Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Article in English | MEDLINE | ID: mdl-38818709

ABSTRACT

OBJECTIVE: To report our experience with 18F-fluoro-ethyl-tyrosine (FET) positron emission tomography-computed tomography (PET-CT) co-registered with magnetic resonance imaging (MRI) (FET-PET/MRICR) in the care trajectory for persistent acromegaly. DESIGN: Prospective case series. PATIENTS: Ten patients with insufficiently controlled acromegaly referred to our team to evaluate surgical options. MEASUREMENTS: FET-PET/MRICR was used to support decision-making if MRI alone and multidisciplinary team evaluation did not provide sufficient clarity to proceed to surgery. RESULTS: FET-PET/MRICR showed suspicious (para)sellar tracer uptake in all patients. In five patients FET-PET/MRICR was fully concordant with conventional MRI, and in one patient partially concordant. FET-PET/MRICR identified suggestive new foci in four other patients. Surgical re-exploration was performed in nine patients (aimed at total resection (6), debulking (2), diagnosis (1)), and one patient underwent radiation therapy. In 7 of 9 (78%) operated patients FET-PET/MRICR findings were confirmed intraoperatively, and in six (67%) also histologically. IGF-1 decreased significantly in eight patients (89%). All patients showed clinical improvement. Complete biochemical remission was achieved in three patients (50% of procedures in which total resection was anticipated feasible). Biochemistry improved in five and was unchanged in one patient. No permanent complications occurred. At six months, optimal outcome (preoperative intended goal achieved without permanent complications) was achieved in six (67%) patients and an intermediate outcome (goal not achieved, but no complications) in the other three patients. CONCLUSIONS: In patients with persisting acromegaly without a clear surgical target on MRI, FET-PET/MRICR is a new tracer to provide additional information to aid decision-making by the multidisciplinary pituitary team.

2.
Mol Imaging Biol ; 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775919

ABSTRACT

PURPOSE: To describe the pharmacokinetic properties of the [18F]fluoro-polyethylene glycol(PEG)-folate radiotracer in PET/CT imaging of patients with advanced stage epithelial ovarian cancer (EOC). PROCEDURES: In five patients with advanced EOC (FIGO stage IIIB/IIIC, Fédération Internationale de Gynécologie et d'Obstétrique), a 90-min dynamic PET acquisition of the pelvis was performed directly after i.v. administration of 185 MBq [18F]fluoro-PEG6-folate. Arterial blood samples collected at nineteen timepoints were used to determine the plasma input function. A static volume of interest (VOI) for included tumor lesions was drawn manually on the PET images. Modelling was performed using PMOD software. Three different models (a 1-tissue compartment model (1T2k) and two 2-tissue compartment models, irreversible (2T3k) and reversible (2T4k)) were compared in goodness of fit with the time activity curves by means of the Akaike information criterion. RESULTS: The pharmacokinetic analysis in the pelvic area has proven to be much more challenging than expected. Only four out of 22 tumor lesions in five patients were considered suitable to perform modelling on. The remaining tumor lesions were inapt due to either low tracer uptake, small size, proximity to other [18F]fluoro-PEG6-folate -avid structures and/or displacement by abdominal organ motion in the dynamic scan. Data from the four analyzed tumor lesions suggest that the irreversible 2T3k may best describe the pharmacokinetics. All 22 lesions were immunohistochemically stained positive for the folate receptor alpha (FRα) after resection. CONCLUSION: Performing pharmacokinetic analysis in the abdominal pelvic region is very challenging. This brief article describes the challenges and pitfalls in pharmacokinetic analysis of a tracer with high physiological accumulation in the intestines, in case of lesions of limited size in the abdominal pelvic area.

3.
Nucl Med Commun ; 44(6): 417-426, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-36897051

ABSTRACT

PURPOSE: Improvements in molecular breast imaging (MBI) have increased the use of MBI as adjunct diagnostic modality and alternative to MRI. We aimed to assess the value of MBI in patients with equivocal breast lesions on conventional imaging, especially in terms of its ability to rule out malignancy. METHODS: We selected patients who underwent MBI in addition to conventional diagnostics due to equivocal breast lesions between 2012 and 2015. All patients underwent digital mammography, target ultrasound and MBI. MBI was performed using a single-head Dilon 6800 gamma camera after administration of 600 MBq 99m Tc-sestamibi. Imaging was reported according to BI-RADS classification and compared with pathology or follow-up of ≥6 months. RESULTS: Of 226 women included, pathology was obtained in 106 (47%) and (pre)malignant lesions were found in 25 (11%). Median follow-up was 5.4 years (IQR 3.9-7.1). Sensitivity was higher for MBI compared to conventional diagnostics (84% vs. 32%; P = 0.002), identifying malignancy in 21 and 6 patients, respectively, but specificity did not differ (86% vs. 81%; P = 0.161). Positive and negative predictive value were 43% and 98% for MBI and 17% and 91% for conventional diagnostics. MBI was discordant with conventional diagnostics in 68 (30%) patients and correctly changed diagnosis in 46 (20%) patients, identifying 15 malignant lesions. In subgroups with nipple discharge ( N = 42) and BI-RADS 3 lesions ( N = 113) MBI detected 7 of 8 occult malignancies. CONCLUSION: MBI correctly adjusted treatment in 20% of patients with diagnostic concerns after conventional work-up, and could rule out malignancy with a high negative predictive value of 98%.


Subject(s)
Breast Neoplasms , Mammography , Female , Humans , Mammography/methods , Radionuclide Imaging , Technetium Tc 99m Sestamibi , Gamma Cameras , Predictive Value of Tests , Breast Neoplasms/diagnostic imaging , Sensitivity and Specificity
4.
Cell Rep Med ; 4(2): 100942, 2023 02 21.
Article in English | MEDLINE | ID: mdl-36812890

ABSTRACT

While brown adipose tissue (BAT) is activated by the beta-3-adrenergic receptor (ADRB3) in rodents, in human brown adipocytes, the ADRB2 is dominantly present and responsible for noradrenergic activation. Therefore, we performed a randomized double-blinded crossover trial in young lean men to compare the effects of single intravenous bolus of the ADRB2 agonist salbutamol without and with the ADRB1/2 antagonist propranolol on glucose uptake by BAT, assessed by dynamic 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography-computed tomography scan (i.e., primary outcome). Salbutamol, compared with salbutamol with propranolol, increases glucose uptake by BAT, without affecting the glucose uptake by skeletal muscle and white adipose tissue. The salbutamol-induced glucose uptake by BAT positively associates with the increase in energy expenditure. Notably, participants with high salbutamol-induced glucose uptake by BAT have lower body fat mass, waist-hip ratio, and serum LDL-cholesterol concentration. In conclusion, specific ADRB2 agonism activates human BAT, which warrants investigation of ADRB2 activation in long-term studies (EudraCT: 2020-004059-34).


Subject(s)
Adipose Tissue, Brown , Albuterol , Male , Humans , Albuterol/pharmacology , Propranolol/pharmacology , Glucose/pharmacology , Receptors, Adrenergic , Receptors, Adrenergic, beta-3
5.
Arch Osteoporos ; 17(1): 4, 2021 12 10.
Article in English | MEDLINE | ID: mdl-34893935

ABSTRACT

PURPOSE: To investigate the time and effort needed to perform vertebral morphometry, as well as inter-observer agreement for identification of vertebral fractures on vertebral fracture assessment (VFA) images. METHODS: Ninety-six images were retrospectively selected, and three radiographers independently performed semi-automatic 6-point morphometry. Fractures were identified and graded using the Genant classification. Time needed to annotate each image was recorded, and reader fatigue was assessed using a modified Simulator Sickness Questionnaire (SSQ). Inter-observer agreement was assessed per-patient and per-vertebra for detecting fractures of all grades (grades 1-3) and for grade 2 and 3 fractures using the kappa statistic. Variability in measured vertebral height was evaluated using the intraclass correlation coefficient (ICC). RESULTS: Per-patient agreement was 0.59 for grades 1-3 fracture detection, and 0.65 for grades 2-3 only. Agreement for per-vertebra fracture classification was 0.92. Vertebral height measurements had an ICC of 0.96. Time needed to annotate VFA images ranged between 91 and 540 s, with a mean annotation time of 259 s. Mean SSQ scores were significantly lower at the start of a reading session (1.29; 95% CI: 0.81-1.77) compared to the end of a session (3.25; 95% CI: 2.60-3.90; p < 0.001). CONCLUSION: Agreement for detection of patients with vertebral fractures was only moderate, and vertebral morphometry requires substantial time investment. This indicates that there is a potential benefit for automating VFA, both in improving inter-observer agreement and in decreasing reading time and burden on readers.


Subject(s)
Spinal Fractures , Absorptiometry, Photon , Humans , Lumbar Vertebrae/injuries , Observer Variation , Retrospective Studies , Spinal Fractures/diagnostic imaging , Thoracic Vertebrae
7.
Clin Nucl Med ; 45(10): 771-777, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32701805

ABSTRACT

We review recent technological advances and new clinical indications for sentinel node (SN) and radioguided surgery in order to delineate future tendencies of interventional nuclear medicine in this field. A literature research was performed in PubMed to select relevant articles to be used as key references for analysis of the current approaches and tendencies in SN and radioguided surgery, as well as the evolving contribution of nuclear medicine intervention techniques to the various clinical applications. For classic indications such as melanoma and breast cancer, the incorporation of the SN approach based on the combined use of existing and new preoperative and intraoperative technologies in high-risk patient categories is becoming an emerging area of clinical indication. For SN biopsy staging in other malignancies with more complex lymphatic drainage, the incorporation of sophisticated tools is most helpful. The consecutive use of PET/CT and the SN procedure is increasing as a potential combined approach for the management of specific areas such as the axilla and the pelvis in patients at high risk of regional dissemination. Also, for the management of locoregional metastasis and oligometastatic disease, interventional nuclear medicine techniques are becoming valuable alternatives. The extended experience with SN biopsy is leading to technological advances facilitating the incorporation of this procedure to stage other malignancies with complex lymphatic drainage. New nuclear medicine-based approaches, incorporating SPECT/CT and PET/CT to guide resection of SNs and occult metastases, have recently been gaining ground.


Subject(s)
Image-Guided Biopsy/methods , Nuclear Medicine , Positron Emission Tomography Computed Tomography , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Single Photon Emission Computed Tomography Computed Tomography , Humans , Sentinel Lymph Node/pathology
8.
Metabolism ; 106: 154167, 2020 05.
Article in English | MEDLINE | ID: mdl-31982480

ABSTRACT

AIMS/HYPOTHESIS: Brown adipose tissue (BAT) improves energy metabolism by combusting glucose and lipids into heat. Agonism of the glucagon-like peptide-1 receptor (GLP-1R) within the central nervous system activates BAT in mice. Moreover, in patients with type 2 diabetes, GLP-1R agonism lowers body weight and improves glucose and lipid levels, possibly involving BAT activation. Interestingly, people from South Asian descent are prone to develop cardiometabolic disease. We studied the effect of GLP-1R agonism on BAT in humans, specifically in South Asians and Europids without obesity or type 2 diabetes. METHODS: Twelve Dutch South Asian and 12 age- and BMI-matched Europid nondiabetic men received 12 weeks extended-release exenatide (Bydureon) in this single-arm prospective study. Before and after treatment, BAT was visualized by a cold-induced [18F]FDG-PET/CT scan and a thermoneutral MRI scan, and resting energy expenditure (REE), substrate oxidation, body composition and fasting plasma glucose and serum lipids were determined. Appetite was rated using a visual analogue scale. RESULTS: Since the effect of exenatide on metabolic parameters did not evidently differ between ethnicities, data of all participants were pooled. Exenatide decreased body weight (-1.5 ±â€¯0.4 kg, p < 0.01), without affecting REE or substrate oxidation, and transiently decreased appetite ratings during the first weeks. Exenatide also lowered triglycerides (-15%, p < 0.05) and total cholesterol (-5%, p < 0.05), and tended to lower glucose levels. Notably, exenatide increased BAT metabolic volume (+28%, p < 0.05) and mean standardized uptake value (+11%, p < 0.05) ([18F]FDG-PET/CT), without affecting supraclavicular adipose tissue fat fraction (MRI). CONCLUSIONS/INTERPRETATION: We show for the first time that GLP-1R agonism increases [18F]FDG uptake by BAT in South Asian and Europid men without obesity or type 2 diabetes. TRIAL REGISTRY: Clinicaltrials.gov NCT03002675.


Subject(s)
Adipose Tissue, Brown/drug effects , Adipose Tissue, Brown/metabolism , Energy Metabolism/drug effects , Exenatide/pharmacology , Fluorodeoxyglucose F18/pharmacokinetics , Adipose Tissue, Brown/diagnostic imaging , Adult , Body Composition/drug effects , Body Weight/drug effects , Exenatide/therapeutic use , Humans , Male , Oxidation-Reduction/drug effects , Oxidative Phosphorylation/drug effects , Positron Emission Tomography Computed Tomography , Rest/physiology , Young Adult
9.
Eur J Nucl Med Mol Imaging ; 47(5): 1261-1274, 2020 05.
Article in English | MEDLINE | ID: mdl-31897584

ABSTRACT

PURPOSE: This study aimed to update the clinical practice applications and technical procedures of sentinel lymph node (SLN) biopsy in vulvar cancer from European experts. METHODS: A systematic data search using PubMed/MEDLINE database was performed up to May 29, 2019. Only original studies focused on SLN biopsy in vulvar cancer, published in the English language and with a minimum of nine patients were selected. RESULTS: Among 280 citations, 65 studies fulfilled the inclusion criteria. On the basis of the published evidences and consensus of European experts, this study provides an updated overview on clinical applications and technical procedures of SLN biopsy in vulvar cancer. CONCLUSIONS: SLN biopsy is nowadays the standard treatment for well-selected women with clinically negative lymph nodes. Negative SLN is associated with a low groin recurrence rate and a good 5-year disease-specific survival rate. SLN biopsy is the most cost-effective approach than lymphadenectomy in early-stage vulvar cancer. However, future trials should focus on the safe extension of the indication of SLN biopsy in vulvar cancer. Although radiotracers and optical agents are widely used in the clinical routine, there is an increasing interest for hybrid tracers like indocyanine-99mTc-nanocolloid. Finally, it is essential to standardise the acquisition protocol including SPECT/CT images, and due to the low incidence of this type of malignancy to centralise this procedure in experienced centres for personalised approach.


Subject(s)
Carcinoma , Sentinel Lymph Node , Vulvar Neoplasms , Female , Humans , Lymph Node Excision , Lymph Nodes , Lymphatic Metastasis , Lymphoscintigraphy , Neoplasm Recurrence, Local , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node Biopsy , Vulvar Neoplasms/diagnostic imaging
10.
Clin Nucl Med ; 44(9): 732-734, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31306188

ABSTRACT

This case highlights the use of lymphoscintigraphy with SPECT/CT in patients with previous chest and/or axillary surgery. A 67-year-old woman with a history of left breast carcinoma treated with lumpectomy and radiotherapy, and a second lumpectomy of the ipsilateral breast for a second breast carcinoma, underwent a lymphoscintigraphy for a new left breast lesion. Planar images visualized an alternative lymphatic drainage to the contralateral axilla and to the left paravertebral area. SPECT/CT confirmed sentinel nodes in both stations.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/pathology , Aged , Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Female , Humans , Lymphoscintigraphy , Mastectomy, Segmental , Single Photon Emission Computed Tomography Computed Tomography
11.
Diabetologia ; 61(11): 2386-2397, 2018 11.
Article in English | MEDLINE | ID: mdl-30145664

ABSTRACT

AIMS/HYPOTHESIS: The aim of this study was to evaluate the effect of sitagliptin on glucose tolerance, plasma lipids, energy expenditure and metabolism of brown adipose tissue (BAT), white adipose tissue (WAT) and skeletal muscle in overweight individuals with prediabetes (impaired glucose tolerance and/or impaired fasting glucose). METHODS: We performed a randomised, double-blinded, placebo-controlled trial in 30 overweight, Europid men (age 45.9 ± 6.2 years; BMI 28.8 ± 2.3 kg/m2) with prediabetes in the Leiden University Medical Center and the Alrijne Hospital between March 2015 and September 2016. Participants were initially randomly allocated to receive sitagliptin (100 mg/day) (n = 15) or placebo (n = 15) for 12 weeks, using a randomisation list that was set up by an unblinded pharmacist. All people involved in the study as well as participants were blinded to group assignment. Two participants withdrew from the study prior to completion (both in the sitagliptin group) and were subsequently replaced with two new participants that were allocated to the same treatment. Before and after treatment, fasting venous blood samples and skeletal muscle biopsies were obtained, OGTT was performed and body composition, resting energy expenditure and [18F] fluorodeoxyglucose ([18F]FDG) uptake by metabolic tissues were assessed. The primary study endpoint was the effect of sitagliptin on BAT volume and activity. RESULTS: One participant from the sitagliptin group was excluded from analysis, due to a distribution error, leaving 29 participants for further analysis. Sitagliptin, but not placebo, lowered glucose excursion (-40%; p < 0.003) during OGTT, accompanied by an improved insulinogenic index (+38%; p < 0.003) and oral disposition index (+44%; p < 0.003). In addition, sitagliptin lowered serum concentrations of triacylglycerol (-29%) and very large (-46%), large (-35%) and medium-sized (-24%) VLDL particles (all p < 0.05). Body weight, body composition and energy expenditure did not change. In skeletal muscle, sitagliptin increased mRNA expression of PGC1ß (also known as PPARGC1B) (+117%; p < 0.05), a main controller of mitochondrial oxidative energy metabolism. Although the primary endpoint of change in BAT volume and activity was not met, sitagliptin increased [18F] FDG uptake in subcutaneous WAT (sWAT; +53%; p < 0.05). Reported side effects were mild and transient and not necessarily related to the treatment. CONCLUSIONS/INTERPRETATION: Twelve weeks of sitagliptin in overweight, Europid men with prediabetes improves glucose tolerance and lipid metabolism, as related to increased [18F] FDG uptake by sWAT, rather than BAT, and upregulation of the mitochondrial gene PGC1ß in skeletal muscle. Studies on the effect of sitagliptin on preventing or delaying the progression of prediabetes into type 2 diabetes are warranted. TRIAL REGISTRATION: ClinicalTrials.gov NCT02294084. FUNDING: This study was funded by Merck Sharp & Dohme Corp, Dutch Heart Foundation, Dutch Diabetes Research Foundation, Ministry of Economic Affairs and the University of Granada.


Subject(s)
Adipose Tissue, Brown/drug effects , Adipose Tissue, Brown/metabolism , Dipeptidyl-Peptidase IV Inhibitors/therapeutic use , Overweight/drug therapy , Overweight/metabolism , Prediabetic State/drug therapy , Sitagliptin Phosphate/therapeutic use , Adipose Tissue, White/drug effects , Adipose Tissue, White/metabolism , Adult , Blood Glucose/drug effects , Body Weight/drug effects , Carrier Proteins/genetics , Double-Blind Method , Energy Metabolism/drug effects , Humans , Male , Middle Aged , Muscle, Skeletal/drug effects , Muscle, Skeletal/metabolism , Prediabetic State/metabolism , RNA-Binding Proteins
12.
J Nucl Med ; 2018 Jul 20.
Article in English | MEDLINE | ID: mdl-30030346

ABSTRACT

This study investigates whether radiomic features derived from preoperative positron emission tomography (PET) images could predict both tumor biology and prognosis in women with invasive squamous cell carcinoma of the vulva. Methods: Patients were retrospectively included when they had a unifocal primary cancer of ≥ 2.6 cm in diameter, had received a preoperative 18F-fluorodeoxyglucose (18F-FDG) PET/computed tomography (CT) scan followed by surgery and had at least six months of follow-up data. 18F-FDG-PET images were analyzed by semi-automatically drawing on the primary tumor in each PET image, followed by the extraction of 83 radiomic features. Unique radiomic features were identified by principal component analysis (PCA), after which they were compared with histopathology using non-pairwise group comparison and linear regression. Univariate and multivariate Cox regression analyses were used to correlate the identified features with progression-free survival (PFS) and overall survival (OS). Survival curves were estimated using the Kaplan-Meier method. Results: Forty women were included. PCA revealed four unique radiomic features, which were not associated with histopathologic characteristics such as grading, depth of invasion, lymph-vascular space invasion and metastatic lymph nodes. No statistically significant correlation was found between the identified features and PFS. However, Moran's I, a feature that identifies global spatial autocorrelation, was correlated with OS (P = 0.03). Multivariate Cox regression analysis showed that extracapsular invasion of the metastatic lymph nodes and Moran's I were independent prognostic factors for PFS and OS. Conclusion: Our data show that PCA is usable to identify specific radiomic features. Although the identified features did not correlate strongly with tumor biology, Moran's I was found to predict patient prognosis. Larger studies are required to establish the clinical relevance of the observed findings.

13.
Sci Rep ; 8(1): 8567, 2018 06 04.
Article in English | MEDLINE | ID: mdl-29867076

ABSTRACT

Human brown adipose tissue (BAT) is commonly assessed by cold-induced 18F-fluorodeoxyglucose (FDG) PET-CT using several quantification criteria. Uniform criteria for data analysis became available recently (BARCIST 1.0). We compared BAT volume and activity following BARCIST 1.0 criteria against the most commonly used criteria [Hounsfield Units (HU):-250, -50, standardized uptake value (SUV):2.0; HU: Not applied, SUV:2.0 and HU:-180, -10, SUV:1.5] in a prospective study using three independent cohorts of men including young lean adults, young overweight/obese adults and middle-aged overweight/obese adults. BAT volume was the most variable outcome between criteria. While BAT volume calculated using the HU: NA; SUV: 2.0 criteria was up to 207% higher than the BAT volume calculated based on BARCIST 1.0 criteria, it was up to 57% lower using the HU: -250, -50; SUV: 2.0 criteria compared to the BARCIST 1.0. Similarly, BAT activity (expressed as SUVmean) also differed between different thresholds mainly because SUVmean depends on BAT volume. SUVpeak was the most consistent BAT outcome across the four study criteria. Of note, we replicated these findings in three independent cohorts. In conclusion, BAT volume and activity as determined by 18F-FDG-PET/CT highly depend on the quantification criteria used. Future human BAT studies should conduct sensitivity analysis with different thresholds in order to understand whether results are driven by the selected HU and/or SUV thresholds. The design of the present study precludes providing any conclusive threshold, but before more definitive thresholds for HU and SUV are available, we support the use of BARCIST 1.0 criteria to facilitate interpretation of BAT characteristics between research groups.


Subject(s)
Adipose Tissue, Brown/diagnostic imaging , Electronic Data Processing , Fluorodeoxyglucose F18/administration & dosage , Positron-Emission Tomography , Software , Adolescent , Adult , Humans , Male , Middle Aged , Prospective Studies
14.
Med Phys ; 45(5): 2143-2153, 2018 May.
Article in English | MEDLINE | ID: mdl-29572848

ABSTRACT

PURPOSE: Recent developments in iterative image reconstruction enable absolute quantification of SPECT/CT studies by incorporating compensation for collimator-detector response, attenuation, and scatter as well as resolution recovery into the reconstruction process (Evolution; Q.Metrix package; GE Healthcare, Little Chalfont, UK). The aim of this experimental study is to assess its quantitative accuracy for potential clinical 99m Tc-sestamibi (MIBI)-related SPECT/CT application in neoadjuvant chemotherapy response studies in breast cancer. METHODS: Two phantoms were filled with MIBI and acquired on a SPECT/CT gamma camera (Discovery 670 Pro; GE Healthcare), that is, a water cylinder and a NEMA body phantom containing six spheres that were filled with an activity concentration reflecting clinical MIBI uptake. Subsequently, volumes-of-interest (VOI) of each sphere were drawn (semi)automatically on SPECT using various isocontour methods or manually on CT. Finally, prone MIBI SPECT/CT scans were acquired 5 and 90 min p.i. in a locally advanced breast cancer patient. RESULTS: Activity concentration in the four largest spheres converged after nine iterations of evolution. Depending on the count statistics, the accuracy of the reconstructed activity concentration varied between -4.7 and -0.16% (VOI covering the entire phantom) and from 6.9% to 10% (8.8 cm ⌀ cylinder VOI placed in the center of the phantom). Recovery coefficients of SUVmax were 1.89 ± 0.18, 1.76 ± 0.17, 2.00 ± 0.38, 1.89 ± 0.35, and 0.90 ± 0.26 for spheres with 37, 28, 22, 17, and 13 mm ⌀, respectively. Recovery coefficients of SUVmean were 1.07 ± 0.06, 1.03 ± 0.09, 1.17 ± 0.21, 1.10 ± 0.20, and 0.52 ± 0.14 (42% isocontour); 1.10 ± 0.07, 1.02 ± 0.09, 1.13 ± 0.19, 1.06 ± 0.19, and 0.51 ± 0.13 (36% isocontour with local background correction); and 0.96, 1.09, 1.03, 1.03, and 0.29 (CT). Patient study results were concordant with the phantom validation. CONCLUSIONS: Absolute SPECT/CT quantification of breast studies using MIBI seems feasible (<17% deviation) when a 42% isocontour is used for delineation for tumors of at least 17 mm diameter. However, with tumor shrinkage, response evaluation should be handled with caution, especially when using SUVmax .


Subject(s)
Breast Neoplasms/diagnostic imaging , Image Processing, Computer-Assisted/methods , Single Photon Emission Computed Tomography Computed Tomography , Aged , Breast Neoplasms/drug therapy , Female , Humans , Neoadjuvant Therapy , Phantoms, Imaging , Signal-To-Noise Ratio , Technetium Tc 99m Sestamibi
15.
Breast Cancer Res Treat ; 169(3): 513-522, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29435855

ABSTRACT

PURPOSE: To investigate the clinical utility of molecular breast imaging (MBI) in patients with proven invasive breast cancer scheduled for breast-conserving surgery (BCS). METHODS: Following approval by the institutional review board and written informed consent, records of patients with newly diagnosed breast cancer scheduled for BCS who had undergone MBI for local staging in the period from March 2012 till December 2014 were retrospectively reviewed. RESULTS: A total of 287 women (aged 30-88 years) were evaluated. MBI showed T stage migration in 26 patients (9%), with frequent detection of in situ carcinoma around the tumor. Surgical management was adjusted in 14 of these patients (54%). In 17 of 287 patients (6%), MBI revealed 21 proven additional lesions in the ipsilateral, contralateral breast or both. In 18 of these additional foci (86%), detected in 15 patients, malignancy was found. Thirteen of these 15 patients had ipsilateral cancer and 2 patients bilateral malignancy. In total, MBI revealed a larger tumor extent, additional tumor foci or both in 40 patients (14%), leading to treatment adjustment in 25 patients (9%). CONCLUSION: MBI seems to be a useful imaging modality with a high predictive value in revealing ipsilateral and bilateral disease not visualized by mammography and ultrasound. It may play an important role in delineating the extent of the index lesion during preoperative planning. Incorporation of MBI in the clinical work-up as an adjunct modality to mammography and ultrasound may lead to better selection of patients who could benefit from BCS.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Molecular Imaging , Adult , Aged , Aged, 80 and over , Breast Neoplasms/surgery , Female , Humans , Image Processing, Computer-Assisted , Mammography , Mastectomy, Segmental/methods , Middle Aged , Molecular Imaging/methods , Neoplasm Invasiveness , Neoplasm Staging , Preoperative Care , Retrospective Studies , Treatment Outcome , Tumor Burden
16.
Clin Breast Cancer ; 18(1): 9-18, 2018 02.
Article in English | MEDLINE | ID: mdl-28728876

ABSTRACT

BACKGROUND: Interest in technetium-99m (99mTc)-sestamibi imaging for neoadjuvant chemotherapy (NAC) response monitoring in locally advanced breast cancer (LABC) is increasing but remains matter of discussion. The present study conducted a meta-analysis of the diagnostic performance of 99mTc-sestamibi to predict pathologic nonresponse to NAC for primary LABC. MATERIALS AND METHODS: A systematic data search was performed. Studies with a minimum of 10 LABC patients that had evaluated 99mTc-sestamibi imaging for NAC nonresponse using conventional planar scintimammography, breast-specific γ-imaging, and/or single photon emission computed tomography/computed tomography (SPECT/CT) were included. The histopathologic findings were the reference standard. The meta-analysis was performed using a mixed logistic regression model. RESULTS: The search revealed 14 eligible studies with 529 patients. Of the 14 studies, 11 had evaluated scintimammography and 3 breast-specific γ-imaging. No studies examining SPECT or SPECT/CT were found. The overall estimated pooled sensitivity, specificity, and positive and negative likelihood ratios of 99mTc-sestamibi imaging to predict nonresponsiveness to NAC were 70.3% (95% confidence interval [CI], 56.5%-81.3%%), 90.1% (95% CI, 77.5%-96.0%), 7.13 (95% CI, 3.08-16.53), and 0.33 (95% CI, 0.22-0.49), respectively. Only 3 studies (107 patients) evaluated 99mTc-sestamibi imaging during NAC, reported an estimated pooled sensitivity of 87% (95% CI, 72%-100%) and specificity of 93% (95% CI, 85%-100%). CONCLUSION: Only planar 99mTc-sestamibi imaging has been investigated for NAC nonresponse in LABC but showed low sensitivity to predict pathologic nonresponse. However, most studies focused on the prediction of pathologic complete response after NAC. Although experience is limited, 99mTc-sestamibi uptake during NAC seems highly sensitivity for the prediction of nonresponsiveness. Features such as SPECT/CT imaging, standardized quantification, relation to tumor subtypes, and proper timing have been insufficiently evaluated and require further investigation.


Subject(s)
Antineoplastic Agents/therapeutic use , Breast Neoplasms/therapy , Mammography/methods , Radiopharmaceuticals/administration & dosage , Technetium Tc 99m Sestamibi/administration & dosage , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Drug Resistance, Neoplasm , Feasibility Studies , Female , Humans , Neoadjuvant Therapy/methods , Radionuclide Imaging/methods , Sensitivity and Specificity , Single Photon Emission Computed Tomography Computed Tomography/methods , Treatment Outcome
17.
Ned Tijdschr Geneeskd ; 160: A9610, 2016.
Article in Dutch | MEDLINE | ID: mdl-26786798

ABSTRACT

Breast-specific gamma imaging (BSGI) is a new technique in nuclear medicine for the diagnosis of breast cancer. After intravenous injection of the radioactive substance 99mTc-sestamibi the breasts are imaged with a gamma camera. The radionuclide assimilates into intracellular mitochondria, which are present in greater numbers in breast cancer cells than in normal cells. This causes a relatively high uptake of the radionuclide in tumours. Along with mammography and ultrasound, MRI is the current gold standard in breast imaging diagnostics. However, MRI is a complex and expensive procedure and has low specificity leading to high false-positive rates. BSGI has equally high sensitivity but is more specific, cheaper and much simpler to interpret. BSGI could replace MRI as a complementary technique to show, exclude or indicate the extent of breast cancer.


Subject(s)
Breast Neoplasms/diagnosis , Gamma Cameras/standards , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Female , Humans , Magnetic Resonance Imaging/methods , Mammography , Organ Specificity , Radionuclide Imaging , Sensitivity and Specificity , Technetium Tc 99m Sestamibi
18.
J Immunol Methods ; 283(1-2): 115-24, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14659904

ABSTRACT

The serodiagnosis of tuberculosis has long been the subject of investigation, but we still lack a test with widespread clinical utility. The poor sensitivity and specificity of commercial assays precludes their use as the sole means of diagnosis. All of these assays use mycobacterial antigens adsorbed onto a surface. Little attention has been paid to changes in antigen conformation that may occur as a result of passive coating of these antigens to solid supports like polystyrene. Such changes may cause technical artifacts resulting in false-positive (FP) and false-negative (FN) reactions. We have developed two different enzyme-linked immunosorbent assay (ELISA) systems, in which human serum antibodies and target antigens of Mycobacterium tuberculosis are able to associate and dissociate freely in solution to form immune complexes. In one ELISA, rabbit antibodies against M. tuberculosis, passively coated in the ELISA wells, capture the immune complexes (ICs). In the other ELISA, the ICs are detected by these same rabbit antibodies but are first captured by passively coated goat anti-rabbit IgG. We have compared these two ELISA systems with an ELISA using M. tuberculosis antigens passively adsorbed to the solid polystyrene surface of the plate. We studied sera from 81 patients with tuberculosis and 47 healthy subjects. The differences between tuberculosis (TB) patients and healthy subjects were statistically significant in all three of our ELISA systems. However, the ELISA systems using soluble M. tuberculosis antigens distinguished better between TB patients and healthy subjects than the ELISA using surface-adsorbed M. tuberculosis antigens. We suggest that in the latter ELISA, passive adsorption of the target antigens induces conformational change, generating altered epitopes that are recognized by antibodies present in the serum from even healthy people. These altered conformational epitopes are recognized by antibodies that were originally evoked by antigens other than M. tuberculosis, known as heterophile antigens.


Subject(s)
Antigen-Antibody Complex/blood , Enzyme-Linked Immunosorbent Assay/methods , Tuberculosis/diagnosis , Animals , Antigens, Bacterial/chemistry , Antigens, Bacterial/immunology , False Negative Reactions , False Positive Reactions , Humans , Protein Conformation , Rabbits , Serologic Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...