ABSTRACT

We have conducted global positioning system (GPS) carrier-phase time-transfer experiments between the master clock (MC) at the U.S. Naval Observatory (USNO) in Washington, DC and the alternate master clock (AMC) at Schriever Air Force Base near Colorado Springs, Colorado. These clocks are also monitored on an hourly basis with two-way satellite time-transfer (TWSTT) measurements. We compared the performance of the GPS carrier phase and TWSTT systems over a 236-d period. Because of power problems and data outages during the carrier-phase experiment, the longest continuous time span is 96 d. The data from this period show agreement with TWSTT within +/-1 ns, apart from an overall constant time offset (caused by unknown delays in the GPS hardware at both ends). For averaging times of a day, the carrier-phase and TWSTT systems have a frequency uncertainty of 2.5 and 5.5 parts in 10(15), respectively.