1.
Biosensors (Basel) ; 13(9)2023 Sep 08.
Article in English | MEDLINE | ID: mdl-37754110

ABSTRACT

This study presents the development of a portable fluorometer with a smartphone application designed to facilitate the early screening of chronic kidney and renal diseases by enabling the sensitive detection of urinary albumin. Utilizing a fluorescence-based aptasensor, the device achieved a linear calibration curve (0.001-1.5 mg/mL) with a linearity of up to 0.98022 and a detection limit of 0.203 µg/mL for human serum albumin (HSA). The analysis of 130 urine samples demonstrated comparable performance between this study's fluorometer, a commercial fluorometer, and the standard automated method. These findings validate the feasibility of the portable fluorometer and aptasensor combination as a reliable instrument for the sensitive and specific measurement of HSA in urine samples. Moreover, the fluorometer's portability offers potential applications in portable point-of-care testing, enhancing its utility in clinical settings for early disease screening.


Subject(s)
Mobile Applications , Smartphone , Humans , Serum Albumin, Human , Calibration , Chronic Disease , Kidney
2.
Biosensors (Basel) ; 12(11)2022 Oct 24.
Article in English | MEDLINE | ID: mdl-36354425

ABSTRACT

The instability of human serum albumin (HSA) in urine samples makes fresh urine a requirement for microalbumin analyses using immunoturbidimetry. Here, we determined the ability of an aptasensor-based fluorescent platform to detect microalbumin in old, boric acid-preserved urine samples. Our results show that the cleavage site of protease enzymes on urine albumin protein differed from the binding position of the aptamer on HSA protein, suggesting the aptasensor may be effective for albumin detection in non-fresh urine. Furthermore, the addition of boric acid in urine samples over a short term (at ambient temperature (Ta) and 4 °C), long term (-20 and -80 °C), and following freeze-thawing (1-3 cycles) did not significantly affect albumin stability, as analyzed using the aptasensor. Therefore, boric acid stabilized has in urine stored over a short- and long-term. Thus, the aptasensor developed by us is applicable for HSA detection in boric acid-preserved urine that has been stored for 7-d at Ta and 4 °C, and in the long-term at -80 °C.


Subject(s)
Boric Acids , Urinalysis , Humans , Temperature , Proteins