Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Org Lett ; 25(44): 8027-8032, 2023 Nov 10.
Article in English | MEDLINE | ID: mdl-37916762

ABSTRACT

An organocatalytic asymmetric [3 + 2] cycloaddition of ß-trifluoromethyl enones with 3-(N-2,2,2-trifluoroethyl) benzothiophene ketimines and 2-(N-2,2,2-trifluoroethyl) benzothiophene ketimines was described for the first time. A wide spectrum of vicinally bis(trifluoromethyl)-substituted spiro pyrrolidine-benzothiophenones were obtained with excellent stereocontrol (all cases >20:1 dr and up to 99% ee). The highlight of this work is the extremely high efficiency in the construction of spirocyclic benzothiophenone derivatives possessing a vicinally bis(trifluoromethyl)-substituted pyrrolidine moiety with four contiguous stereocenters.

2.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 35(10): 1099-1100, 2023 Oct.
Article in Chinese | MEDLINE | ID: mdl-37873717

ABSTRACT

Deep venipuncture catheterization is a routine and basic operation in the treatment of critically ill patients, and it is the most effective way to quickly correct the shock. Clinical B-ultrasound guided deep vein catheters can improve the success rate of puncture, but in the process of operation, the short axis needs to be replaced by the long axis. In the replacement process, the stability of the novice is insufficient, the positioning is difficult, and the operation time is too long. If only short axis puncture is used, it is impossible to know whether the current position of the puncture needle, and the puncture may be too deep and stray into the artery. The accuracy of the 45 degree angle of the injection point requires a very experienced operator. In view of the above shortcomings, doctors in the department of critical care medicine of Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a B-ultrasound puncture equipment, which has obtained the National Invention Patent of China (ZL 2016 1 0571557.X). The device is composed of B-ultrasound probe fixing frame, sliding scale plate, simulation slide rule, puncture needle, sliding device. By sliding device the angle of the pinhole channel, it is conducive to the accurate positioning of the puncture target, optimizing the operation procedure, improving the puncture speed and accuracy, effectively reducing the occurrence of puncture complications, ensuring patient safety, reducing unnecessary waste of human and material resources. It can reduce the workload of medical staff and is worthy of clinical practice.


Subject(s)
Catheterization, Central Venous , Humans , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Ultrasonography, Interventional/methods , Ultrasonography , Punctures/methods , Needles
3.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 35(7): 757-758, 2023 Jul.
Article in Chinese | MEDLINE | ID: mdl-37545456

ABSTRACT

Patients in the intensive care unit (ICU) often need to have various catheters placed on their bodies due to their severe condition. In order to prevent the occurrence of unplanned extubation, patients' hands should be restrained appropriately. The current restraint gloves used in clinical practice have problems such as improper restraint, easy falling off of oxygen saturation monitoring probes, and pressure injury of hands. Therefore, department of critical care medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a wrist restraint glove suitable for restless patients, and obtained the national utility model patent (ZL 2020 2 1612453.7). The device is composed of restraint gloves and restraint rings, which can not only restrain patients, but also continuously monitor the changes of blood oxygen saturation in patients with restfulness. This device is convenient to use, low cost, comfortable to wear, and can prevent the occurrence of device-related pressure injuries, which is suitable for clinical application.


Subject(s)
Intensive Care Units , Wrist , Humans , Critical Care , Hand , Upper Extremity , Restraint, Physical
4.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 34(8): 871-872, 2022 Aug.
Article in Chinese | MEDLINE | ID: mdl-36177933

ABSTRACT

Ventilator-associated pneumonia (VAP) is one of the most common infectious diseases in patients undergoing mechanical ventilation in intensive care unit (ICU). Although the use of closed sputum suction tube for sputum suction is the most common nursing measure for patients with tracheal intubation in ICU, and it is also an important measure to reduce the occurrence of VAP, the existing clinical technology still needs to use external flushing solution for humidification and flushing. In the process of use, the flushing operation has the risk that the amount of flushing fluid cannot be controlled, resulting in a large amount of flushing fluid entering the patient's airway, causing the patient to suffocate. The sputum attached to the wall of the sputum suction tube cannot be completely flushed, and the prolonged retention of the sputum leads to the proliferation of colonized bacteria, aggravating the infection of patients. Repeated pipe flushing not only increases consumables, but also increases the workload of medical staff. For this reason, the author has designed a fully enclosed sputum suction tube flushing device, which has obtained the National Utility Model Patent of China (patent number: CN 2019 2 1198740.5). This device is an integrated design, and the materials used for sputum suction, humidification and flushing are fully enclosed, without air exposure, and can be operated strictly without bacteria. Pulse flushing with syringe can clean the sputum attached to the inner wall and reduce the incidence of VAP. The volume of flushing fluid can be effectively controlled during use to ensure patient safety and reduce waste. It is worth popularizing and applying in clinical practice to optimize the operation steps and reduce the workload of medical staff.


Subject(s)
Pneumonia, Ventilator-Associated , Humans , Incidence , Intensive Care Units , Intubation, Intratracheal/adverse effects , Pneumonia, Ventilator-Associated/etiology , Respiration, Artificial/adverse effects , Sputum , Suction/adverse effects , Suction/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...