Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Obstet Gynaecol Can ; 46(3): 102276, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37944819

ABSTRACT

OBJECTIVES: The Omicron variant of the SARS-CoV-2 virus is described as more contagious than previous variants. We sought to assess risk to health care workers (HCWs) caring for patients with COVID-19 in surgical/obstetrical settings, and the perception of risk among this group. METHODS: From January to April 2022, reverse transcription polymerase chain reaction was used to detect the presence of SARS-CoV-2 viral ribonucleic acid in patient, environmental (floor, equipment, passive air) samples, and HCWs' masks (inside surface) during urgent surgery or obstetrical delivery for patients with SARS-CoV-2 infection. The primary outcome was the proportion of HCWs' masks testing positive. Results were compared with our previous cross-sectional study involving obstetrical/surgical patients with earlier variants (2020-2021). HCWs completed a risk perception electronic questionnaire. RESULTS: Eleven patients were included: 3 vaginal births and 8 surgeries. In total, 5/108 samples (5%) tested positive (SARS-CoV-2 Omicron) viral ribonucleic acid: 2/5 endotracheal tubes, 1/22 floor samples, 1/4 patient masks, and 1 nasal probe. No samples from the HCWs' masks (0/35), surgical equipment (0/10), and air (0/11) tested positive. No significant differences were found between the Omicron and 2020/21 patient groups' positivity rates (Mann-Whitney U test, P = 0.838) or the level of viral load from the nasopharyngeal swabs (P = 0.405). Nurses had a higher risk perception than physicians (P = 0.038). CONCLUSION: No significant difference in contamination rates was found between SARS-CoV-2 Omicron BA.1 and previous variants in surgical/obstetrical settings. This is reassuring as no HCW mask was positive and no HCW tested positive for COVID-19 post-exposure.


Subject(s)
COVID-19 , Pregnancy Complications, Infectious , Female , Pregnancy , Humans , SARS-CoV-2 , Health Personnel , RNA , Patient Care
2.
CMAJ Open ; 10(2): E450-E459, 2022.
Article in English | MEDLINE | ID: mdl-35609928

ABSTRACT

BACKGROUND: The exposure risks to front-line health care workers caring for patients with SARS-CoV-2 infection undergoing surgery or obstetric delivery are unclear, and an understanding of sample types that may harbour virus is important for evaluating risk. We sought to determine whether SARS-CoV-2 viral RNA from patients with SARS-CoV-2 infection undergoing surgery or obstetric delivery was present in the peritoneal cavity of male and female patients, in the female reproductive tract, in the environment of the surgery or delivery suite (surgical instruments or equipment used, air or floors), and inside the masks of the attending health care workers. METHODS: We conducted a cross-sectional study from November 2020 to May 2021 at 2 tertiary academic Toronto hospitals, during urgent surgeries or obstetric deliveries for patients with SARS-CoV-2 infection. The presence of SARS-CoV-2 viral RNA in patient, environmental and air samples was identified by real-time reverse transcription polymerase chain reaction (RT-PCR). Air samples were collected using both active and passive sampling techniques. The primary outcome was the proportion of health care workers' masks positive for SARS-CoV-2 RNA. We included adult patients with positive RT-PCR nasal swab undergoing obstetric delivery or urgent surgery (from across all surgical specialties). RESULTS: A total of 32 patients (age 20-88 yr) were included. Nine patients had obstetric deliveries (6 cesarean deliveries), and 23 patients (14 male) required urgent surgery from the orthopedic or trauma, general surgery, burn, plastic surgery, cardiac surgery, neurosurgery, vascular surgery, gastroenterology and gynecologic oncology divisions. SARS-CoV-2 RNA was detected in 20 of 332 (6%) patient and environmental samples collected: 4 of 24 (17%) patient samples, 5 of 60 (8%) floor samples, 1 of 54 (2%) air samples, 10 of 23 (43%) surgical instrument or equipment samples, 0 of 24 cautery filter samples and 0 of 143 (95% confidence interval 0-0.026) inner surface of mask samples. INTERPRETATION: During the study period of November 2020 to May 2021, we found evidence of SARS-CoV-2 RNA in a small but important number of samples obtained in the surgical and obstetric operative environment. The finding of no detectable virus inside the masks worn by the health care teams would suggest a low risk of infection for health care workers using appropriate personal protective equipment.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Aged , Aged, 80 and over , COVID-19/diagnosis , COVID-19/epidemiology , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Operating Rooms , RNA, Viral/genetics , SARS-CoV-2/genetics , Young Adult
3.
Sci Rep ; 11(1): 5565, 2021 03 10.
Article in English | MEDLINE | ID: mdl-33692375

ABSTRACT

Coagulation Factor XIa (FXIa) is an emerging target for antithrombotic agent development. The M358R variant of the serpin alpha-1 antitrypsin (AAT) inhibits both FXIa and other proteases. Our aim was to enhance the specificity of AAT M358R for FXIa. We randomized two AAT M358R phage display libraries at reactive centre loop positions P13-P8 and P7-P3 and biopanned them with FXIa. A bacterial expression library randomized at P2'-P3' was also probed. Resulting novel variants were expressed as recombinant proteins in E. coli and their kinetics of FXIa inhibition determined. The most potent FXIa-inhibitory motifs were: P13-P8, HASTGQ; P7-P3, CLEVE; and P2-P3', PRSTE (respectively, novel residues bolded). Selectivity for FXIa over thrombin was increased up to 34-fold versus AAT M358R for these single motif variants. Combining CLEVE and PRSTE motifs in AAT-RC increased FXIa selectivity for thrombin, factors XIIa, Xa, activated protein C, and kallikrein by 279-, 143-, 63-, 58-, and 36-fold, respectively, versus AAT M358R. AAT-RC lengthened human plasma clotting times less than AAT M358R. AAT-RC rapidly and selectively inhibits FXIa and is worthy of testing in vivo. AAT specificity can be focused on one target protease by selection in phage and bacterial systems coupled with combinatorial mutagenesis.


Subject(s)
Factor XIa/chemistry , Gene Expression , Mutagenesis , Peptide Library , alpha 1-Antitrypsin/chemistry , Escherichia coli/chemistry , Escherichia coli/genetics , Escherichia coli/metabolism , Humans , Recombinant Proteins/biosynthesis , Recombinant Proteins/chemistry , Recombinant Proteins/genetics , alpha 1-Antitrypsin/biosynthesis , alpha 1-Antitrypsin/genetics
4.
J Minim Invasive Gynecol ; 27(7): 1524-1530, 2020.
Article in English | MEDLINE | ID: mdl-31927043

ABSTRACT

STUDY OBJECTIVE: To determine the quality and reliability of the top 20 internet search results for laser treatment of stress urinary incontinence (SUI). DESIGN: Review of 20 websites. SETTING: N/A. PATIENTS: None. INTERVENTIONS: An internet search with the most popular search engine, Google, was undertaken to identify the top 20 websites for laser treatment of SUI. The DISCERN instrument, Journal of the American Medical Association (JAMA) benchmarks, and Health on the Net Foundation Code of Conduct certification, which are standardized, validated tools for the analysis of website quality, credibility, and transparency, were used independently by 7 healthcare workers. The readability of the information was assessed by a single reviewer using the Flesch-Kincaid Grade Level and Automated Readability Index. The intraclass correlation coefficient was calculated to document the reliability among website assessors. MEASUREMENTS AND MAIN RESULTS: Of the 20 websites reviewed, 15 were created by private clinics, 2 by online newspaper or newsletter sites, and 3 by laser medical device manufacturers. None of the websites met all of the JAMA criteria: 1 had attained authorship, 1 had clear attribution, none had adequate disclosure, and 2 achieved currency. None of the websites took part in the Health on the Net Foundation Code of Conduct certification program. The mean DISCERN score (to determine the quality of websites) was 40 (out of 80), with the lowest average scores within the DISCERN tool primarily associated with clarity around sources of information, website bias, posting dates, risks of treatment, and shared treatment decision-making. The intraclass correlation coefficient was calculated for the DISCERN tool (0.72; 95% confidence interval, 0.48-0.87) and JAMA benchmarks (0.85; 95% confidence interval, 0.73-0.93). The mean Flesch-Kincaid Grade Level was 13.2 (±3.1) and the Automated Readability Index scores ranged from 7.6 to 22.8 (mean 13.5 ± 3.5). CONCLUSION: There is a lack of good quality, reliable, and unbiased information available to patients on laser treatment of SUI on the most commonly searched websites. Information is presented at a reading level that is above that of the average reader, which may indicate that patients will have trouble comprehending the information.


Subject(s)
Access to Information , Data Accuracy , Internet , Laser Therapy , Urinary Incontinence/surgery , Benchmarking , Comprehension , Humans , Internet/standards , Laser Therapy/psychology , Reproducibility of Results , Retrospective Studies
5.
Methods Mol Biol ; 1826: 41-64, 2018.
Article in English | MEDLINE | ID: mdl-30194592

ABSTRACT

Phage display is a protein engineering approach that involves construction of libraries of variant proteins displayed on the surface of bacteriophage as capsid fusion proteins and their screening for binding and inhibitory function through the use of bait proteins. Recently, we adapted a commercially available T7 phage display system to create phage-displayed serpin libraries hypervariable in up to five positions in their reactive center loop (RCL). The RCL is a key determinant in serpin specificity, the relationship between the structure of a given serpin and which target proteinase(s) it inhibits. In this chapter, we describe protocols to assess the feasibility of this method for different serpin/proteinase combinations and share experience with this technology gathered in the course of studying two serpins and multiple proteinases with this powerful iterative screening approach.


Subject(s)
Bacteriophage T7 , Peptide Library , Serine Proteases , Serpins , Animals , Bacteriophage T7/chemistry , Bacteriophage T7/genetics , Humans , Protein Structure, Secondary , Serine Proteases/chemistry , Serine Proteases/genetics , Serpins/chemistry , Serpins/genetics
6.
Transfusion ; 57(3): 661-673, 2017 03.
Article in English | MEDLINE | ID: mdl-28019031

ABSTRACT

BACKGROUND: Pathogen reduction treatment using riboflavin and ultraviolet light illumination (Mirasol) effectively reduces the risk of transfusion-transmitted infections. This treatment is currently licensed for only platelets and plasma products, while its application to whole blood (WB) to generate pathogen-inactivated red blood cells (RBCs) is under development. RBC storage lesion, constituting numerous morphologic and biochemical changes, influences RBC quality and limits shelf life. Stored RBCs further show enhanced susceptibility to RBC programmed cell death (eryptosis) characterized by increased cytosolic Ca2+ -provoked membrane phosphatidylserine (PS) externalization. STUDY DESIGN AND METHODS: Using a "pool-and-split" approach, we examined multiple variables of RBC storage lesion and eryptosis in RBC units, derived from Mirasol-treated or untreated WB, after 4 to 42 days of storage, under blood bank conditions. RESULTS: In comparison to untreated RBC units, Mirasol treatment significantly altered membrane microvesiculation, supernatant hemoglobin, osmotic fragility, and intracellular adenosine triphosphate levels but did not influence membrane CD47 expression and 2,3-diphosphoglycerate levels. Mirasol-treated RBCs showed significantly higher PS exposure after 42, but not after not more than 21, days of storage, which was accompanied by enhanced cytosolic Ca2+ activity, ceramide abundance, and oxidative stress, but not p38 kinase activation. Mirasol treatment significantly augmented PS exposure, Ca2+ entry, and protein kinase C activation after energy depletion, a pathophysiologic cell stressor. Mirasol-treated RBCs were, however, more resistant to cell shrinkage. CONCLUSIONS: Prolonged storage of Mirasol-treated RBCs significantly increases the proportion of eryptotic RBCs, while even short-term storage enhances the susceptibility of RBCs to stress-induced eryptosis, which could reduce posttransfusion RBC recovery in patients.


Subject(s)
Blood Preservation , Disinfection , Eryptosis , Erythrocytes/metabolism , Riboflavin , Ultraviolet Rays/adverse effects , Eryptosis/drug effects , Eryptosis/radiation effects , Erythrocytes/pathology , Female , Humans , Male , Riboflavin/adverse effects , Riboflavin/pharmacology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...