1.
J Aging Stud ; 69: 101230, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38834253

ABSTRACT

Meaningful work is related to the motivation to continue to work in older ages and later retirement. This qualitative study addresses calls for further research on the meaning of working for older workers using the Interpretative Phenomenological Analysis approach to explore in-depth the dimensions underlying the subjective experience of meaningful work among 27 nurses and nursing assistants aged 55-75 years. The findings show that work was perceived as a primary source of: (1) personal identity (2) purpose and contribution, (3) competence and accomplishment, (4) social contacts and belongingness, (5) activity, routines and purposeful use of time, and (6) economic security and freedom. These qualitative findings may be applied in interventions aiming to encourage extended working lives in key welfare occupations, which are facing significant staff shortages.


Subject(s)
Nurses , Nursing Assistants , Qualitative Research , Humans , Sweden , Middle Aged , Female , Male , Aged , Nursing Assistants/psychology , Nurses/psychology , Job Satisfaction
2.
Med Phys ; 51(7): 5059-5069, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38197459

ABSTRACT

BACKGROUND: Inorganic scintillation detectors (ISDs) are promising for in vivo dosimetry in brachytherapy (BT). ISDs have fast response, providing time resolved dose rate information, and high sensitivity, attributed to high atomic numbers. However, the conversion of the detector signal to absorbed dose-to-water is highly dependent on the energy spectrum of the incident radiation. This dependence is comprised of absorbed dose energy dependence, obtainable with Monte Carlo (MC) simulation, and the absorbed dose-to-signal conversion efficiency or intrinsic energy dependence requiring measurements. Studies have indicated negligible intrinsic energy dependence of ZnSe:O-based ISDs in Ir-192 BT. A full characterization has not been performed earlier. PURPOSE: This study characterizes the intrinsic energy dependence of ZnSe:O-based ISDs for kV X-ray radiation qualities, with energies relevant for BT. METHODS: Three point-like ISDs made from fiber-coupled cuboid ZnSe:O-based scintillators were calibrated at the Swedish National Metrology Laboratory for ionizing radiation. The calibration was done in terms of air kerma free-in-air, K air ${K}_{{\mathrm{air}}}$ , in 13 X-ray radiation qualities, Q $Q$ , from 25 to 300 kVp (CCRI 25-250 kV and ISO 4037 N-series), and in terms of absorbed dose to water, D w ${D}_{\mathrm{w}}$ , in a Co-60 beam, Q 0 ${Q}_0$ . The mean absorbed dose to the ISDs, relative to K air ${K}_{{\mathrm{air}}}$ and D w ${D}_{\mathrm{w}}$ , were obtained with the MC code TOPAS (Geant4) using X-ray spectra obtained with SpekPy software and laboratory filtration data and a generic Co-60 source. The intrinsic energy dependence was determined as a function of effective photon energy, E e f f ${E}_{eff}$ , (relative to Co-60). The angular dependence of the ISD signal was measured in a 25 kVp (0.20 mm Al HVL) and 135 kVp beam (0.48 mm Cu HVL), by rotating the ISDs 180° around the fiber's longitudinal axis (perpendicular to the beam). A full 360° was not performed due to setup limitations. The impact of detector design was quantified with MC simulation. RESULTS: Above 30 keV E e f f ${E}_{eff}$ the intrinsic energy dependence varied with less than 5 ± 4% from unity for all detectors (with the uncertainty expressed as the mean of all expanded measurement uncertainties for individual E e f f ${E}_{eff}$ above 30 keV, k = 2). Below 30 keV, it decreased with up to 17% and inter-detector variations of 13% were observed, likely due to differences in detector geometry not captured by the simulations using nominal geometry. In the 25 kVp radiation quality, the ISD signal varied with 24% over a ∼45° rotation. For 135 kVp, the corresponding variation was below 3%. Assuming a 0.05 mm thicker layer of reflective paint around the sensitive volume changed the absorbed dose with 6.3% at the lowest E e f f ${E}_{eff}$ , and with less than 2% at higher energies. CONCLUSION: The study suggests that the ISDs have an intrinsic energy dependence relative to Co-60 lower than 5 ± 4% in radiation qualities with E e f f ${E}_{eff}\ $ > 30 keV. Therefore, they could in principle be calibrated in a Co-60 beam quality and transferred to such radiation qualities with correction factors determined only by the absorbed dose energy dependence obtained from MC simulations. This encourages exploration of the ISDs' applications in intensity modulated BT with Yb-169 or other novel intermediate energy isotopes.


Subject(s)
Brachytherapy , Monte Carlo Method , Scintillation Counting , Brachytherapy/instrumentation , Brachytherapy/methods , Scintillation Counting/instrumentation , Calibration
3.
Nanomedicine ; 47: 102621, 2023 01.
Article in English | MEDLINE | ID: mdl-36283571

ABSTRACT

Rectal cancer is a common cancer, with presently a 5-year survival of 67 %. Treatment is based on tumor stage, but current staging methods, such as magnetic resonance imaging (MRI) or ultrasound, are limited in the ability to correctly stage the disease. Magnetomotive ultrasound is a developing modality that has a potential to improve rectal cancer staging. Magnetic nanoparticles are set in motion by an external magnetic field, and the resulting motion signature is detected by ultrasound. Here, we report on magnetomotive images of magnetic nanoparticles in human tissue, using a prototype system where a rotating permanent magnet provides the varying magnetic field, and an ultrasound transducer array encircling the magnet, detects the induced motion. Prior to surgery, a patient with a low rectal tumor was injected at three sites close to the tumor with magnetic nanoparticles. Postsurgical magnetomotive ultrasound scanning revealed the three injection sites, with no obvious artefactual signals. A phantom study showed detection of nanoparticles beyond 40 mm, where 30 mm is the expected maximum distance to mesorectal lymph nodes. Magnetomotive ultrasound image of iron oxide nanoparticles in human tissue. Prior to surgery a patient was injected with nanoparticles, and the excised tissue specimen was imaged with a prototype magnetomotive ultrasound system. The three colored areas overlaid on the standard B-mode greyscale image, correspond to the three injection sites.


Subject(s)
Neoplasms , Humans
4.
Scand J Trauma Resusc Emerg Med ; 30(1): 35, 2022 May 12.
Article in English | MEDLINE | ID: mdl-35551626

ABSTRACT

BACKGROUND: Previous studies have shown variations in management routines for children with traumatic brain injury (TBI) in Sweden. It is unknown if this management has changed after the publication of the Scandinavian Neurotrauma Committee guidelines in 2016 (SNC16). Also, knowledge of current practice routines may guide development of an efficient implementation strategy for the guidelines. The aim of this study is therefore to describe current management routines in paediatric TBI on a hospital/organizational level in Sweden. Secondary aims are to analyse differences in management over time, to assess the current dissemination status of the SNC16 guideline and to analyse possible variations between hospitals. METHODS: This is a sequential, cross-sectional, structured survey in five sections, covering initial management routines for paediatric TBI in Sweden. Respondents, with profound knowledge of local management routines and recommendations, were identified for all Swedish hospitals with an emergency department managing children (age 0-17 year) via phone/mail before distribution of the survey. Responses were collected via an on-line survey system during June 2020-March 2021. Data are presented as descriptive statistics and comparisons were made using Fisher exact test, when applicable. RESULTS: 71 of the 76 identified hospitals managed patients with TBI of all ages and 66 responded (response rate 93%). 56 of these managed children and were selected for further analysis. 76% (42/55) of hospitals have an established guideline to aid in clinical decision making. Children with TBI are predominately managed by inexperienced doctors (84%; 47/56), primarily from non-paediatric specialities (75%; 42/56). Most hospitals (75%; 42/56) have the possibility to admit and observe children with TBI of varying degrees and almost all centres have complete access to neuroradiology (96%; 54/56). In larger hospitals, it was more common for nurses to discharge patients without doctor assessment when compared to smaller hospitals (6/9 vs. 9/47; p < 0.001). Presence of established guidelines (14/51 vs. 42/55; p < 0.001) and written observation routines (16/51 vs. 29/42; p < 0.001) in hospitals have increased significantly since 2006. CONCLUSIONS: TBI management routines for children in Sweden still vary, with some differences occurring over time. Use of established guidelines, written observation routines and information for patients/guardians have all improved. These results form a baseline for current management and may also aid in guideline implementation.


Subject(s)
Brain Injuries, Traumatic , Adolescent , Aged , Brain Injuries, Traumatic/epidemiology , Brain Injuries, Traumatic/therapy , Child , Child, Preschool , Cross-Sectional Studies , Emergency Service, Hospital , Humans , Infant , Infant, Newborn , Patient Discharge , Sweden/epidemiology
5.
J Aging Stud ; 60: 100994, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35248310

ABSTRACT

In many countries, eldercare workers are approaching retirement. To remain attractive to older and experienced workers, organizations need to understand how employees nearing retirement think about and experience their work situation. This qualitative study investigated how older nursing assistants within residential care for older people experienced aging at work, their psychosocial work environment, and their late-career planning. Semi-structured interviews with eight nursing assistants (aged 55-61 years) in Sweden were analyzed using an Interpretative Phenomenological Analysis approach. The results show that the psychosocial work environment was perceived as stressful and considered a long-term health risk, and that (future) health and work ability were key factors determining nursing assistants' late-career planning. Moreover, personal resources and social support from colleagues seemed protective against job demands. Aspects considered in late-career planning also included personal finances and meaningfulness of work. While these findings may be sample-specific, they still provide insights into the experiences of an important occupational group. This means that the findings can be useful for organizations aiming at promoting successful and sustainable aging-in-workplace and encouraging extended working lives.


Subject(s)
Nursing Assistants , Retirement , Aged , Aging , Humans , Qualitative Research , Workplace/psychology
6.
Acta Otolaryngol ; 142(1): 61-66, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34970944

ABSTRACT

BACKGROUND: Universal newborn hearing screening (UNHS) contributes to the early diagnosis of hearing loss. However, not all permanent pediatric hearing impairments can be identified by UNHS. AIMS/OBJECTIVE: To investigate children who have successfully passed the UNHS, but have later-onset hearing loss at an early stage. METHODS: UNHS of children, was reviewed retrospectively from databases at Karolinska University Hospital, Sweden. Gender, age, the reason for contact, the first contact and the most recent audiogram, the hearing diagnosis, the degree of hearing loss when they were enrolled in hearing rehabilitation, and the hearing aids they used were analysed. RESULTS: 63 children who had passed the UNHS at birth and were diagnosed with a hearing impairment at a later stage were included in the study. The average age was 3.3 and 3.9 years old when the children were diagnosed and were finally enrolled in the hearing habilitation, respectively. The reasons for diagnostic evaluation of a suspected hearing loss at present study are preschool hearing tests at the Child Health Care Centres, parents suspect, and/or delayed speech and language development. CONCLUSIONS AND SIGNIFICANCE: Our findings suggest that a passed UNHS does not exclude a future delayed onset of hearing loss, particularly in children with risk factors.


Subject(s)
Early Diagnosis , Hearing Loss/diagnosis , Hearing Tests/methods , Neonatal Screening/methods , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies , Risk Factors
7.
Med Phys ; 47(3): 1268-1279, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31880809

ABSTRACT

PURPOSE: An important characteristic of radiation dosimetry detectors is their energy response which consists of absorbed-dose and intrinsic energy responses. The former can be characterized using Monte Carlo (MC) simulations, whereas the latter (i.e., detector signal per absorbed dose to detector) is extracted from experimental data. Such a characterization is especially relevant when detectors are used in nonrelative measurements at a beam quality that differs from the calibration beam quality. Having in mind the possible application of synthetic diamond detectors (microDiamond PTW 60019, Freiburg, Germany) for nonrelative dosimetry of low-energy brachytherapy (BT) beams, we determined their intrinsic and absorbed-dose energy responses in 25-250 kV beams relative to a 60 Co beam, which is usually the reference beam quality for detector calibration in radiotherapy. MATERIAL AND METHODS: Three microDiamond detectors and, for comparison, two silicon diodes (PTW 60017) were calibrated in terms of air-kerma free in air in six x-ray beam qualities (from 25 to 250 kV) and in terms of absorbed dose to water in a 60 Co beam at the national metrology laboratory in Sweden. The PENELOPE/penEasy MC radiation transport code was used to calculate the absorbed-dose energy response of the detectors (modeled based on blueprints) relative to air and water depending on calibration conditions. The MC results were used to extract the relative intrinsic energy response of the detectors from the overall energy response. Measurements using an independent setup with a single ophthalmic BEBIG I25.S16 125 I BT seed (effective photon energy of 28 keV) were used as a qualitative check of the extracted intrinsic energy response correction factors. Additionally, the impact of the thickness of the active volume as well as the presence of extra-cameral components on the absorbed-dose energy response of a microDiamond detector was studied using MC simulations. RESULTS: The relative intrinsic energy response of the microDiamond detectors was higher by a factor of 2 in 25 and 50 kV beams compared to the 60 Co beam. The variation in the relative intrinsic energy response of silicon diodes was within 10% over the investigated photon energy range. The use of relative intrinsic energy response correction factors improved the agreement among the absorbed dose to water values determined using microDiamond detectors and silicon diodes, as well as with the TG-43 formalism-based calculations for the 125 I seed. MC study of microDiamond detector design features provided a possible explanation for inter-detector response variation at low-energy photon beams by differences in the effective thickness of the active volume. CONCLUSIONS: MicroDiamond detectors had a non-negligible variation in the relative intrinsic energy response (factor of 2) which was comparable to that in the absorbed-dose energy response relative to water at low-energy photon beams. Silicon diodes, in contrast, had an absorbed-dose energy dependence on photon energy that varied by a factor of 6, whereas the intrinsic energy dependence on beam quality was within 10%. It is important to decouple these two responses for a full characterization of detector energy response especially when the user and reference beam qualities differ significantly, and MC alone is not enough.


Subject(s)
Diamond , Phantoms, Imaging , Photons/therapeutic use , Radiometry/instrumentation , Calibration , Iodine Radioisotopes/therapeutic use , Monte Carlo Method
8.
Sci Rep ; 9(1): 13803, 2019 09 24.
Article in English | MEDLINE | ID: mdl-31551503

ABSTRACT

Chronic intestinal injury after pelvic radiotherapy affects countless cancer survivors worldwide. A comprehensive understanding of the long-term injury dynamics is prevented in available animal models. With linear accelerators that are used to treat cancer in patients, we irradiated a small volume encompassing the colorectum in mice with four fractions of 8 Gy per fraction. We then determined the long-term dynamics of mucosal injury, repair, and the duration of inflammation. We show that crypt fission, not cell proliferation, is the main long-term mechanism for rescuing crypt density after irradiation, and provides a potentially wide window for clinical interventions. Persisting macrophage aggregations indicate a chronic mucosal inflammation. A better understanding as to how crypt fission is triggered and why it fails to repair fully the mucosa may help restore bowel health after pelvic radiotherapy. Moreover, anti-inflammatory interventions, even if implemented long after completed radiotherapy, could promote bowel health in pelvic cancer survivors.


Subject(s)
Intestinal Mucosa/radiation effects , Pelvis/radiation effects , Radiotherapy/adverse effects , Animals , Cell Proliferation/radiation effects , Colon/radiation effects , Disease Models, Animal , Humans , Inflammation/physiopathology , Macrophages/radiation effects , Male , Mice , Mice, Inbred C57BL
9.
Phys Med ; 53: 129-136, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30241747

ABSTRACT

PURPOSE: To determine out-of-field doses produced in proton pencil beam scanning (PBS) therapy using Monte Carlo simulations and to estimate the associated risk of radiation-induced second cancer from a brain tumor treatment. METHODS: Simulations of out-of-field absorbed doses were performed with MCNP6 and benchmarked against measurements with tissue-equivalent proportional counters (TEPC) for three irradiation setups: two irradiations of a water phantom using proton energies of 78-147 MeV and 177-223 MeV, and one brain tumor irradiation of a whole-body phantom. Out-of-field absorbed and equivalent doses to organs in a whole-body phantom following a brain tumor treatment were subsequently simulated and used to estimate the risk of radiation-induced cancer. Additionally, the contribution of absorbed dose originating from radiation produced in the nozzle was calculated from simulations. RESULTS: Out-of-field absorbed doses to the TEPC ranged from 0.4 to 135 µGy/Gy. The average deviation between simulations and measurements of the water phantom irradiations was about 17%. The absorbed dose contribution from radiation produced in the nozzle ranged between 0 and 70% of the total dose; the contribution was however small in absolute terms. The absorbed and equivalent doses to the organs ranged between 0.2 and 60 µGy/Gy and 0.5-151 µSv/Gy. The estimated lifetime risk of radiation-induced second cancer was approximately 0.01%. CONCLUSIONS: The agreement of out-of-field absorbed doses between measurements and simulations was good given the sources of uncertainties. Calculations of out-of-field organ doses following a brain tumor treatment indicated that proton PBS therapy of brain tumors is associated with a low risk of radiation-induced cancer.


Subject(s)
Brain Neoplasms/radiotherapy , Monte Carlo Method , Neoplasms, Radiation-Induced/etiology , Proton Therapy/adverse effects , Radiation Dosage , Humans , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Risk
10.
Phys Med ; 47: 9-15, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29609824

ABSTRACT

Comparisons of national standard of air kerma for conventional and mammographic diagnostic X-ray radiation qualities were conducted by the IAEA. Eleven secondary standards dosimetry laboratories provided calibration data for Exradin A3 and Radcal RC6M transfer ionization chambers circulated. Each comparison result expressed as the ratio of the participant and IAEA calibration coefficient were within the acceptance limit of ±2.5%. From the 67 results of 11 participants and 10 available beam qualities, the comparison result was within its standard uncertainty in 63 cases, and within the expanded (k = 2) uncertainty in four cases. Detailed calibration uncertainty budgets from participant laboratories are presented. The relative standard calibration uncertainty of each participant was in the range of 0.5-1.3%. These results indicate that the calibration related uncertainty component is reasonable low for a clinical measurement. In addition to the calibration coefficient, other corrections should be applied for clinical measurement to achieve the recommended accuracy.


Subject(s)
Air , International Agencies , Radiometry/instrumentation , Radiometry/standards , Reference Standards
11.
Am J Physiol Gastrointest Liver Physiol ; 313(5): G456-G466, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28729245

ABSTRACT

A deeper understanding of the radiation-induced pathophysiological processes that develop in the gut is imperative to prevent, alleviate, or eliminate cancer survivorship diseases after radiotherapy to the pelvic area. Most rodent models of high-dose gastrointestinal radiation injury are limited by high mortality. We therefore established a model that allows for the delivering of radiation in fractions at high doses while maintaining long-term survival. Adult male C57/BL6 mice were exposed to small-field irradiation, restricted to 1.5 cm of the colorectum using a linear accelerator. Each mouse received 6 or 8 Gy, two times daily in 12-h intervals in two, three, or four fractions. Acute cell death was examined at 4.5 h postirradiation and histological changes at 6 wk postirradiation. Another group was given four fractions of 8 Gy and followed over time for development of visible symptoms. Irradiation caused immediate cell death, mainly limited to the colorectum. At 6 wk postirradiation, several crypts displayed signs of radiation-induced degeneration. The degenerating crypts were seen alongside crypts that appeared perfectly healthy. Crypt survival was reduced after the fourth fraction regardless of dose, whereas the number of macrophages increased. Angiogenesis was induced, likely as a compensatory mechanism for hypoxia. Four months postirradiation, mice began to show radiation-induced symptoms, and histological examination revealed an extensive crypt loss and fibrosis. Our model is uniquely suitable for studying the long-term trajectory and underlying mechanisms of radiation-induced gastrointestinal injury.NEW & NOTEWORTHY A novel mouse model for studying the long-term trajectory of radiation-induced gut injury. The method allows for the use of high doses and multiple fractions, with minor impact on animal health for at least 3 mo. Crypt loss and a slow progression of fibrosis is observed. Crypt degeneration is a process restricted to isolated crypts. Crypt degeneration is presented as a convenient proxy endpoint for long-term radiation-induced gut injury.


Subject(s)
Colorectal Neoplasms , Disease Models, Animal , Gastrointestinal Tract , Mice , Neoplasms, Radiation-Induced/pathology , Radiation Injuries, Experimental/pathology , Animals , Cell Survival , Colorectal Neoplasms/etiology , Colorectal Neoplasms/pathology , Dose Fractionation, Radiation , Gastrointestinal Tract/injuries , Gastrointestinal Tract/pathology , Gastrointestinal Tract/radiation effects , Pelvis/radiation effects , Radiotherapy/adverse effects , Radiotherapy/methods
12.
Phys Med ; 32(1): 42-51, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26508013

ABSTRACT

A comparison of calibration results and procedures in terms of air kerma length product, PKL, and air kerma, K, was conducted between eight dosimetry laboratories. A pencil-type ionization chamber (IC), generally used for computed tomography dose measurements, was calibrated according to three calibration methods, while its residual signal and other characteristics (sensitivity profile, active length) were assessed. The results showed that the "partial irradiation method" is the preferred method for the pencil-type IC calibration in terms of PKL and it could be applied by the calibration laboratories successfully. Most of the participating laboratories achieved high level of agreement (>99%) for both dosimetry quantities (PKL and K). Estimated relative standard uncertainties of comparison results vary among laboratories from 0.34% to 2.32% depending on the quantity, beam quality and calibration method applied. Detailed analysis of the assigned uncertainties have been presented and discussed.


Subject(s)
Ions , Laboratories/standards , Radiometry/methods , Tomography, X-Ray Computed/methods , Air , Calibration , Europe , International Cooperation , Models, Statistical , Observer Variation , Radiation Dosage , Reproducibility of Results
13.
Brachytherapy ; 13(4): 420-3, 2014.
Article in English | MEDLINE | ID: mdl-24530343

ABSTRACT

PURPOSE: According to the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism used for dose calculation in brachytherapy treatment planning systems, the absolute level of absorbed dose is determined through coupling with the measurable quantity air-kerma strength or the numerically equal reference air-kerma rate (RAKR). Traceability to established standards is important for accurate dosimetry in laying the ground for reliable comparisons of results and safety in adoption of new treatment protocols. The purpose of this work was to compare the source strength for a high-dose rate (HDR) (192)Ir source as measured using equipment traceable to different standard laboratories in Europe and the United States. METHODS AND MATERIALS: Source strength was determined for one HDR (192)Ir source using four independent systems, all with traceability to different primary or interim standards in the United States and Europe. RESULTS: The measured HDR (192)Ir source strengths varied by 0.8% and differed on average from the vendor value by 0.3%. Measurements with the well chambers were 0.5% ± 0.1% higher than the vendor-provided source strength. Measurements with the Farmer chamber were 0.7% lower than the average well chamber results and 0.2% lower than the vendor-provided source strength. All of these results were less than the reported source calibration uncertainties (k=2) of each measurement system. CONCLUSIONS: In view of the uncertainties in ion chamber calibration factors, the maximum difference in source strength found in this study is small and confirms the consistency between calibration standards in use for HDR (192)Ir brachytherapy.


Subject(s)
Brachytherapy/methods , Iridium Radioisotopes/analysis , Radiopharmaceuticals/analysis , Brachytherapy/standards , Calibration , Europe , Humans , Iridium Radioisotopes/standards , Iridium Radioisotopes/therapeutic use , Radiometry/methods , Radiopharmaceuticals/standards , Radiopharmaceuticals/therapeutic use , Radiotherapy Dosage , United States
14.
Pharm Res ; 30(12): 3225-37, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23771564

ABSTRACT

PURPOSE: To investigate if drug solubility in pharmaceutical excipients used in lipid based formulations (LBFs) can be predicted from physicochemical properties. METHODS: Solubility was measured for 30 structurally diverse drug molecules in soybean oil (SBO, long-chain triglyceride; TGLC), Captex355 (medium-chain triglyceride; TGMC), polysorbate 80 (PS80; surfactant) and PEG400 co-solvent and used as responses during PLS model development. Melting point and calculated molecular descriptors were used as variables and the PLS models were validated with test sets and permutation tests. RESULTS: Solvation capacity of SBO and Captex355 was equal on a mol per mol scale (R (2) = 0.98). A strong correlation was also found between PS80 and PEG400 (R (2) = 0.85), identifying the significant contribution of the ethoxylation for the solvation capacity of PS80. In silico models based on calculated descriptors were successfully developed for drug solubility in SBO (R (2) = 0.81, Q (2) = 0.76) and Captex355 (R (2) = 0.84, Q (2) = 0.80). However, solubility in PS80 and PEG400 were not possible to quantitatively predict from molecular structure. CONCLUSION: Solubility measured in one excipient can be used to predict solubility in another, herein exemplified with TGMC versus TGLC, and PS80 versus PEG400. We also show, for the first time, that solubility in TGMC and TGLC can be predicted from rapidly calculated molecular descriptors.


Subject(s)
Excipients/chemistry , Lipids/chemistry , Pharmaceutical Preparations/chemistry , Computer Simulation , Least-Squares Analysis , Models, Chemical , Polyethylene Glycols/chemistry , Polysorbates/chemistry , Solubility , Solvents/chemistry , Surface-Active Agents/chemistry , Water/chemistry
15.
Nanomedicine ; 9(7): 1048-56, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23639678

ABSTRACT

Nanometer scale surface features on implants and prostheses can potentially be used to enhance osseointegration and may also add further functionalities, such as infection resistance, to the implant. In this study, a nanostructured noble metal coating consisting of palladium, gold and silver, never previously used in bone applications, was applied to machined titanium screws to evaluate osseointegration after 6 and 12 weeks in rabbit tibiae and femurs. Infection resistance was confirmed by in vitro adhesion test. A qualitatively and quantitatively similar in vivo bone response was observed for the coated and uncoated control screws, using histology, histomorphometry and electron microscopy. The bone-implant interface analysis revealed an extensive bone formation and direct bone-implant contact. These results demonstrate that the nanostructured noble metal coating with antimicrobial properties promotes osseointegration and may therefore be used to add extra implant functionality in the form of increased resistance to infection without the use of antibiotics. FROM THE CLINICAL EDITOR: The authors of this paper demonstrate that nanostructured noble metal coating of implants and prostheses used in orthopedic procedures promotes osseointegration and may be used to add extra implant functionality in the form of increased resistance to infection without the use of antibiotics.


Subject(s)
Anti-Infective Agents/pharmacology , Coated Materials, Biocompatible/pharmacology , Metals/pharmacology , Nanostructures/chemistry , Osseointegration/drug effects , Titanium/pharmacology , Animals , Bacterial Adhesion/drug effects , Colony Count, Microbial , Femur/drug effects , Femur/physiology , Femur/ultrastructure , Implants, Experimental , Interferometry , Nanostructures/ultrastructure , Osteogenesis/drug effects , Photoelectron Spectroscopy , Rabbits , Staphylococcus aureus/drug effects , Staphylococcus aureus/growth & development , Surface Properties , Tibia/drug effects , Tibia/physiology , Tibia/ultrastructure
16.
J Virol ; 86(2): 1021-33, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22090118

ABSTRACT

The four Kaposi's sarcoma-associated herpesvirus (KSHV)-encoded interferon (IFN) regulatory factor homologues (vIRF1 to vIRF4) are used to counter innate immune defenses and suppress p53. The vIRF genes are arranged in tandem but differ in function and expression. In KSHV-infected effusion lymphoma lines, K10.5/vIRF3 and K11/vIRF2 mRNAs are readily detected during latency, whereas K9/vIRF1 and K10/vIRF4 mRNAs are upregulated during reactivation. Here we show that the K10/vIRF4 promoter responds to the lytic switch protein RTA in KSHV-infected cells but is essentially unresponsive in uninfected cells. Coexpression of RTA with vIRF4 is sufficient to restore regulation, a property not shared by other vIRFs. The K9/vIRF1 promoter behaves similarly, and production of infectious virus is enhanced by the presence of vIRF4. Synergy requires the DNA-binding domain (DBD) and C-terminal IRF homology regions of vIRF4. Mutations of arginine residues within the putative DNA recognition helix of vIRF4 or the invariant cysteines of the adjacent CxxC motif abolish cooperation with RTA, in the latter case by preventing self-association. The oligomerization and transactivation functions of RTA are also essential for synergy. The K10/vIRF4 promoter contains two transcription start sites (TSSs), and a 105-bp fragment containing the proximal promoter is responsive to vIRF4/RTA. Binding of a cellular factor(s) to this fragment is altered when both viral proteins are present, suggesting a possible mechanism for transcriptional synergy. Reliance on coregulators encoded by either the host or viral genome provides an elegant strategy for expanding the regulatory potential of a master regulator, such as RTA.


Subject(s)
Gene Expression Regulation, Viral , Herpesviridae Infections/virology , Herpesvirus 8, Human/metabolism , Immediate-Early Proteins/metabolism , Interferon Regulatory Factors/metabolism , Promoter Regions, Genetic , Trans-Activators/metabolism , Viral Proteins/metabolism , Amino Acid Motifs , Base Sequence , Binding Sites , Cell Line, Tumor , Herpesvirus 8, Human/chemistry , Herpesvirus 8, Human/genetics , Humans , Immediate-Early Proteins/chemistry , Immediate-Early Proteins/genetics , Interferon Regulatory Factors/chemistry , Interferon Regulatory Factors/genetics , Molecular Sequence Data , Protein Binding , Trans-Activators/chemistry , Trans-Activators/genetics , Transcriptional Activation , Viral Proteins/chemistry , Viral Proteins/genetics
17.
J Virol ; 84(3): 1334-47, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19906914

ABSTRACT

For Kaposi's sarcoma-associated herpesvirus (KSHV; also called human herpesvirus 8 [HHV8]), the switch from latency to active lytic replication requires RTA, the product of open reading frame 50 (ORF50). RTA activates transcription from nearly 40 early and delayed-early viral promoters, mainly through interactions with cellular DNA binding proteins, such as CSL/RBP-Jkappa, Oct-1, C/EBPalpha, and c-Jun. Reliance on cellular coregulators may allow KSHV to adjust its lytic program to suit different cellular contexts or interpret signals from the outside. CSL is a key component of the Notch signaling pathway and is targeted by several viruses. A search with known CSL binding sequences from cellular genes found at least 260 matches in the KSHV genome, many from regions containing known or suspected lytic promoters. Analysis of clustered sites located immediately upstream of ORF70 (thymidylate synthase), ORF19 (tegument protein), and ORF47 (glycoprotein L) uncovered RTA-responsive promoters that were validated using mRNAs isolated from KSHV-infected cells undergoing lytic reactivation. Notably, ORF19 behaves as a true late gene, indicating that RTA regulates all three phases of the lytic program. For each new promoter, the response to RTA was dependent on CSL, and 5 of the 10 candidate sites were shown to bind CSL in vitro. Analysis of individual sites highlighted the importance of a cytosine residue flanking the core CSL binding sequence. These findings broaden the role for CSL in coordinating the KSHV lytic gene expression program and help to define a signature motif for functional CSL sites within the viral genome.


Subject(s)
Gene Expression Regulation, Viral/physiology , Herpesvirus 6, Human/genetics , Immunoglobulin J Recombination Signal Sequence-Binding Protein/physiology , Base Sequence , DNA Primers , Genes, Viral , HeLa Cells , Humans , Immunoglobulin J Recombination Signal Sequence-Binding Protein/metabolism , Molecular Sequence Data , Open Reading Frames , Promoter Regions, Genetic , RNA, Messenger/genetics , Reverse Transcriptase Polymerase Chain Reaction
18.
J Virol ; 84(5): 2318-30, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20032179

ABSTRACT

Kaposi's sarcoma-associated herpesvirus (KSHV)-infected cells express the latency-associated nuclear antigen (LANA) involved in the regulation of host and viral gene expression and maintenance of the KSHV latent episome. Performance of these diverse functions involves a 7-amino-acid chromatin-binding motif (CBM) situated at the amino terminus of LANA that is capable of binding directly to nucleosomes. LANA interacts with additional chromatin components, including methyl-CpG-binding protein 2 (MeCP2). Here, we show that the carboxy-terminal DNA-binding/dimerization domain of LANA provides the principal interaction with MeCP2 but that this association is modulated by the CBM. Both domains are required for LANA to colocalize with MeCP2 at chromocenters, regions of extensive pericentric heterochromatin that can be imaged by fluorescence microscopy. Within MeCP2, the methyl-CpG-binding domain (MBD) is the primary determinant for chromatin localization and acts together with the adjacent repression domains (the transcription repression domain [TRD] and the corepressor-interacting domain [CRID]) to redirect LANA to chromocenters. MeCP2 facilitates repression by LANA bound to the KSHV terminal repeats, a function that requires the MeCP2 C terminus in addition to the MBD and CRID/TRD. LANA and MeCP2 can also cooperate to stimulate transcription of the human E2F1 promoter, which lacks a LANA DNA-binding sequence, but this function requires both the N and C termini of LANA. The ability of LANA to establish multivalent interactions with histones and chromatin-binding proteins such as MeCP2 would enable LANA to direct regulatory complexes to specific chromosomal sites and thereby achieve stable reprogramming of cellular gene expression in latently infected cells.


Subject(s)
Antigens, Viral/metabolism , Herpesvirus 8, Human/metabolism , Methyl-CpG-Binding Protein 2/metabolism , Nuclear Proteins/metabolism , Nucleosomes/metabolism , Amino Acid Sequence , Animals , Antigens, Viral/chemistry , Antigens, Viral/genetics , HeLa Cells , Heterochromatin/metabolism , Humans , Methyl-CpG-Binding Protein 2/chemistry , Methyl-CpG-Binding Protein 2/genetics , Mice , Molecular Sequence Data , NIH 3T3 Cells , Nuclear Proteins/chemistry , Nuclear Proteins/genetics , Protein Isoforms/chemistry , Protein Isoforms/genetics , Protein Isoforms/metabolism , Protein Structure, Tertiary , Recombinant Fusion Proteins/genetics , Recombinant Fusion Proteins/metabolism , Virus Latency/physiology
19.
Appl Opt ; 47(12): 2028-34, 2008 Apr 20.
Article in English | MEDLINE | ID: mdl-18425175

ABSTRACT

We report on a dual-diode laser spectroscopic system for simultaneous detection of two gases. The technique is demonstrated by performing gas measurements on absorbing samples such as an air distance, and on absorbing and scattering porous samples such as human tissue. In the latter it is possible to derive the concentration of one gas by normalizing to a second gas of known concentration. This is possible if the scattering and absorption of the bulk material is equal or similar for the two wavelengths used, resulting in a common effective pathlength. Two pigtailed diode lasers are operated in a wavelength modulation scheme to detect molecular oxygen ~760 nm and water vapor ~935 nm within the tissue optical window (600 nm to 1.3 mum). Different modulation frequencies are used to distinguish between the two wavelengths. No crosstalk can be observed between the gas contents measured in the two gas channels. The system is made compact by using a computer board and performing software-based lock-in detection. The noise floor obtained corresponds to an absorption fraction of approximately 6x10(-5) for both oxygen and water vapor, yielding a minimum detection limit of ~2 mm for both gases in ambient air. The power of the technique is illustrated by the preliminary results of a clinical trial, nonintrusively investigating gas in human sinuses.


Subject(s)
Brain/pathology , Lasers, Semiconductor , Optics and Photonics , Oxygen/chemistry , Spectrophotometry/methods , Water/chemistry , Absorption , Air , Computers , Equipment Design , Humans , Software , Tomography , Tomography, X-Ray Computed
20.
Rev Sci Instrum ; 78(11): 113107, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18052465

ABSTRACT

We present a flexible and compact, digital, lock-in detection system and its use in high-resolution tunable diode laser spectroscopy. The system involves coherent sampling, and is based on the synchronization of two data acquisition cards running on a single standard computer. A software-controlled arbitrary waveform generator is used for laser modulation, and a four-channel analog/digital board records detector signals. Gas spectroscopy is performed in the wavelength modulation regime. The coherently detected signal is averaged a selected number of times before it is stored or analyzed by software-based, lock-in techniques. Multiple harmonics of the modulation signal (1f, 2f, 3f, 4f, etc.) are available in each single data set. The sensitivity is of the order of 10(-5), being limited by interference fringes in the measurement setup. The capabilities of the system are demonstrated by measurements of molecular oxygen in ambient air, as well as dispersed gas in scattering materials, such as plants and human tissue.