Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37702135

ABSTRACT

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
2.
EuroIntervention ; 19(4): e330-e339, 2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37067193

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown. AIMS: We aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut. METHODS: A total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions. RESULTS: The risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth. CONCLUSIONS: The feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access. CLINICALTRIALS: gov: NCT02701283.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Female , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Feasibility Studies , Prosthesis Design , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
3.
J Thorac Cardiovasc Surg ; 166(4): e130-e141, 2023 10.
Article in English | MEDLINE | ID: mdl-37086238

ABSTRACT

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Lacerations , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Lacerations/complications , Lacerations/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Thrombosis/etiology , Aortic Valve Stenosis/surgery , Treatment Outcome
4.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Article in English | MEDLINE | ID: mdl-36858660

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Hospital Mortality , Treatment Outcome , Heart
5.
Cardiovasc Revasc Med ; 46: 85-89, 2023 01.
Article in English | MEDLINE | ID: mdl-35965211

ABSTRACT

OBJECTIVES: We aim to compare in-hospital and 30-day outcomes of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) for native aortic insufficiency (AI). BACKGROUND: TAVR is increasingly used off-label in patients with AI deemed high risk for SAVR. There is a paucity of data comparing TAVR and SAVR with current commercially available TAVR devices. METHODS: A single-center, retrospective cohort study of patients undergoing TAVR or SAVR for native AI between 2014 and 2020 was performed. Data were obtained from the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database, Transcatheter Valve Therapy (TVT) registry, and chart review. In-hospital and 30-day outcomes are reported. RESULTS: Of 125 total patients, 91 underwent SAVR and 34 underwent TAVR. The TAVR group had a higher STS predictive risk of mortality (PROM) (TAVR = 3.96 %, SAVR = 1.25 %, p < 0.0001). In the postoperative period, the SAVR group had higher rates of new-onset atrial fibrillation (20.9 % vs. 0 %, p < 0.001), while the TAVR group had higher rates of complete heart block requiring permanent pacemaker implantation (20.6 % vs. 2.2 %, p < 0.001). There was no difference in in-hospital or 30-day mortality, stroke, myocardial infarction, residual AI, or repeat valve intervention. CONCLUSIONS: Despite higher STS PROM and more comorbidities, patients who underwent TAVR for AI had similar in-hospital and 30-day outcomes as patients who underwent SAVR for AI. These results support TAVR in selected high-risk patients with AI, with the knowledge that pacemaker needs may be higher than patients undergoing SAVR.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Adult , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Retrospective Studies , Treatment Outcome , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Echocardiography , Risk Factors
6.
JACC Case Rep ; 4(20): 1379-1383, 2022 Oct 19.
Article in English | MEDLINE | ID: mdl-36299650

ABSTRACT

Our patient was a 50-year-old woman with tricuspid atresia who had undergone palliation with a Potts shunt to the left pulmonary artery as an infant and a classic Glenn shunt to the right pulmonary artery as a young child. Under general anesthesia, she underwent transcatheter edge-to-edge repair of the mitral valve for severe symptomatic mitral regurgitation. (Level of Difficulty: Advanced.).

7.
Front Cardiovasc Med ; 9: 869259, 2022.
Article in English | MEDLINE | ID: mdl-35811698

ABSTRACT

Background: A clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted. Aims: To quantify the hemodynamic impact of LAMPOON in TMVR using patient-specific computational (in silico) models. Materials: Eight subjects from the LAMPOON investigational device exemption trial were included who had acceptable computed tomography (CT) data for analysis. All subjects were anticipated to be at prohibitive risk of left ventricular outflow tract (LVOT) obstruction from TMVR, and underwent successful LAMPOON immediately followed by TMVR. Using post-procedure CT scans, two 3D anatomical models were created for each subject: (1) TMVR with LAMPOON (performed procedure), and (2) TMVR without LAMPOON (virtual control). A validated computational fluid dynamics (CFD) paradigm was then used to simulate the hemodynamic outcomes for each condition. Results: LAMPOON exposed on average 2 ± 0.6 transcatheter valve cells (70 ± 20 mm2 total increase in outflow area) which provided an additional pathway for flow into the LVOT. As compared to TMVR without LAMPOON, TMVR with LAMPOON resulted in lower peak LVOT velocity, lower peak LVOT gradient, and higher peak LVOT effective orifice area by 0.4 ± 0.3 m/s (14 ± 7% improvement, p = 0.006), 7.6 ± 10.9 mmHg (31 ± 17% improvement, p = 0.01), and 0.2 ± 0.1 cm2 (17 ± 9% improvement, p = 0.002), respectively. Conclusion: This was the first study to permit a quantitative, patient-specific comparison of LVOT hemodynamics following TMVR with and without LAMPOON. The LAMPOON procedure achieved a critical increment in outflow area which was effective for improving LVOT hemodynamics, particularly for subjects with a small neo-left ventricular outflow tract (neo-LVOT).

8.
JACC Cardiovasc Interv ; 15(12): 1249-1263, 2022 06 27.
Article in English | MEDLINE | ID: mdl-35738745

ABSTRACT

BACKGROUND: Transcatheter mitral valve repair is beneficial in patients with mitral regurgitation (MR), left ventricular dysfunction, and persistent symptoms despite maximally tolerated medical therapy. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of transcatheter mitral cerclage ventriculoplasty in patients with MR and either heart failure with reduced ejection fraction or preserved ejection fraction and in subjects with prior edge-to-edge repair but persistent or recurrent symptomatic MR. METHODS: The National Heart, Lung, and Blood Institute Division of Intramural Research Transcatheter Mitral Cerclage Ventriculoplasty Early Feasibility Study (NCT03929913) was an investigator-initiated prospective multicenter study. The primary endpoint was technical success measured at exit from the catheterization laboratory. Follow-up included heart failure quality-of-life assessments and serial imaging with echocardiography and cardiac computed tomography. RESULTS: Nineteen subjects consented and underwent cerclage, 63% with heart failure with reduced ejection fraction and 37% with heart failure with preserved ejection fraction, with ischemic cardiomyopathy in 26% and nonischemic cardiomyopathy in 74%. There were no procedural deaths, strokes, or transient ischemic attacks or other major cardiovascular adverse events. The primary endpoint was met in 17 subjects. Cerclage induced sustained reductions in mitral regurgitant volume (-41%) and effective orifice area (-33%) after a median of 337 days. Cerclage resulted in improvements in 6-minute walking distance (+78 m) and Kansas City Cardiomyopathy Questionnaire Overall Summary Score (+22 points) at 30 days that were maintained after a median of 265 days. New complete heart block developed in 6 of 17 subjects. Three deaths occurred on postprocedural days 79, 159, and 756, unrelated to cerclage. CONCLUSIONS: Transcatheter mitral cerclage ventriculoplasty resulted in significant and sustained improvements in mitral regurgitation and in heart failure quality-of-life assessments.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Ventricular Dysfunction, Left , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Heart Failure/diagnostic imaging , Heart Failure/etiology , Heart Failure/therapy , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome
9.
JACC Cardiovasc Interv ; 15(6): 590-598, 2022 03 28.
Article in English | MEDLINE | ID: mdl-35331450

ABSTRACT

OBJECTIVES: The aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic. BACKGROUND: The COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands. METHODS: Patient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation. RESULTS: From March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106). CONCLUSIONS: SDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Aftercare , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Pandemics , Patient Discharge , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
11.
Circ Cardiovasc Interv ; 14(11): e011028, 2021 11.
Article in English | MEDLINE | ID: mdl-34674556

ABSTRACT

BACKGROUND: Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and laceration of the anterior mitral leaflet to prevent outflow obstruction (LAMPOON) reduce the risk of coronary and left ventricular outflow obstruction obstruction during transcatheter aortic valve replacement and transcatheter mitral valve replacement. Despite successful laceration, BASILICA or LAMPOON may fail to prevent obstruction caused by inadequate leaflet splay in patients having challenging anatomy such as very small valve-to-coronary distance, diffusely calcified, rigid leaflets, or undergoing transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement. We describe a novel technique of balloon-augmented (BA) leaflet laceration to enhance leaflet splay. METHODS: We measured the incremental leaflet splay from BA-BASILICA in vitro. From November 2019 to March 2021, 16 patients underwent BA-BASILICA and 4 BA-LAMPOON at 3 centers. RESULTS: BA-BASILICA increased benchtop leaflet tip splay 17%, maximum splay angle 30%, and splay area 23%, resulting in a more rounded apex and larger effective area. Sixteen patients at risk for inadequate BASILICA leaflet splay, including 4 transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement, underwent BA-BASILICA. All had successful leaflet laceration. One had coronary obstruction requiring immediate orthotopic stenting. Two underwent elective orthotopic coronary stenting through the transcatheter valve cells for leaflet prolapse without coronary ischemia. There were no deaths during the procedure or at 30 days. Four patients at risk for inadequate anterior mitral leaflet splay underwent BA-LAMPOON. All had successful target leaflet laceration without left ventricular outflow obstruction obstruction or procedural death. One died within 30 days. CONCLUSIONS: BA leaflet laceration enhances leaflet splay in vitro and may allow transcatheter aortic valve replacement and transcatheter mitral valve replacement in patients otherwise ineligible for traditional BASILICA or LAMPOON due to challenging anatomy. Graphic Abstract: A graphic abstract is available for this article.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Lacerations , Pectinidae , Transcatheter Aortic Valve Replacement , Animals , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Iatrogenic Disease/prevention & control , Lacerations/etiology , Lacerations/prevention & control , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
JACC Cardiovasc Interv ; 14(20): 2195-2214, 2021 10 25.
Article in English | MEDLINE | ID: mdl-34674861

ABSTRACT

The SAPIEN 3 is the only transcatheter heart valve commercially available for compassionate transcatheter mitral valve replacement in patients with previous mitral surgical rings and mitral annular calcification (valve in ring [VIR] and valve in mitral annular calcification [VIM]). Reported outcomes have been inconsistent or poor. The review provides an overview of the authors' approach to achieve largely consistent results despite the intrinsic limitations of SAPIEN 3 VIM and VIR. The approach includes bedside modifications of the valve implant, the delivery system, and of the cardiac substrate itself. Until purpose-built devices are readily available, VIR and VIM procedures will require aggressive multidisciplinary cooperation, meticulous planning and execution, and postprocedure management by experienced, high-volume operators.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome
13.
JACC Cardiovasc Interv ; 14(9): 941-948, 2021 05 10.
Article in English | MEDLINE | ID: mdl-33958168

ABSTRACT

OBJECTIVES: This study sought to determine the safety of the BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) procedure. BACKGROUND: Transcatheter aortic valve replacement causes coronary artery obstruction in 0.7% of cases, with 40% to 50% mortality. BASILICA is a procedure to prevent coronary obstruction. Safety and feasibility in a large patient cohort is lacking. METHODS: The international BASILICA registry was a retrospective, multicenter, real-world registry of patients at risk of coronary artery obstruction undergoing BASILICA and transcatheter aortic valve replacement. Valve Academic Research Consortium-2 definitions were used to adjudicate events. RESULTS: Between June 2017 and December 2020, 214 patients were included from 25 centers in North America and Europe; 72.8% had bioprosthetic aortic valves and 78.5% underwent solo BASILICA. Leaflet traversal was successful in 94.9% and leaflet laceration in 94.4%. Partial or complete coronary artery obstruction was seen in 4.7%. Procedure success, defined as successful BASILICA traversal and laceration without mortality, coronary obstruction, or emergency intervention, was achieved in 86.9%. Thirty-day mortality was 2.8% and stroke was 2.8%, with 0.5% disabling stroke. Thirty-day death and disabling stroke were seen in 3.4%. Valve Academic Research Consortium-2 composite safety was achieved in 82.8%. One-year survival was 83.9%. Outcomes were similar between solo and doppio BASILICA, between native and bioprosthetic valves, and with the use of cerebral embolic protection. CONCLUSIONS: BASILICA is safe, with low reported rates of stroke and death. BASILICA is feasible in the real-world setting, with a high procedure success rate and low rates of coronary artery obstruction.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Prosthesis Design , Registries , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
Catheter Cardiovasc Interv ; 97(5): 940-947, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33382519

ABSTRACT

OBJECTIVES: We sought to evaluate the safety, efficacy and feasibility of same-day discharge after uncomplicated, minimalist TAVR. BACKGROUND: At the start of the COVID-19 pandemic, we created a same-day discharge (SDD) pathway after conscious sedation, transfemoral (minimalist) TAVR to help minimize risk of viral transmission and conserve hospital resources. Studies support that next-day discharge (NDD) for carefully selected patients following minimalist TAVR is safe and feasible. There is a paucity of data regarding the safety of SDD after TAVR. METHODS: In-hospital and 30 day outcomes of consecutive patients meeting pre-specified criteria for SDD after minimalist TAVR at our institution between March and July of 2020 were reviewed. Outcomes were compared to a NDD cohort from July 2018 through July 2020 that would have met SDD criteria. Primary endpoints were mortality, delayed pacemaker placement, stroke and cardiovascular readmission at 30 days. RESULTS: Twenty nine patients were discharged via the SDD pathway after TAVR. 128 prior NDD patients were identified who met all criteria for SDD. The STS scores were similar between the two groups (SDD 2.6% ±1.5 vs. NDD 2.3% ± 1.2). There were no deaths at 30 days in either group. There was no significant difference in delayed pacemaker placement (SDD 0% vs. NDD 0.8%, p > .99) or cardiovascular readmission (SDD 0% vs. NDD 5.5%, p = .35) at 30 days. CONCLUSIONS: Same day discharge following uncomplicated, minimalist TAVR in selected patients appears to be safe, achieving similar 30 day outcomes as a cohort of next day discharge patients.


Subject(s)
Aortic Valve Stenosis/surgery , COVID-19/epidemiology , Pandemics , Patient Discharge/trends , Risk Assessment/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/epidemiology , Comorbidity , Female , Follow-Up Studies , Humans , Length of Stay/trends , Male , Retrospective Studies , Risk Factors , Time Factors
18.
Methodist Debakey Cardiovasc J ; 13(4): 201-208, 2017.
Article in English | MEDLINE | ID: mdl-29744012

ABSTRACT

Despite advances in the diagnosis and treatment of coronary artery disease (CAD), gender-related disparities continue to exist, and ischemic heart disease mortality in women remains higher than in men. This review will highlight gender-specific differences in the treatment of CAD that may impact outcomes for women. Further studies are needed to clarify the unique pathophysiology of CAD in women and, in turn, create more specific guidelines for its diagnosis, management, and treatment in this patient population.


Subject(s)
Coronary Artery Disease/therapy , Health Status Disparities , Healthcare Disparities , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Evidence-Based Medicine , Female , Humans , Male , Risk Factors , Sex Factors , Treatment Outcome
19.
South Med J ; 109(7): 395-400, 2016 07.
Article in English | MEDLINE | ID: mdl-27364020

ABSTRACT

OBJECTIVES: Patient safety event (PSE) reporting is a critical element for healthcare organizations that are striving for continuous quality improvement. Although resident physicians routinely provide the majority of direct patient care, the level of their participation in PSE reporting historically has been low. In addition, as part of the Accreditation Council for Graduate Medical Education's Next Accreditation System, the Clinical Learning Environment Review site visit assesses residents' engagement in PSE reporting at each accredited academic institution. The objective of this study was to understand the common barriers to PSE reporting and design an intervention to increase the number of PSE reports by resident physicians. METHODS: We surveyed 304 residents and fellows to assess attitudes toward the PSE reporting system and identify barriers to submitting online PSE reports. Based on this analysis of barriers, we piloted interventions with the internal medicine residency program and measured their effect on resident PSE reporting. RESULTS: Of the survey respondents, 58% had never submitted a PSE report. The most commonly identified barriers were too much time required to submit a report (38% of all respondents), lack of education on how or what to report (37%), lack of feedback or change after reporting (19%), and concern for repercussions or lack of anonymity (13%). Based on this analysis of barriers, we piloted interventions with the internal medicine residency program to educate residents about PSE reporting through a reminder message in their orientation e-mail, informational slides at the end of conferences that described what and how to report, a pocket card with reporting instructions, and leadership encouragement during walk rounds by chief medical residents and the program director. Compared with the 10 weeks before the start of the intervention, the number of PSE reports submitted by internal medicine residents more than doubled, from 16 to 37 reports (P < 0.01). This increase in resident PSE reporting was sustained for 20 weeks despite the interventions lasting only 8 weeks. CONCLUSIONS: A resident-driven intervention that fostered a culture of encouragement for PSE reporting through leadership support and targeted education increased the number of PSE reports submitted by internal medicine residents at our health system. Hospitals and health systems should seek to understand the common barriers to PSE reporting from this important group of direct patient care providers and administer structured educational programs to encourage their participation.


Subject(s)
Internal Medicine/education , Internship and Residency , Patient Safety/statistics & numerical data , Risk Management , Attitude of Health Personnel , Communication Barriers , Education/methods , Humans , Internship and Residency/methods , Internship and Residency/standards , Michigan , Program Evaluation , Quality Improvement , Risk Management/methods , Risk Management/standards , Surveys and Questionnaires
20.
Eur Heart J ; 37(24): 1902-9, 2016 Jun 21.
Article in English | MEDLINE | ID: mdl-26377400

ABSTRACT

AIM: The purpose of our study was to evaluate the relative impact of bivalirudin on bleeding outcomes associated with trans-radial interventions (TRI) in real world practice. METHODS AND RESULTS: Data for patients undergoing percutaneous coronary intervention (PCI) between January 2010 and March 2014 at the 47 hospitals participating in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) were utilized. Propensity matching was used within cohorts defined by access site. The impact of bivalirudin use on in-hospital outcomes was evaluated with Fisher's exact tests. Among patients undergoing trans-femoral interventions (TFI), use of bivalirudin was associated with a reduction in bleeding compared with both glycoprotein IIb/IIIa inhibitors (GPI; 1.67 vs. 3.46%, absolute risk reduction (ARR) 1.79%, odds ratio, OR, 0.47, confidence interval, CI, 0.41-0.54, number needed to treat, NNT 56, P < 0.001) and heparin (1.26 vs. 1.76%, ARR 0.5%, OR 0.71, CI 0.61-0.82, NNT 197, P < 0.001). Among patients undergoing TRI, there was a more modest absolute reduction in bleeding with bivalirudin compared with GPI (0.79 vs. 1.41%, ARR 0.62%, OR 0.56, CI 0.34-0.90, NNT 161, P = 0.016) and no difference in bleeding compared with heparin (0.46 vs. 0.46%, OR 1, CI 0.54-1.84, P = 1). CONCLUSION: Bivalirudin is markedly efficacious in reducing bleeding in patients undergoing TFI. The reduction in bleeding associated with bivalirudin use is minimal to absent in patients undergoing TRI. Given its lower cost and comparable outcomes, heparin should be the preferred anticoagulation strategy in those undergoing radial PCI.


Subject(s)
Peptide Fragments/therapeutic use , Anticoagulants , Blue Cross Blue Shield Insurance Plans , Heparin , Hirudins , Humans , Michigan , Percutaneous Coronary Intervention , Platelet Glycoprotein GPIIb-IIIa Complex , Recombinant Proteins/therapeutic use , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...