Rev. bras. cineantropom. desempenho hum ; 25: e92458, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1529715

ABSTRACT

Abstract The aim of this study was to investigate the agreement and reproducibility of a portable electrical impedance myography device (EIM - SKULPT®) for body fat percentage (BF%) estimation in young adults. Sixty young adults volunteered for the study (women, n=30, 25.0±7.7 years; 21.5±1.9 kg/m2; and men, n=30, 21.6±6.3 years; 22.5±1.8 kg/m2). Participants underwent air displacement plethysmography (ADP) and EIM measurements for agreement analysis. EIM was performed three times on the same day for the within-day reproducibility analysis. Seven days later, 37 participants repeated the EIM measurements for the between-days reproducibility analysis. Comparisons of EIM and ADP methods, and EIM repeated measurements were performed with the paired T-test or one-way ANOVA repeated measures, the Bland-Altman plot, and simple linear regressions. BF% was higher (p<0.05) when estimated by EIM (19.91 ± 5.70 for men, and 30.77 ± 5.89 for women) compared to ADP (15.28 ± 5.66 for men, and 27.31 ± 5.98 for women). The Bland-Altman analysis presented a bias of 4.4% (95%CI=-3.4-12.2) and linear regression presented an R2=0.78. For between-days reproducibility, EIM means did not differ (25.33±7.69 and 24.94±8.30, p=0.890). Thus, while the EIM device exhibited high reproducibility of BF% estimates, caution should be exercised when comparing the results with other techniques for measuring BF%. The EIM device overestimated BF% compared to ADP. However, the EIM measurements presented very good within-day and between-days reproducibility and, thus, the EIM device can be used for longitudinal monitoring of BF%.


Resumo O objetivo deste estudo foi investigar a concordância e a reprodutibilidade de um aparelho portátil de miografia por impedância elétrica (EIM - SKULPT®) para estimativa do percentual de gordura corporal (GC%) em adultos jovens. Sessenta adultos jovens foram voluntários para o estudo (mulheres, n=30, 25,0±7,7 anos; 21,5±1,9 kg/m2; e homens, n=30, 21,6±6,3 anos; 22,5±1,8 kg/m2). Os participantes fizeram medições de pletismografia de deslocamento de ar (ADP) e EIM para análise de concordância. A EIM foi realizada três vezes no mesmo dia para a análise de reprodutibilidade dentro do dia. Sete dias depois, 37 participantes repetiram as medições do EIM para a análise de reprodutibilidade entre dias. As comparações dos métodos EIM e ADP e medições repetidas do EIM foram realizadas com o teste T pareado ou medidas repetidas ANOVA de uma via, o gráfico de Bland-Altman e regressões lineares simples. O %GC foi maior (p<0,05) quando estimado pelo EIM (19,91 ± 5,70 para homens e 30,77 ± 5,89 para mulheres) em relação ao ADP (15,28 ± 5,66 para homens e 27,31 ± 5,98 para mulheres). A análise de Bland-Altman apresentou viés de 4,4% (IC95%=-3,4-12,2) e a regressão linear apresentou R2=0,78. Para a reprodutibilidade entre dias, as médias do EIM não diferiram (25,33±7,69 e 24,94±8,30, p=0,890). Assim, enquanto o dispositivo EIM exibiu alta reprodutibilidade das estimativas de %GC, deve-se ter cautela ao comparar os resultados com outras técnicas para medir %GC. O dispositivo EIM superestimou %GC em comparação com ADP. No entanto, as medidas de EIM apresentaram reprodutibilidade intradia e entre dias muito boa e, portanto, o dispositivo de EIM pode ser usado para monitoramento longitudinal de %GC.

2.
J Exerc Rehabil ; 14(4): 654-659, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30276189

ABSTRACT

Functional resistance training can increase strength, knee torque ratio, and functional performance in elderly women. The aim of the present study was to understand the effects of closed kinetic chain exercises with constant load on muscular strength, the knee torque conventional ratio (hamstring:quadriceps - H:Q), and functional capacity in the elderly. Nine untrained healthy elderly women participated in experimental resistance training. Ten-repetition maximum (10RM) for the deadlift, isokinetic maximum voluntary concentric contraction, and functional capacity were assessed before and after the 7-week resistance-training program. Magnitude based inference analysis was used to examine the differences in muscle strength and functional performance. Therefore, the smallest worthwhile change was calculated and 90% confidence intervals were also determined to characterize muscle strength and functional performance. The analysis demonstrated an increase in the deadlift and knee flexor torque (60o/sec) after the experimental intervention. Furthermore, stair ascent, knee extensor torque (120o/sec), knee flexor torque (120o/sec), and knee ratio (60o/sec) also presented a positive effect in the same training period. Conversely, knee extensor torque (60o/sec), and knee ratio (120o/sec) did not show conclusive responses. In conclusion, resistance training with functional closed kinetic chain exercises and constant volume load (i.e., 65% of 1-repetition maximum) can increase deadlift 10RM, isokinetic concentric torque, the conventional H:Q ratio, and stair ascent performance in elderly women.

3.
Arch. Health Sci. (Online) ; 24(4): 69-72, 22/12/2017.
Article in Portuguese | LILACS | ID: biblio-1046932

ABSTRACT

Introdução: Reconhece-se que o diabetes é uma doença que, independentemente da faixa etária e da etiologia, causa impac-to negativo que compromete a qualidade de vida. A avaliação da qualidade de vida de indivíduos com doenças crônicas tem sido objeto de investigação na área da saúde, sendo considerada importante indicador dos resultados terapêuticos em diferentes situações clínicas. Objetivo: Realizar uma revisão integrativa apresentando os instrumentos utilizados para a avaliação da qualidade de vida em indivíduos com diabetes mellitus. Ma-teriais e Métodos: Foi realizada revisão integrativa nas bases de dados MEDLINE, LILACS, SCIELO, relativo aos anos de 2009 a 2017, utilizando os descritores: Diabetes Mellitus, Qua-lidade de Vida e Avaliação. Resultados: Foram selecionados sete artigos que em suas metodologias apresentaram quatro instrumentos de avaliação da qualidade de vida. Conclusão: As evidências demonstram que não existe uma padronização dos instrumentos em relação a avaliação da qualidade de vida em indivíduos com diabetes mellitus


Introduction: It is recognized that diabetes is a disease that, despite of the age and etiology, causes a negative impact that impairs the quality of life. The evaluation of chronic patients' quality of life has been the object of health researches, being considered an important indicator of the therapeutic results in different clinical situations. Objective: Perform an integrative review of the literature, presenting the instruments used for the evaluation of the quality of life in patients with Diabetes Mel-litus. Materials andMethods: It was performed an integrative review on the MEDLINE, LILACS and SCIELO databases from 2009 to 2017, using the descriptors: "Diabetes Mellitus", "Quality of Life", and "Evaluation". Results: Seven articles were selected, which methodologies presented four quality of life assessment instruments. Conclusion: The evidences show that there is no standardization regarding to the evaluation of the quality of life in patients with Diabetes Mellitus.


Subject(s)
Quality of Life , Review Literature as Topic , Diabetes Mellitus
SELECTION OF CITATIONS
SEARCH DETAIL
...