Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 17(10): e0276649, 2022.
Article in English | MEDLINE | ID: mdl-36279295

ABSTRACT

BACKGROUND: Genetic variants in apolipoprotein L1 (APOL1), a protein that protects humans from infection with African trypanosomes, explain a substantial proportion of the excess risk of chronic kidney disease affecting individuals with sub-Saharan ancestry. The mechanisms by which risk variants damage kidney cells remain incompletely understood. In preclinical models, APOL1 expressed in podocytes can lead to significant kidney injury. In humans, studies in kidney transplant suggest that the effects of APOL1 variants are predominantly driven by donor genotype. Less attention has been paid to a possible role for circulating APOL1 in kidney injury. METHODS: Using liquid chromatography-tandem mass spectrometry, the concentrations of APOL1 were measured in plasma and urine from participants in the Seattle Kidney Study. Asymmetric flow field-flow fractionation was used to evaluate the size of APOL1-containing lipoprotein particles in plasma. Transgenic mice that express wild-type or risk variant APOL1 from an albumin promoter were treated to cause kidney injury and evaluated for renal disease and pathology. RESULTS: In human participants, urine concentrations of APOL1 were correlated with plasma concentrations and reduced kidney function. Risk variant APOL1 was enriched in larger particles. In mice, circulating risk variant APOL1-G1 promoted kidney damage and reduced podocyte density without renal expression of APOL1. CONCLUSIONS: These results suggest that plasma APOL1 is dynamic and contributes to the progression of kidney disease in humans, which may have implications for treatment of APOL1-associated kidney disease and for kidney transplantation.


Subject(s)
Apolipoprotein L1 , Renal Insufficiency, Chronic , Humans , Mice , Animals , Apolipoprotein L1/genetics , Apolipoprotein L1/metabolism , Apolipoproteins/genetics , Kidney/pathology , Renal Insufficiency, Chronic/genetics , Renal Insufficiency, Chronic/pathology , Mice, Transgenic , Disease Models, Animal , Albumins
2.
Am J Clin Pathol ; 157(5): 748-757, 2022 05 04.
Article in English | MEDLINE | ID: mdl-35512256

ABSTRACT

OBJECTIVES: Standard implementations of amyloid typing by liquid chromatography-tandem mass spectrometry use capabilities unavailable to most clinical laboratories. To improve accessibility of this testing, we explored easier approaches to tissue sampling and data processing. METHODS: We validated a typing method using manual sampling in place of laser microdissection, pairing the technique with a semiquantitative measure of sampling adequacy. In addition, we created an open-source data processing workflow (Crux Pipeline) for clinical users. RESULTS: Cases of amyloidosis spanning the major types were distinguishable with 100% specificity using measurements of individual amyloidogenic proteins or in combination with the ratio of λ and κ constant regions. Crux Pipeline allowed for rapid, batched data processing, integrating the steps of peptide identification, statistical confidence estimation, and label-free protein quantification. CONCLUSIONS: Accurate mass spectrometry-based amyloid typing is possible without laser microdissection. To facilitate entry into solid tissue proteomics, newcomers can leverage manual sampling approaches in combination with Crux Pipeline and related tools.


Subject(s)
Amyloidosis , Tandem Mass Spectrometry , Amyloid/analysis , Amyloidogenic Proteins , Amyloidosis/diagnosis , Humans , Microdissection , Tandem Mass Spectrometry/methods
3.
Clin Biochem ; 99: 111-117, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34678307

ABSTRACT

BACKGROUND: The measurement of plasma concentrations of retinol binding protein is a component of nutritional assessment in neonatal intensive care. However, serial testing in newborns is hampered by the limited amount of blood that can be sampled. Limitations are most severe with preterm infants, for whom close monitoring may be most important. METHODS: We developed an assay to quantify retinol binding protein using trypsin digestion and liquid chromatography-tandem mass spectrometry, which requires a serum or plasma volume of 5 µl. Additionally, we validated the method according to current recommendations and performed comparison with a standard nephelometry platform in clinical use. RESULTS: The assay demonstrated linearity from below 1 mg/dL (0.48 µM) to more than 20 mg/dL (9.7 µM), and an imprecision of 11.8% at 0.43 mg/dL (0.21 µM). The distribution of results observed with the new method was different when compared with nephelometry. CONCLUSION: Liquid chromatography-tandem mass spectrometry facilitated testing a smaller sample volume, thereby increasing the ability to monitor key nutritional markers in premature infants. The differences in results compared with a commercially-available nephelometric assay revealed questionable results for lower concentrations by immunoassay.


Subject(s)
Nutrition Assessment , Retinol-Binding Proteins/metabolism , Tandem Mass Spectrometry , Chromatography, Liquid , Female , Humans , Infant, Newborn , Male
4.
J Mass Spectrom Adv Clin Lab ; 19: 1-6, 2021 Jan.
Article in English | MEDLINE | ID: mdl-34723236

ABSTRACT

INTRODUCTION: C-peptide is used as a marker of endogenous insulin secretion in the assessment of residual ß-cell function in diabetes and in the diagnostic workup of hypoglycemia. Previously developed LC-MS/MS methods to quantify serum concentrations of C-peptide have monitored intact peptide, which ionizes poorly. As a result, methods have leveraged immunoaffinity enrichment or two-dimensional chromatography. In this study, we aimed to use proteolysis during sample preparation to enhance the sensitivity of traditional LC-MS/MS. METHODS: Due to the absence of arginine and lysine residues in C-peptide, we utilized Glu-C as the proteolytic enzyme in the method. After protein precipitation using acetonitrile and solid phase extraction with mixed anion exchange, lower molecular weight polypeptides were reduced, alkylated, and proteolyzed. The two amino-terminal peptide fragments, EAEDLQVGQVE and LGGGPGAGSLQPLALE, were monitored using multiple reaction monitoring in positive ion mode (Acquity ULPC-Xevo TQ-S, Waters). The former peptide was used for quantification and the latter for quality assurance. RESULTS: Glu-C was determined to be a reliable proteolytic enzyme with monotonic digestion kinetics. The assay was linear between 0.1 and 15 ng/mL and had a lower limit of quantification of 0.06 ng/mL. Total imprecision was 7.7 %CV and long-term imprecision at 0.16 ng/mL was 10.0%. Spike-recovery experiments demonstrated a mean recovery of 98.2 % (± 9.1 %) and the method compared favorably with a commercially available immunoassay and a reference measurement procedure. CONCLUSION: Protein precipitation with solid phase extraction and proteolysis with Glu-C is a robust sample preparation method for quantification of C-peptide in human serum by LC-MS/MS.

5.
Am J Clin Nutr ; 113(1): 83-91, 2021 Jan 04.
Article in English | MEDLINE | ID: mdl-33184642

ABSTRACT

BACKGROUND: Serum 25-hydroxyvitamin D [25(OH)D] concentration is an indicator of vitamin D exposure, but it is also influenced by clinical characteristics that affect 25(OH)D production and clearance. Vitamin D is the precursor to 25(OH)D but is analytically challenging to measure in biological specimens. OBJECTIVES: We aimed to develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantification of vitamins D3 and D2 in serum and to explore the potential of circulating vitamin D as a biomarker of exposure in supplementation trials. METHODS: The method was validated using guideline C62-A from the Clinical and Laboratory Standards Institute and was applied in 2 pilot clinical trials of oral vitamin D3 supplementation. Pilot study 1 included 22 adults randomly assigned to placebo or 2000 IU/d. Blood was collected at baseline, 1, 3, 6, and 12 mo. Pilot study 2 included 15 adults randomly assigned to 2000 or 4000 IU/d. Blood and subcutaneous (SUBQ) adipose tissue were collected at baseline and 3 mo. RESULTS: In study 1, mean change (baseline to 3 mo) in serum vitamin D3 was -0.1 ng/mL in the placebo group and 6.8 ng/mL in the 2000 IU/d group (absolute difference: 6.9; 95% CI: 4.5, 9.3 ng/mL). In study 2, mean change (baseline to 3 mo) in serum vitamin D3 was 10.4 ng/mL in the 2000 IU/d group and 22.2 ng/mL in the 4000 IU/d group (fold difference: 2.15; 95% CI: 1.40, 3.37). Serum and adipose tissue vitamin D3 concentrations were correlated, and the dose-response of vitamin D3 in adipose mirrored that in serum. CONCLUSIONS: We validated a sensitive, robust, and high-throughput LC-MS/MS method to quantify vitamins D3 and D2 in serum. Serum and SUBQ adipose tissue vitamin D3 concentrations increased proportionally to dose with 3 mo of daily supplementation.These trials were registered at clinicaltrials.gov as NCT00552409 (pilot study 1) and NCT01477034 (pilot study 2).

SELECTION OF CITATIONS
SEARCH DETAIL
...