Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 114
Filter
1.
Polymers (Basel) ; 16(9)2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38732694

ABSTRACT

This study investigates the mechanical properties of coconut sawdust powder combined with polypropylene (PP). The effect of compatibility content, wood powder (WP) content, and injection molding parameters on the properties of coconut wood powder composite (WPC) is evaluated. The results could be used to figure out the optimal mechanical properties such as tensile strength, elongation, elastic modulus, and flexural strength by selecting suitable parameters and composition. The bonding between the WP particles and the PP matrix is good, and the WP is uniformly distributed across the composite matrix, as indicated in the scanning electron microscopy (SEM) results. Interestingly, with the presence of the compatibilizer oleamide, increasing the WP content from 20 wt.% to 40 wt.% did not result in WP accumulation in the composite matrix. Notably, at 20 wt.% WP, the elongation is the highest (at 7.40 wt.%), while at 30 wt.% WP, the elastic modulus reaches the highest value. The maximum ultimate tensile strength (UTS) value is obtained at 35 wt.% WP. Higher WP mostly results in greater flexural strength and shore D hardness. At 40 wt.% WP, the WPC achieves its peak shore D hardness of 77.6. The Taguchi results suggest that WP content is the most critical factor in the UTS value of coconut WPCs. The filling pressure ranks second, followed by the packing pressure. Finally, unlike the other characteristics, the melt temperature has a minimal impact on the UTS value.

2.
Orthop Rev (Pavia) ; 16: 116365, 2024.
Article in English | MEDLINE | ID: mdl-38682045

ABSTRACT

Summary: Total knee replacement is increasingly widely prescribed, not only for degenerative joint disease but also for other problems such as articular cartilage disease, misalignment due to causes other than degeneration, bone and joint cancer, and diseases that cause joint destruction. However, changes in knee joint biomechanics as well as complications of the patellofemoral joint after surgery lead to instability, joint pain, patellar rupture, and patellar tendon rupture. These are issues that challenge surgeons as well as make patients hesitant when considering knee replacement surgery. Understanding the changes in patella index that can occur after total knee replacement surgery will help surgeons carefully evaluate patients before surgery and calculate intraoperative techniques to minimize complications. Methods: Fifty-eight patients with 62 knees were diagnosed with osteoarthritis and underwent total knee replacement surgery. All patients had clinical and radiographic evaluation of the knee joint before and after surgery. Results: Patellar indexes did not change significantly after surgery compared to before surgery. Before surgery, 2 patients (3.23%) had true patella baja. After surgery, 7 patients (11.29%) had true patella baja and 3 patients (4.84%) had pseudo-patella baja. The average knee flexion amplitude after surgery was 103.11±15.440, with only 2 patients losing extension >50º. The average KS score after surgery was 83.69±9.98, significantly improved compared to before surgery 33.44±11.38. Similarly, KFS score after surgery was 81.01±8.84 compared to before surgery 37.05±8.08. Conclusion: Changes in index of the patella before and after surgery affect the surgical results, the normal patella group has better results than the group with patella baja.

3.
J Vasc Access ; : 11297298241235954, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38506793

ABSTRACT

Dialysis access thrombosis is a common complication in the process of care. With the introduction of endovascular AV-fistulas [AVF]s the situation gained complexity with new potential thrombosis localizations. Several thrombectomy methods are available for recanalization of thrombosed AVFs ranging from invasive surgical methods to minimal invasive endovascular approaches. Early assessment, diagnosis and treatment is crucial for prolonging the life span of an AVF and preventing the need for placement of central venous catheters. To our best knowledge, we present the first case in which an obstructed antecubital communicating vein (aka perforating vein) of an endovascular created AVF was re-opened via interventional thrombectomy with the Rotarex® System (BD Interventional). The procedure was performed primarily under ultrasound guidance with fluoroscopic support. Our case report shows that this method, if done correctly and successfully, may prevent loss of the dialysis access. Additionally, we point towards the central role of ultrasound in this method.

4.
Orthop Rev (Pavia) ; 16: 94242, 2024.
Article in English | MEDLINE | ID: mdl-38469578

ABSTRACT

Background: The anatomical parameters of the acetabulum vary among races and geographical regions. Multislice Computed Tomography (CT) has proven to be a practical approach to assess morphological parameters of the acetabulum. The purpose of this study was to explore morphological characteristics of the acetabulum measured by CT scans in Vietnamese adults. Methods: Thirty-five consecutive patients aged 18 years and older received indications and eligibility for total hip replacement surgery. Sixty-three acetabulum were examined with multislice computed tomographic system (CT) with multiplanar reconstruction (MPR). Measured morphometric parameters of acetabulum included acetabular inclination angle (AIA), acetabular anteversion angle (AAA), acetabular angle of sharp (AAS), sagittal acetabular angle (SAA), acetabular horizontal offset (AHO), transverse acetabular ligament anteversion (TALA), transverse acetabular ligament inclination (TALI), acetabular depth (ADe), acetabular depth ratio (ADr) and acetabular diameter (ADi). Results: The mean values of acetabular diameter, femoral head diameter, AIA, AAA, AAS, SAA, TALA, TALI, AHO, ADe, ADr were 50.22±3.56 mm, 43.54±3.68 mm, 40.27±5.09 mm, 13.30±5.54 mm, 39.46±5.41 mm, 26.38±9.01 mm, 9.49±3.92 mm, 47.70±6.73 mm, 3.06±0.37 mm, 18.62±2.95 mm and 309.60±41.87 mm. Conclusion: Our initial data has showed morphological characteristics of the acetabulum in Vietnamese adults, different from the populations from other parts of world. Also, significant correlation between the orientation of the acetabulum and the transverse acetabular ligament was documented.

5.
Protein J ; 43(2): 159-170, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38485875

ABSTRACT

The immune system maintains constant surveillance to prevent the infiltration of both endogenous and exogenous threats into host organisms. The process is regulated by effector immune cells that combat external pathogens and regulatory immune cells that inhibit excessive internal body inflammation, ultimately establishing a state of homeostasis within the body. Disruption to this process could lead to autoimmunity, which is often associated with the malfunction of both T cells and B cells with T cells playing a more major role. A number of therapeutic mediators for autoimmune diseases are available, from conventional disease-modifying drugs to biologic agents and small molecule inhibitors. Recently, ribosomally synthesized peptides, specifically cyclotides from plants are currently attracting more attention as potential autoimmune disease therapeutics due to their decreased toxicity compared to small molecules inhibitors as well as their remarkable stability against a number of factors. This review provides a concise overview of various cyclotides exhibiting immunomodulatory properties and their potential as therapeutic interventions for autoimmune diseases.


Subject(s)
Autoimmune Diseases , Cyclotides , Humans , Autoimmune Diseases/drug therapy , Autoimmune Diseases/immunology , Cyclotides/therapeutic use , Cyclotides/chemistry , Cyclotides/pharmacology , Immunosuppressive Agents/therapeutic use , Immunosuppressive Agents/pharmacology , Animals
6.
Polymers (Basel) ; 16(3)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38337283

ABSTRACT

This study surveys the impacts of injection parameters on the deformation rate of the injected flexure hinge made from ABS, PP, and HDPE. The flexure hinges are generated with different filling time, filling pressure, filling speed, packing time, packing pressure, cooling time, and melt temperature. The amplification ratio of the samples between different injection parameters and different plastic types is measured and compared to figure out the optimal one with a high amplification ratio. The results show that the relationship between the input and output data of the ABS, PP, and HDPE flexure hinges at different injection molding parameters is a linear relation. Changing the material or many injection molding parameters of the hinge could lead to a great impact on the hinge's performance. However, changing each parameter does not lead to a sudden change in the input and output values. Each plastic material has different optimal injection parameters and displacement behaviors. With the ABS flexure hinge, the filling pressure case has the greatest amplification ratio of 8.81, while the filling speed case has the lowest value of 4.81. With the optimal injection parameter and the input value of 105 µm, the ABS flexure hinge could create a maximum average output value of 736.6 µm. With the PP flexure hinge, the melt temperature case achieves the greatest amplification ratio of 6.73, while the filling speed case has the lowest value of 4.1. With the optimal injection parameter and the input value of 128 µm, the PP flexure hinge could create a maximum average output value of 964.8 µm. The average amplification ratio values of all injection molding parameters are 6.85, 5.41, and 4.01, corresponding to ABS, PP, and HDPE flexure hinges. Generally, the ABS flexure hinge has the highest amplification ratios, followed by the PP flexure hinge. The HDPE flexure hinge has the lowest amplification ratios among these plastic types. With the optimal injection parameter and the input value of 218 µm, the HDPE flexure hinge could create a maximum average output value of 699.8 µm. The results provide more insight into plastic flexure hinges and broaden their applications by finding the optimal injection parameters and plastic types.

7.
J Pept Sci ; 30(6): e3570, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38317283

ABSTRACT

Chemical pesticides remain the predominant method for pest management in numerous countries. Given the current landscape of agriculture, the development of biopesticides has become increasingly crucial. The strategy empowers farmers to efficiently manage pests and diseases, while prioritizing minimal adverse effects on the environment and human health, hence fostering sustainable management. In recent years, there has been a growing interest and optimism surrounding the utilization of peptide biopesticides for crop protection. These sustainable and environmentally friendly substances have been recognized as viable alternatives to synthetic pesticides due to their outstanding environmental compatibility and efficacy. Numerous studies have been conducted to synthesize and identify peptides that exhibit activity against significant plant pathogens. One of the peptide classes is cyclotides, which are cyclic cysteine-rich peptides renowned for their wide range of sequences and functions. In this review, we conducted a comprehensive analysis of cyclotides, focusing on their structural attributes, developmental history, significant biological functions in crop protection, techniques for identification and investigation, and the application of biotechnology to enhance cyclotide synthesis. The objective is to emphasize the considerable potential of cyclotides as the next generation of plant protection agents on the global scale.


Subject(s)
Agriculture , Cyclotides , Cyclotides/chemistry , Agriculture/methods , Biological Control Agents/chemistry , Pesticides/chemistry , Humans
8.
Toxicon ; 239: 107606, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38181837

ABSTRACT

Cyclotides, plant-derived cysteine-rich peptides, exhibit a wide range of beneficial biological activities and possess exceptional structural stability. Cyclotides are commonly distributed throughout the Violaceae family. Viola dalatensis Gagnep, a Vietnamese species, has not been well studied, especially for cyclotides. This pioneering research explores cyclotides from V. dalatensis as antimicrobials. This study used a novel approach to enhance cyclotides after extraction. The approach combined 30% ammonium sulfate salt precipitation and RP-HPLC. A comprehensive analysis was performed to ascertain the overall protein content, flavonoids content, polyphenol content, and free radical scavenging capacity of compounds derived from V. dalatensis. Six known cyclotides were sequenced utilizing MS tandem. Semi-purified cyclotide mixtures (M1, M2, and M3) exhibited antibacterial efficacy against Bacillus subtilis (inhibitory diameters: 19.67-23.50 mm), Pseudomonas aeruginosa (22.17-23.50 mm), and Aspergillus flavus (14.67-21.33 mm). The enriched cyclotide precipitate from the stem extract demonstrated a minimum inhibitory concentration (MIC) of 0.08 mg/mL against P. aeruginosa, showcasing significant antibacterial effectiveness compared to the stem extract (MIC: 12.50 mg/mL). Considerable advancements have been achieved in the realm of cyclotides, specifically in their application as antimicrobial agents.


Subject(s)
Cyclotides , Viola , Cyclotides/pharmacology , Cyclotides/chemistry , Viola/chemistry , Viola/metabolism , Plant Extracts/pharmacology , Plant Extracts/chemistry , Anti-Bacterial Agents/chemistry , Vietnam
9.
Radiol Case Rep ; 19(3): 867-871, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38188962

ABSTRACT

Bile duct injuries are rare complications of hepatobiliary pancreatic surgery, leading to severe complications if not timely diagnosed and treated, with surgery traditionally being the primary treatment option. However, percutaneous transhepatic or endoscopic interventions have recently gained widespread use. We present a case study of a patient with variant biliary anatomy, who suffered biliary tract injury postcholedochal cyst resection and Roux-en-Y hepaticojejunostomy; successfully treated with percutaneous transhepatic bilioenteric neoanastomosis, guided by ultrasound and digital subtraction angiography (DSA).

10.
Polymers (Basel) ; 15(20)2023 Oct 16.
Article in English | MEDLINE | ID: mdl-37896346

ABSTRACT

This study examines the impact of injection parameters on the weld line strength of the polyamide 6 and 30% fiberglass (PA6 + 30% FG) composite samples. The effects of filling time, packing time, packing pressure, melt temperature, and mold temperature on the ultimate tensile strength (UTS) and the elongation value of the weld line are investigated. The results reveal that the filling time factor has the lowest influence rate. On the contrary, the packing pressure has the most considerable value of UTS standard deviation, indicating that this factor has a high impact rate. The melt temperature factor has the highest elongation standard deviation, pointing out the strong impact of melt temperature on the elongation value. In reverse, the filling time factor has the lowest elongation standard deviation, showing the low impact of this factor on the elongation value. Increasing the mold temperature enhances the elongation value greatly because a higher temperature generates a better connection in the weld line area. Although the UTS value improves modestly when the mold temperature control system is used, the elongation result from the mold temperature parameter is better than expected. The UTS result from all parameters presents a minor deviation; therefore, it is lower than expected. The optimal strength result from artificial neural networks with genetic algorithm optimization is 85.1 MPa, which is higher than the best experiment result of 76.8 MPa. Scanning electron microscopy (SEM) results show that the interface between the fiberglass and the PA matrix has high adherence. The fracture surface is smooth, indicating that the PA6 + 30% FG composite sample has a high fragility level. The findings could help to increase the injection sample's weld line strength by optimizing the injection molding conditions.

11.
Micromachines (Basel) ; 14(4)2023 Apr 08.
Article in English | MEDLINE | ID: mdl-37421060

ABSTRACT

The wire Arc Additive Manufacturing (WAAM) technique has evolved into a cutting-edge 3D printing technique. This study surveys the influences of trajectory on the characteristics of low-carbon steel samples generated by the WAAM technique. The results show that the grains in the WAAM samples are isotropic, with grain size numbers ranging from 7 to 12. Strategy 3, with a spiral trajectory, has the smallest grain size, while strategy 2, with a lean zigzag trajectory, has the largest. The variations in grain size are caused by differences in heat input and output during the printing process. The WAAM samples achieve a significantly higher UTS value than the original wire, demonstrating the WAAM technique's benefit. Strategy 3, with a spiral trajectory, achieves the highest UTS value, 616.5 MPa, 24% higher than the original wire. The UTS values of strategy 1 (horizontal zigzag trajectory) and strategy 4 (curve zigzag trajectory) are comparable. WAAM samples have significantly higher elongation values than the original wire, with only 22% elongation. The sample with the highest elongation value, 47.2%, was produced by strategy 3. Strategy 2 has an elongation value of 37.9%. The value of elongation is proportional to the value of UTS. WAAM samples have average elastic modulus values of 95.8 GPa, 173.3 GPa, 92.2 GPa, and 83.9 GPa, corresponding to strategies 1, 2, 3, and 4. Only a strategy 2 sample has a similar elastic modulus value to the original wire. All samples have dimples on the fracture surface, indicating that the WAAM samples are ductile. These fracture surfaces' equiaxial shape corresponds to the original microstructure's equiaxial shape. The results provide the optimal trajectory for the WAAM products is the spiral trajectory, while the lean zigzag trajectory gains only modest characteristics.

12.
Polymers (Basel) ; 15(13)2023 Jun 23.
Article in English | MEDLINE | ID: mdl-37447439

ABSTRACT

Mold heating is an essential process in plastic injection molding. Raising the temperature of the mold before injecting liquefied plastic can ease the mold-filling process. A cooling channel can be used to transport high-temperature fluids for this purpose, such as hot water or oil. This dual purpose is a cost-effective solution for heating the mold because the target temperature is easily achieved using this method. In addition, a conformal cooling channel (CCC) can provide more efficient mold heating than a straight cooling channel. This study used the response surface methodology to determine the optimum CCC shape for heat distribution in a mold, and the simulation results confirmed its optimization. The average temperature of the mold using a CCC was better than that using a straight cooling channel, and the heat zone was uniform across the mold surface.

13.
Int J Mol Sci ; 24(11)2023 May 26.
Article in English | MEDLINE | ID: mdl-37298286

ABSTRACT

T-cell recognition of antigens is complex, leading to biochemical and cellular events that impart both specific and targeted immune responses. The end result is an array of cytokines that facilitate the direction and intensity of the immune reaction-such as T-cell proliferation, differentiation, macrophage activation, and B-cell isotype switching-all of which may be necessary and appropriate to eliminate the antigen and induce adaptive immunity. Using in silico docking to identify small molecules that putatively bind to the T-cell Cß-FG loop, we have shown in vitro using an antigen presentation assay that T-cell signalling is altered. The idea of modulating T-cell signalling independently of antigens by directly targeting the FG loop is novel and warrants further study.


Subject(s)
Signal Transduction , T-Lymphocytes , Receptors, Antigen, T-Cell, alpha-beta , Receptors, Antigen/metabolism , Cytokines/metabolism , Receptors, Antigen, T-Cell/metabolism
14.
Polymers (Basel) ; 15(11)2023 May 25.
Article in English | MEDLINE | ID: mdl-37299239

ABSTRACT

This study presents an innovative approach to enhancing weld line strength in advanced polymer injection molding through applying gas-assisted mold temperature control, significantly increasing mold temperature beyond typical values observed in conventional processes. We investigate the effects of various heating times and frequencies on the fatigue strength of Polypropylene (PP) samples and the tensile strength of Acrylonitrile Butadiene Styrene (ABS) composite samples at different Thermoplastic Polyurethane (TPU) percentages and heating times. Using gas-assisted mold heating, mold temperatures exceeding 210 °C are achieved, which represents a significant advancement compared to the standard mold temperatures of less than 100 °C. As a result, the fatigue strength of the PP sample with mold heating at 15 s shows a remarkable increase of up to 5.4 times at 5 Hz compared to the sample without mold temperature control. Moreover, ABS/TPU blends with 15 wt.% TPU exhibit the highest ultimate tensile strength (UTS) value of 36.8 MPa, while blends with 30 wt.% TPU have the lowest UTS value of 21.3 MPa. This advancement demonstrates the potential for improved welding line bonding and fatigue strength in manufacturing. Our findings reveal that increasing the mold temperature before injection results in higher fatigue strength in the weld line, with the TPU percentage having a more significant influence on the mechanical properties of ABS/TPU blends than heating time. The results of this study contribute to a deeper understanding of advanced polymer injection molding and offer valuable insights for process optimization.

15.
Polymers (Basel) ; 15(10)2023 May 16.
Article in English | MEDLINE | ID: mdl-37242896

ABSTRACT

This study aims to explore the effects of Thermoplastic Polyurethane (TPU) content on the weld line properties of Polypropylene (PP) and Acrylonitrile Butadiene Styrene (ABS) blends. In PP/TPU blends, increasing the TPU content results in a significant decrease in the PP/TPU composite's ultimate tensile strength (UTS) and elongation values. Blends with 10 wt%, 15 wt%, and 20 wt% TPU and pure PP outperform blends with 10 wt%, 15 wt%, and 20 wt% TPU and recycled PP in terms of UTS value. The blend with 10 wt% TPU and pure PP achieves the highest UTS value of 21.85 MPa. However, the blend's elongation decreases due to the poor bonding in the weld line area. According to Taguchi's analysis, the TPU factor has a more significant overall influence on the mechanical properties of PP/TPU blends than the recycled PP factor. Scanning electron microscope (SEM) results show that the TPU area has a dimple shape on the fracture surface due to its significantly higher elongation value. The 15 wt% TPU sample achieves the highest UTS value of 35.7 MPa in ABS/TPU blends, which is considerably higher than other cases, indicating good compatibility between ABS and TPU. The sample containing 20 wt% TPU has the lowest UTS value of 21.2 MPa. Furthermore, the elongation-changing pattern corresponds to the UTS value. Interestingly, SEM results present that the fracture surface of this blend is flatter than the PP/TPU blend due to a higher compatibility rate. The 30 wt% TPU sample has a higher rate of dimple area than the 10 wt% TPU sample. Moreover, ABS/TPU blends gain a higher UTS value than PP/TPU blends. Increasing the TPU ratio mainly reduces the elastic modulus of both ABS/TPU blends and PP/TPU blends. This study reveals the advantages and disadvantages of mixing TPU with PP or ABS to ensure that it meets the requirements of the intended applications.

16.
Diagnostics (Basel) ; 13(8)2023 Apr 07.
Article in English | MEDLINE | ID: mdl-37189465

ABSTRACT

Shortly after its emergence, Omicron and its sub-variants have quickly replaced the Delta variant during the current COVID-19 outbreaks in Vietnam and around the world. To enable the rapid and timely detection of existing and future variants for epidemiological surveillance and diagnostic applications, a robust, economical real-time PCR method that can specifically and sensitively detect and identify multiple different circulating variants is needed. The principle of target- failure (TF) real-time PCR is simple. If a target contains a deletion mutation, then there is a mismatch with the primer or probe, and the real-time PCR will fail to amplify the target. In this study, we designed and evaluated a novel multiplex RT real-time PCR (MPL RT-rPCR) based on the principle of target failure to detect and identify different variants of SARS-CoV-2 directly from the nasopharyngeal swabs collected from COVID-19 suspected cases. The primers and probes were designed based on the specific deletion mutations of current circulating variants. To evaluate the results from the MPL RT-rPCR, this study also designed nine pairs of primers for amplifying and sequencing of nine fragments from the S gene containing mutations of known variants. We demonstrated that (i) our MPL RT-rPCR was able to accurately detect multiple variants that existed in a single sample; (ii) the limit of detection of the MPL RT-rPCR in the detection of the variants ranged from 1 to 10 copies for Omicron BA.2 and BA.5, and from 10 to 100 copies for Delta, Omicron BA.1, recombination of BA.1 and BA.2, and BA.4; (iii) between January and September 2022, Omicron BA.1 emerged and co-existed with the Delta variant during the early period, both of which were rapidly replaced by Omicron BA.2, and this was followed by Omicron BA.5 as the dominant variant toward the later period. Our results showed that SARS-CoV-2 variants rapidly evolved within a short period of time, proving the importance of a robust, economical, and easy-to-access method not just for epidemiological surveillance but also for diagnoses around the world where SARS-CoV-2 variants remain the WHO's highest health concern. Our highly sensitive and specific MPL RT-rPCR is considered suitable for further implementation in many laboratories, especially in developing countries.

17.
Toxicon ; 230: 107173, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37211058

ABSTRACT

Greater levels of insect resistance and constraints on the use of current pesticides have recently led to increased crop losses in agricultural production. Further, the health and environmental impacts of pesticides now restrict their application. Biologics based on peptides are gaining popularity as efficient crop protection agents with low environmental toxicity. Cysteine-rich peptides (whether originated from venoms or plant defense substances) are chemically stable and effective as insecticides in agricultural applications. Cysteine-rich peptides fulfill the stability and efficacy requirements for commercial uses and provide an environmentally benign alternative to small-molecule insecticides. In this article, cysteine-rich insecticidal peptide classes identified from plants and venoms will be highlighted, focusing on their structural stability, bioactivity and production.


Subject(s)
Insecticides , Animals , Insecticides/chemistry , Cysteine , Peptides/chemistry , Insecta , Venoms
18.
Amino Acids ; 55(6): 713-729, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37142771

ABSTRACT

Cyclotides are plant peptides characterized with a head-to-tail cyclized backbone and three interlocking disulfide bonds, known as a cyclic cysteine knot. Despite the variations in cyclotides peptide sequences, this core structure is conserved, underlying their most useful feature: stability against thermal and chemical breakdown. Cyclotides are the only natural peptides known to date that are orally bioavailable and able to cross cell membranes. Cyclotides also display bioactivities that have been exploited and expanded to develop as potential therapeutic reagents for a wide range of conditions (e.g., HIV, inflammatory conditions, multiple sclerosis, etc.). As such, in vitro production of cyclotides is of the utmost importance since it could assist further research on this peptide class, specifically the structure-activity relationship and its mechanism of action. The information obtained could be utilized to assist drug development and optimization. Here, we discuss several strategies for the synthesis of cyclotides using both chemical and biological routes.


Subject(s)
Cyclotides , Cyclotides/pharmacology , Cyclotides/therapeutic use , Cyclotides/chemistry , Amino Acid Sequence , Plants/metabolism , Cysteine , Structure-Activity Relationship
19.
Micromachines (Basel) ; 14(5)2023 May 10.
Article in English | MEDLINE | ID: mdl-37241649

ABSTRACT

Nowadays, machining products, especially by turning methods, are more and more popular and require high-quality. With the development of science and technology, especially numerical computing technology and control technology, the application of these technological achievements to improve productivity and product quality has become increasingly essential. This study applies a simulation method considering the affecting factors of the vibration of the tool and the surface quality of the workpiece during turning. The study simulated and analyzed the characteristics of the cutting force and oscillation of the toolholder when stabilizing; at the same time, the study also simulated the behavior of the toolholder under the effect of cutting force and determined the finished surface quality through simulation. Additionally, the study utilized a machine learning model to examine the relationship between the toolholder length, cutting speed, feed rate, wavelength and surface roughness. The study found that tool hardness is the most crucial factor, and if the toolholder length exceeds the critical length, it leads to a rapid increase in roughness. In this study, the critical toolholder length was determined to be 60 mm, and this resulted in a corresponding surface roughness (Rz) of approximately 20 µm.

20.
Osteoporos Int ; 34(8): 1381-1387, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37106043

ABSTRACT

Based on the prospective cohort of the Vietnam Osteoporosis Study, we show that bone loss occurred before menopause, and that the loss accelerated in the first 5 years post-menopause. PURPOSE: To define the change in bone mineral density (BMD) among women during the menopausal transition. METHODS: The study involved 1062 women aged 40-59 who were participants of the population-based prospective Vietnam Osteoporosis Study. BMD at the femoral neck (FN), lumbar spine (LS), and whole body scan was measured by DXA. Each woman has had two BMD measurements separated by approximately 2 years, and the rate of BMD change was calculated for each woman. Multivariable linear regression models were used to quantify the association between body composition parameters and the rate of BMD change. RESULTS: At FN, there were 3 phases of BMD change: a slight decline before the age of 45-49 (average loss of 0.51%/year); a substantial decline between the ages of 49 and 54 (average loss of 1.39%/year); and then slowed down between the ages of 54 and 59 (average loss of 0.31%/year). The same trend was also observed at LS: a slight decline (- 0.56%/year) among women aged 45-49; then a significant decline between the ages of 50 and 54 (- 1.33%/year); but then slowed down at - 0.31%/year after the age of 55. Changes in BMD were not significantly associated with changes in lean mass or fat mass. CONCLUSIONS: Although bone loss occurred before menopause, the loss accelerated in the early perimenopausal transition (45-50 years of age). This finding suggests that screening for osteoporosis in women should be considered at the age of 45.


Subject(s)
Osteoporosis, Postmenopausal , Osteoporosis , Female , Humans , Middle Aged , Bone Density , Perimenopause , Prospective Studies , Vietnam/epidemiology , Osteoporosis/epidemiology , Osteoporosis/etiology , Lumbar Vertebrae , Osteoporosis, Postmenopausal/epidemiology , Femur Neck
SELECTION OF CITATIONS
SEARCH DETAIL
...