Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38804218

ABSTRACT

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Electrocardiography, Ambulatory , Primary Prevention , Humans , Primary Prevention/methods , Male , Female , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Middle Aged , Aged , Prospective Studies , Electrocardiography, Ambulatory/methods , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Assessment/methods , Risk Factors , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Arrhythmias, Cardiac/mortality , Treatment Outcome , Predictive Value of Tests , Time Factors , Europe/epidemiology , Prognosis , Heart Rate/physiology
2.
Europace ; 24(5): 774-783, 2022 05 03.
Article in English | MEDLINE | ID: mdl-34849744

ABSTRACT

AIM: The association of standard 12-lead electrocardiogram (ECG) markers with benefits of the primary prophylactic implantable cardioverter-defibrillator (ICD) has not been determined in the contemporary era. We analysed traditional and novel ECG variables in a large prospective, controlled primary prophylactic ICD population to assess the predictive value of ECG in terms of ICD benefit. METHODS AND RESULTS: Electrocardiograms from 1477 ICD patients and 700 control patients (EU-CERT-ICD; non-randomized, controlled, prospective multicentre study; ClinicalTrials.gov Identifier: NCT02064192), who met ICD implantation criteria but did not receive the device, were analysed. The primary outcome was all-cause mortality. In ICD patients, the co-primary outcome of first appropriate shock was used. Mean follow-up time was 2.4 ± 1.1 years to death and 2.3 ± 1.2 years to the first appropriate shock. Pathological Q waves were associated with decreased mortality in ICD patients [hazard ratio (HR) 0.54, 95% confidence interval (CI) 0.35-0.84; P < 0.01] and patients with pathological Q waves had significantly more benefit from ICD (HR 0.44, 95% CI 0.21-0.93; P = 0.03). QTc interval increase taken as a continuous variable was associated with both mortality and appropriate shock incidence, but commonly used cut-off values, were not statistically significantly associated with either of the outcomes. CONCLUSION: Pathological Q waves were a strong ECG predictor of ICD benefit in primary prophylactic ICD patients. Excess mortality among Q wave patients seems to be due to arrhythmic death which can be prevented by ICD.


Subject(s)
Defibrillators, Implantable , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Electrocardiography , Humans , Primary Prevention/methods , Prospective Studies , Risk Factors
3.
Int J Cardiol ; 309: 78-83, 2020 06 15.
Article in English | MEDLINE | ID: mdl-32188583

ABSTRACT

BACKGROUND: Abnormal 12-lead electrocardiogram (ECG) can predict cardiovascular events, including sudden cardiac death. We tested the hypothesis that ECG provides useful information on guiding implantable cardioverter defibrillator (ICD) therapy into individuals with impaired left ventricular ejection fraction (LVEF). METHODS: Retrospective data of primary prevention ICD implantations from 14 European centers were gathered. The registry included 5111 subjects of whom 1687 patients had an interpretable pre-implantation ECG available (80.0% male, 63.3 ± 11.4 years). Primary outcome was survival without appropriate ICD shocks or heart transplantation. A low-risk ECG was defined as a combination of ECG variables that were associated with the primary outcome. RESULTS: A total of 1224 (72.6%) patients survived the follow-up (2.9 ± 1.7 years) without an ICD shock, 224 (13.3%) received an appropriate shock and 260 (15.4%) died. Low-risk ECG defined as QRS duration <120 ms, QTc interval <450 ms for men and <470 ms for women, and sinus rhythm, were met by 515 patients (30.5%). Multivariable Cox regression showed that the hazard (HR) for death, heart transplantation or appropriate shock were reduced by 42.5% in the low-risk group (HR 0.575; 95% CI 0.45-0.74; p < 0.001), compared to the high-risk group. The HR for the first appropriate shock was 42.1% lower (HR 0.58; 95% CI 0.41-0.82; p = 0.002) and the HR for death was 48.0% lower (HR 0.52; 95% CI 0.386-0.72; p < 0.001) in the low-risk group. CONCLUSION: Sinus rhythm, QRS <120 ms and normal QTc in standard 12-lead ECG provides information about survival without appropriate ICD shocks and might improve patient selection for primary prevention ICD therapy.


Subject(s)
Defibrillators, Implantable , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Electrocardiography , Female , Humans , Male , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome , Ventricular Function, Left
4.
Diabetes Care ; 43(1): 196-200, 2020 01.
Article in English | MEDLINE | ID: mdl-31645407

ABSTRACT

OBJECTIVE: Diabetes increases the risk of all-cause mortality and sudden cardiac death (SCD). The exact mechanisms leading to sudden death in diabetes are not well known. We compared the incidence of appropriate shocks and mortality in patients with versus without diabetes with a prophylactic implantable cardioverter defibrillator (ICD) included in the retrospective EU-CERT-ICD registry. RESEARCH DESIGN AND METHODS AND RESULTS: A total of 3,535 patients from 12 European EU-CERT-ICD centers with a mean age of 63.7 ± 11.2 years (82% males) at the time of ICD implantation were included in the analysis. A total of 995 patients (28%) had a history of diabetes. All patients had an ICD implanted for primary SCD prevention. End points were appropriate shock and all-cause mortality. Mean follow-up time was 3.2 ± 2.3 years. Diabetes was associated with a lower risk of appropriate shocks (adjusted hazard ratio [HR] 0.77 [95% CI 0.62-0.96], P = 0.02). However, patients with diabetes had significantly higher mortality (adjusted HR 1.30 [95% CI 1.11-1.53], P = 0.001). CONCLUSIONS: All-cause mortality is higher in patients with diabetes than in patients without diabetes with primary prophylactic ICDs. Subsequently, patients with diabetes have a lower incidence of appropriate ICD shocks, indicating that the excess mortality might not be caused primarily by ventricular tachyarrhythmias. These findings suggest a limitation of the potential of prophylactic ICD therapy to improve survival in patients with diabetes with impaired left ventricular function.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Diabetes Mellitus/mortality , Electroshock/statistics & numerical data , Tachycardia/mortality , Tachycardia/therapy , Aged , Defibrillators, Implantable/statistics & numerical data , Diabetes Mellitus/physiopathology , Diabetes Mellitus/therapy , Diabetic Angiopathies/mortality , Diabetic Angiopathies/physiopathology , Diabetic Angiopathies/therapy , Electroshock/adverse effects , Electroshock/mortality , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Primary Prevention/instrumentation , Primary Prevention/methods , Registries , Retrospective Studies , Tachycardia/complications , Tachycardia/physiopathology , Ventricular Function, Left/physiology
5.
Histopathology ; 69(5): 831-838, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27257976

ABSTRACT

AIMS: Gremlin1 is a bone morphogenetic protein (BMP) antagonist with a suggested role in colorectal cancer (CRC) progression. We have analysed Gremlin1 protein expression in CRC and assessed its correlation with clinicopathological characteristics, including developmental pathway and prognosis. METHODS AND RESULTS: Material included a non-selected series of 148 surgically treated CRC cases. The tumour-node-metastasis (TNM) stage, histological grade and inflammatory infiltrate at the invasive margin were assessed, and tumours were classified to serrated or non-serrated types. Immunohistochemistry was conducted to evaluate Gremlin1 expression. Prognosis (60-month follow-up) was analysed by Kaplan-Meier methods and Cox regression analysis. Gremlin1 expression was detected in epithelial cells both in normal mucosa and in carcinomas. Abundant expression in carcinomas associated with low TNM stage (P = 0.044), low histological grade (P = 0.044), serrated histology (P = 0.033 or P = 0.053 depending on the classification cut-off) and intensive inflammatory infiltrate at the invasive margin (P = 0.044), and was a stage independent indicator of extended survival (P = 0.029). CONCLUSIONS: Gremlin1 protein expression in CRC associates with low tumour stage and extended survival independently of tumour stage, suggesting that it represents a relevant prognostic indicator in CRC. High expression in carcinomas with serrated histology suggests a potential role for Gremlin1 in the serrated pathway of CRC.


Subject(s)
Biomarkers, Tumor/analysis , Colorectal Neoplasms/pathology , Intercellular Signaling Peptides and Proteins/biosynthesis , Adult , Aged , Area Under Curve , Colorectal Neoplasms/metabolism , Colorectal Neoplasms/mortality , Disease Progression , Female , Humans , Immunohistochemistry , Kaplan-Meier Estimate , Male , Middle Aged , Prognosis , Proportional Hazards Models , ROC Curve , Tissue Array Analysis
SELECTION OF CITATIONS
SEARCH DETAIL