Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Appl Opt ; 57(24): 6892-6897, 2018 Aug 20.
Article in English | MEDLINE | ID: mdl-30129573

ABSTRACT

We present a Raman converter emitting at 583 nm on the second Stokes order of a line of propan-2-ol pumped by a microlaser at 532 nm in the sub-nanosecond regime. We used a mixture of liquids to adapt the transmission band of a photonic bandgap fiber. The internal conversion efficiency is 67% in photon numbers, and the output power is 1.06 mW, corresponding to a maximum peak power of 338 W. The beam delivered by the converter presents a Gaussian spatial structure and a high spectral brightness, typically more than five times higher than supercontinuum sources in this spectral range.

2.
J Cardiovasc Transl Res ; 3(6): 643-51, 2010 Dec.
Article in English | MEDLINE | ID: mdl-20842468

ABSTRACT

Studies of myocardial metabolism have reported that contractile performance at a given myocardial oxygen consumption (MVO2) can be lower when the heart is oxidizing fatty acids rather than glucose or lactate. The objective of this study is to assess the prognostic value of myocardial metabolic phenotypes in identifying non-responders among non-ischemic dilated cardiomyopathy (NIDCM) patients undergoing cardiac resynchronization therapy (CRT). Arterial and coronary sinus plasma concentrations of oxygen, glucose, lactate, pyruvate, free fatty acids (FFA), and 22 amino acids were obtained from 19 male and 2 female patients (mean age 56 ± 16) with NIDCM undergoing CRT. Metabolite fluxes/MVO2 and extraction fractions were calculated. Flux balance analysis (FBA) was performed with MetaFluxNet 1.8 on a metabolic network of the cardiac mitochondria (189 reactions, 230 metabolites) reconstructed from mitochondrial proteomic data (615 proteins) from human heart tissue. Non-responders based on left ventricular ejection fraction (LVEF) demonstrated a greater mean FFA extraction fraction (35% ± 17%) than responders [18 ± 10%, p = 0.0098, area under the estimated ROC curve (AUC) was 0.8238, S.E. 0.1115]. Calculated adenosine triphosphate (ATP)/MVO2 using FBA correlated with change in New York Heart Association (NYHA) class (rho = 0.63, p = 0.0298; AUC = 0.8381, S.E. 0.1316). Non-responders based on both LVEF and NYHA demonstrated a greater mean FFA uptake/MVO2 (0.115 ± 0.112) than responders (0.034 ± 0.030, p = 0.0171; AUC = 0.8593, S.E. 0.0965). Myocardial FFA flux and calculated maximal ATP synthesis flux using FBA may be helpful as biomarkers in identifying non-responders among NIDCM patients undergoing CRT.


Subject(s)
Cardiac Resynchronization Therapy , Cardiomyopathy, Dilated/therapy , Energy Metabolism , Heart Failure/therapy , Myocardium/metabolism , Oxygen Consumption , Ventricular Function, Left , Adenosine Triphosphate/metabolism , Adult , Aged , Amino Acids/blood , Biomarkers/blood , Blood Glucose/metabolism , Cardiomyopathy, Dilated/blood , Cardiomyopathy, Dilated/physiopathology , Fatty Acids, Nonesterified/blood , Female , Heart Failure/blood , Heart Failure/physiopathology , Humans , Lactic Acid/blood , Male , Middle Aged , Mitochondria, Heart/metabolism , Myocardial Contraction , Oxygen/blood , Phenotype , Prospective Studies , Proteomics , Pyruvic Acid/blood , Stroke Volume , Time Factors , Treatment Failure
3.
Opt Lett ; 32(16): 2390-2, 2007 Aug 15.
Article in English | MEDLINE | ID: mdl-17700795

ABSTRACT

We present a photosensitive three-hole microstructured optical fiber specifically designed to improve the refractive index sensitivity of a standard fiber Bragg grating (FBG) sensor photowritten in the suspended Ge-doped silica core. We describe the specific photowriting procedure used to realize gratings in such a fiber. We then determine their spectral sensitivity to the refractive index changes of material filling the holes surrounding the core. The sensitivity is compared with that of standard FBGs photowritten in a six-hole fiber with a larger core diameter. We demonstrate an improvement in the sensitivity by two orders of magnitude and reach a resolution of 3 x 10(-5) and 6 x 10(-6) around mean refractive index values of 1.33 and 1.40, respectively.

4.
Opt Express ; 14(22): 10359-70, 2006 Oct 30.
Article in English | MEDLINE | ID: mdl-19529434

ABSTRACT

We report what we believe to be the first Tilted short-period Fiber Bragg Grating photowritten in a microstructured optical fiber for refractive index measurement. We investigate the spectral sensitivity of Tilted Fiber Bragg Grating to refractive index liquid inserted into the holes of a multimode microstructured fiber. We measure the wavelength shift of the first four modes experimentally observed when calibrated oils are inserted into the fiber holes, and thus we determine the refractive index resolution for each of these modes. Moreover, a cross comparison between experimental and simulation results of a modal analysis is performed. Two simulation tools are used, respectively based on the localized functions method and on a finite element method. All results are in very good agreement.

SELECTION OF CITATIONS
SEARCH DETAIL