Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 93
Filter
1.
Physiol Rep ; 12(12): e16090, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38884325

ABSTRACT

Adverse effects of large artery stiffening are well established in the systemic circulation; stiffening of the proximal pulmonary artery (PPA) and its sequelae are poorly understood. We combined in vivo (n = 6) with ex vivo data from cadavers (n = 8) and organ donors (n = 13), ages 18 to 89, to assess whether aging of the PPA associates with changes in distensibility, biaxial wall strain, wall thickness, vessel diameter, and wall composition. Aging exhibited significant negative associations with distensibility and cyclic biaxial strain of the PPA (p ≤ 0.05), with decreasing circumferential and axial strains of 20% and 7%, respectively, for every 10 years after 50. Distensibility associated directly with diffusion capacity of the lung (R2 = 0.71, p = 0.03). Axial strain associated with right ventricular ejection fraction (R2 = 0.76, p = 0.02). Aging positively associated with length of the PPA (p = 0.004) and increased luminal caliber (p = 0.05) but showed no significant association with mean wall thickness (1.19 mm, p = 0.61) and no significant differences in the proportions of mural elastin and collagen (p = 0.19) between younger (<50 years) and older (>50) ex vivo samples. We conclude that age-related stiffening of the PPA differs from that of the aorta; microstructural remodeling, rather than changes in overall geometry, may explain age-related stiffening.


Subject(s)
Aging , Pulmonary Artery , Vascular Stiffness , Humans , Pulmonary Artery/physiology , Aged , Male , Female , Middle Aged , Adult , Aging/physiology , Aged, 80 and over , Adolescent , Vascular Stiffness/physiology , Young Adult , Elastin/metabolism
2.
Magn Reson Med ; 2024 May 31.
Article in English | MEDLINE | ID: mdl-38817154

ABSTRACT

PURPOSE: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION: Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.

3.
Magn Reson Imaging ; 110: 176-183, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38657714

ABSTRACT

OBJECTIVE: To improve image quality in highly accelerated parameter mapping by incorporating a linear constraint that relates consecutive images. APPROACH: In multi-echo T1 or T2 mapping, scan time is often shortened by acquiring undersampled but complementary measures of k-space at each TE or TI. However, residual undersampling artifacts from the individual images can then degrade the quality of the final parameter maps. In this work, a new reconstruction method, dubbed Constrained Alternating Minimization for Parameter mapping (CAMP), is introduced. This method simultaneously extracts T2 or T1* maps in addition to an image for each TE or TI from accelerated datasets, leveraging the constraints of the decay to improve the reconstructed image quality. The model enforces exponential decay through a linear constraint, resulting in a biconvex objective function that lends itself to alternating minimization. The method was tested in four in vivo volunteer experiments and validated in phantom studies and healthy subjects, using T2 and T1 mapping, with accelerations of up to 12. MAIN RESULTS: CAMP is demonstrated for accelerated radial and Cartesian acquisitions in T2 and T1 mapping. The method is even applied to generate an entire T2 weighted image series from a single TSE dataset, despite the blockwise k-space sampling at each echo time. Experimental undersampled phantom and in vivo results processed with CAMP exhibit reduced artifacts without introducing bias. SIGNIFICANCE: For a wide array of applications, CAMP linearizes the model cost function without sacrificing model accuracy so that the well-conditioned and highly efficient reconstruction algorithm improves the image quality of accelerated parameter maps.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Phantoms, Imaging , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Artifacts , Brain/diagnostic imaging , Reproducibility of Results , Image Enhancement/methods
4.
Am J Physiol Heart Circ Physiol ; 326(5): H1304-H1323, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38517227

ABSTRACT

Peripheral artery disease (PAD) is a common vascular disease that primarily affects the lower limbs and is defined by the constriction or blockage of peripheral arteries and may involve microvascular dysfunction and tissue injury. Patients with diabetes have more prominent disease of microcirculation and develop peripheral neuropathy, autonomic dysfunction, and medial vascular calcification. Early and accurate diagnosis of PAD and disease characterization are essential for personalized management and therapy planning. Magnetic resonance imaging (MRI) provides excellent soft tissue contrast and multiplanar imaging capabilities and is useful as a noninvasive imaging tool in the comprehensive physiological assessment of PAD. This review provides an overview of the current state of the art of MRI in the evaluation and characterization of PAD, including an analysis of the many applicable MR imaging techniques, describing the advantages and disadvantages of each approach. We also present recent developments, future clinical applications, and future MRI directions in assessing PAD. The development of new MR imaging technologies and applications in preclinical models with translation to clinical research holds considerable potential for improving the understanding of the pathophysiology of PAD and clinical applications for improving diagnostic precision, risk stratification, and treatment outcomes in patients with PAD.


Subject(s)
Magnetic Resonance Imaging , Peripheral Arterial Disease , Humans , Peripheral Arterial Disease/physiopathology , Peripheral Arterial Disease/diagnostic imaging , Animals , Predictive Value of Tests , Prognosis
5.
J Cardiovasc Magn Reson ; 26(1): 100998, 2024.
Article in English | MEDLINE | ID: mdl-38237901

ABSTRACT

Cardiac Magnetic Resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR protocols. To this end, the vision of all-in-one and real-time imaging are described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 tackles the "All-in-One" approaches, and Part 2 focuses on the "Real-Time" approaches along with an overall summary of these emerging methods.


Subject(s)
Magnetic Resonance Imaging , Predictive Value of Tests , Humans , Forecasting , Heart Diseases/diagnostic imaging , Heart Diseases/physiopathology , Time Factors , Image Interpretation, Computer-Assisted , Reproducibility of Results , Diffusion of Innovation
6.
J Cardiovasc Magn Reson ; 26(1): 100997, 2024.
Article in English | MEDLINE | ID: mdl-38237900

ABSTRACT

Cardiovascular magnetic resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR. To this end, the vision of each is described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 will tackle the "all-in-one" approaches, and Part 2 the "real-time" approaches along with an overall summary of these emerging methods.


Subject(s)
Cardiovascular Diseases , Magnetic Resonance Imaging , Predictive Value of Tests , Humans , Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/physiopathology , Forecasting , Image Interpretation, Computer-Assisted , Diffusion of Innovation , Time Factors , Reproducibility of Results , Prognosis
7.
Magn Reson Med ; 91(3): 911-925, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37927206

ABSTRACT

PURPOSE: Diastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e'). We aimed to develop an MRI method for simultaneous all-in-one diastolic function evaluation in a single scan by generating a 2D phase-contrast (PC) sequence with balanced steady-state free precession (bSSFP) contrast (PC-SSFP). E and A could then be measured with PC, and e' estimated by valve tracking on the magnitude images, using an established deep learning framework. METHODS: Our PC-SSFP used in-plane flow-encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k-t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC-SSFP was compared to separate balanced SSFP cine and PC-gradient echo acquisitions in phantoms and in 10 healthy subjects. RESULTS: Phantom experiments showed that PC-SSFP measured accurate velocities compared to PC-gradient echo (r = 0.98 for a range of pixel-wise velocities -80 cm/s to 80 cm/s). In subjects, PC-SSFP generated high SNR and myocardium-blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e' (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k-t PCA approach processed the complex difference data and substituted in raw k-space data. With prospective k-t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k-t PCA), yielding a 13% higher e'. CONCLUSION: The proposed PC-SSFP method achieved all-in-one diastolic function evaluation.


Subject(s)
Magnetic Resonance Imaging , Humans , Principal Component Analysis , Retrospective Studies , Prospective Studies , Magnetic Resonance Imaging/methods , Diastole
8.
Int J Cardiovasc Imaging ; 40(1): 107-117, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37857929

ABSTRACT

A relationship between left atrial strain and pressure has been demonstrated in many studies, but not in an atrial fibrillation (AF) cohort. In this work, we hypothesized that elevated left atrial (LA) tissue fibrosis might mediate and confound the LA strain vs. pressure relationship, resulting instead in a relationship between LA fibrosis and stiffness index (mean LA pressure/LA reservoir strain). Sixty-seven patients with AF underwent a standard cardiac MR exam including long-axis cine views (2 and 4-ch) and a free-breathing high resolution three-dimensional late gadolinium enhancement (LGE) of the atrium (N = 41), within 30 days prior to AF ablation, at which procedure invasive mean left atrial pressure (LAP) was measured. LV and LA Volumes, EF, and comprehensive analysis of LA strains (strain and strain rates and strain timings during the atrial reservoir, conduit and active, i.e. active atrial contraction, phases) were measured and LA fibrosis content (LGE (ml)) was assessed from 3D LGE volumes. LA LGE was well correlated to atrial stiffness index overall (R = 0.59, p < 0.001), and among patient subgroups. Pressure was only correlated to maximal LA volume (R = 0.32) and the time to peak reservoir strain rate (R = 0.32) (both p < 0.01), among all functional measurements. LA reservoir strain was strongly correlated with LAEF (R = 0.95, p < 0.001) and LA minimum volume (r = 0.82, p < 0.001). In our AF cohort, pressure is correlated to maximum LA volume and time to peak reservoir strain. LA pressure/ LA reservoir strain, a metric of stiffness, correlates with LA fibrosis (LA LGE), reflecting Hook's Law.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnostic imaging , Contrast Media , Predictive Value of Tests , Gadolinium , Heart Atria , Magnetic Resonance Imaging , Fibrosis
9.
Sci Rep ; 13(1): 19998, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37968574

ABSTRACT

Deuterium metabolic imaging (DMI) is a promising tool for investigating a tumor's biology, and eventually contribute in cancer diagnosis and prognosis. In DMI, [6,6'-2H2]-glucose is taken up and metabolized by different tissues, resulting in the formation of HDO but also in an enhanced formation of [3,3'-2H2]-lactate at the tumor site as a result of the Warburg effect. Recent studies have shown DMI's suitability to highlight pancreatic cancer in murine models by [3,3'-2H2]-lactate formation; an important question is whether DMI can also differentiate between these tumors and pancreatitis. This differentiation is critical, as these two diseases are hard to distinguish today radiologically, but have very different prognoses requiring distinctive treatments. Recent studies have shown the limitations that hyperpolarized MRI faces when trying to distinguish these pancreatic diseases by monitoring the [1-13C1]-pyruvate→[1-13C1]-lactate conversion. In this work, we explore DMI's capability to achieve such differentiation. Initial tests used a multi-echo (ME) SSFP sequence, to identify any metabolic differences between tumor and acute pancreatitis models that had been previously elicited very similar [1-13C1]-pyruvate→[1-13C1]-lactate conversion rates. Although ME-SSFP provides approximately 5 times greater signal-to-noise ratio (SNR) than the standard chemical shift imaging (CSI) experiment used in DMI, no lactate signal was observed in the pancreatitis model. To enhance lactate sensitivity further, we developed a new, weighted-average, CSI-SSFP approach for DMI. Weighted-average CSI-SSFP improved DMI's SNR by another factor of 4 over ME-SSFP-a sensitivity enhancement that sufficed to evidence natural abundance 2H fat in abdominal images, something that had escaped the previous approaches even at ultrahigh (15.2 T) MRI fields. Despite these efforts to enhance DMI's sensitivity, no lactate signal could be detected in acute pancreatitis models (n = 10; [3,3'-2H2]-lactate limit of detection < 100 µM; 15.2 T). This leads to the conclusion that pancreatic tumors and acute pancreatitis may be clearly distinguished by DMI, based on their different abilities to generate deuterated lactate.


Subject(s)
Pancreatic Neoplasms , Pancreatitis , Mice , Humans , Animals , Deuterium , Pancreatitis/diagnostic imaging , Acute Disease , Disease Models, Animal , Magnetic Resonance Imaging/methods , Pancreatic Neoplasms/diagnostic imaging , Lactic Acid/metabolism , Pyruvic Acid/metabolism
10.
NMR Biomed ; 36(11): e4995, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37401393

ABSTRACT

Deuterium metabolic imaging (DMI) is a promising molecular MRI approach, which follows the administration of deuterated substrates and their metabolization. [6,6'-2 H2 ]-glucose for instance is preferentially converted in tumors to [3,3'-2 H2 ]-lactate as a result of the Warburg effect, providing a distinct resonance whose mapping using time-resolved spectroscopic imaging can diagnose cancer. The MR detection of low-concentration metabolites such as lactate, however, is challenging. It has been recently shown that multi-echo balanced steady-state free precession (ME-bSSFP) increases the signal-to-noise ratio (SNR) of these experiments approximately threefold over regular chemical shift imaging; the present study examines how DMI's sensitivity can be increased further by advanced processing methods. Some of these, such as compressed sensing multiplicative denoising and block-matching/3D filtering, can be applied to any spectroscopic/imaging methods. Sensitivity-enhancing approaches were also specifically tailored to ME-bSSFP DMI, by relying on priors related to the resonances' positions and to features of the metabolic kinetics. Two new methods are thus proposed that use these constraints for enhancing the sensitivity of both the spectral images and the metabolic kinetics. The ability of these methods to improve DMI is evidenced in pancreatic cancer studies carried at 15.2 T, where suitable implementations of the proposals imparted eightfold or more SNR improvement over the original ME-bSSFP data, at no informational cost. Comparisons with other propositions in the literature are briefly discussed.

11.
PLoS One ; 18(5): e0286364, 2023.
Article in English | MEDLINE | ID: mdl-37252927

ABSTRACT

BACKGROUND: Cardiac magnetic resonance (CMR) global longitudinal strain and circumferential strain abnormalities have been associated with left ventricular ejection fraction (LVEF) reduction and cardiotoxicity from oncologic therapy. However, few studies have evaluated the associations of strain and cardiovascular outcomes. OBJECTIVES: To assess CMR circumferential and global longitudinal strain (GLS) correlations with cardiovascular outcomes including myocardial infarction, systolic dysfunction, diastolic dysfunction, arrhythmias and valvular disease in breast cancer patients treated with and without anthracyclines and/or trastuzumab therapy. METHODS: Breast cancer patients with a CMR from 2013-2017 at Yale New Haven Hospital were included. Patient co-morbidities, medications, and cardiovascular outcomes were obtained from chart review. Biostatistical analyses, including Pearson correlations, competing risk regression model, and competing risk survival curves comparing the two groups were analyzed. RESULTS: 116 breast cancer with CMRs were included in our analysis to assess differences between Anthracycline/Trastuzumab (AT) (62) treated versus non anthracycline/trastuzumab (NAT) (54) treated patients in terms of imaging characteristics and outcomes. More AT patients 17 (27.4%) developed systolic heart failure compared to the NAT group 6 (10.9%), p = 0.025. Statin use was associated with a significant reduction in future arrhythmias (HR 0.416; 95% CI 0.229-0.755, p = 0.004). In a sub-group of 13 patients that underwent stress CMR, we did not find evidence of microvascular dysfunction by sub-endocardial/sub-epicardial myocardial perfusion index ratio after adjusting for ischemic heart disease. CONCLUSIONS: In our study, CMR detected signs of subclinical cardiotoxicity such as strain abnormalities despite normal LV function and abnormal circumferential strain was associated with adverse cardiovascular outcomes such as valvular disease and systolic heart failure. Thus, CMR is an important tool during and after cancer treatment to identity and prognosticate cancer treatment-related cardiotoxicity.


Subject(s)
Breast Neoplasms , Cardiovascular Diseases , Heart Failure, Systolic , Heart Valve Diseases , Ventricular Dysfunction, Left , Humans , Female , Breast Neoplasms/complications , Breast Neoplasms/drug therapy , Breast Neoplasms/chemically induced , Stroke Volume , Ventricular Function, Left , Cardiotoxicity/etiology , Cardiovascular Diseases/chemically induced , Risk Factors , Arrhythmias, Cardiac/chemically induced , Trastuzumab/adverse effects , Magnetic Resonance Spectroscopy , Magnetic Resonance Imaging, Cine/methods
12.
Res Sq ; 2023 Apr 18.
Article in English | MEDLINE | ID: mdl-37131741

ABSTRACT

Aims: A relationship between left atrial strain and pressure has been demonstrated in many studies, but not in an atrial fibrillation (AF) cohort. In this work, we hypothesized that elevated left atrial (LA) tissue fibrosis might mediate and confound the LA strain vs. pressure relationship, resulting instead in a relationship between LA fibrosis and stiffness index (mean pressure/LA reservoir strain). Methods and Results: Sixty-seven patients with AF underwent a standard cardiac MR exam including long-axis cine views (2 and 4-ch) and a free-breathing high resolution three-dimensional late gadolinium enhancement (LGE) of the atrium (N=41), within 30 days prior to AF ablation, at which procedure invasive mean left atrial pressure (LAP) was measured. LV and LA Volumes, EF, and comprehensive analysis of LA strains (strain and strain rates and strain timings during the atrial reservoir, conduit and active phases) were measured and LA fibrosis content (LGE (ml)) was assessed from 3D LGE volumes. LA LGE was well correlated to atrial stiffness index (LA mean pressure/LA reservoir strain) overall (R=0.59, p<0.001), and among patient subgroups. Pressure was only correlated to maximal LA volume (R=0.32) and the time to peak reservoir strain rate (R=0.32), among all functional measurements. LA reservoir strain was strongly correlated with LAEF (R=0.95, p<0.001) and LA minimum volume (r=0.82, p<0.001). Conclusion: In our AF cohort, pressure is correlated to maximum LA volume and time to peak reservoir strain. LA LGE is a strong marker of stiffness.

13.
Rheumatol Int ; 43(5): 849-858, 2023 05.
Article in English | MEDLINE | ID: mdl-36894756

ABSTRACT

Impaired left-ventricular (LV) and right-ventricular (RV) cardiac magnetic resonance (CMR) strain has been documented in systemic sclerosis (SSc). However, it is unknown whether the CMR strain is predictive of adverse outcomes in SSc. Therefore, we set out to investigate the prognostic value of CMR strain in SSc. Patients with SSc who underwent CMR for clinical indications between 11/2010 and 07/2020 were retrospectively studied. LV and RV strain was evaluated by feature tracking. The association between strain, late gadolinium enhancement (LGE), and survival was evaluated with time to event and Cox-regression analyses. During the study period, 42 patients with SSc (age: 57 ± 14 years, 83% female, 57% limited cutaneous SSc, SSc duration: 7 ± 8 years) underwent CMR. During the median follow-up of 3.6 years, 11 patients died (26%). Compared to surviving patients, patients who died had significantly worse LV GLS (- 8.2 ± 6.2% versus - 12.1 ± 2.9%, p = 0.03), but no difference in LV global radial, circumferential, or RV strain values. Patients within the quartile of most impaired LV GLS (≥ - 12.8%, n = 10) had worse survival when compared to patients with preserved LV GLS (< - 12.8%, n = 32, log-rank p = 0.02), which persisted after controlling for LV cardiac output, LV cardiac index, reduced LV ejection fraction, or presence of LGE. In addition, patients who had both impaired LV GLS and LGE (n = 5) had worse survival than patients with LGE or impaired GLS alone (n = 14) and compared to those without any of these features (n = 17, p = 0.003). In our retrospective cohort of patients with SSc undergoing CMR for clinical indications, LV GLS and LGE were found to be predictive of overall survival.


Subject(s)
Contrast Media , Scleroderma, Systemic , Humans , Female , Adult , Middle Aged , Aged , Male , Retrospective Studies , Magnetic Resonance Imaging, Cine , Global Longitudinal Strain , Gadolinium , Magnetic Resonance Imaging , Ventricular Function, Left , Stroke Volume , Scleroderma, Systemic/complications , Scleroderma, Systemic/diagnostic imaging , Prognosis , Predictive Value of Tests
14.
J Magn Reson Imaging ; 58(3): 782-791, 2023 09.
Article in English | MEDLINE | ID: mdl-36373998

ABSTRACT

BACKGROUND: Balanced steady-state free precession (bSSFP) is important in cardiac MRI but suffers from off-resonance artifacts. The interpretation-limiting artifacts in patients with cardiac implants remain an unsolved issue. PURPOSE: To develop an interleaved radial linear combination bSSFP (lcSSFP) method with partial dephasing (PD) for improved cardiac cine imaging when implanted cardiovascular devices are present. STUDY TYPE: Prospective. PHANTOM AND SUBJECTS: Flow phantom adjacent to a pacemaker and 10 healthy volunteers (mean age ± standard deviation: 31.9 ± 2.9 years, 4 females) with a cardioverter-defibrillator (ICD) positioned extracorporeally at the left chest in the prepectoral region. FIELD STRENGTH/SEQUENCE: A 3-T, 1) Cartesian bSSFP, 2) Cartesian gradient echo (GRE), 3) Cartesian lcSSFP, and 4) radial lcSSFP cine sequences. ASSESSMENT: Flow artifacts mitigation using PD was validated with phantom experiments. Undersampled radial lcSSFP with interleaving across phase-cyclings and cardiac phases (RLC-SSFP), combined with PD, was then employed for achieving improved quality of cine images from left ventricular short-axis view. The image quality in the presence of cardiac devices was qualitatively assessed by three independent raters (1 = worst, 5 = best), regarding five criteria (banding artifacts, streak artifacts, flow artifacts, cavity visibility, and overall image quality). STATISTICAL TESTS: Wilcoxon rank-sum test for the five criteria between Cartesian bSSFP cine and RLC-SSFP with PD. Fleiss kappa test for inter-reader agreement. A P value < 0.05 was considered statistically significant. RESULTS: Based on simulations and phantom experiments, 60 projections per phase cycling and 1/6 PD were chosen. The in vivo experiments demonstrated significantly reduced banding artifacts (4.8 ± 0.4 vs. 2.7 ± 0.7), fewer streak artifacts (3.7 ± 0.6 vs. 2.6 ± 0.7) and flow artifacts (4.4 ± 0.4 vs. 3.7 ± 0.6), therefore improved cavity visibility (4.1 ± 0.4 vs. 2.9 ± 0.9) and overall quality (4.0 ± 0.4 vs. 2.7 ± 0.7). DATA CONCLUSION: RLC-SSFP method with PD may improve cine image quality in subjects with cardiac devices. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Subject(s)
Heart , Magnetic Resonance Imaging, Cine , Female , Humans , Magnetic Resonance Imaging, Cine/methods , Prospective Studies , Heart/diagnostic imaging , Magnetic Resonance Imaging/methods , Heart Ventricles , Artifacts , Reproducibility of Results
15.
JAMA Netw Open ; 5(11): e2239661, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36322090

ABSTRACT

Importance: Contact tracing is a core strategy for preventing the spread of many infectious diseases of public health concern. Better understanding of the outcomes of contact tracing for COVID-19 as well as the operational opportunities and challenges in establishing a program for a jurisdiction as large as New York City (NYC) is important for the evaluation of this strategy. Objective: To describe the establishment, scaling, and maintenance of Trace, NYC's contact tracing program, and share data on outcomes during its first 17 months. Design, Setting, and Participants: This cross-sectional study included people with laboratory test-confirmed and probable COVID-19 and their contacts in NYC between June 1, 2020, and October 31, 2021. Trace launched on June 1, 2020, and had a workforce of 4147 contact tracers, with the majority of the workforce performing their jobs completely remotely. Data were analyzed in March 2022. Main Outcomes and Measures: Number and proportion of persons with COVID-19 and contacts on whom investigations were attempted and completed; timeliness of interviews relative to symptom onset or exposure for symptomatic cases and contacts, respectively. Results: Case investigations were attempted for 941 035 persons. Of those, 840 922 (89.4%) were reached and 711 353 (75.6%) completed an intake interview (women and girls, 358 775 [50.4%]; 60 178 [8.5%] Asian, 110 636 [15.6%] Black, 210 489 [28.3%] Hispanic or Latino, 157 349 [22.1%] White). Interviews were attempted for 1 218 650 contacts. Of those, 904 927 (74.3%) were reached, and 590 333 (48.4%) completed intake (women and girls, 219 261 [37.2%]; 47 403 [8.0%] Asian, 98 916 [16.8%] Black, 177 600 [30.1%] Hispanic or Latino, 116 559 [19.7%] White). Completion rates were consistent over time and resistant to changes related to vaccination as well as isolation and quarantine guidance. Among symptomatic cases, median time from symptom onset to intake completion was 4.7 days; a median 1.4 contacts were identified per case. Median time from contacts' last date of exposure to intake completion was 2.3 days. Among contacts, 30.1% were tested within 14 days of notification. Among cases, 27.8% were known to Trace as contacts. The overall expense for Trace from May 6, 2020, through October 31, 2021, was approximately $600 million. Conclusions and Relevance: Despite the complexity of developing a contact tracing program in a diverse city with a population of over 8 million people, in this case study we were able to identify 1.4 contacts per case and offer resources to safely isolate and quarantine to over 1 million cases and contacts in this study period.


Subject(s)
COVID-19 , Contact Tracing , Female , Humans , COVID-19/epidemiology , COVID-19/prevention & control , New York City/epidemiology , Cross-Sectional Studies , Quarantine
16.
Sex Transm Dis ; 49(11): 771-777, 2022 11 01.
Article in English | MEDLINE | ID: mdl-35948304

ABSTRACT

BACKGROUND: As part of New York State's Ending the Epidemic (EtE) initiative, sexual health clinics (SHCs) in New York City invested in clinic enhancements and expanded their HIV-related services to increase access to HIV prevention interventions and treatment. The objective of this study was to estimate and describe the change in SHC operating costs related to clinic enhancements and expanded patient services implemented as part of the EtE initiative. METHODS: A comprehensive microcosting approach was used to collect retrospective cost information from SHCs, broken down by category and programmatic activity. Cost information was collected from 8 clinics across New York City during two 6-month time periods before (2015) and during (2018-2019) EtE. RESULTS: Eight SHCs reported comprehensive cost data. Costs increased by $800,000 on average per clinic during the 6-month EtE period. The cost per visit at an SHC increased by $120 on average to $381 (ranging from $302 to $464) during the EtE period. Personnel costs accounted for 69.9% of EtE costs, and HIV-related medications accounted for 8.9% of costs. Employment of social workers and patient navigators increased costs by approximately $150,000 on average per clinic. Postexposure prophylaxis was the costliest medication with average expenditures of $103,800 per clinic. CONCLUSIONS: This study demonstrates the key drivers of cost increases when offering enhanced HIV services in SHCs. Documenting the changes in resources necessary to implement these services and their costs can inform other health departments on the viability of offering enhanced HIV services within their own clinics.


Subject(s)
Epidemics , HIV Infections , Sexual Health , HIV Infections/drug therapy , HIV Infections/epidemiology , HIV Infections/prevention & control , Humans , New York City/epidemiology , Retrospective Studies
17.
J Cardiovasc Magn Reson ; 23(1): 137, 2021 12 02.
Article in English | MEDLINE | ID: mdl-34857009

ABSTRACT

BACKGROUND: Mitral annular plane systolic excursion (MAPSE) and left ventricular (LV) early diastolic velocity (e') are key metrics of systolic and diastolic function, but not often measured by cardiovascular magnetic resonance (CMR). Its derivation is possible with manual, precise annotation of the mitral valve (MV) insertion points along the cardiac cycle in both two and four-chamber long-axis cines, but this process is highly time-consuming, laborious, and prone to errors. A fully automated, consistent, fast, and accurate method for MV plane tracking is lacking. In this study, we propose MVnet, a deep learning approach for MV point localization and tracking capable of deriving such clinical metrics comparable to human expert-level performance, and validated it in a multi-vendor, multi-center clinical population. METHODS: The proposed pipeline first performs a coarse MV point annotation in a given cine accurately enough to apply an automated linear transformation task, which standardizes the size, cropping, resolution, and heart orientation, and second, tracks the MV points with high accuracy. The model was trained and evaluated on 38,854 cine images from 703 patients with diverse cardiovascular conditions, scanned on equipment from 3 main vendors, 16 centers, and 7 countries, and manually annotated by 10 observers. Agreement was assessed by the intra-class correlation coefficient (ICC) for both clinical metrics and by the distance error in the MV plane displacement. For inter-observer variability analysis, an additional pair of observers performed manual annotations in a randomly chosen set of 50 patients. RESULTS: MVnet achieved a fast segmentation (<1 s/cine) with excellent ICCs of 0.94 (MAPSE) and 0.93 (LV e') and a MV plane tracking error of -0.10 ± 0.97 mm. In a similar manner, the inter-observer variability analysis yielded ICCs of 0.95 and 0.89 and a tracking error of -0.15 ± 1.18 mm, respectively. CONCLUSION: A dual-stage deep learning approach for automated annotation of MV points for systolic and diastolic evaluation in CMR long-axis cine images was developed. The method is able to carefully track these points with high accuracy and in a timely manner. This will improve the feasibility of CMR methods which rely on valve tracking and increase their utility in a clinical setting.


Subject(s)
Magnetic Resonance Imaging, Cine , Mitral Valve , Humans , Magnetic Resonance Imaging , Mitral Valve/diagnostic imaging , Neural Networks, Computer , Predictive Value of Tests , Reproducibility of Results , Ventricular Function, Left
18.
Eur Heart J Cardiovasc Imaging ; 23(1): 14-30, 2021 12 18.
Article in English | MEDLINE | ID: mdl-34718484

ABSTRACT

Left atrial (LA) imaging is still not routinely used for diagnosis and risk stratification, although recent studies have emphasized its importance as an imaging biomarker. Cardiovascular magnetic resonance is able to evaluate LA structure and function, metrics that serve as early indicators of disease, and provide prognostic information, e.g. regarding diastolic dysfunction, and atrial fibrillation (AF). MR angiography defines atrial anatomy, useful for planning ablation procedures, and also for characterizing atrial shapes and sizes that might predict cardiovascular events, e.g. stroke. Long-axis cine images can be evaluated to define minimum, maximum, and pre-atrial contraction LA volumes, and ejection fractions (EFs). More modern feature tracking of these cine images provides longitudinal LA strain through the cardiac cycle, and strain rates. Strain may be a more sensitive marker than EF and can predict post-operative AF, AF recurrence after ablation, outcomes in hypertrophic cardiomyopathy, stratification of diastolic dysfunction, and strain correlates with atrial fibrosis. Using high-resolution late gadolinium enhancement (LGE), the extent of fibrosis in the LA can be estimated and post-ablation scar can be evaluated. The LA LGE method is widely available, its reproducibility is good, and validations with voltage-mapping exist, although further scan-rescan studies are needed, and consensus regarding atrial segmentation is lacking. Using LGE, scar patterns after ablation in AF subjects can be reproducibly defined. Evaluation of 'pre-existent' atrial fibrosis may have roles in predicting AF recurrence after ablation, predicting new-onset AF and diastolic dysfunction in patients without AF. LA imaging biomarkers are ready to enter into diagnostic clinical practice.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Biomarkers , Catheter Ablation/methods , Contrast Media , Fibrosis , Gadolinium , Heart Atria , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Reproducibility of Results
19.
Magn Reson Med ; 86(5): 2604-2617, 2021 11.
Article in English | MEDLINE | ID: mdl-34196041

ABSTRACT

PURPOSE: Deuterium metabolic imaging (DMI) maps the uptake of deuterated precursors and their conversion into lactate and other markers of tumor metabolism. Even after leveraging 2 H's short T1 s, DMI's signal-to-noise ratio (SNR) is limited. We hypothesize that a multi-echo balanced steady-state free precession (ME-bSSFP) approach would increase SNR compared to chemical shift imaging (CSI), while achieving spectral isolation of the metabolic precursors and products. METHODS: Suitably tuned 2 H ME-bSSFP (five echo times [TEs], ΔTE = 2.2 ms, repetition time [TR]/flip-angle = 12 ms/60°) was implemented at 15.2T and compared to CSI (TR/flip-angle = 95 ms/90°) regarding SNR and spectral isolation, in simulations, in deuterated phantoms and for the in vivo diagnosis of a mouse tumor model of pancreatic adenocarcinoma (N = 10). RESULTS: Simulations predicted an SNR increase vs. CSI of 3-5, and that the peaks of 2 H-water, 2 H6,6' -glucose, and 2 H3,3' -lactate can be well isolated by ME-bSSFP; phantoms confirmed this. In vivo, at equal spatial resolution (1.25 × 1.25 mm2 ) and scan time (10 min), 2 H6,6' -glucose's and 2 H3,3' -lactate's SNR were indeed higher for bSSFP than for CSI, three-fold for glucose (57 ± 30 vs. 19 ± 11, P < .001), doubled for water (13 ± 5 vs. 7 ± 3, P = .005). The time courses and overall localization of all metabolites agreed well, comparing CSI against ME-bSSFP. However, a clearer localization of glucose in kidneys and bladder, the detection of glucose-avid rims in certain tumors, and a heterogeneous pattern of intra-tumor lactate production could only be observed using ME-bSSFP's higher resolution. CONCLUSIONS: ME-bSSFP provides greater SNR per unit time than CSI, providing for higher spatial resolution mapping of glucose uptake and lactate production in tumors.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Animals , Deuterium , Magnetic Resonance Imaging , Mice , Pancreatic Neoplasms/diagnostic imaging , Phantoms, Imaging , Signal-To-Noise Ratio
20.
BMC Med Imaging ; 21(1): 101, 2021 06 19.
Article in English | MEDLINE | ID: mdl-34147081

ABSTRACT

BACKGROUND: Segmentation of the left atrium (LA) is required to evaluate atrial size and function, which are important imaging biomarkers for a wide range of cardiovascular conditions, such as atrial fibrillation, stroke, and diastolic dysfunction. LA segmentations are currently being performed manually, which is time-consuming and observer-dependent. METHODS: This study presents an automated image processing algorithm for time-resolved LA segmentation in cardiac magnetic resonance imaging (MRI) long-axis cine images of the 2-chamber (2ch) and 4-chamber (4ch) views using active contours. The proposed algorithm combines mitral valve tracking, automated threshold calculation, edge detection on a radially resampled image, edge tracking based on Dijkstra's algorithm, and post-processing involving smoothing and interpolation. The algorithm was evaluated in 37 patients diagnosed mainly with paroxysmal atrial fibrillation. Segmentation accuracy was assessed using the Dice similarity coefficient (DSC) and Hausdorff distance (HD), with manual segmentations in all time frames as the reference standard. For inter-observer variability analysis, a second observer performed manual segmentations at end-diastole and end-systole on all subjects. RESULTS: The proposed automated method achieved high performance in segmenting the LA in long-axis cine sequences, with a DSC of 0.96 for 2ch and 0.95 for 4ch, and an HD of 5.5 mm for 2ch and 6.4 mm for 4ch. The manual inter-observer variability analysis had an average DSC of 0.95 and an average HD of 4.9 mm. CONCLUSION: The proposed automated method achieved performance on par with human experts analyzing MRI images for evaluation of atrial size and function. Video Abstract.


Subject(s)
Algorithms , Atrial Fibrillation/diagnostic imaging , Atrial Function, Left/physiology , Heart Atria/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Atrial Fibrillation/physiopathology , Humans , Mitral Valve/diagnostic imaging , Observer Variation , Reference Standards , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL