Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Anal Methods Chem ; 2021: 6641326, 2021.
Article in English | MEDLINE | ID: mdl-34136305

ABSTRACT

Polycyclic aromatic hydrocarbons (PAHs), the family of organic contaminations, have been shown to have negative effects on human health. However, until now, the comprehension on occurrence, distribution, and risk assessment of human exposure to PAHs has been limited in Vietnam. In this work, a capillary gas chromatography coupled with electron impact ionization tandem mass spectrometry (GC-EI-MS/MS) has been introduced for analysis of 16 PAHs in some particulate matter samples. PAHs have been separated on the TG 5 ms capillary gas chromatographic column and detected by tandem mass spectrometry in multiple reaction monitoring mode. The PAHs in the particulate matter (PM 2.5 and PM 10) samples were extracted by ultrasonic-assisted liquid extraction and cleaned up by an acidic silica gel solid phase extraction. The linearity range of all analyzed PAHs was from 5 to 2000 ng mL-1 with R 2 ≥0.9990. Limit of detection (LOD) of PAHs in particulate matter sample was from 0.001 ng m-3 (Br-Naph) to 0.276 ng m-3 (Fln). The recovery of PAHs was investigated by international proficiency testing samples. The recoveries of PAHs in proficiency testing sample ranged from 79.3% (Chr) to 109.8% (IcdP). The in-house validated GC-EI-MS/MS method was then applied to analysis of some particulate matter samples that were collected in the Hanoi areas. The total concentrations of PAHs in several brands of samples collected from Hanoi were found in the range of 226.3 ng m-3-706.43 ng m-3. Among the studied compounds, naphthalene was found at high frequency and ranged from 106.5 ng m-3 to 631.1 ng m-3. The main distribution of the PAHs in particulate matter samples was two-ring and three-ring compounds.

2.
J Chromatogr A ; 1649: 462188, 2021 Jul 19.
Article in English | MEDLINE | ID: mdl-34034108

ABSTRACT

A new green method for trace level quantification of four herbicides, glyphosate (GLYP), glufosinate (GLUF), and their main metabolites, aminomethylphosphonic acid (AMPA) and 3-(methyl-phosphinico)-propionic acid (MPPA), was developed. The purification step without any derivatization was conducted by solid-phase extraction using Chelex-100 resin in the Fe (III) form, followed by elution with 5% NH4OH. The four analytes were quantified by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry. The developed extraction method was validated on five fresh and sea water matrices with mean recoveries ranging from 80.1% to 109.4% (relative standard deviation < 20%). The extraction conditions were evaluated and certified for the high applicability of the extraction method too. The limits of detection (ng/L) in the five water matrices were in ranges 0.70 - 4.0, 2.4 - 3.9, 1.8 - 4.7, and 1.6 - 4.0 for GLYP, AMPA, GLUF, and MPPA, respectively. The method was successfully applied to detect the four compounds in surface waters sampled along the Red River Delta region in July 2019. The highest concentrations were detected at 565, 1,330, 234, and 871 ng/L for GLYP, AMPA, GLUF, and MPPA, respectively. These results showed the potential capacity of this new method for convenient monitoring of herbicides and their metabolites in the diverse natural water system.


Subject(s)
Aminobutyrates/isolation & purification , Glycine/analogs & derivatives , Organophosphonates/isolation & purification , Solid Phase Extraction/methods , Water Pollutants, Chemical/isolation & purification , Aminobutyrates/analysis , Chromatography, High Pressure Liquid , Fresh Water/chemistry , Glycine/analysis , Glycine/isolation & purification , Herbicides/analysis , Herbicides/isolation & purification , Organophosphonates/analysis , Tandem Mass Spectrometry , Water Pollutants, Chemical/analysis , Glyphosate
3.
J Anal Methods Chem ; 2021: 6628285, 2021.
Article in English | MEDLINE | ID: mdl-33505763

ABSTRACT

In this study, an analytical method for the simultaneous determination of 7 major pharmaceutical residues in Vietnam, namely, carbamazepine, ciprofloxacin, ofloxacin, ketoprofen, paracetamol, sulfamethoxazole, and trimethoprim, in surface water and hospital wastewater has been developed. The method includes enrichment and clean-up steps by solid phase extraction using mix-mode cation exchange, followed by identification and quantification using an ultrahigh-performance liquid chromatography and tandem mass spectrometry and employing electrospray ionization (UPLC-ESI-MS/MS). Seven target compounds were separated on the reversed phase column and detected in multiple reaction monitoring (MRM) mode within 6 minutes. The present study also optimized the operating parameters of the mass spectrometer to achieve the highest analytical signals for all target compounds. All characteristic parameters of the analytical method were investigated, including linearity range, limit of detection, limit of quantification, precision, and accuracy. The important parameter in UPLC-ESI-MS/MS, matrix effect, was assessed and implemented via preextraction and postextraction spiking experiments. The overall recoveries of all target compounds were in the ranges from 55% to 109% and 56 % to 115% for surface water and hospital wastewater, respectively. Detection limits for surface water and hospital wastewater were 0.005-0.015 µg L-1 and 0.014-0.123 µg L-1, respectively. The sensitivity of the developed method was allowed for determination of target compounds at trace level in environmental water samples. The in-house validation of the developed method was performed by spiking experiment in both the surface water and hospital wastewater matrix. The method was then applied to analyze several surface water and hospital wastewater samples taken from West Lake and some hospitals in Vietnam, where the level of these pharmaceutical product residues was still missed. Sulfamethoxazole was present at a high detection frequency in both surface water (33% of analyzed samples) and hospital wastewater (81% of analyzed samples) samples.

4.
J Anal Methods Chem ; 2019: 3489634, 2019.
Article in English | MEDLINE | ID: mdl-31205797

ABSTRACT

An ultrahigh-performance liquid chromatography in combination with high-resolution mass spectrometry Thermo Q-Extractive Focus Orbitrap MS has been introduced for analysis of multiclass pesticides in vegetable samples collected in Hanoi, Vietnam. Multiclass pesticides were separated on the Thermo Hypersil Gold PFP column utilizing a gradient of the mobile phase consisting of 5 mM ammonium formate, 0.1% formic acid in deionized water, and methanol. The target analytes were detected in the full-scan mode on Thermo Scientific Q-Exactive Focus Orbitrap MS for quantitation at the optimum operating conditions. These conditions included, but not limit to, the resolution of 70000 at the full width at half maximum in both positive and negative mode, mass range from 80 to 1000 m/z, and optimized parameters for the heated electrospray ionization source. The identification of the analytes in real samples was based on retention times, mass to charge ratios, mass accuracies, and MS/MS spectra at the confirmation mode with the inclusion list of target analytes. The mass accuracies of target analytes were from -4.14 ppm (dinotefuran) to 1.42 ppm (cinosulfuron) in the neat solvent and from -3.91 ppm (spinosad D) to 1.29 ppm (cinosulfuron) in the matrix-matched solution. Target analytes in the vegetable-based matrix were extracted by the QuEChERS method. Some critical parameters of the analytical method such as linearity, repeatability, limit of detection, and limit of quantitation have been evaluated and implemented. Excellent LOD and LOQ of the developed method were achieved at the range of 0.04-0.85 and 0.13-2.9 µg·kg-1, respectively. Intraday and interday repeatability of the analytical signal (peak area, n=6) of the developed method were below 3% and 10%, correspondingly. The matrix effect, extraction recovery, and overall recovery were fully investigated by spiking experiments. Experimental results demonstrated that the ionization suppression or enhancement was the main contribution on the overall recoveries of target analytes. Finally, the in-house validated method was applied to pesticides screening in vegetables samples in local villages in Hanoi, Vietnam. The concentrations of all target analytes were below limit of quantitation and lower than US-FDA or EU maximum residue levels.

SELECTION OF CITATIONS
SEARCH DETAIL
...