Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
J Matern Fetal Neonatal Med ; 36(1): 2197099, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37031967

ABSTRACT

We report the case of a massive fetal cardiac rhabdomyoma recently occurred at our clinic. A woman at 23 weeks of gestational age was referred to our center for a fetal cardiac echogenic mass of 26 mm detected at the second-trimester screening ultrasound. During pregnancy, though, the mass progressively increased its dimensions until reaching 48 mm in diameter at 37 weeks of gestation. Fetal echoencephalography and brain magnetic resonance did not show any further fetal anomalies, but molecular genetic testing at amniocentesis revealed a heterozygotic missense variant of gene TSC2 associated with Tuberous Sclerosis. The mass was therefore most likely preferable to a single large rhabdomyoma of gradually increasing dimensions. The baby was delivered at term with a cesarean section. Because of the rhabdomyoma remarkable size and newborn ECG electrical alterations, postnatal therapies with Flecainide and Everolimus were started. Everolimus treatment led to a significant and progressive reduction in the cardiac mass volume. This case, therefore, shows the efficacy of what seems to be a promising treatment in pediatric patients with large rhabdomyomas.Learning points:Rhabdomyomas may present with different features: most often they appear as multiple masses along the interventricular sept, but they may also appear as a single large thoracic mass.When a rhabdomyoma is suspected, genetic counseling is recommended.Both before and after birth, a multidisciplinary approach is useful to choose the appropriate therapy for the newborn.mTOR inhibitors therapies look like promising therapeutic approaches to stimulate the involution of rhabdomyomas.


Subject(s)
Heart Neoplasms , Rhabdomyoma , Tuberous Sclerosis , Infant , Infant, Newborn , Humans , Pregnancy , Child , Female , Rhabdomyoma/diagnostic imaging , Rhabdomyoma/genetics , Rhabdomyoma/complications , Everolimus , Cesarean Section , Ultrasonography , Tuberous Sclerosis/complications , Tuberous Sclerosis/diagnostic imaging , Tuberous Sclerosis/genetics , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/therapy , Heart Neoplasms/complications
2.
J Matern Fetal Neonatal Med ; 35(25): 6090-6096, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33823732

ABSTRACT

BACKGROUND: Speckle tracking technology has been applied to assess ventricular deformation throughout the cardiac cycle. An electronic four dimensional probe that allows rapid acquisition of electronic spatio-temporal image correlation volumes (eSTIC) has been recently introduced. OBJECTIVES: The aim of our study was to investigate whether e-STIC acquisition improves deformation analyses reproducibility. STUDY DESIGN: We recruited fetuses between 20 and 40 weeks of gestation. We obtained a 2D video clip and an e-STIC volume of a four-chamber view. We focused on left ventricular global strain (LV-GS) and left ventricular ejection fraction (LV-FE). Intraobserver, interobserver and intermethod agreement were assessed by means of intraclass correlation coefficient (ICC) and illustrated by Bland-Altman plots. Systematic differences between measurements were assessed using a paired t-test. RESULTS: The mean difference between LV-GS values obtained with e-STIC and 2D analysis was -0.10 (95% CI -2.28, 2.08). No systematic differences were found between the two techniques for LV-GS values (p-value = .927). The mean difference between LV-FE values obtained with e-STIC and 2D analysis was 7.55 (95% CI 4.16, 10.95; p-value <.001). The inter-rater reliability of LV-GS was moderate-to-substantial for both e-STIC and 2D. The inter-rater reliability of LV-FE obtained via e-STIC was superior to that obtained via 2D analysis. The intra-rater reliability of LV-GS obtained with e-STIC was superior to that obtained with 2D analysis (ICC 0.857; 95% IC 0.761-0.917). The intra-rater reliability of LV-FE obtained via e-STIC was superior to that obtained via 2D analysis (ICC 0.647; IC 0.51-0.783). CONCLUSIONS: e-STIC seems to be a better technique than 2D analysis for intra-rater reliability of LV-GS. 4D acquisition might improve intrinsic limitations of speckle tracking echocardiography.


Subject(s)
Echocardiography, Three-Dimensional , Ventricular Function, Left , Female , Humans , Stroke Volume , Reproducibility of Results , Echocardiography/methods , Fetus , Electronics , Echocardiography, Three-Dimensional/methods
3.
J Matern Fetal Neonatal Med ; 35(22): 4299-4305, 2022 Nov.
Article in English | MEDLINE | ID: mdl-33203263

ABSTRACT

INTRODUCTION: Coarctation of the aorta (CoA) is common and can lead to neonatal emergency. Despite its burden, antenatal detection of this condition remains inaccurate. OBJECTIVE: To evaluate the diagnostic performance of fetal echocardiography and to design a scoring system for risk stratification of CoA in suspected cases. DESIGN: A retrospective cohort study. SETTING: S. Orsola Hospital, Bologna, Italy. POPULATION: About 140 fetuses referred for suspected CoA to our tertiary center in a 9-year period. METHODS: The following parameters were systematically obtained at fetal echocardiography: ventricular disproportion, great vessels asymmetry, transverse aortic arch hypoplasia, flow turbulence, and Z-scores of the ascending aorta and of the aortic isthmus. Associated anomalies were recorded, if present. When CoA was not confirmed at birth, neonates were followed up for 12 months to identify also a tardive onset of this condition. MAIN OUTCOME MEASURES: The primary outcome was the presence of COA after birth. RESULTS: 108 fetuses were eligible for the purpose of the study. CoA was confirmed postnatally in 55 neonates (50.9%). Arch hypoplasia yielded the highest correlation with CoA. The affected neonates presented also significantly lower Z scores of the ascending aorta and of the aortic isthmus. Earlier gestational age at referral was positively correlated with neonatal CoA. An odds ratio-based multiparametric model was designed to build a scoring system (AUC 0.89). CONCLUSION: In our cohort, no single ultrasound parameter was sufficiently accurate to predict postnatal CoA. The scoring system permitted a better identification of the affected fetuses.


Subject(s)
Aortic Coarctation , Aorta , Aortic Coarctation/diagnostic imaging , Echocardiography , Female , Humans , Infant, Newborn , Pregnancy , Retrospective Studies , Ultrasonography, Prenatal
4.
Am J Obstet Gynecol MFM ; 3(5): 100379, 2021 09.
Article in English | MEDLINE | ID: mdl-33965655

ABSTRACT

BACKGROUND: Hypoxia caused by inadequate intracardiac mixing owing to a restrictive foramen ovale is a potentially life-threatening complication in neonates with dextro-transposition of the great arteries. An urgent balloon atrial septostomy is a procedure of choice in such cases, but dependent on the availability of a 24-hour interventional cardiology facility. The prenatal identification of predictors for an urgent balloon atrial septostomy at birth would help in optimizing the management of these neonates, minimizing the risk of hypoxic damage. OBJECTIVE: This study aimed to predict with prenatal echocardiography the need of urgent balloon atrial septostomy in neonates with dextro-transposition of the great arteries. STUDY DESIGN: This was a retrospective cohort study of patients with a prenatal diagnosis of transposition of the great arteries that were delivered in our center between 2010 and 2019, for whom fetal ultrasound echocardiograms obtained at less than 3 weeks before delivery were available. The following parameters were systematically obtained at fetal echocardiography: size and appearance of the foramen ovale, septum primum excursion (foramen ovale flap angle at the maximal excursion), diameters of the atria, and size of the ductus arteriosus. Balloon atrial septostomy was defined as urgent if performed within 12 hours from birth in neonates with restrictive foramen ovale. Neonatal follow-up was obtained through medical records analysis. RESULTS: From November 2007 to April 2019, 160 fetuses with complete transposition of the great arteries were referred to our echocardiography laboratory and 60 of these were included in the analysis; 27 underwent urgent balloon atrial septostomy, 11 elective balloon atrial septostomy, and 22 no balloon atrial septostomy. The size of the foramen ovale was the best predictor of an urgent balloon atrial septostomy. A measurement of >6.5 mm had a sensitivity of 100% and a false positive rate of 45%. CONCLUSION: Fetal echocardiography predicts the need of an urgent balloon atrial septostomy in fetuses with dextro-transposition of the great arteries although with a limited precision. In our experience, a measurement of the foramen ovale within 3 weeks of delivery had the greatest accuracy.


Subject(s)
Foramen Ovale , Transposition of Great Vessels , Arteries , Female , Foramen Ovale/diagnostic imaging , Humans , Infant, Newborn , Pregnancy , Retrospective Studies , Transposition of Great Vessels/diagnostic imaging , Ultrasonography, Prenatal
5.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 23-26, 2021 12.
Article in Italian | MEDLINE | ID: mdl-35343487

ABSTRACT

We present a case of prenatal diagnosis of critical congenital aortic valve stenosis with progressive systolic left ventricular failure. An ultrasound-guided balloon aortic valvuloplasty was performed at 28 weeks of gestational age because of left ventricular dysfunction associated with signs of fetal heart failure. There were no significant post-procedural complications and the pregnancy was carried to term with elective cesarean section at 38 weeks of gestational age. At birth, an echocardiogram showed severe aortic valve stenosis with global hypokinesia of the left ventricle. Therefore a percutaneous balloon aortic valvuloplasty was repeated through transseptal approach with prompt improvement of the antegrade aortic flow and of the left ventricular systolic function. The baby is currently 2 months old and he is doing fine.


Subject(s)
Aortic Valve Stenosis , Cardiac Surgical Procedures , Ventricular Dysfunction, Left , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Catheterization , Cesarean Section , Female , Humans , Infant , Infant, Newborn , Male , Pregnancy , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/therapy
6.
Am J Obstet Gynecol MFM ; 2(4): 100207, 2020 11.
Article in English | MEDLINE | ID: mdl-33345922

ABSTRACT

BACKGROUND: The prenatal diagnosis of an isolated congenital heart defect is a matter of concern for parents. The decision of whether to terminate the pregnancy according to the different types of congenital heart defects has not been investigated yet. OBJECTIVE: This study aimed to evaluate the frequency of voluntary termination of pregnancy after the prenatal diagnosis of a congenital heart defect in a tertiary care center. STUDY DESIGN: This was a retrospective study of patients who were referred to our center from January 2013 to December 2019, underwent fetal echocardiography, and were counseled by a perinatologist and a pediatric cardiologist. The following data were collected: prenatal diagnosis, including genetic testing; gestational age at diagnosis; and outcome of pregnancy. The diagnoses were stratified retrospectively according to the type of congenital heart defect and its severity (low complexity, moderate complexity, and high complexity) by a perinatologist and a pediatric cardiologist. RESULTS: Of 704 women who received a diagnosis of fetal congenital heart defect, 531 (75.4%) were seen before 23 weeks' gestation, which is the upper limit imposed for the termination of pregnancy by the Italian legislation. Congenital heart defects were apparently isolated in 437 of 531 cases (82.3%). Overall, 108 of 531 patients (20.3%) requested a termination of pregnancy. The rate of termination of pregnancy was found to vary according to the severity of congenital heart defects: low complexity, 0%; moderate complexity, 12.1%, and high complexity, 33.2% (P<.001). The presence or absence of associated anomalies or the ethnicity of the couples was not found to have an influence on women's decisions. CONCLUSION: In our population, the decision to terminate a pregnancy after the diagnosis of a fetal congenital heart defect is influenced by the surgical complexity of the congenital heart defect itself. However, most patients, including those with the most severe forms of congenital heart defect, decided to continue the pregnancy.


Subject(s)
Fetal Diseases , Heart Defects, Congenital , Child , Female , Heart Defects, Congenital/diagnosis , Humans , Pregnancy , Prenatal Diagnosis , Retrospective Studies , Ultrasonography, Prenatal
7.
Mol Diagn Ther ; 21(6): 653-661, 2017 12.
Article in English | MEDLINE | ID: mdl-28744745

ABSTRACT

OBJECTIVE: Maternal plasma is a source of circulating placental nucleic acids. This study was designed to detect aberrantly expressed placental mRNA genes circulating in the maternal plasma of pregnancies affected with fetal conotruncal anomalies (CNTRA) and left-ventricular outflow tract (LVOT) obstruction in the second trimester of pregnancy. METHODS: This was a retrospective monocentric study conducted from 1 Jan 2016 to 31 Dec 2016. NanoString technology was used to identify aberrantly expressed genes, comparing 36 women carrying a fetus with CNTRA or LVOT obstruction to 42 controls at 19-24 weeks of gestation. The genes with differential expression were subsequently tested using real-time polymerase chain reaction. Linear discriminant analysis was used to combine all the mRNA species with discriminant ability for CNTRA and LVOT obstruction. A multivariable receiver operating characteristic (ROC) curve having the estimated discriminant score as an explanatory variable was generated for the two affected groups versus controls. RESULTS: Three genes with differential expression, namely MAPK1, IQGAP1 and Visfatin were found. The ROC curves yielded detection rates of 60 and 62.5% at a false-positive rate of 5% for CNTRA and LVOT, respectively. CONCLUSIONS: These data suggested that molecular screening of CNTRA and LVOT obstruction in the second trimester is feasible. Prospective studies are needed to test the discriminant ability of these genes and to calculate the predictive positive value in the general population.


Subject(s)
Heart Defects, Congenital/diagnosis , Heart Ventricles/abnormalities , RNA, Messenger/blood , Ventricular Outflow Obstruction/diagnosis , Adult , Biomarkers/blood , Case-Control Studies , Cytokines/genetics , Electrocardiography , Female , Gene Expression Regulation, Developmental , Heart Defects, Congenital/genetics , Humans , Middle Aged , Mitogen-Activated Protein Kinase 1/genetics , Nicotinamide Phosphoribosyltransferase/genetics , Pregnancy , Pregnancy Trimester, Second , ROC Curve , Retrospective Studies , Ventricular Outflow Obstruction/genetics , ras GTPase-Activating Proteins/genetics
8.
Fetal Diagn Ther ; 41(1): 1-7, 2017.
Article in English | MEDLINE | ID: mdl-27174184

ABSTRACT

OBJECTIVES: To analyze the role of middle cerebral artery (MCA) peak systolic velocity (PSV) in the prediction of severe fetomaternal hemorrhage (FMH) and to compare it with standard biophysical assessment. DATA SOURCES: Retrospective review of cases of FMH seen in our unit and systematic review of the literature. RESULTS: We followed the MOOSE guidelines to review the literature. From 838 articles, 16 were selected. In total, 35 women, including 3 cases from our center and 32 obtained from the literature search were included. Diagnosis of FMH was always confirmed by laboratory tests. Patients were seen at 31 ± 5 weeks' gestation (range 16-39) and the most frequent indication for referral was decreased perception of fetal movements. Cardiotocography (CTG) upon admission was sinusoidal in 18 cases, nonreactive in 6, decelerative in 2 and tachycardic in one. MCA-PSV was abnormal in all cases but one. There were 2 perinatal deaths. The mean hemoglobin concentration at birth or at intrauterine transfusion was 4.8 ± 1.9 g/dl. DISCUSSION: The most accurate predictor of FMH was fetal MCA-PSV. CTG was always abnormal but the pattern was frequently nonspecific. We suggest including fetal cerebral Doppler in the evaluation of patients with decreased fetal movements, particularly in those cases with ambiguous results of biophysical testing.


Subject(s)
Fetomaternal Transfusion/diagnostic imaging , Adult , Blood Transfusion, Intrauterine , Female , Flow Cytometry , Humans , Pregnancy , Retrospective Studies , Ultrasonography, Doppler , Ultrasonography, Prenatal
9.
Prenat Diagn ; 36(8): 738-43, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27257136

ABSTRACT

OBJECTIVE: To verify the hypothesis that aberrant placental mRNA genes related to cardiogenesis can be detected in maternal plasma at the second trimester of pregnancy. METHODS: NanoString technology was used to identify aberrant genes, comparing 39 women carrying a fetus with a congenital heart defect (CHD) to 31 controls at 19-24 weeks of gestation. The genes with differential expression were subsequently tested using real time polymerase chain reaction. Linear discriminant analysis (LDA) was used to combine all the mRNA species with discriminant ability for CHD. A multivariable receiver operating characteristic (ROC) curve having the estimated discriminant score as an explanatory variable was generated. RESULTS: Six genes with differential expression, namely FALZ, PAPP-A, PRKACB, SAV1, STK4 and TNXB2, were found. The ROC curve yielded a detection rate of 66.7% at a false positive rate of 10%. A higher discriminant score (>75(th) centile) was reached for 14 CHD cases (82.4%) and only 1 control (5.8%). Two cases (11.8%) of heart rhythm disorders also yielded a discriminant score value >75(th) centile. CONCLUSION: These data represent a step forward in the screening of CHDs. Additional studies are needed to detect more mRNAs with discriminant ability and to move the first trimester screening.


Subject(s)
Heart Defects, Congenital/blood , RNA, Messenger/blood , Antigens, Nuclear/genetics , Case-Control Studies , Cell Cycle Proteins/genetics , Cyclic AMP-Dependent Protein Kinase Catalytic Subunits/genetics , Discriminant Analysis , Female , Heart Defects, Congenital/genetics , Humans , Intracellular Signaling Peptides and Proteins , Linear Models , Multivariate Analysis , Nerve Tissue Proteins/genetics , Pregnancy , Pregnancy Trimester, Second , Pregnancy-Associated Plasma Protein-A/genetics , Prenatal Diagnosis , Protein Serine-Threonine Kinases/genetics , ROC Curve , Real-Time Polymerase Chain Reaction , Retrospective Studies , Tenascin/genetics , Transcription Factors/genetics
10.
J Cardiovasc Med (Hagerstown) ; 16(8): 568-75, 2015 Aug.
Article in English | MEDLINE | ID: mdl-24933199

ABSTRACT

OBJECTIVES: To analyse the outcomes of fetuses with congenital heart disease between 2000 and 2005 in comparison to a previous multicentre study regarding the period 1983-1996. PARTICIPANTS AND METHODS: Data of seven centres were prospectively collected, the inclusion criteria being a confirmed fetal diagnosis after birth or at autopsy and a known follow-up, for at least 6 months after birth. Data of 649 fetuses, median age at diagnosis 24 weeks' gestation (15-37), 340/649 (52.4%) diagnosed before 24 weeks, were analysed. RESULTS: Sixty seven and 59 cases had chromosomal or extracardiac anomalies (10.3 and 9.1%). Termination of pregnancy was chosen in 21.6% of cases versus 28.9% in the previous study, being significantly lower in cases with early diagnosis (P <0.001). Out of 509 fetuses continuing pregnancy, 23 died in utero (4.5%) and 110 (21.1%) postnatally, versus 43% in the previous study (P <0.0017). Total surgical/postprocedure death occurred in 20.6% (59/287 infants) versus 37% previously (P <0.003), 67 infants being premature and 35 with associated chromosomal or extracardiac anomalies. The current overall mortality rate was higher in cases with chromosomal or extracardiac anomalies (59.5 and 51.35%, respectively, whereas it was 20.1% in isolated congenital heart disease). Overall current survival was 376 of 509 (73.9%) versus 45% in the previous study (P <0.0001). CONCLUSION: Our data show a reduced overall and surgical mortality, with respect to our previous study, resulting from resulting from an improved perinatal management and treatment of affected fetuses in the more recent era.


Subject(s)
Fetal Mortality/trends , Fetus/abnormalities , Heart Defects, Congenital/mortality , Heart Defects, Congenital/surgery , Perinatal Mortality/trends , Female , Humans , Infant, Newborn , Italy , Perinatal Care/trends , Pregnancy , Prospective Studies , Ultrasonography, Prenatal
11.
Prenat Diagn ; 30(3): 229-34, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20063376

ABSTRACT

OBJECTIVE: To investigate whether a significantly aberrant expression of circulating placental mRNA genes related with cardiogenesis can be detected at the second trimester of pregnancy. METHODS: The study was performed in two stages. First stage (development model group): match of 14 placental tissues at delivery of fetuses with congenital heart disease versus 20 controls. Second stage (validation model group): mRNA amplification of abnormal expressed genes in maternal blood samples from 26 women bearing a fetus with a congenital heart disease matched with 28 controls. RESULTS: We identified four functional categories of genes possibly involved in abnormal heart development: cardiac morphogenesis: tenascin, thioredoxin, salvador homolog 1 protein; extracellular matrix (ECM) and valvular tissue biosynthesis; placental-associated plasma protein, collagen, type I, alpha 2, fibulin-1, heparanase, procollagen-proline, 2-oxoglutarate 4-dioxygenase, alpha polypeptide II, Jumonji, AT rich interactive domain 1B RBP2-like; normal contractile activity: actinin, alpha 4, fascin homolog 1, actin-bundling protein; and congestive heart failure. CONCLUSION: Altered placental genetic expression was found at term delivery in affected fetuses. The aberration was also confirmed in maternal blood at the second trimester of women bearing a fetus with congenital heart disease. Sensitivity for the most aberrant genes ranged between 42% and 95% at a false positive rate (FPR) of 10%.


Subject(s)
Fetal Diseases/blood , Genetic Testing/methods , Heart Defects, Congenital/blood , Molecular Diagnostic Techniques/methods , Placenta/metabolism , RNA, Messenger/blood , Biomarkers/blood , Female , Fetal Diseases/genetics , Gene Expression Profiling , Heart Defects, Congenital/genetics , Humans , Maternal-Fetal Exchange , Oligonucleotide Array Sequence Analysis , Placenta/chemistry , Predictive Value of Tests , Pregnancy , Pregnancy Trimester, Second/blood , Retrospective Studies
12.
Prenat Diagn ; 29(4): 389-95, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19333960

ABSTRACT

Although no precise figures are available, many congenital brain lesions arise from intrauterine disruption, frequently due to obstetric complications. The most common entities include intracranial hemorrhage, ischemic lesions, thrombosis of venous vessels and infections. Accurate prenatal diagnosis is possible in many of these cases. However, the findings may be subtle, particularly in the early stage of the disruptive process. Identification of these conditions requires therefore specific expertise, the combination of fetal neurosonography and magnetic resonance, and frequently there is a need for serial examinations. Targeted diagnostic imaging should be offered to obstetric patients with conditions predisposing to prenatal cerebral insults.


Subject(s)
Brain Diseases/diagnosis , Brain Diseases/embryology , Fetal Diseases/diagnosis , Gestational Age , Prenatal Diagnosis , Blood Vessels/abnormalities , Blood Vessels/embryology , Brain/blood supply , Brain/embryology , Brain Diseases/etiology , Brain Neoplasms/diagnosis , Brain Neoplasms/embryology , Cytomegalovirus Infections/diagnosis , Cytomegalovirus Infections/embryology , Female , Humans , Hypoxia-Ischemia, Brain/diagnosis , Hypoxia-Ischemia, Brain/embryology , Infections/diagnosis , Infections/embryology , Intracranial Hemorrhages/diagnosis , Intracranial Hemorrhages/embryology , Pregnancy , Venous Thrombosis/diagnosis , Venous Thrombosis/embryology
13.
Pediatr Transplant ; 13(5): 650-3, 2009 Aug.
Article in English | MEDLINE | ID: mdl-18992068

ABSTRACT

Whereas it is well known that idiopathic HCM can present in newborns and infants, little information is available on HT in this very young age group. We report a series of 17 infants with idiopathic HCM, including two neonates with rapidly progressive severe HF for whom HT was necessary. When HF manifests in a newborn/infant with idiopathic HCM and extreme cavity size reduction, the possibility of a rapidly progressive clinical course should be anticipated and HT may become the only available therapeutic solution.


Subject(s)
Cardiomyopathy, Hypertrophic/therapy , Heart Transplantation/methods , Echocardiography/methods , Female , Heart Ventricles/pathology , Humans , Hyperplasia , Infant , Infant, Newborn , Male , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...