Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Vet Dent ; 39(2): 112-121, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35306919

ABSTRACT

To evaluate healing and complications of extraction sites closed with a simple interrupted pattern (SI) and a simple continuous (SC) suture pattern in a prospective randomized clinical trial. Greyhounds were selected from a rescue with a standardized environment and naturally occurring disease. Surgical extractions were performed (35 sites) and all mucogingival flaps were closed with 4-0 poliglecaprone 25 using either SI or SC randomly assigned by surgical site. Oral healing/dehiscence, suture inflammation, suture loss, accumulation of debris, presence/nature of discharge, necrotic tissue and adjacent contact ulceration were evaluated. Fisher's exact test was used to compare categorical data and two-tail T tests used to compare continuous data. Results showed SC was faster to apply. No new dehiscence events were detected after Recheck 1. There was no significant difference for dehiscence scores between SI and SC. A trend was seen towards more major dehiscence in the SI group. This study concluded SC is an alternative to SI for closure of occlusal surfaces in the mouth. Mandibular canine tooth extraction sites were more likely to have a high dehiscence score than all other sites combined regardless of surgical technique.


Subject(s)
Suture Techniques , Sutures , Animals , Dioxanes , Dogs , Polyesters , Prospective Studies , Suture Techniques/veterinary , Sutures/veterinary
2.
J Vet Dent ; 38(1): 8-17, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33998345

ABSTRACT

The purpose of the study was to determine the effect of suture pattern and repair length on the load to failure in an ex vivo canine gingival model. Healthy mandibular gingiva and mucosa were harvested from fresh cadavers euthanized for purposes unrelated to the study. Samples were randomly assigned by length and pattern. Lingual and buccal free gingival margins were apposed using a simple interrupted (SI), cruciate (XT), simple continuous (SC), or unidirectional knotless continuous barbed suture (SF) closure technique with USP 4-0 poliglecaprone 25i, ii applied over 2 lengths (3 cm and 6 cm). A custom template was used to ensure uniform suture bite application. Surgical time was recorded. Using a soft tissue mechanical testing frame, samples were tensioned to failure. Testing was video recorded and reviewed in conjunction with the tension trace data for tension at initial failure (Tfail) and maximum tension sustained (Tmax). Two factor ANOVA by length and pattern was performed followed by individual one way T-tests. Statistically significant findings were XT-SC-SF patterns were quicker to perform than SI. SF was more likely to fail by suture breakage than tissue tearing, and SF withstood less tension at the 3 cm length than SI-XT-SC. No significant difference was detected in Tmax or Tfail between SI and SC or XT. The study demonstrates that SC and XT are comparable to SI in tension resistance and faster to perform suggesting that SC and XT could replace SI for extraction site closure although further in vivo testing is required.


Subject(s)
Dog Diseases , Suture Techniques , Animals , Biomechanical Phenomena , Cadaver , Dioxanes , Dogs , Gingiva/surgery , Polyesters , Suture Techniques/veterinary , Sutures
3.
J Vet Dent ; 36(3): 202-208, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31928396

ABSTRACT

The goal of this article is to provide an overview at a mechanical level of how the dental machine functions. A description of the low-speed handpiece and its air-driven micromotor as well as the high-speed handpiece and turbine will be provided. The compressor, rheostat, air-water syringe, suction, fiber-optic light, and handpiece couplings will also be discussed. It is important to understand the function of equipment to allow for troubleshooting problems and understanding maintenance requirements to keep equipment functioning optimally.


Subject(s)
Dental High-Speed Equipment/veterinary , Animals
SELECTION OF CITATIONS
SEARCH DETAIL
...