Results 1 - 20 de 23
Filter
1.
J Cardiovasc Magn Reson ; 22(1): 31, 2020 05 07.
Article in English | MEDLINE | ID: mdl-32375896

ABSTRACT

BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/standards , Phantoms, Imaging/standards , Consensus , Humans , Observer Variation , Predictive Value of Tests , Reproducibility of Results
2.
Nucl Med Commun ; 40(8): 815-826, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31169592

ABSTRACT

OBJECTIVE: To construct a mediastinal-specific fluorine-18-fluorodeoxyglucose (F-FDG)-PET/MR protocol with high-quality MRI of minimal acquisition-time and comparable diagnostic value to F-FDG-PET/computed tomography (CT). MATERIALS AND METHODS: Fifteen healthy participants received PET/MRI and 10 patients with mediastinal tumours (eight non-small-cell lung, two oesophageal cancer) received F-FDG-PET/MRI immediately after F-FDG-PET/CT. Sequences volume interpolated breath-hold examination (T1-VIBE) and Half-Fourier acquisition single-shot turbo spin echo (T2-HASTE) were optimised by varying the parameters: breath-hold (BH, end-expiration), fat suppression (spectral adiabatic inversion recovery), and ECG-triggering (ECG, end-diastole). Image quality (IQ) of each sequence-variation was qualitatively scored by medical experts and quantitatively assessed by calculating signal-to-noise ratios, contrast relative to muscle, standardized-uptake-value, and tumour-to-blood ratios. Patient comfort was evaluated on patients' experience. Diagnostic accuracy of F-FDG-PET/MRI was compared to F-FDG-PET/CT, in reference to histopathology/cytopathology. RESULTS: ECG-triggered T1-VIBE images showed the highest signal-to-noise ratio (P < 0.01) and the largest contrast between mediastinal soft-tissues, regardless of BH or free-breathing acquisition. IQ of ECG-triggered T1-VIBE scans in BH were scored qualitatively highest with good reader agreement (κ = 0.62). IQ of T2-HASTE was not significantly affected by BH acquisition (P > 0.9). Qualitative IQ of T1-VIBE and T2-HASTE declined after spectral adiabatic inversion recovery fat-suppression. All patients could maintain BH at end-expiration and reported no discomfort. Diagnostic performance of F-FDG-PET/MR was not significantly different from F-FDG-PET/CT with comparable staging, standardized-uptake-values, and tumour-to-blood ratios. However, T-status was more often over-staged on F-FDG-PET/CT, while N-status was more frequently under-staged on F-FDG-PET/MR. CONCLUSION: ECG-triggered T1-VIBE sequences acquired during short, multiple BHs are recommended for mediastinal imaging using F-FDG-PET/MR. With dedicated protocols, F-FDG-PET/MRI will be useful in thoracic oncology and aid in diagnostic evaluation and tailored treatment decision-making.


Subject(s)
Fluorodeoxyglucose F18 , Magnetic Resonance Imaging/methods , Mediastinum/diagnostic imaging , Multimodal Imaging/methods , Positron-Emission Tomography/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Mediastinal Neoplasms/diagnostic imaging , Middle Aged
3.
J Vasc Interv Radiol ; 30(5): 701-708.e1, 2019 May.
Article in English | MEDLINE | ID: mdl-30952523

ABSTRACT

PURPOSE: To evaluate conditions for minimizing staff dose in interventional radiology, and to provide an achievable level for radiation exposure reduction. MATERIALS AND METHODS: Comprehensive phantom experiments were performed in an angiography suite to evaluate the effects of several parameters on operator dose, such as patient body part, radiation shielding, x-ray tube angulation, and acquisition type. Phantom data were compared with operator dose data from clinical procedures (n = 281), which were prospectively acquired with the use of electronic real-time personal dosimeters (PDMs) combined with an automatic dose-tracking system (DoseWise Portal; Philips, Best, The Netherlands). A reference PDM was installed on the C-arm to measure scattered radiation. Operator exposure was calculated relative to this scatter dose. RESULTS: In phantom experiments and clinical procedures, median operator dose relative to the dose-area product (DAP) was reduced by 81% and 79% in cerebral procedures and abdominal procedures, respectively. The use of radiation shielding decreased operator exposure up to 97% in phantom experiments; however, operator dose data show that this reduction was not fully achieved in clinical practice. Both phantom experiments and clinical procedures showed that the largest contribution to relative operator dose originated from left-anterior-oblique C-arm angulations (59%-75% of clinical operator exposure). Of the various x-ray acquisition types used, fluoroscopy was the main contributor to procedural DAP (49%) and operator dose in clinical procedures (82%). CONCLUSIONS: Achievable levels for radiation exposure reduction were determined and compared with real-life clinical practice. This generated evidence-based advice on the conditions required for optimal radiation safety.


Subject(s)
Occupational Exposure/prevention & control , Occupational Health , Radiation Dosage , Radiation Exposure/prevention & control , Radiography, Interventional , Fluoroscopy , Humans , Occupational Exposure/adverse effects , Radiation Exposure/adverse effects , Radiation Monitoring , Radiation Protection , Radiography, Interventional/adverse effects , Risk Assessment , Risk Factors , Scattering, Radiation
4.
Cardiovasc Intervent Radiol ; 40(11): 1756-1762, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28500459

ABSTRACT

PURPOSE: Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. MATERIALS AND METHODS: Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1-5th months: Staff did not receive feedback (n = 701) and (2) 6-8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. RESULTS: Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04-0.50) µSv/Gy cm2 versus (phase 2) 0.08 (0.02-0.24) µSv/Gy cm2, p = 0.002]. CONCLUSION: Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.


Subject(s)
Medical Staff, Hospital/statistics & numerical data , Occupational Exposure/statistics & numerical data , Radiation Dosage , Radiation Monitoring/methods , Radiography, Interventional/methods , Female , Fluoroscopy/methods , Humans , Occupational Exposure/prevention & control , Prospective Studies , Radiation Monitoring/statistics & numerical data , Radiation Protection/methods , Radiography, Interventional/statistics & numerical data
5.
Cardiovasc Intervent Radiol ; 40(3): 421-429, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27942927

ABSTRACT

PURPOSE: Knowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses. MATERIALS AND METHODS: All interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to procedure type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28). RESULTS: Median (±IQR) DAP doses ranged from 2.0 (0.8-3.1) (percutaneous gastrostomy) to 84 (53-147) Gy cm2 (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1-5.0) µSv to 33.4 (12.1-125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 µSv/Gy cm2 in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types. CONCLUSION: Real-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.


Subject(s)
Medical Staff, Hospital , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Radiation Dosage , Radiation Monitoring/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation , Computer Systems , Endovascular Procedures/instrumentation , Humans , Prospective Studies , Radiation Protection/instrumentation , Radiology, Interventional/instrumentation , Statistics as Topic
6.
J Immunol ; 196(1): 459-68, 2016 Jan 01.
Article in English | MEDLINE | ID: mdl-26597008

ABSTRACT

Dendritic cell (DC) migration is essential for efficient host defense against pathogens and cancer, as well as for the efficacy of DC-based immunotherapies. However, the molecules that induce the migratory phenotype of DCs are poorly defined. Based on a large-scale proteome analysis of maturing DCs, we identified the GPI-anchored protein semaphorin 7A (Sema7A) as being highly expressed on activated primary myeloid and plasmacytoid DCs in human and mouse. We demonstrate that Sema7A deficiency results in impaired chemokine CCL21-driven DC migration in vivo. Impaired formation of actin-based protrusions, resulting in slower three-dimensional migration, was identified as the mechanism underlying the DC migration defect. Furthermore, we show, by atomic force microscopy, that Sema7A decreases adhesion strength to extracellular matrix while increasing the connectivity of adhesion receptors to the actin cytoskeleton. This study demonstrates that Sema7A controls the assembly of actin-based protrusions that drive DC migration in response to CCL21.


Subject(s)
Actin Cytoskeleton/metabolism , Antigens, CD/physiology , Cell Movement/physiology , Chemokine CCL21/metabolism , Dendritic Cells/physiology , Extracellular Matrix/metabolism , Semaphorins/physiology , Animals , Antigens, CD/genetics , Cell Adhesion , Cell Movement/genetics , Cells, Cultured , GPI-Linked Proteins/genetics , GPI-Linked Proteins/physiology , Humans , Mice , Mice, Knockout , Microscopy, Atomic Force , RNA Interference , RNA, Small Interfering , Semaphorins/genetics
7.
Invest Radiol ; 50(10): 679-85, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26011823

ABSTRACT

OBJECTIVES: Our study aim was to assess the radiation dose of digital breast tomosynthesis (DBT) in comparison to full-field digital mammography (FFDM) in a clinical setting. MATERIALS AND METHODS: Two-hundred four patients were consecutively included, of which 236 complementary DBT and FFDM examinations were available. All acquisitions were performed on a single commercially available mammography system capable of FFDM and DBT acquisitions using an antiscatter grid. The average glandular dose (AGD) was calculated for each examination using the Dance method. For this, tube output and half-value layer were measured, and the required exposure parameters (target/filter material, tube voltage, tube load, compressed breast thickness) were retrieved from the DICOM metadata. The DBT and FFDM AGD values were pairwise tested, and a subanalysis with respect to breast thickness was performed. RESULTS: The mean (SD) AGD values for a single-view DBT and FFDM were 1.49 (0.36) mGy and 1.62 (0.55) mGy, respectively, which are small but statistically significant differences. This difference may be partially attributed to the small difference in the mean breast thickness between FFDM and DBT (3 mm). In this patient population, the AGD was lower for DBT than for FFDM in 61% of the patients. When patients were categorized according to breast thickness, the AGD of DBT was only significantly smaller than the AGD of FFDM for breast thickness categories larger than 50 mm, indicating that the dose reduction for DBT compared with FFDM was more pronounced in thick breasts. CONCLUSIONS: The radiation dose of patients undergoing a single-view DBT was comparable to a single-view FFDM. For patients with thicker breasts, the radiation dose of DBT was slightly lower than FFDM.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography , Radiation Dosage , Radiation Exposure , Radiographic Image Enhancement , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged
8.
Trends Biotechnol ; 32(9): 456-65, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24998519

ABSTRACT

Active anti-cancer immune responses depend on efficient presentation of tumor antigens and co-stimulatory signals by antigen-presenting cells (APCs). Therapy with autologous natural APCs is costly and time-consuming and results in variable outcomes in clinical trials. Therefore, development of artificial APCs (aAPCs) has attracted significant interest as an alternative. We discuss the characteristics of various types of acellular aAPCs, and their clinical potential in cancer immunotherapy. The size, shape, and ligand mobility of aAPCs and their presentation of different immunological signals can all have significant effects on cytotoxic T cell activation. Novel optimized aAPCs, combining carefully tuned properties, may lead to efficient immunomodulation and improved clinical responses in cancer immunotherapy.


Subject(s)
Antigen-Presenting Cells/physiology , Artificial Cells/immunology , Immunotherapy/methods , Neoplasms/therapy , Biomedical Research/trends , Humans , Lymphocyte Activation , T-Lymphocytes, Cytotoxic/immunology
9.
Magn Reson Med ; 72(2): 409-17, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24186703

ABSTRACT

PURPOSE: A high-quality, reproducible, multi-slice T2-mapping protocol for the mouse heart is presented. METHODS: A T2-prepared sequence with composite 90° and 180° radiofrequency pulses in a segmented MLEV phase cycling scheme was developed. The T2-mapping protocol was optimized using simulations and evaluated with phantoms. RESULTS: Repeatability for determination of myocardial T2 values was assessed in vivo in n = 5 healthy mice on 2 different days. The average baseline T2 of the left ventricular myocardium was 22.5 ± 1.7 ms. The repeatability coefficient for R2 = 1/T2 for measurements at different days was ΔR2 = 6.3 s(−1). Subsequently, T2 mapping was applied in comparison to late-gadolinium-enhancement (LGE) imaging, to assess 1-day-old ischemia/reperfusion (IR) myocardial injury in n = 8 mice. T2 in the infarcts was significantly higher than in remote tissue, whereas remote tissue was not significantly different from baseline. Infarct sizes based on T2 versus LGE showed strong correlation. To assess the time-course of T2 changes in the infarcts, T2 mapping was performed at day 1, 3, and 7 after IR injury in a separate group of mice (n = 16). T2 was highest at day 3, in agreement with the expected time course of edema formation and resolution after myocardial infarction. CONCLUSION: T2 prepared imaging provides high quality reproducible T2 maps of healthy and diseased mouse myocardium.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Myocardial Infarction/pathology , Myocardium/pathology , Animals , Mice , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
10.
PLoS One ; 8(4): e61510, 2013.
Article in English | MEDLINE | ID: mdl-23585908

ABSTRACT

AIMS: Controversy exists in regard to the beneficial effects of transplanting cardiac or somatic progenitor cells upon myocardial injury. We have therefore investigated the functional short- and long-term consequences after intramyocardial transplantation of these cell types in a murine lesion model. METHODS AND RESULTS: Myocardial infarction (MI) was induced in mice (n = 75), followed by the intramyocardial injection of 1-2×10(5) luciferase- and GFP-expressing embryonic cardiomyocytes (eCMs), skeletal myoblasts (SMs), mesenchymal stem cells (MSCs) or medium into the infarct. Non-treated healthy mice (n = 6) served as controls. Bioluminescence and fluorescence imaging confirmed the engraftment and survival of the cells up to seven weeks postoperatively. After two weeks MRI was performed, which showed that infarct volume was significantly decreased by eCMs only (14.8±2.2% MI+eCM vs. 26.7±1.6% MI). Left ventricular dilation was significantly decreased by transplantation of any cell type, but most efficiently by eCMs. Moreover, eCM treatment increased the ejection fraction and cardiac output significantly to 33.4±2.2% and 22.3±1.2 ml/min. In addition, this cell type exclusively and significantly increased the end-systolic wall thickness in the infarct center and borders and raised the wall thickening in the infarct borders. Repetitive echocardiography examinations at later time points confirmed that these beneficial effects were accompanied by better survival rates. CONCLUSION: Cellular cardiomyoplasty employing contractile and electrically coupling embryonic cardiomyocytes (eCMs) into ischemic myocardium provoked significantly smaller infarcts with less adverse remodeling and improved cardiac function and long-term survival compared to transplantation of somatic cells (SMs and MSCs), thereby proving that a cardiomyocyte phenotype is important to restore myocardial function.


Subject(s)
Cardiomyoplasty/methods , Myocardial Infarction/therapy , Myocytes, Cardiac/transplantation , Recovery of Function , Animals , Cardiac Output/physiology , Embryo, Mammalian , Genes, Reporter , Injections, Intramuscular , Luciferases , Male , Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/physiology , Mice , Mice, Inbred C57BL , Myoblasts/cytology , Myoblasts/physiology , Myoblasts/transplantation , Myocardial Infarction/mortality , Myocardial Infarction/pathology , Myocardial Infarction/physiopathology , Myocardium/pathology , Myocytes, Cardiac/cytology , Myocytes, Cardiac/physiology , Stroke Volume/physiology , Survival Analysis , Transplantation, Autologous , Ventricular Function, Left
11.
Curr Opin Immunol ; 25(3): 389-95, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23571027

ABSTRACT

Cancer immunotherapy critically relies on the efficient presentation of tumor antigens to T-cells to elicit a potent anti-tumor immune response aimed at life-long protection against cancer recurrence. Recent advances in the nanovaccine field have now resulted in formulations that trigger strong anti-tumor responses. Nanovaccines are assemblies that are able to present tumor antigens and appropriate immune-stimulatory signals either directly to T-cells or indirectly via antigen-presenting dendritic cells. This review focuses on important aspects of nanovaccine design for dendritic cells, including the synergistic and cytosolic delivery of immunogenic compounds, as well as their passive and active targeting to dendritic cells. In addition, nanoparticles for direct T-cell activation are discussed, addressing features necessary to effectively mimic dendritic cell/T-cell interactions.


Subject(s)
Cancer Vaccines/immunology , Dendritic Cells/immunology , Immunotherapy , Neoplasms/therapy , Animals , Antigens, Neoplasm/immunology , Humans , Nanotechnology , Neoplasms/immunology
12.
Mol Imaging Biol ; 15(4): 411-22, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23400400

ABSTRACT

PURPOSE: Magnetic resonance imaging (MRI) with targeted contrast agents provides a promising means for diagnosis and treatment monitoring after cerebrovascular injury. Our goal was to demonstrate the feasibility of this approach to detect the neuroinflammatory biomarker intercellular adhesion molecule-1 (ICAM-1) after stroke and to establish a most efficient imaging procedure. PROCEDURES: We compared two types of ICAM-1-functionalized contrast agent: T 1-shortening gadolinium chelate-containing liposomes and T2(*)-shortening micron-sized iron oxide particles (MPIO). Binding efficacy and MRI contrast effects were tested in cell cultures and a mouse stroke model. RESULTS: Both ICAM-1-targeted agents bound effectively to activated cerebrovascular cells in vitro, generating significant MRI contrast-enhancing effects. Direct in vivo MRI-based detection after stroke was only achieved with ICAM-1-targeted MPIO, although both contrast agents showed similar target-specific vascular accumulation. CONCLUSIONS: Our study demonstrates the potential of in vivo MRI of post-stroke ICAM-1 upregulation and signifies target-specific MPIO as most suitable contrast agent for molecular MRI of cerebrovascular inflammation.


Subject(s)
Contrast Media , Intercellular Adhesion Molecule-1/genetics , Magnetic Resonance Imaging , Particulate Matter , Stroke/diagnosis , Up-Regulation/genetics , Animals , Brain/blood supply , Brain/pathology , Cell Line , Endothelial Cells/metabolism , Ferric Compounds , Gadolinium , Inflammation/pathology , Intercellular Adhesion Molecule-1/metabolism , Liposomes , Mice , Mice, Inbred C57BL , Particle Size , Postmortem Changes , RNA, Messenger/genetics , RNA, Messenger/metabolism , Stroke/genetics , Stroke/pathology
13.
Contrast Media Mol Imaging ; 8(2): 117-26, 2013.
Article in English | MEDLINE | ID: mdl-23281284

ABSTRACT

Reperfusion therapy is commonly applied after a myocardial infarction. Reperfusion, however, causes secondary damage. An emerging approach for treatment of ischemia-reperfusion (IR) injury involves the delivery of therapeutic nanoparticles to the myocardium to promote cell survival and constructively influence scar formation and myocardial remodeling. The aim of this study was to provide detailed understanding of the in vivo accumulation and distribution kinetics of lipid-based nanoparticles (micelles and liposomes) in a mouse model of acute and chronic IR injury. Both micelles and liposomes contained paramagnetic and fluorescent lipids and could therefore be visualized with magnetic resonance imaging (MRI) and confocal laser scanning microscopy (CLSM). In acute IR injury both types of nanoparticles accumulated massively and specifically in the infarcted myocardium as revealed by MRI and CLSM. Micelles displayed faster accumulation kinetics, probably owing to their smaller size. Liposomes occasionally co-localized with vessels and inflammatory cells. In chronic IR injury only minor accumulation of micelles was observed with MRI. Nevertheless, CLSM revealed specific accumulation of both micelles and liposomes in the infarct area 3 h after administration. Owing to their specific accumulation in the infarcted myocardium, lipid-based micelles and liposomes are promising vehicles for (visualization of) drug delivery in myocardial infarction.


Subject(s)
Gadolinium DTPA , Lipids/pharmacokinetics , Nanoparticles , Reperfusion Injury/metabolism , Reperfusion Injury/pathology , Animals , Gadolinium DTPA/pharmacokinetics , Liposomes/pharmacokinetics , Mice , Tissue Distribution
14.
J Nanobiotechnology ; 10: 37, 2012 Aug 28.
Article in English | MEDLINE | ID: mdl-22929153

ABSTRACT

BACKGROUND: Inflammation plays an important role in many pathologies, including cardiovascular diseases, neurological conditions and oncology, and is considered an important predictor for disease progression and outcome. In vivo imaging of inflammatory cells will improve diagnosis and provide a read-out for therapy efficacy. Paramagnetic phosphatidylserine (PS)-containing liposomes were developed for magnetic resonance imaging (MRI) and confocal microscopy imaging of macrophages. These nanoparticles also provide a platform to combine imaging with targeted drug delivery. RESULTS: Incorporation of PS into liposomes did not affect liposomal size and morphology up to 12 mol% of PS. Liposomes containing 6 mol% of PS showed the highest uptake by murine macrophages, while only minor uptake was observed in endothelial cells. Uptake of liposomes containing 6 mol% of PS was dependent on the presence of Ca2+ and Mg2+. Furthermore, these 6 mol% PS-containing liposomes were mainly internalized into macrophages, whereas liposomes without PS only bound to the macrophage cell membrane. CONCLUSIONS: Paramagnetic liposomes containing 6 mol% of PS for MR imaging of macrophages have been developed. In vitro these liposomes showed specific internalization by macrophages. Therefore, these liposomes might be suitable for in vivo visualization of macrophage content and for (visualization of) targeted drug delivery to inflammatory cells.


Subject(s)
Liposomes/pharmacokinetics , Macrophages/metabolism , Phosphatidylserines/pharmacokinetics , Animals , Cations/chemistry , Cell Line , Cell Membrane/metabolism , Liposomes/chemistry , Macrophages/chemistry , Macrophages/cytology , Magnetic Resonance Imaging , Mice , Microscopy, Confocal , Phagocytosis , Phosphatidylserines/chemistry
15.
J Control Release ; 162(2): 276-85, 2012 Sep 10.
Article in English | MEDLINE | ID: mdl-22771978

ABSTRACT

Adverse cardiac remodeling after myocardial infarction ultimately causes heart failure. To stimulate reparative processes in the infarct, efficient delivery and retention of therapeutic agents is desired. This might be achieved by encapsulation of drugs in nanoparticles. The goal of this study was to characterize the distribution pattern of differently sized long-circulating lipid-based nanoparticles, namely micelles (~15 nm) and liposomes (~100 nm), in a mouse model of myocardial infarction (MI). MI was induced in mice (n=38) by permanent occlusion of the left coronary artery. Nanoparticle accumulation following intravenous administration was examined one day and one week after surgery, representing the acute and chronic phase of MI, respectively. In vivo magnetic resonance imaging of paramagnetic lipids in the micelles and liposomes was employed to monitor the trafficking of nanoparticles to the infarcted myocardium. Ex vivo high-resolution fluorescence microscopy of fluorescent lipids was used to determine the exact location of the nanoparticles in the myocardium. In both acute and chronic MI, micelles permeated the entire infarct area, which renders them very suited for the local delivery of cardioprotective or anti-remodeling drugs. Liposomes displayed slower and more restricted extravasation from the vasculature and are therefore an attractive vehicle for the delivery of pro-angiogenic drugs. Importantly, the ability to non-invasively visualize both micelles and liposomes with MRI creates a versatile approach for the development of effective cardioprotective therapeutic interventions.


Subject(s)
Contrast Media/pharmacokinetics , Gadolinium DTPA/pharmacokinetics , Myocardial Infarction/metabolism , Nanoparticles , Animals , Contrast Media/administration & dosage , Drug Monitoring , Gadolinium DTPA/administration & dosage , Lipids/administration & dosage , Lipids/pharmacokinetics , Liposomes , Magnetic Resonance Imaging , Mice , Micelles , Myocardium/metabolism , Nanoparticles/administration & dosage
16.
J Nanobiotechnology ; 10: 25, 2012 Jun 20.
Article in English | MEDLINE | ID: mdl-22716048

ABSTRACT

BACKGROUND: The upregulation of intercellular adhesion molecule-1 (ICAM-1) on the endothelium of blood vessels in response to pro-inflammatory stimuli is of major importance for the regulation of local inflammation in cardiovascular diseases such as atherosclerosis, myocardial infarction and stroke. In vivo molecular imaging of ICAM-1 will improve diagnosis and follow-up of patients by non-invasive monitoring of the progression of inflammation. RESULTS: A paramagnetic liposomal contrast agent functionalized with anti-ICAM-1 antibodies for multimodal magnetic resonance imaging (MRI) and fluorescence imaging of endothelial ICAM-1 expression is presented. The ICAM-1-targeted liposomes were extensively characterized in terms of size, morphology, relaxivity and the ability for binding to ICAM-1-expressing endothelial cells in vitro. ICAM-1-targeted liposomes exhibited strong binding to endothelial cells that depended on both the ICAM-1 expression level and the concentration of liposomes. The liposomes had a high longitudinal and transversal relaxivity, which enabled differentiation between basal and upregulated levels of ICAM-1 expression by MRI. The liposome affinity for ICAM-1 was preserved in the competing presence of leukocytes and under physiological flow conditions. CONCLUSION: This liposomal contrast agent displays great potential for in vivo MRI of inflammation-related ICAM-1 expression.


Subject(s)
Contrast Media/chemistry , Endothelial Cells/metabolism , Intercellular Adhesion Molecule-1/chemistry , Liposomes/chemistry , Magnetic Resonance Imaging/methods , Animals , Cell Line , Drug Delivery Systems , Gadolinium/chemistry , Immunoglobulin G/chemistry , Immunoglobulin G/metabolism , Intercellular Adhesion Molecule-1/metabolism , Leukocytes/metabolism , Liposomes/metabolism , Mice , Molecular Imaging , Shear Strength , Stress, Mechanical , Tumor Necrosis Factor-alpha/metabolism
17.
NMR Biomed ; 25(8): 953-68, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22308108

ABSTRACT

The use of contrast agents has added considerable value to the existing cardiac MRI toolbox that can be used to study murine myocardial infarction, as it enables detailed in vivo visualization of the molecular and cellular processes that occur in the infarcted and remote tissue. A variety of non-targeted and targeted contrast agents to study myocardial infarction are available and under development. Manganese, which acts as a calcium analogue, can be used to assess cell viability. Traditionally, low-molecular-weight Gd-containing contrast agents are employed to measure infarct size in a late gadolinium enhancement experiment. Gd-based blood-pool agents are used to study the vascular status of the myocardium. The use of targeted contrast agents facilitates more detailed imaging of pathophysiological processes in the acute and chronic infarct. Cell death was visualized by contrast agents functionalized with annexin A5 that binds specifically to phosphatidylserine accessible on dying cells and with an agent that binds to the exposed DNA of dead cells. Inflammation in the myocardium was depicted by contrast agents that target cell adhesion molecules expressed on activated endothelium, by contrast agents that are phagocytosed by inflammatory cells, and by using a probe that targets enzymes excreted by inflammatory cells. Cardiac remodeling processes were visualized with a contrast agent that binds to angiogenic vasculature and with an MR probe that specifically binds to collagen in the fibrotic myocardium. These recent advances in murine contrast-enhanced cardiac MRI have made a substantial contribution to the visualization of the pathophysiology of myocardial infarction, cardiac remodeling processes and the progression to heart failure, which helps to design new treatments. This review discusses the advances and challenges in the development and application of MRI contrast agents to study murine myocardial infarction.


Subject(s)
Contrast Media , Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnosis , Animals , Gadolinium , Manganese , Mice , Myocardial Infarction/pathology , Myocardium/pathology
18.
NMR Biomed ; 25(8): 969-84, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22311260

ABSTRACT

Mouse models are increasingly used to study the pathophysiology of myocardial infarction in vivo. In this area, MRI has become the gold standard imaging modality, because it combines high spatial and temporal resolution functional imaging with a large variety of methods to generate soft tissue contrast. In addition, (target-specific) MRI contrast agents can be employed to visualize different processes in the cascade of events following myocardial infarction. Here, the MRI sequence has a decisive role in the detection sensitivity of a contrast agent. However, a straightforward translation of clinically available protocols for human cardiac imaging to mice is not feasible, because of the small size of the mouse heart and its extremely high heart rate. This has stimulated intense research in the development of cardiac MRI protocols specifically tuned to the mouse with regard to timing parameters, acquisition strategies, and ECG- and respiratory-triggering methods to find an optimal trade-off between sensitivity, scan time, and image quality. In this review, a detailed analysis is given of the pros and cons of different mouse cardiac MR imaging methodologies and their application in contrast-enhanced MRI of myocardial infarction.


Subject(s)
Contrast Media , Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnosis , Animals , Humans , Imaging, Three-Dimensional , Mice , Myocardium/pathology , Perfusion
19.
J Cardiovasc Magn Reson ; 13: 56, 2011 Oct 05.
Article in English | MEDLINE | ID: mdl-21974927

ABSTRACT

BACKGROUND: Quantitative relaxation time measurements by cardiovascular magnetic resonance (CMR) are of paramount importance in contrast-enhanced studies of experimental myocardial infarction. First, compared to qualitative measurements based on signal intensity changes, they are less sensitive to specific parameter choices, thereby allowing for better comparison between different studies or during longitudinal studies. Secondly, T1 measurements may allow for quantification of local contrast agent concentrations. In this study, a recently developed 3D T1 mapping technique was applied in a mouse model of myocardial infarction to measure differences in myocardial T1 before and after injection of a liposomal contrast agent. This was then used to assess the concentration of accumulated contrast agent. MATERIALS AND METHODS: Myocardial ischemia/reperfusion injury was induced in 8 mice by transient ligation of the LAD coronary artery. Baseline quantitative T1 maps were made at day 1 after surgery, followed by injection of a Gd-based liposomal contrast agent. Five mice served as control group, which followed the same protocol without initial surgery. Twenty-four hours post-injection, a second T1 measurement was performed. Local ΔR1 values were compared with regional wall thickening determined by functional cine CMR and correlated to ex vivo Gd concentrations determined by ICP-MS. RESULTS: Compared to control values, pre-contrast T1 of infarcted myocardium was slightly elevated, whereas T1 of remote myocardium did not significantly differ. Twenty-four hours post-contrast injection, high ΔR1 values were found in regions with low wall thickening values. However, compared to remote tissue (wall thickening > 45%), ΔR1 was only significantly higher in severe infarcted tissue (wall thickening < 15%). A substantial correlation (r = 0.81) was found between CMR-based ΔR1 values and Gd concentrations from ex vivo ICP-MS measurements. Furthermore, regression analysis revealed that the effective relaxivity of the liposomal contrast agent was only about half the value determined in vitro. CONCLUSIONS: 3D cardiac T1 mapping by CMR can be used to monitor the accumulation of contrast agents in contrast-enhanced studies of murine myocardial infarction. The contrast agent relaxivity was decreased under in vivo conditions compared to in vitro measurements, which needs consideration when quantifying local contrast agent concentrations.


Subject(s)
Albumins , Contrast Media , Gadolinium DTPA , Imaging, Three-Dimensional , Magnetic Resonance Imaging, Cine , Myocardial Infarction/diagnosis , Myocardial Reperfusion Injury/diagnosis , Myocardium/pathology , Albumins/pharmacokinetics , Animals , Contrast Media/pharmacokinetics , Disease Models, Animal , Gadolinium DTPA/pharmacokinetics , Liposomes , Male , Mice , Myocardial Infarction/metabolism , Myocardial Infarction/pathology , Myocardial Reperfusion Injury/metabolism , Myocardial Reperfusion Injury/pathology , Myocardium/metabolism , Predictive Value of Tests , Tissue Distribution
20.
Contrast Media Mol Imaging ; 6(1): 35-45, 2011.
Article in English | MEDLINE | ID: mdl-20882509

ABSTRACT

Interest in the use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of three differently sized gadolinium-based contrast agents to permeate different mouse plaque phenotypes was evaluated with MRI. A tapered cast was implanted around the right carotid artery of apoE(-/-) mice to induce two different plaque phenotypes: a thin cap fibroatheroma (TCFA) and a non-TCFA lesion. Both plaques were allowed to develop over 6 and 9 weeks, leading to an intermediate and advanced lesion, respectively. Signal enhancement in the carotid artery wall, following intravenous injection of Gd-HP-DO3A as well as paramagnetic micelles and liposomes was evaluated. In vivo T(1) -weighted MRI plaque enhancement characteristics were complemented by fluorescence microscopy and correlated to lesion phenotype. The two smallest contrast agents, i.e. Gd-HP-DO3A and micelles, were found to enhance contrast in T(1) -weighted MR images of all investigated plaque phenotypes. Maximum contrast enhancement ranged between 53 and 70% at 6 min after injection of Gd-HP-DO3A with highest enhancement and longest retention in the non-TCFA lesion. Twenty-four hours after injection of micelles maximum contrast enhancement ranged between 24 and 35% in all plaque phenotypes. Administration of the larger liposomes did not cause significant contrast enhancement in the atherosclerotic plaques. Confocal fluorescence microscopy confirmed the MRI-based differences in plaque permeation between micelles and liposomes. Plaque permeation of contrast agents was strongly dependent on size. Our results implicate that, when equipped with targeting ligands, liposomes are most suitable for the imaging of plaque-associated endothelial markers due to low background enhancement, whereas micelles, which accumulate extravascularly on a long timescale, are suited for imaging of less abundant markers inside plaques. Low molecular weight compounds may be employed for target-specific imaging of highly abundant extravascular plaque-associated targets.


Subject(s)
Contrast Media , Magnetic Resonance Imaging/methods , Plaque, Atherosclerotic/diagnostic imaging , Animals , Apolipoproteins E/genetics , Contrast Media/chemistry , Contrast Media/pharmacokinetics , Electron Spin Resonance Spectroscopy/methods , Female , Half-Life , Image Enhancement/methods , Liposomes/pharmacokinetics , Mice , Mice, Knockout , Phenotype , Plaque, Atherosclerotic/genetics , Plaque, Atherosclerotic/metabolism , Plaque, Atherosclerotic/pathology , Radiography , Tissue Distribution