Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Diagnostics (Basel) ; 14(10)2024 May 19.
Article in English | MEDLINE | ID: mdl-38786352

ABSTRACT

Vascular calcifications in aorto-iliac arteries are emerging as crucial risk factors for cardiovascular diseases (CVDs) with profound clinical implications. This systematic review, following PRISMA guidelines, investigated methodologies for measuring these calcifications and explored their correlation with CVDs and clinical outcomes. Out of 698 publications, 11 studies met the inclusion criteria. In total, 7 studies utilized manual methods, while 4 studies utilized automated technologies, including artificial intelligence and deep learning for image analyses. Age, systolic blood pressure, serum calcium, and lipoprotein(a) levels were found to be independent risk factors for aortic calcification. Mortality from CVDs was correlated with abdominal aorta calcification. Patients requiring reintervention after endovascular recanalization exhibited a significantly higher volume of calcification in their iliac arteries. Conclusions: This review reveals a diverse landscape of measurement methods for aorto-iliac calcifications; however, they lack a standardized reproducibility assessment. Automatic methods employing artificial intelligence appear to offer broader applicability and are less time-consuming. Assessment of calcium scoring could be routinely employed during preoperative workups for risk stratification and detailed surgical planning. Additionally, its correlation with clinical outcomes could be useful in predicting the risk of reinterventions and amputations.

2.
Int Angiol ; 43(2): 271-279, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38502543

ABSTRACT

INTRODUCTION: The purpose of this study is to report incidence, indications, and outcomes of early open conversions (EOC) after endovascular aortic repair (EVAR), defined as surgical conversion performed within 30 days from the initial EVAR. EVIDENCE AQUISITION: A systematic review of the literature was performed (database searched: PubMed, Web of Science, Scopus, Cochrane Library; last search April 2023). Articles reporting EOC after EVAR comprising at least five patients were included. Meta-analyses of proportions were performed using a random-effects model. EVIDENCE SYNTHESIS: Seventeen non-randomized studies, published between 1999 and 2022, were included. A total of 35,970 patients had previously undergone EVAR, of these 438 patients underwent EOC. Estimated incidence of EOC was 1.4% (95% CI 1.1-1.4; I2=81.66%). Specifically, in the works published before 2010 the incidence was 1.8% (95% CI 1.3-2.4; I2=74.25) while for subsequent ones it was 0.9% (95% CI 0.6-1.1; I2=69.82). Weighted mean age was 74.91 years (95% CI 72.42-77.39; I2=83.11%). Estimated rate of cause determining EOC were: access issue in 27.7% of patients (95% CI 13.8-41.6; I2=88.14%), incorrect placement of the endograft in 20.1% (95% CI 10.2-30.0; I2=76,9%), problems with "delivery system" in 9.0% (95% CI 4.9-13.1; I2=0%), aorto-iliac rupture in 8.6% (95% CI 4.5-12.6; I2=0%), endoprosthesis migration in 7.9% of cases (95% CI 3.3-12.4; I2=22.96%), failure in engaging the contralateral gate in 4.8% (95% CI 1.6-8; I2=0%), "kinking" or "twisting" of endoprosthesis in 3.3% (95% CI 0.6-5.9; I2=0%), graft thrombosis in 3.2% (95% CI 0.6-5.7; I2=0%), type Ia endoleak in 2.9% (95% CI 0.4-5.4; I2=0%), type III endoleak in 2.8% (95% CI 0.3-5.3; I2=0%) and endograft infection in 2.7% (95% CI 0.3-5.2; I2=0%). Intraoperative conversion rate was 91.1% (95% CI 85.8-96.4; I2=66.01%). Early mortality rate after EOC was 14.5% (95% CI 9.1-19.9; I2=48.31%). Mean length of stay (LOS) was 11.94 days (95% CI 6.718-17.172; I2=92.34%). CONCLUSIONS: The incidence of EOC seems to decrease over time. Causes of EOC were mainly related to access problems and incorrect positioning of the endograft. Most of the EOC were performed intraoperatively carrying a high mortality rate.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Incidence , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Treatment Outcome , Conversion to Open Surgery , Risk Factors , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Time Factors
3.
Bioengineering (Basel) ; 11(2)2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38391683

ABSTRACT

There is currently a shift in surgical training from traditional methods to simulation-based approaches, recognizing the necessity of more effective and controlled learning environments. This study introduces a completely new 3D-printed modular system for endovascular surgery training (M-SET), developed to allow various difficulty levels. Its design was based on computed tomography angiographies from real patient data with femoro-popliteal lesions. The study aimed to explore the integration of simulation training via a 3D model into the surgical training curriculum and its effect on their performance. Our preliminary study included 12 volunteer trainees randomized 1:1 into the standard simulation (SS) group (3 stepwise difficulty training sessions) and the random simulation (RS) group (random difficulty of the M-SET). A senior surgeon evaluated and timed the final training session. Feedback reports were assessed through the Student Satisfaction and Self-Confidence in Learning Scale. The SS group completed the training sessions in about half time (23.13 ± 9.2 min vs. 44.6 ± 12.8 min). Trainees expressed high satisfaction with the training program supported by the M-SET. Our 3D-printed modular training model meets the current need for new endovascular training approaches, offering a customizable, accessible, and effective simulation-based educational program with the aim of reducing the time required to reach a high level of practical skills.

5.
Angiology ; 75(4): 314-322, 2024 Apr.
Article in English | MEDLINE | ID: mdl-36891765

ABSTRACT

The present study reported the outcomes of different treatments for innominate artery (IA) atherosclerotic stenosis or occlusion. We performed a systematic review of the literature (4 database searched; last search February 2022), including articles with ≥5 patients. We performed meta-analyses of proportions for different postoperative outcomes. Fourteen studies were included (656 patients; 396 underwent surgery, 260 endovascular procedures). IA lesions were asymptomatic in 9.6% (95% CI 4.6-14.6). Overall estimated technical success (TS) rate was 91.7% (95% CI 86.9-96.4); weighted TS rate was 86.8% (95% CI 75-98.6) in the surgical group (SG), 97.1% (95% CI 94.6-99.7) in the endovascular group (EG). Postoperative stroke in SG was 2.5% (95% CI 1-4.1) and 2.1% in EG (95% CI .3-3.8). Overall, 30-day occlusion was estimated .9% (95% CI 0-1.8) in SG and .7% (95% CI 0-1.7) in EG. Thirty-day mortality was 3.4% (95% CI .9-5.8) in SG and .7% (95% CI 0-1.7) in EG. Estimated mean follow-up after intervention was 65.5 months (95% CI 45.5-85.5) in SG and 22.4 months (95% CI 14.72-30.16) in EG. During follow-up, restenosis in SG were 2.8% (95% CI .5-5.1) and 16.6% (95% CI 5- 28.1) in EG. In conclusion, the endovascular approach seems to offer good short to mid-term outcomes, but with a higher rate of restenosis during follow-up.


Subject(s)
Atherosclerosis , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Constriction, Pathologic/surgery , Brachiocephalic Trunk/surgery , Atherosclerosis/therapy , Treatment Outcome , Stents
6.
Vasc Endovascular Surg ; 58(2): 223-229, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37641383

ABSTRACT

Spinal cord ischemia leading to paraplegia is a rare, life-limiting complication of acute type B aortic dissection. We report a case of spinal cord ischemia occurred in a young woman treated with endovascular scissor technique in urgent setting. The patient had an uneventful post-procedural course. After 4 months, computed tomography angiography confirmed false lumen reperfusion and major symptoms were regressed. In selected cases, this procedure is a tool to improve false lumen perfusion in type B dissections, and demonstrated to be helpful in our case of spinal cord ischaemia.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Female , Humans , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Treatment Outcome , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Spinal Cord Ischemia/diagnostic imaging , Spinal Cord Ischemia/etiology , Paraplegia/etiology , Retrospective Studies , Spinal Cord
7.
J Endovasc Ther ; : 15266028231210220, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38009322

ABSTRACT

BACKGROUND: Chronic limb-threatening ischemia (CLTI) is known for its high rates of major amputation and mortality. Conventional revascularization techniques often fail in CLTI patients due to the heavily diseased arteries. Foot vein arterialization (FVA) has been proposed as an alternative technique to provide arterial blood to the foot by using the disease-free venous bed. OBJECTIVES: This systematic review and meta-analysis aimed to determine outcomes of surgical FVA (sFVA) and percutaneous FVA (pFVA) at 6 and 12 months post-procedure. DATA SOURCES: PubMed, Scopus, Web of Science, and the Cochrane Library databases were searched to identify papers reporting clinical outcomes of sFVA and pFVA published between January 1966 and March 2023. METHODS: Databases were searched for eligible studies. A meta-analysis was performed to evaluate the limb salvage rate, overall survival rate, and wound healing rate at 6 and 12 months. RESULTS: A total of 27 studies were included, with 753 patients and 793 limbs. Of the included studies, 16 analyzed the sFVA technique and 11 the pFVA technique. Of the included patients, 86.3% were Rutherford 5/6 in the sFVA group versus 98.4% in the pFVA group. The pooled limb salvage rate at 6 and 12 months was 78.1% and 74.1% in the sFVA group and 81.7% and 78.6% in the pFVA group, respectively. Wound healing rates were not reported in the sFVA group. In the pFVA group, the pooled wound healing rates were 48.1% and 64.5% at 6 and 12 months, respectively. CONCLUSION: This study showed promising results after FVA among a large population of CLTI patients. In high-risk patients, pFVA is a feasible option with favorable limb salvage and wound healing rates.

8.
Angiology ; : 33197231206430, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37820380

ABSTRACT

We report a multicenter experience of open conversions (OC) for aortic endograft infections (AEI). We retrospectively analyzed all patients who underwent OC for AEI after endovascular aneurysm repair (EVAR), from 1997 to 2021 in 12 Italian centers. The endpoints were as follows: mortality (30-days, in-hospital), major postoperative complications. Follow-up data included: survival, aortic-related complications, infection persistence or reoccurrence. Fifty-eight patients (mean age: 73.8 ± 6.6 years) were included. Median time from EVAR to OC was 14 months (interquartile range 7-45). Thirty-five patients (60.3%) were symptomatic at presentation. Aortic reconstruction was anatomic in 32 patients (55.2%), extra-anatomic in 26 (44.8%). Thirty-day mortality was 31% (18/58). Six additional patients died after 30 days during the same hospitalization (in-hospital mortality: 41.4%). Most common post-operative complications included respiratory failure (38.6%) and renal insufficiency (35.1%). During 28.1 ± 4 months follow-up, 4 aneurysm-related deaths were recorded. Infection re-occurred in 29.4% of the patients. Estimated survival was 50% at 1 year, and 30% at 5 years, and was significantly lower for patients who underwent extra-anatomic reconstructions (37 vs 61% at 1 year, 16 vs 45% at 5 years; log-rank P = .021). OC for AEI is associated with high early mortality. The poor mid-term survival is influenced by aortic complications and infection re-occurrence.

9.
Vasc Endovascular Surg ; 57(8): 949-953, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37309678

ABSTRACT

PURPOSE: Abdominal aortic aneurysms (AAA) are observed in 6% of patients with concomitant aortic valve stenosis (AS) requiring aortic valve replacement. Optimal management of these concomitant pathologies is still debated. CASE REPORT: An 80-year-old man presented with acute heart failure due to a severe AS. Past medical history included AAA under regular surveillance. A thoracic and abdominal computed tomography angiography (CTA) confirmed a 6 mm increase of AAA over an 8-month period (max 55 mm). A multidisciplinary team prescribed a simultaneous endovascular approach of transcatheter aortic valve implantation (TAVI) followed by endovascular aneurysm repair (EVAR) under local anaesthesia with bilateral femoral percutaneous access. No intra or post-procedural complications were registered; technical success was confirmed by completion angiography and post-operative ultrasound. The patient was discharged on postoperative day 5. A 2-month post-operative CTA confirmed ongoing technical success. CONCLUSION: Combined TAVI and EVAR under local anaesthesia for AS and AAA was associated with reduced hospital stay and technical success at 2 months from intervention in this case report.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Valve Stenosis , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Humans , Male , Anesthesia, Local , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Aortic Valve , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Blood Vessel Prosthesis Implantation/methods , Endovascular Aneurysm Repair , Endovascular Procedures/methods , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
10.
Vascular ; 31(1): 98-106, 2023 Feb.
Article in English | MEDLINE | ID: mdl-34923864

ABSTRACT

BACKGROUND: The following study investigated the 30-day and 5-year relative survival rate and freedom from neurological events in asymptomatic carotid stenosis (ACS) octogenarians who had undergone elective carotid endarterectomy (CEA). METHODS: Between January 2008 and June 2014, a retrospective review was conducted on ACS patients who had undergone elective CEA. The patients' sample was divided into two groups: Group A (GA) included octogenarians and Group B (GB) included younger patients. The GA patients were subjected to a risk-scoring system and follow-up. The two groups were compared analysing the following primary endpoints: 30-day mortality, stroke, stroke/death and acute myocardial infarction (AMI); GA patients' survival rate and freedom from neurological events at 5 years. The 30-day secondary endpoints included carotid shunting, redo surgical, need for general anaesthesia with preserved consciousness (GAPC) conversion and length of hospital stay. RESULTS: We identified 620 patients with ACS, of them 144 (23.2%) belonged to the GA and 476 (76.8%) belonged to the GB. No statistical difference between the two groups was found regarding the primary and secondary endpoints. One hundred nineteen of 144 GA patients (82.6%) underwent the follow-up; the median follow-up was 78.3 months. The GA patients' 5-year survival rate was 62%, while freedom from cerebral events was 94.9%. Analysis regarding GA patients' 5-year survival rate revealed a significantly lower percentage among the patients with a severe risk score compared with those with a moderate risk score (respectively, 29.5% vs 67.7%; p = .005). The multivariate analysis showed that chronic obstructive pulmonary disease (COPD) and chronic kidney disease (CKD) were independently associated with lower survival. CONCLUSIONS: The 30-day outcomes of CEA in octogenarians are comparable to those in younger patients. Comprehensive life expectancy and preoperative score, rather than age alone, should be taken into account before performing CEA on octogenarian patients, considering the short- and long-term efficacy in stroke prevention.


Subject(s)
Carotid Stenosis , Endarterectomy, Carotid , Stroke , Aged, 80 and over , Humans , Endarterectomy, Carotid/adverse effects , Octogenarians , Treatment Outcome , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/surgery , Stroke/etiology , Risk Factors , Retrospective Studies , Risk Assessment , Asymptomatic Diseases
11.
Ann Vasc Surg ; 88: 327-336, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35921977

ABSTRACT

BACKGROUND: Endovascular aortic repair (EVAR), currently the preferred treatment for abdominal aortic aneurysm (AAA), has been described also for penetrating aortic ulcers (PAU) of the infrarenal aorta. However, data on its performance in this particular setting are still sparse in the literature. Aim of this study is to compare patient clinical characteristics, aorto-iliac features, and post-operative outcomes between infrarenal PAU and AAA treated by standard EVAR. METHODS: In this retrospective observational case-control multicenter study, the patients treated for infrarenal PAU (G1) with EVAR in 2 high-volume European centers from January 2014 to December 2019 were prospectively entered into a dedicated database and retrospectively analyzed. A 4-fold control group (G2) of infrarenal AAA patients, homogeneous for age and gender, was also considered. Preoperative clinical characteristics, aorto-iliac features (rupture, aortic maximum diameter, proximal neck diameter and length, aortic bifurcation diameter, distance between the lowest renal artery and the aortic bifurcation [RA-AoBi], severe aortic calcification), technical success, 30-day (morbidity, reintervention, complications, mortality) and follow-up outcomes (freedom from reintervention [FFR] and survival) were compared in the 2 groups (chi square/Fisher exact test, t-student test, Mann-Whitney test, logistic regression and Kaplan-Meier analysis). RESULTS: Seventy-three patients (age 78 ± 7 years; male 84.9%) were included in G1 and 299 (age 78.4 ± 6.6 years; male 89.3%) in G2. At the time of diagnosis, G1 patients were more often symptomatic compared with G2 (odds ratio OR 10.21, 95% confidence interval CI 4.17-24.99, P < 0.001). At preoperative computed tomography angiography, G1 patients had more ruptures (OR 8.11, 95% CI 3.50-18.78, P < 0.001), smaller maximum diameter (OR 1.05, 95% CI 1.03-1.08, P < 0.001), longer and narrower proximal neck (OR 0.97, 95% CI 0.95-0.99, P = 0.020 and OR 1.47, 95% CI 1.32-1.64, P < 0.001, respectively) narrower aortic bifurcation (OR 1.34, 95% CI 1.24-1.45, P < 0.001), lower RA-AoBi (OR 1.09, 95% CI 1.07-1.12, P < 0.001), and more severe aortic calcification (OR 57, 95% CI 16-198, P = 0.001). Technical success (G1 98.6% vs G2 95.7% P = 0.320), 30-day morbidity (G1 2.7% vs G2 8.7% P = 0.133), reintervention (G1 2.7% vs G2 2.3% P = 0.691), complications (G1 6.8% vs G2 8% P = 0.737) and mortality (G1 1.4% vs 2% P = 0.720) were comparable in the 2 groups. The mean follow-up was 17.7 ± 16.4 months in G1 and 18.8 ± 15.1 in G2 (P = 0.576). Late FFR and survival were comparable in the 2 groups (1-year FFR: G1 94.8% vs G2 97.5%, P = 0.995; 1-year survival: G1 91.7% vs G2 92.3%, P = 0.960). CONCLUSIONS: Infrarenal PAU are more often symptomatic with a higher rupture rate compared to infrarenal AAA. Despite some negative anatomical characteristics (narrower aortic bifurcation, lower RA-AoBi, extensive calcification), the results of EVAR are extremely satisfactory in this setting, suggesting that endovascular exclusion could be considered a valid treatment for infrarenal PAU.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Penetrating Atherosclerotic Ulcer , Humans , Male , Aged , Aged, 80 and over , Retrospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis , Endovascular Procedures/adverse effects , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/surgery , Risk Factors
12.
Int Angiol ; 41(6): 476-482, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36121171

ABSTRACT

BACKGROUND: An occult endoleak (OE) may be the underlying cause of aneurysm sac expansion after endovascular aneurysm repair (EVAR). The aim of this study is to describe intraoperative findings of OE during surgical endograft explantations. METHODS: This is a retrospective, multicenter analysis of all open conversions (OC) after EVAR from 1997 to 2020 in 12 vascular centers. We excluded patients with a preoperative diagnosis of endograft infection, endograft thrombosis, and thoracic-EVAR. An OE was defined as an endoleak revealed during OC not shown on preoperative imaging, which was likely the real cause for sac enlargement. We reported the number of OE, and we described the type of OE in relation to the initial alleged or associated endoleak. A separate analysis of patients with an initial diagnosis of endotension was also performed. RESULTS: An OE was found in 32/255 patients (12.5%). In the 78.1% of the cases (25/32) a type II endoleak hid a type I or III endoleak. Endotension was the initial diagnosis of 26/255 patients (10.2%). In 4/26 cases (15.4%), a type I or II OE was revealed. In 5/26 cases (19.2%) an endograft infection was found intraoperatively. In 2/26 cases we found an angiosarcoma. Fifteen cases of endotension (57.7%) remained unexplained. CONCLUSIONS: OE represent a not negligible cause of EVAR failure. A type II endoleak associated with sac enlargement may actually conceal a higher-flow endoleak. In most of the cases, the initial diagnosis of endotension remains unexplained. However, endotension sometimes conceals severe underlying pathologies such as infections.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Endovascular Procedures/adverse effects , Treatment Outcome , Blood Vessel Prosthesis/adverse effects , Risk Factors
13.
J Cardiovasc Surg (Torino) ; 63(3): 328-352, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35658387

ABSTRACT

The objective of these Guidelines was to revise and update the previous 2016 Italian Guidelines on Abdominal Aortic Aneurysm Disease, in accordance with the National Guidelines System (SNLG), to guide every practitioner toward the most correct management pathway for this pathology. The methodology applied in this update was the GRADE-SIGN version methodology, following the instructions of the AGREE quality of reporting checklist as well. The first methodological step was the formulation of clinical questions structured according to the PICO (Population, Intervention, Comparison, Outcome) model according to which the Recommendations were issued. Then, systematic reviews of the Literature were carried out for each PICO question or for homogeneous groups of questions, followed by the selection of the articles and the assessment of the methodological quality for each of them using qualitative checklists. Finally, a Considered Judgment form was filled in for each clinical question, in which the features of the evidence as a whole are assessed to establish the transition from the level of evidence to the direction and strength of the recommendations. These guidelines outline the correct management of patients with abdominal aortic aneurysm in terms of screening and surveillance. Medical management and indication for surgery are discussed, as well as preoperative assessment regarding patients' background and surgical risk evaluation. Once the indication for surgery has been established, the options for traditional open and endovascular surgery are described and compared, focusing specifically on patients with ruptured abdominal aortic aneurysms as well. Finally, indications for early and late postoperative follow-up are explained. The most recent evidence in the Literature has been able to confirm and possibly modify the previous recommendations updating them, likewise to propose new recommendations on prospectively relevant topics.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Rupture , Endovascular Procedures , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/methods , Humans , Italy/epidemiology , Treatment Outcome
14.
J Vasc Surg ; 76(1): 104-112, 2022 07.
Article in English | MEDLINE | ID: mdl-35085746

ABSTRACT

OBJECTIVE: The aim of this study is to compare early and follow-up outcomes of late open conversions (LOC, with complete or partial endograft explantation) and semi-conversions (SC, with endograft preservation) after endovascular aneurysm repair in a multicenter experience. METHODS: All LOC and SC performed from 1997 to 2020 in 11 vascular centers were compared. Endograft infections or thrombosis were excluded. Primary endpoints were early mortality and long-term survival estimates. Secondary endpoints were differences in postoperative complication rates and conversion-related complications during follow-up. RESULTS: In the considered period, 347 patients underwent surgery for endovascular aneurysm repair complications. Among these, 270 were operated on for endoleaks (222 LOC, 48 SC). The two groups were homogeneous in terms of American Society of Anesthesiologists score (LOC, 3.2 ± 0.7; SC, 3 ± 0.5; P = .128) and main endograft characteristics (suprarenal fixation, bifurcated/aorto-uni-iliac configuration). The mean age was 75 ± 8 years for LOC and 79 ± 7 years for SC (P = .009). Reasons for LOC were: 62.2% (138/222) type I endoleak, 21.6% (48/222) type II endoleak, 7.7% (17/222) type III endoleak, and 8.5% (19/222) endotension. Indications for SC were: 64.6% (31/48) type II endoleak, 33.3% (16/48) type I endoleak, and 2.1% (1/48) type III endoleak. Thirty-day mortality was 12.2% (27/222) in the LOC group, and 10.4% (5/48) in the SC group (P = .73). Postoperative complication rate was higher in the LOC group (45.5% vs 29.2%; P = .04). The estimated survival rate after LOC was 80% at 1 year and 64% at 5 years; after SC, it was 72% at 1 year and 37% at 5 years (log-rank P = .01). During the median follow-up of 21.5 months (interquartile range, 2.4-61 months), an endoleak after SC was found in the 38.3% of the cases; sac growth was recorded in the 27.7% of SC patients. CONCLUSIONS: SC has an early benefit over LOC in terms of reduced postoperative complications but has a significantly inferior mid-term survival. The high rates of persistent and/or recurrent endoleaks reduce SC durability.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Endovascular Procedures/adverse effects , Humans , Postoperative Complications , Reoperation/adverse effects , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
15.
Acta Biomed ; 92(2): e2021046, 2021 05 12.
Article in English | MEDLINE | ID: mdl-33988179

ABSTRACT

Objectives Type Ia endoleak (EL) after endovascular abdominal aortic repair (EVAR) may be misdiagnosed at completion angiography. Intraoperative contrast-enhanced ultrasound (CEUS) may play a role in early detection and immediate treatment of type Ia EL. Methods From January 2017 to April 2018, patients treated with EVAR underwent intraoperative CEUS. After endograft deployment and ballooning, digital subtraction angiography (DSA) and intraoperative CEUS were performed in a blinded fashion. All cases of type Ia EL at DSA or CEUS were considered. Results Type Ia EL detected at intraoperative CEUS and undetected at DSA was defined in 2 patients. The former was solved with intraoperative re-ballooning; in the latter case, a Palmaz stent deployment was required. The resolution of type Ia EL was detected at intraoperative CEUS control and post-operative computed tomography angiography (CTA). In another patient, the DSA detected a type Ia EL, but intraoperative CEUS reveal a type II EL from lumbar arteries. Post-operative CTA confirm the type II EL. Conclusions The reported cases prove the clinical utility of the intraoperative CEUS, permitting the early identification of 2 type Ia EL. In addition, the intraoperative CEUS is useful in case of dubious type Ia EL at DSA, avoiding unnecessary intraoperative adjunctive procedure or post-operative CTA.


Subject(s)
Aortic Aneurysm, Abdominal , Endovascular Procedures , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Contrast Media , Endoleak/diagnostic imaging , Endoleak/etiology , Humans , Treatment Outcome
16.
Ann Vasc Surg ; 74: 526.e13-526.e23, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33838235

ABSTRACT

Persistent sciatic artery (PSA) is a rare congenital anatomic variant of the lower limb vascular system with highly variable presentations. The management of lower limb ischemia due to PSA disease is not specifically recommended in guidelines, and surgical by-pass is usually the most described treatment. We reported a case of a 46-year-old patient with bilateral PSA and right chronic limb-threatening ischemia due to PSA occlusion at the PSA-popliteal junction which was successfully treated with percutaneous transluminal balloon angioplasty. In addition to this case report, a systematic review of the literature regarding the endovascular management of PSA stenosis and occlusion was conducted.


Subject(s)
Angioplasty, Balloon , Arterial Occlusive Diseases/therapy , Lower Extremity/blood supply , Vascular Malformations , Adult , Aged , Aged, 80 and over , Angioplasty, Balloon/instrumentation , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/physiopathology , Female , Humans , Male , Middle Aged , Treatment Outcome , Vascular Malformations/diagnostic imaging , Vascular Malformations/physiopathology , Vascular Patency
17.
Ann Vasc Surg ; 73: 585-588, 2021 May.
Article in English | MEDLINE | ID: mdl-33556523

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has proven over the years to be a viable alternative to open surgery. A rare but severe complication is represented by the valve migration. We report a case of TAVI complication due to the loss of the prosthetic valve in the abdominal aorta treated by endovascular approach. METHODS: An 88-year-old patient with severe aortic valve stenosis, symptomatic for dyspnea was proposed for a TAVI because considered at high risk for surgery. During the TAVI procedure, the undeployed device (Edwards SAPIEN 3 - Edwards Lifesciences, Irvine, CA, USA) detached from its delivery system. Several attempts to withdraw the valve fluctuating in the aorta into its supporting system were performed without success. An emergency endovascular treatment was promptly planned to obtain the exclusion from the flow of the embolized valve. Under local anaesthesia, through the percutaneous femoral access already present, a tube aortic endograft (EndurantTM II, Medtronic, Santa Rosa, CA; ETTF2828C70EE) was successfully introduced and deployed in the infrarenal aorta without any related complications. The embolized valve was completely covered by the endgraft and thus fixed to the aortic wall. The first postoperative computer tomography angiography (CTA) confirmed the correct placement of the endograft, the exclusion of the valve from the flow and the patency of the great vessels. No perioperative or postoperative complications were recorded. The patient was discharged on the ninth postoperative day with the indication to a new attempt of TAVI, through transapical access. CONCLUSIONS: In case of intraprocedural loss of an undeplyed valve during TAVI, the valve fixing through endograft deployment in infrarenal aorta is a possible solution.


Subject(s)
Aorta, Abdominal , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Foreign-Body Migration/etiology , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aorta, Abdominal/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Endovascular Procedures , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/therapy , Humans , Male , Severity of Illness Index , Treatment Outcome
18.
J Viral Hepat ; 28(3): 558-568, 2021 03.
Article in English | MEDLINE | ID: mdl-33306247

ABSTRACT

In routine clinical practice, hepatitis C virus-infected patients can prematurely discontinue the prescribed regimen for several reasons. The aim of our study was to investigate sustained virological response (SVR12) rates in patients who prematurely discontinued directly acting antiviral (DAA) regimens and to assess the shortest effective duration of DAA able to lead to SVR12. We retrospectively collected the SVR rates of patients, registered in the NAVIGATORE-Lombardia Network database from January 2015, who discontinued DAAs before the predefined end of treatment. Overall, we included 365 patients, males were the majority (213, 58.4%), mean age was 60.5 years, and 53 (14.5%) patients were HIV-co-infected. Liver cirrhosis was observed in 251 (68.8%) subjects, and the most represented genotypes were 1b (n = 168, 46%) and 3 (n = 59, 16.2%). DAA was discontinued a median of 1 (IQR 1-4) weeks before the predefined EOT, with 164 (44.9%) patients stopping DAAs at least 2 weeks before the planned schedule. In patients with F0-F3 liver fibrosis, lower rates of SVR12 were observed in patients treated for <4 weeks: 50% (n = 2/4) vs. 99.1% (n = 109/110) for ≥4 weeks, p = 0.003. In patients with liver cirrhosis, lower rates of SVR12 were observed in patients treated <8 weeks: 83.3% (n = 25/30) vs. 94.6% (n = 209/221) for ≥8 weeks, p = 0.038. Despite premature discontinuation of DAA, high SVR12 rates were observed in a real-life setting for treatment lasting at least 4 weeks in patients with liver fibrosis F0-F3 and 8 weeks in those with liver cirrhosis. On this basis, feasibility of reducing DAA treatment duration should be explored in randomized clinical trials.


Subject(s)
Hepatitis C, Chronic , Hepatitis C , Antiviral Agents/therapeutic use , Hepacivirus/genetics , Hepatitis C/drug therapy , Hepatitis C, Chronic/drug therapy , Humans , Male , Middle Aged , Retrospective Studies , Sustained Virologic Response , Treatment Outcome
19.
Vasc Endovascular Surg ; 55(3): 254-264, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33353481

ABSTRACT

OBJECTIVES: The purpose of this paper is to report the different modalities for the treatment of isolated internal iliac artery aneurysms (IIIAA), as well as their outcomes. METHODS: We performed a systematic review of the literature (database searched: PubMed, Web of Science, Scopus, Cochrane Library; last search: April 2020). We included articles reporting on the outcomes for IIIAA interventions comprising at least 5 patients. Studies were included when presenting extractable outcome data regarding intraoperative and/or early results. We performed meta-analyses of proportions for different outcomes, using random effects model. RESULTS: Thirteen non-randomized studies were included (192 patients with 202 IIIAA). IIIAA were symptomatic in the 18.1% (95%CI 9.3-26.9; I2 54.46%, P = .019). Estimated mean IIIAA diameter was 46.28 mm (95%CI 39.72-52.85; I2 88.85%, P < .001). Open repair was performed in 21/202 cases. Endovascular treatments were: embolization (81/181), embolization and hypogastric artery coverage (79/181), hypogastric artery coverage by stent-grafting (15/181), stent-grafting in the hypogastric artery (6/181). Overall estimated technical success (TS) rate was 91.6% (95% CI 86.8-95.5; I2 45.82%, P = .031). TS rate was 94.5% for open surgery (95%CI 85.3-100; I2 0%, P = .907), and 89.7% for endovascular repair (95%CI 83.8-95.6; I2 55.43%, P = .006). Estimated overall 30-day mortality was 3.1% (95%CI 0.8-5.4; I2 0%, P = .969). Mortality rates after open surgery and endovascular repair were 8.2% (95%CI 3.4-19.8; I2 0%, P = .545) and 2.8% (95%CI 0.5-5.1; I2 0%, P = .994), respectively. Estimated mean follow-up was 32.63 months (95%CI 21.74-43.53; I2 94.45%, P < .001). During this timeframe, IIIAA exclusion was preserved in 92.8% of the patients (95%CI 89.3-96.2; I2 0%, P = .797). Buttock claudication occurred in 13.9% of the patients (95%CI 8.7-19.2; I2 0%, P = .622). CONCLUSIONS: IIIAA are frequently large, and symptomatic at presentation. Several treatments are proposed in literature, open and endovascular, both with good results. The endovascular treatment is the preferred method of treatment in literature, since it offers good short- to mid-term results and low early mortality. Buttock claudication after hypogastric artery exclusion is a common complication.


Subject(s)
Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Iliac Aneurysm/surgery , Aged , Aged, 80 and over , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/mortality , Male , Middle Aged , Postoperative Complications/etiology , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...