic submucosal dissection (ESD) is a curative treatment modality for early gastric neoplasms; however, ESD can be a time-consuming process. To overcome this pitfall, we developed the one-step knife (OSK) approach, which combines an endoscopic knife and injection needle on a single sheath. We aimed to evaluate whether this approach could reduce the ESD procedure time. METHODS: This single-blinded randomized multicenter trial at four tertiary hospitals from June 2019 to June 2020 included patients aged 19 to 85 years undergoing ESD. Patients were randomly assigned to two groups (OSK or conventional knife [CK]). The injection time, total procedure time, resected specimen size, submucosal fluid amount, degree of device satisfaction, and adverse events were evaluated and compared between groups. RESULTS: Fifty-one patients were analyzed (OSK: 25 patients and CK: 26 patients). No baseline differences were observed between groups, with the exception of a higher portion of males in the OSK group. The mean injection time was significantly reduced in the OSK group (39.0 seconds) compared to that in the CK group (87.5 seconds, p<0.001). A decrease of more than 10 minutes in the total procedure time (18.0 minutes vs 28.1 minutes, p=0.055) in the OSK group compared to the CK group was observed. Second-look esophagogastroduodenoscopy revealed two delayed bleeding cases in the OSK group that were easily controlled by endoscopic hemostasis. CONCLUSIONS: OSK reduced the injection time and showed a decrease in total procedure time compared with the CK approach. OSK can be a feasible tool for ESD, especially in difficult cases.

11.
J Clin Med ; 10(11)2021 May 27.
Article in English | MEDLINE | ID: mdl-34072225

ABSTRACT

Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as reference, the discrepancy percent (DP), error rate (ER), and measurement time were compared between gCAP and visual estimation (VE) after randomization. ER was calculated within a 20% and 33% limit. From the 111 patients, 280 polyps were measured. The mean polyp sizes were 4.0 ± 1.7 mm and 4.2 ± 1.8 mm with gCAP and VE, respectively (p = 0.368). Compared with that by the forceps method, DP was significantly lower in the gCAP group than in the VE group. Moreover, ER was significantly lower in the gCAP group within its preset limit. The measurement time was 4 s longer in the gCAP group than in the VE group (8.2 ± 4.8 s vs. 4.2 ± 1.5 s; p < 0.001). However, the forceps method lasted 28 s longer than the others. On subgroup analysis by size, gCAP was more accurate for polyp size ≥ 5 mm. The gCAP method was more accurate for polyp size measurement than VE, especially for polyps ≥ 5 mm, and was more convenient than the forceps method.

12.
Nanomicro Lett ; 13(1): 87, 2021 Mar 08.
Article in English | MEDLINE | ID: mdl-34138339

ABSTRACT

HIGHLIGHTS: Ultrathin and defect-free graphene ink is prepared through a high-throughput fluid dynamics process, resulting in a high exfoliation yield (53.5%) and a high concentration (47.5 mg mL-1). A screen-printed graphene conductor exhibits a high electrical conductivity of 1.49 × 104 S m-1 and good mechanical flexibility. An electrochemical sodium ion sensor based on graphene ink exhibits an excellent potentiometric sensing performance in a mechanically bent state. Real-time monitoring of sodium ion concentration in sweat is demonstrated. Conductive inks based on graphene materials have received significant attention for the fabrication of a wide range of printed and flexible devices. However, the application of graphene fillers is limited by their restricted mass production and the low concentration of their suspensions. In this study, a highly concentrated and conductive ink based on defect-free graphene was developed by a scalable fluid dynamics process. A high shear exfoliation and mixing process enabled the production of graphene at a high concentration of 47.5 mg mL-1 for graphene ink. The screen-printed graphene conductor exhibits a high electrical conductivity of 1.49 × 104 S m-1 and maintains high conductivity under mechanical bending, compressing, and fatigue tests. Based on the as-prepared graphene ink, a printed electrochemical sodium ion (Na+) sensor that shows high potentiometric sensing performance was fabricated. Further, by integrating a wireless electronic module, a prototype Na+-sensing watch is demonstrated for the real-time monitoring of the sodium ion concentration in human sweat during the indoor exercise of a volunteer. The scalable and efficient procedure for the preparation of graphene ink presented in this work is very promising for the low-cost, reproducible, and large-scale printing of flexible and wearable electronic devices.

13.
Gut Liver ; 15(6): 841-850, 2021 11 15.
Article in English | MEDLINE | ID: mdl-33827990

ABSTRACT

Background/Aims: : The mucoprotective drug rebamipide is used to treat gastritis and peptic ulcers. We compared the efficacy of MucostaⓇ (rebamipide 100 mg) and its new formulation, AD-203 (rebamipide 150 mg), in treating erosive gastritis. Methods: This double-blind, active control, noninferiority, multicenter, phase 3 clinical trial randomly assigned 475 patients with endoscopically proven erosive gastritis to two groups: AD-203 twice daily or MucostaⓇ thrice daily for 2 weeks. The intention-to-treat (ITT) analysis included 454 patients (AD-203, n=229; MucostaⓇ, n=225), and the per-protocol (PP) analysis included 439 patients (AD-203, n=224; MucostaⓇ, n=215). The posttreatment assessments included the primary (erosion improvement rate) and secondary endpoints (erosion and edema cure rates; improvement rates of redness, hemorrhage, and gastrointestinal symptoms). Drug-related adverse events were evaluated. Results: According to the ITT analysis, the erosion improvement rates (posttreatment) in AD-203-treated and MucostaⓇ-treated patients were 39.7% and 43.8%, respectively. According to the PP analysis, the erosion improvement rates (posttreatment) in AD-203-treated and MucostaⓇ-treated patients were 39.3% and 43.7%, respectively. The one-sided 97.5% lower limit for the improvement rate difference between the study groups was -4.01% (95% confidence interval [CI], -13.09% to 5.06%) in the ITT analysis and -4.44% (95% CI, -13.65% to 4.78%) in the PP analysis. The groups did not significantly differ in the secondary endpoints in either analysis. Twenty-four AD-203-treated and 20 MucostaⓇ-treated patients reported adverse events but no serious adverse drug reactions; both groups presented similar adverse event rates. Conclusions: The new formulation of rebamipide 150 mg (AD-203) twice daily was not inferior to rebamipide 100 mg (MucostaⓇ) thrice daily. Both formulations showed a similar efficacy in treating erosive gastritis.


Subject(s)
Gastritis , Quinolones , Stomach Ulcer , Alanine/analogs & derivatives , Double-Blind Method , Gastritis/drug therapy , Humans , Quinolones/adverse effects , Treatment Outcome
14.
Clin Transl Gastroenterol ; 12(5): e00350, 2021 04 30.
Article in English | MEDLINE | ID: mdl-33928919

ABSTRACT

INTRODUCTION: Use of colonoscopy or the fecal immunochemical test (FIT) for colorectal cancer (CRC) prevention is supported by previous studies. However, there is little specific evidence regarding comparative effectiveness of colonoscopy or FIT for reducing CRC risk. In this study, we compared the association of CRC risk with colonoscopy and FIT using a nationwide database. METHODS: This population-based case-control study used colonoscopy and FIT claims data from the Korean National Health Insurance System from 2002 to 2013. Data were analyzed from 61,221 patients with newly diagnosed CRC (case group) and 306,099 individuals without CRC (control group). Multivariable logistic regression models were used to evaluate the association between CRC and colonoscopy or FIT. RESULTS: Colonoscopy was associated with a reduced subsequent CRC risk (adjusted odds ratio [OR] 0.29). Stronger associations were found between colonoscopy and distal CRC, compared with proximal CRC (0.24 vs 0.47). In an analysis stratified by sex, the association was weaker in female subjects compared with male subjects (0.33 vs 0.27). Any FIT exposure was associated with CRC risk with an OR of 0.74; this association was stronger for distal cancer. As the frequency of cumulative FIT assessments increased (from 1 to ≥5), the OR of FIT exposure for CRC gradually decreased from 0.81 to 0.45. DISCUSSION: The association of colonoscopy or FIT with reduced CRC risk was stronger for distal CRC than for proximal CRC. FIT showed less CRC risk reduction than colonoscopy. However, as the frequency of cumulative FIT assessments increased, the association with CRC prevention became stronger.


Subject(s)
Colonoscopy , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/prevention & control , Early Detection of Cancer/methods , Immunochemistry , Mass Screening/methods , Aged , Asian People , Case-Control Studies , Colorectal Neoplasms/ethnology , Feces , Female , Humans , Male , Middle Aged , Occult Blood , Republic of Korea , Risk Factors
15.
J Clin Med ; 9(10)2020 Oct 13.
Article in English | MEDLINE | ID: mdl-33066213

ABSTRACT

BACKGROUND: Sedation endoscopy increases patient and examiner satisfaction but involves complications. The most serious complication is hypoxia, the risk factors for which are old age, obesity, and American Society of Anesthesiologists physical status of 3 or greater. However, clear evidence of oxygenation during sedation endoscopy for elderly people is lacking in US, European, and Korean guidelines. METHOD: This study was conducted for 1 year starting in August 2018 to evaluate whether pre-oxygenation use 1 min before sedation endoscopy could reduce the incidence of hypoxia in patients older than 65 years of age. A total of 70 patients were divided into the non-oxygenated group (n = 35; control group) and oxygen-treated group (n = 35; experimental group) during endoscopy. RESULT: The incidence of hypoxia was 28 (80%) in the control group versus 0 (0%) in the pre-oxygenated group. Factors related to hypoxia in the non-oxygenated group were a relatively high dose of midazolam and concomitant injection with narcotic analgesics such as pethidine. CONCLUSION: The incidence of hypoxia during sedation endoscopy is high in patients over 65 years, but oxygenation during endoscopic sedation in elderly people can significantly reduce the incidence of intraprocedural hypoxic events.

16.
Am J Gastroenterol ; 115(3): 465-472, 2020 03.
Article in English | MEDLINE | ID: mdl-31972618

ABSTRACT

OBJECTIVES: Some neoplastic lesions remain undetected on colonoscopy. To date, no studies have investigated whether combining cap-assisted colonoscopy with chromoendoscopy increases the adenoma detection rate (ADR). This study aimed to compare cap-assisted chromoendoscopy (CAP/CHROMO) with standard colonoscopy (SC) with respect to their efficacy in detecting adenomas. METHODS: This prospective, multicenter, randomized controlled trial included asymptomatic subjects aged 45-75 years who underwent colonoscopy for the first time at 14 university hospitals. Subjects were randomized to either the CAP/CHROMO group (with 0.09% indigo carmine spraying using a cap-mounted catheter at the tip of the colonoscope) or the SC group. All polyps were resected, but only histologically confirmed neoplastic lesions were considered for analysis. The primary outcome was ADR, defined as the proportion of subjects with at least 1 adenoma. RESULTS: A total of 1,905 subjects were randomized to the CAP/CHROMO (n = 948) or SC (n = 957) group at 14 centers. Subjects' demographic characteristics were similar between both groups. The CAP/CHROMO group had significantly higher ADR than the SC group (54.4% vs 44.9%, P < 0.001). Significantly, more subjects with at least 1 proximal colon adenoma were identified by CAP/CHROMO (38.6%) than by SC (31.2%) (P = 0.001). The proximal serrated polyp detection rate by CAP/CHROMO was significantly higher in the female subgroup vs SC. However, advanced ADR was not different between the CAP/CHROMO and SC groups (9.3% vs 7.6%, P = 0.180). DISCUSSION: CAP/CHROMO markedly improved the ADR and enhanced the detection of proximal adenoma. CAP/CHROMO is feasible for routine application and will allow for a more effective surveillance program.


Subject(s)
Adenoma/diagnostic imaging , Colonic Neoplasms/diagnostic imaging , Colonoscopes , Colonoscopy/methods , Early Detection of Cancer/methods , Optical Imaging/methods , Aged , Colonoscopy/instrumentation , Early Detection of Cancer/instrumentation , Female , Humans , Male , Middle Aged , Optical Imaging/instrumentation , Prospective Studies
17.
Biosens Bioelectron ; 150: 111946, 2020 Feb 15.
Article in English | MEDLINE | ID: mdl-31929084

ABSTRACT

Development of sensing technology with wearable chemical sensors is realizing non-invasive, real-time monitoring healthcare and disease diagnostics. The advanced sensor devices should be compact and portable for use in limited space, easy to wear on human body, and low-cost for personalized healthcare markets. Here, we report a highly sensitive, flexible, and autonomously self-healable pH sensor cable developed by weaving together two carbon fiber thread electrodes coated with mechanically robust self-healing polymers. The pH sensor cable showed excellent electrochemical performances of sensitivity, repeatability, and durability. Spontaneous and autonomous sensor healing efficiency of the pH sensor cable was demonstrated by measuring sensitivity during four cycles of cutting and healing process. The pH sensor cable could measure pH in small volumes of real human fluid samples, including urine, saliva, and sweat, and the results were similar to those of a commercial pH meter. Taken together, successful real-time pH monitoring for human sweat was demonstrated by fabricating a wearable sensing system in which the pH sensor cable was knitted into a headband integrated with wireless electronics.


Subject(s)
Biosensing Techniques/instrumentation , Saliva/chemistry , Sweat/chemistry , Urine/chemistry , Wearable Electronic Devices , Carbon Fiber/chemistry , Electrodes , Equipment Design , Humans , Hydrogen-Ion Concentration , Polymers/chemistry
18.
J Colloid Interface Sci ; 560: 817-824, 2020 Feb 15.
Article in English | MEDLINE | ID: mdl-31711668

ABSTRACT

In this study, ultrathin and defect-free graphene (Gr) sheets were prepared through a fluid dynamics-induced shear exfoliation method using graphite. The high hydrophobicity and surface area of Gr make it attractive as a solid-contact ion-to-electron transducer for potentiometric K+ sensors, in which the electrodes are fabricated through a screen-printing process. The electrochemical characterization demonstrates that Gr solid contact results in a high double-layer capacitance, potential stability, and strong resistance against water layer, gases, and light. The Gr-based K+ sensors showed a Nernstian slope of 53.53 mV/log[K+] within a linear concentration range of 10-1-10-4 M, a low detection limit of 10-4.28 M, a fast response time of ~8 s, good repeatability, and excellent long-term stability. Moreover, the Gr-based K+ sensors provided accurate ion concentrations in actual samples of human sweat and sports drinks.


Subject(s)
Biosensing Techniques/instrumentation , Electrochemistry/instrumentation , Electrodes , Graphite/chemistry , Potassium/analysis , Potentiometry/methods , Sweat/metabolism , Electric Capacitance , Energy Drinks/analysis , Humans , Hydrophobic and Hydrophilic Interactions , Potentiometry/instrumentation , Transducers
19.
ACS Appl Mater Interfaces ; 11(49): 46165-46175, 2019 Dec 11.
Article in English | MEDLINE | ID: mdl-31774642

ABSTRACT

Sensors with autonomous self-healing properties offer enhanced durability, reliability, and stability. Although numerous self-healing polymers have been attempted, achieving sensors with fast and reversible recovery under ambient conditions with high mechanical toughness remains challenging. Here, a highly sensitive wearable sensor made of a robust bio-based supramolecular polymer that is capable of self-healing via hydrogen bonding is presented. The integration of carbon fiber thread into a self-healing polymer matrix provides a new toolset that can easily be knitted into textile items to fabricate wearable sensors that show impressive self-healing efficiency (>97.0%) after 30 s at room temperature for K+/Na+ sensing. The wearable sweat-sensor system-coupled with a wireless electronic circuit board capable of transferring data to a smart phone-successfully monitors electrolyte ions in human perspiration noninvasively in real time, even in the healed state during indoor exercise. Our smart sensors represent an important advance toward futuristic personalized healthcare applications.


Subject(s)
Biosensing Techniques , Electrolytes/isolation & purification , Ions/isolation & purification , Sweat/chemistry , Electrolytes/chemistry , Humans , Hydrogen Bonding , Ions/chemistry , Monitoring, Physiologic/methods , Polymers/chemistry , Smartphone , Textiles , Wearable Electronic Devices
20.
Nano Converg ; 6(1): 9, 2019 Mar 18.
Article in English | MEDLINE | ID: mdl-30880366

ABSTRACT

We report potentiometric performance of a polyaniline nanofiber array-based pH sensor fabricated by combining a dilute chemical polymerization and low-cost and simple screen printing process. The pH sensor had a two-electrode configuration consisting of polyaniline nanofiber array sensing electrode and Ag/AgCl reference electrode. Measurement of electromotive force between sensing and reference electrodes provided various electrochemical properties of pH sensors. The pH sensor show excellent sensor performances of sensitivity of 62.4 mV/pH, repeatability of 97.9% retention, response time of 12.8 s, and durability of 3.0 mV/h. The pH sensor could also measure pH changes as the milk is spoiled, which is similar to those of a commercial pH meter. The pH sensors were highly flexible, and thus can measure the fruit decay on the curved surface of an apple. This flexible and miniature pH sensor opens new opportunities for monitoring of water, product process, human health, and chemical (or bio) reactions even using small volumes of samples.

SELECTION OF CITATIONS
SEARCH DETAIL
...