Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 24(3)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38339659

ABSTRACT

Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.

2.
Sensors (Basel) ; 23(13)2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37448076

ABSTRACT

Pixelated low-gain avalanche diodes (LGADs) can provide both precision spatial and temporal measurements for charged particle detection; however, electrical termination between the pixels yields a no-gain region, such that the active area or fill factor is not sufficient for small pixel sizes. Trench-isolated LGADs (TI-LGADs) are a strong candidate for solving the fill-factor problem, as the p-stop termination structure is replaced by isolated trenches etched in the silicon itself. In the TI-LGAD process, the p-stop termination structure, typical of LGADs, is replaced by isolating trenches etched in the silicon itself. This modification substantially reduces the size of the no-gain region, thus enabling the implementation of small pixels with an adequate fill factor value. In this article, a systematic characterization of the TI-RD50 production, the first of its kind entirely dedicated to the TI-LGAD technology, is presented. Designs are ranked according to their measured inter-pixel distance, and the time resolution is compared against the regular LGAD technology.


Subject(s)
Silicon
3.
Med Phys ; 50(9): 5817-5827, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37493525

ABSTRACT

BACKGROUND: The beam energy is one of the most significant parameters in particle therapy since it is directly correlated to the particles' penetration depth inside the patient. Nowadays, the range accuracy is guaranteed by offline routine quality control checks mainly performed with water phantoms, 2D detectors with PMMA wedges, or multi-layer ionization chambers. The latter feature low sensitivity, slow collection time, and response dependent on external parameters, which represent limiting factors for the quality controls of beams delivered with fast energy switching modalities, as foreseen in future treatments. In this context, a device based on solid-state detectors technology, able to perform a direct and absolute beam energy measurement, is proposed as a viable alternative for quality assurance measurements and beam commissioning, paving the way for online range monitoring and treatment verification. PURPOSE: This work follows the proof of concept of an energy monitoring system for clinical proton beams, based on Ultra Fast Silicon Detectors (featuring tenths of ps time resolution in 50 µm active thickness, and single particle detection capability) and time-of-flight techniques. An upgrade of such a system is presented here, together with the description of a dedicated self-calibration method, proving that this second prototype is able to assess the mean particles energy of a monoenergetic beam without any constraint on the beam temporal structure, neither any a priori knowledge of the beam energy for the calibration of the system. METHODS: A new detector geometry, consisting of sensors segmented in strips, has been designed and implemented in order to enhance the statistics of coincident protons, thus improving the accuracy of the measured time differences. The prototype was tested on the cyclotron proton beam of the Trento Protontherapy Center (TPC). In addition, a dedicated self-calibration method, exploiting the measurement of monoenergetic beams crossing the two telescope sensors for different flight distances, was introduced to remove the systematic uncertainties independently from any external reference. RESULTS: The novel calibration strategy was applied to the experimental data collected at TPC (Trento) and CNAO (Pavia). Deviations between measured and reference beam energies in the order of a few hundreds of keV with a maximum uncertainty of 0.5 MeV were found, in compliance with the clinically required water range accuracy of 1 mm. CONCLUSIONS: The presented version of the telescope system, minimally perturbative of the beam, relies on a few seconds of acquisition time to achieve the required clinical accuracy and therefore represents a feasible solution for beam commission, quality assurance checks, and online beam energy monitoring.


Subject(s)
Proton Therapy , Calibration , Proton Therapy/standards , Time Factors , Humans
4.
Sensors (Basel) ; 23(2)2023 Jan 11.
Article in English | MEDLINE | ID: mdl-36679653

ABSTRACT

Recent years have witnessed a growing interest in detectors capable of detecting single photons in the near-infrared (NIR), mainly due to the emergence of new applications such as light detection and ranging (LiDAR) for, e.g., autonomous driving. A silicon single-photon avalanche diode is surely one of the most interesting and available technologies, although it yields a low efficiency due to the low absorption coefficient of Si in the NIR. Here, we aim at overcoming this limitation through the integration of complementary metal-oxide-semiconductor (CMOS) -compatible nanostructures on silicon photodetectors. Specifically, we utilize silver grating arrays supporting surface plasmons polaritons (SPPs) to superficially confine the incoming NIR photons and therefore to increase the probability of photons generating an electron-hole pair. First, the plasmonic silver array is geometrically designed using time domain simulation software to achieve maximum detector performance at 950 nm. Then, a plasmonic silver array characterized by a pitch of 535 nm, a dot width of 428 nm, and a metal thickness of 110 nm is integrated by means of the focused ion beam technique on the detector. Finally, the integrated detector is electro-optically characterized, demonstrating a QE of 13% at 950 nm, 2.2 times higher than the reference. This result suggests the realization of a silicon device capable of detecting single NIR photons, at a low cost and with compatibility with standard CMOS technology platforms.


Subject(s)
Automobile Driving , Nanostructures , Silver , Silicon , Computer Simulation , Oxides
5.
Article in English | MEDLINE | ID: mdl-34769732

ABSTRACT

In this paper, an in-depth and systematic study of the radiological characterization of three types of Puglia region natural limestones (Pietra Leccese, Pietra Mazzara and Carparo) was carried out. The investigation was performed by XRF spectroscopy for a chemical analysis, and gamma spectroscopy of the specific activity concentration of natural radionuclides 226Ra, 232Th, and 40K. Although the limestone does not fall within the category included by Italian Legislative Decree 101/2020, the gamma index was calculated using the results of the gamma spectroscopy measurements. For Pietra Mazzara and Carparo stones, the gamma index was found to be less than the reference value; conversely Pietra Leccese was found to be higher. To obtain a more complete evaluation of the external exposure, radium equivalent activity and external radiation hazard were calculated for all analyzed stones. The results suggest the need to broadly consider the radiological risk for these stones, and for limestone more generally, when used as a building material.


Subject(s)
Radiation Monitoring , Radiation Protection , Radium , Background Radiation , Construction Materials , Potassium Radioisotopes/analysis , Radiation Dosage , Radium/analysis , Spectrometry, Gamma , Thorium/analysis
6.
J Synchrotron Radiat ; 26(Pt 4): 1226-1237, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31274448

ABSTRACT

Recent advances in segmented low-gain avalanche detectors (LGADs) make them promising for the position-sensitive detection of low-energy X-ray photons thanks to their internal gain. LGAD microstrip sensors fabricated by Fondazione Bruno Kessler have been investigated using X-rays with both charge-integrating and single-photon-counting readout chips developed at the Paul Scherrer Institut. In this work it is shown that the charge multiplication occurring in the sensor allows the detection of X-rays with improved signal-to-noise ratio in comparison with standard silicon sensors. The application in the tender X-ray energy range is demonstrated by the detection of the sulfur Kα and Kß lines (2.3 and 2.46 keV) in an energy-dispersive fluorescence spectrometer at the Swiss Light Source. Although further improvements in the segmentation and in the quantum efficiency at low energy are still necessary, this work paves the way for the development of single-photon-counting detectors in the soft X-ray energy range.

8.
Sensors (Basel) ; 19(2)2019 Jan 14.
Article in English | MEDLINE | ID: mdl-30646553

ABSTRACT

Different applications require different customizations of silicon photomultiplier (SiPM) technology. We present a review on the latest SiPM technologies developed at Fondazione Bruno Kessler (FBK, Trento), characterized by a peak detection efficiency in the near-UV and customized according to the needs of different applications. Original near-UV sensitive, high-density SiPMs (NUV-HD), optimized for Positron Emission Tomography (PET) application, feature peak photon detection efficiency (PDE) of 63% at 420 nm with a 35 um cell size and a dark count rate (DCR) of 100 kHz/mm². Correlated noise probability is around 25% at a PDE of 50% at 420 nm. It provides a coincidence resolving time (CRT) of 100 ps FWHM (full width at half maximum) in the detection of 511 keV photons, when used for the readout of LYSO(Ce) scintillator (Cerium-doped lutetium-yttrium oxyorthosilicate) and down to 75 ps FWHM with LSO(Ce:Ca) scintillator (Cerium and Calcium-doped lutetium oxyorthosilicate). Starting from this technology, we developed three variants, optimized according to different sets of specifications. NUV-HD⁻LowCT features a 60% reduction of direct crosstalk probability, for applications such as Cherenkov telescope array (CTA). NUV-HD⁻Cryo was optimized for cryogenic operation and for large photosensitive areas. The reference application, in this case, is the readout of liquid, noble-gases scintillators, such as liquid Argon. Measurements at 77 K showed a remarkably low value of the DCR of a few mHz/mm². Finally, vacuum-UV (VUV)-HD features an increased sensitivity to VUV light, aiming at direct detection of photons below 200 nm. PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.

SELECTION OF CITATIONS
SEARCH DETAIL
...